Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics最新文献

筛选
英文 中文
High sensitivity saliva-based biosensor in detection of breast cancer biomarkers: HER2 and CA15-3. 基于唾液的高灵敏度生物传感器用于检测乳腺癌生物标记物:HER2 和 CA15-3。
4区 工程技术
Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics Pub Date : 2024-03-01 Epub Date: 2024-02-13 DOI: 10.1116/6.0003370
Hsiao-Hsuan Wan, Haochen Zhu, Chao-Ching Chiang, Jian-Sian Li, Fan Ren, Cheng-Tse Tsai, Yu-Te Liao, Dan Neal, Josephine F Esquivel-Upshaw, Stephen J Pearton
{"title":"High sensitivity saliva-based biosensor in detection of breast cancer biomarkers: HER2 and CA15-3.","authors":"Hsiao-Hsuan Wan, Haochen Zhu, Chao-Ching Chiang, Jian-Sian Li, Fan Ren, Cheng-Tse Tsai, Yu-Te Liao, Dan Neal, Josephine F Esquivel-Upshaw, Stephen J Pearton","doi":"10.1116/6.0003370","DOIUrl":"10.1116/6.0003370","url":null,"abstract":"<p><p>The prevalence of breast cancer in women underscores the urgent need for innovative and efficient detection methods. This study addresses this imperative by harnessing salivary biomarkers, offering a noninvasive and accessible means of identifying breast cancer. In this study, commercially available disposable based strips similar to the commonly used glucose detection strips were utilized and functionalized to detect breast cancer with biomarkers of HER2 and CA15-3. The results demonstrated limits of detection for these two biomarkers reached as low as 1 fg/ml much lower than those of conventional enzyme-linked immunosorbent assay in the range of 1∼4 ng/ml. By employing a synchronized double-pulse method to apply 10 of 1.2 ms voltage pulses to the electrode of sensing strip and drain electrode of the transistor for amplifying the detected signal, and the detected signal was the average of 10 digital output readings corresponding to those 10 voltage pulses. The sensor sensitivities were achieved approximately 70/dec and 30/dec for HER2 and CA15-3, respectively. Moreover, the efficiency of this novel technique is underscored by its swift testing time of less than 15 ms and its minimal sample requirement of only 3 <i>μ</i>l of saliva. The simplicity of operation and the potential for widespread public use in the future position this approach as a transformative tool in the early detection of breast cancer. This research not only provides a crucial advancement in diagnostic methodologies but also holds the promise of revolutionizing public health practices.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10866624/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139742245","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optical and electronic spin properties of fluorescent micro- and nanodiamonds upon prolonged ultrahigh-temperature annealing. 荧光微金刚石和纳米金刚石在长时间超高温退火下的光学和电子自旋特性。
IF 1.5 4区 工程技术
Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics Pub Date : 2023-07-01 Epub Date: 2023-06-27 DOI: 10.1116/6.0002797
Nicholas Nunn, Sergey Milikisiyants, Marco D Torelli, Richard Monge, Tom Delord, Alexander I Shames, Carlos A Meriles, Ashok Ajoy, Alex I Smirnov, Olga A Shenderova
{"title":"Optical and electronic spin properties of fluorescent micro- and nanodiamonds upon prolonged ultrahigh-temperature annealing.","authors":"Nicholas Nunn, Sergey Milikisiyants, Marco D Torelli, Richard Monge, Tom Delord, Alexander I Shames, Carlos A Meriles, Ashok Ajoy, Alex I Smirnov, Olga A Shenderova","doi":"10.1116/6.0002797","DOIUrl":"10.1116/6.0002797","url":null,"abstract":"<p><p>High-temperature annealing is a promising but still mainly unexplored method for enhancing spin properties of negatively charged nitrogen-vacancy (NV) centers in diamond particles. After high-energy irradiation, the formation of NV centers in diamond particles is typically accomplished via annealing at temperatures in the range of 800-900 °C for 1-2 h to promote vacancy diffusion. Here, we investigate the effects of conventional annealing (900 °C for 2 h) against annealing at a much higher temperature of 1600 °C for the same annealing duration for particles ranging in size from 100 nm to 15 <i>μ</i>m using electron paramagnetic resonance and optical characterization. At this high temperature, the vacancy-assisted diffusion of nitrogen can occur. Previously, the annealing of diamond particles at this temperature was performed over short time scales because of concerns of particle graphitization. Our results demonstrate that particles that survive this prolonged 1600 °C annealing show increased NV <i>T</i><sub>1</sub> and <i>T</i><sub>2</sub> electron spin relaxation times in 1 and 15 <i>μ</i>m particles, due to the removal of fast relaxing spins. Additionally, this high-temperature annealing also boosts magnetically induced fluorescence contrast of NV centers for particle sizes ranging from 100 nm to 15 <i>μ</i>m. At the same time, the content of NV centers is decreased fewfold and reaches a level of <0.5 ppm. The results provide guidance for future studies and the optimization of high-temperature annealing of fluorescent diamond particles for applications relying on the spin properties of NV centers in the host crystals.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10306410/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10097479","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
High sensitivity CIP2A detection for oral cancer using a rapid transistor-based biosensor module. 基于快速晶体管的生物传感器模块的口腔癌高灵敏度CIP2A检测。
4区 工程技术
Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics Pub Date : 2023-01-01 Epub Date: 2022-12-13 DOI: 10.1116/6.0002175
Minghan Xian, Jenna L Stephany, Chan-Wen Chiu, Chao-Ching Chiang, Fan Ren, Cheng-Tse Tsai, Siang-Sin Shan, Yu-Te Liao, Josephine F Esquivel-Upshaw, Stephen J Pearton
{"title":"High sensitivity CIP2A detection for oral cancer using a rapid transistor-based biosensor module.","authors":"Minghan Xian, Jenna L Stephany, Chan-Wen Chiu, Chao-Ching Chiang, Fan Ren, Cheng-Tse Tsai, Siang-Sin Shan, Yu-Te Liao, Josephine F Esquivel-Upshaw, Stephen J Pearton","doi":"10.1116/6.0002175","DOIUrl":"10.1116/6.0002175","url":null,"abstract":"<p><p>Oral squamous cell carcinoma (OSCC) is one of the most common lip and oral cavity cancer types. It requires early detection via various medical technologies to improve the survival rate. While most detection techniques for OSCC require testing in a centralized lab to confirm cancer type, a point of care detection technique is preferred for on-site use and quick result readout. The modular biological sensor utilizing transistor-based technology has been leveraged for testing CIP2A, and optimal transistor gate voltage and load resistance for sensing setup was investigated. Sensitivities of 1 × 10<sup>-15</sup> g/ml have been obtained for both detections of pure CIP2A protein and HeLa cell lysate using identical test conditions via serial dilution. The superior time-saving and high accuracy testing provides opportunities for rapid clinical diagnosis in the medical space.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9750712/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10400714","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Rapid SARS-CoV-2 diagnosis using disposable strips and a metal-oxide-semiconductor field-effect transistor platform. 使用一次性试纸和金属氧化物半导体场效应晶体管平台快速诊断SARS-CoV-2。
4区 工程技术
Chan-Wen Chiu, Minghan Xian, Jenna L Stephany, Xinyi Xia, Chao-Ching Chiang, Fan Ren, Cheng-Tse Tsai, Siang-Sin Shan, Yu-Te Liao, Josephine F Esquivel-Upshaw, Santosh R Rananaware, Long T Nguyen, Nicolas C Macaluso, Piyush K Jain, Melanie N Cash, Carla N Mavian, Marco Salemi, Marino E Leon, Chin-Wei Chang, Jenshan Lin, Stephen J Pearton
{"title":"Rapid SARS-CoV-2 diagnosis using disposable strips and a metal-oxide-semiconductor field-effect transistor platform.","authors":"Chan-Wen Chiu,&nbsp;Minghan Xian,&nbsp;Jenna L Stephany,&nbsp;Xinyi Xia,&nbsp;Chao-Ching Chiang,&nbsp;Fan Ren,&nbsp;Cheng-Tse Tsai,&nbsp;Siang-Sin Shan,&nbsp;Yu-Te Liao,&nbsp;Josephine F Esquivel-Upshaw,&nbsp;Santosh R Rananaware,&nbsp;Long T Nguyen,&nbsp;Nicolas C Macaluso,&nbsp;Piyush K Jain,&nbsp;Melanie N Cash,&nbsp;Carla N Mavian,&nbsp;Marco Salemi,&nbsp;Marino E Leon,&nbsp;Chin-Wei Chang,&nbsp;Jenshan Lin,&nbsp;Stephen J Pearton","doi":"10.1116/6.0001615","DOIUrl":"https://doi.org/10.1116/6.0001615","url":null,"abstract":"<p><p>The SARS-CoV-2 pandemic has had a significant impact worldwide. Currently, the most common detection methods for the virus are polymerase chain reaction (PCR) and lateral flow tests. PCR takes more than an hour to obtain the results and lateral flow tests have difficulty with detecting the virus at low concentrations. In this study, 60 clinical human saliva samples, which included 30 positive and 30 negative samples confirmed with RT-PCR, were screened for COVID-19 using disposable glucose biosensor strips and a reusable printed circuit board. The disposable strips were gold plated and functionalized to immobilize antibodies on the gold film. After functionalization, the strips were connected to the gate electrode of a metal-oxide-semiconductor field-effect transistor on the printed circuit board to amplify the test signals. A synchronous double-pulsed bias voltage was applied to the drain of the transistor and strips. The resulting change in drain waveforms was converted to digital readings. The RT-PCR-confirmed saliva samples were tested again using quantitative PCR (RT-qPCR) to determine cycling threshold (Ct) values. Ct values up to 45 refer to the number of amplification cycles needed to detect the presence of the virus. These PCR results were compared with digital readings from the sensor to better evaluate the sensor technology. The results indicate that the samples with a range of Ct values from 17.8 to 35 can be differentiated, which highlights the increased sensitivity of this sensor technology. This research exhibits the potential of this biosensor technology to be further developed into a cost-effective, point-of-care, and portable rapid detection method for SARS-CoV-2.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8830941/pdf/JVTBD9-000040-023204_1.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10869239","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Digital biosensor for human cerebrospinal fluid detection with single-use sensing strips. 利用一次性使用的传感条检测人体脑脊液的数字生物传感器。
IF 1.5 4区 工程技术
Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics Pub Date : 2022-03-01 Epub Date: 2022-02-01 DOI: 10.1116/6.0001576
Minghan Xian, Chan-Wen Chiu, Patrick H Carey, Chaker Fares, Liya Chen, Rena Wu, Fan Ren, Cheng-Tse Tsai, Siang-Sin Shan, Yu-Te Liao, Josephine F Esquivel-Upshaw, Stephen J Pearton
{"title":"Digital biosensor for human cerebrospinal fluid detection with single-use sensing strips.","authors":"Minghan Xian, Chan-Wen Chiu, Patrick H Carey, Chaker Fares, Liya Chen, Rena Wu, Fan Ren, Cheng-Tse Tsai, Siang-Sin Shan, Yu-Te Liao, Josephine F Esquivel-Upshaw, Stephen J Pearton","doi":"10.1116/6.0001576","DOIUrl":"10.1116/6.0001576","url":null,"abstract":"<p><p>Leakage of human cerebrospinal fluid (CSF) caused by trauma or other reasons presents exceptional challenges in clinical analysis and can have severe medical repercussions. Conventional test methods, including enzyme-linked immunosorbent assay and immunofixation electrophoresis testing, typically are performed at a few clinical reference laboratories, which may potentially delay proper diagnosis and treatment. At the same time, medical imaging can serve as a secondary diagnosis tool. This work presented here reports the use of a point-of-care electrochemical sensor for detection of beta-2-transferrin (B2T), a unique isomer of transferrin that is present exclusively in human CSF but is absent in other bodily fluids. Limits of detection were examined via serial dilution of human samples with known B2T concentrations down to 7 × 10<sup>-12</sup> g B2T/ml while maintaining excellent sensitivity. Nine human samples with varying levels of B2T were compared using up to 100 times dilution to confirm the validity of sensor output across different patient samples.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8810203/pdf/JVTBD9-000040-023202_1.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10869237","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Planar figure-8 coils for ultra-focal and directional micromagnetic brain stimulation. 用于超聚焦和定向微磁脑部刺激的平面数字 8 线圈。
IF 1.5 4区 工程技术
Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics Pub Date : 2021-12-01 Epub Date: 2021-10-13 DOI: 10.1116/6.0001281
Hongbae Jeong, Jiangdong Deng, Giorgio Bonmassar
{"title":"Planar figure-8 coils for ultra-focal and directional micromagnetic brain stimulation.","authors":"Hongbae Jeong, Jiangdong Deng, Giorgio Bonmassar","doi":"10.1116/6.0001281","DOIUrl":"10.1116/6.0001281","url":null,"abstract":"<p><p>Recently, white-matter fiber tract pathways carrying neural signals through the brain were shown to follow curved, orthogonal grids. This study focuses on how these white-matter fibers may be selectively excited using micromagnetic stimulation (<i>μ</i>MS), a new type of neuronal stimulation, which generates microscopic eddy currents capable of directionally activating neurons. One of the most remarkable properties of this novel type of stimulation is that the <i>μ</i>MS fields provide unique directional activation of neuronal elements not seen with traditional electrical stimulation. An initial prototype built with SU-8 based photolithography technology shows that the structure can be fabricated. The coil design was optimized through electrical resistance calculations and electric field simulations to elicit the brain's maximal focal and directional neural responses.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8516478/pdf/JVTBD9-000039-063202_1.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39553012","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fast SARS-CoV-2 virus detection using disposable cartridge strips and a semiconductor-based biosensor platform. 使用一次性滤芯条和基于半导体的生物传感器平台快速检测 SARS-CoV-2 病毒。
IF 1.5 4区 工程技术
Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics Pub Date : 2021-05-01 Epub Date: 2021-05-18 DOI: 10.1116/6.0001060
Minghan Xian, Hao Luo, Xinyi Xia, Chaker Fares, Patrick H Carey, Chan-Wen Chiu, Fan Ren, Siang-Sin Shan, Yu-Te Liao, Shu-Min Hsu, Josephine F Esquivel-Upshaw, Chin-Wei Chang, Jenshan Lin, Steven C Ghivizzani, Stephen J Pearton
{"title":"Fast SARS-CoV-2 virus detection using disposable cartridge strips and a semiconductor-based biosensor platform.","authors":"Minghan Xian, Hao Luo, Xinyi Xia, Chaker Fares, Patrick H Carey, Chan-Wen Chiu, Fan Ren, Siang-Sin Shan, Yu-Te Liao, Shu-Min Hsu, Josephine F Esquivel-Upshaw, Chin-Wei Chang, Jenshan Lin, Steven C Ghivizzani, Stephen J Pearton","doi":"10.1116/6.0001060","DOIUrl":"10.1116/6.0001060","url":null,"abstract":"<p><p>Detection of the SARS-CoV-2 spike protein and inactivated virus was achieved using disposable and biofunctionalized functional strips, which can be connected externally to a reusable printed circuit board for signal amplification with an embedded metal-oxide-semiconductor field-effect transistor (MOSFET). A series of chemical reactions was performed to immobilize both a monoclonal antibody and a polyclonal antibody onto the Au-plated electrode used as the sensing surface. An important step in the biofunctionalization, namely, the formation of Au-plated clusters on the sensor strips, was verified by scanning electron microscopy, as well as electrical measurements, to confirm successful binding of thiol groups on this Au surface. The functionalized sensor was externally connected to the gate electrode of the MOSFET, and synchronous pulses were applied to both the sensing strip and the drain contact of the MOSFET. The resulting changes in the dynamics of drain waveforms were converted into analog voltages and digital readouts, which correlate with the concentration of proteins and virus present in the tested solution. A broad range of protein concentrations from 1 fg/ml to 10 <i>μ</i>g/ml and virus concentrations from 100 to 2500 PFU/ml were detectable for the sensor functionalized with both antibodies. The results show the potential of this approach for the development of a portable, low-cost, and disposable cartridge sensor system for point-of-care detection of viral diseases.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2021-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8133793/pdf/JVTBD9-000039-033202_1.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38965351","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Developing Single Layer MOS Quantum Dots for Diagnostic Qubits. 用于诊断量子比特的单层MOS量子点的开发。
4区 工程技术
Yanxue Hong, A N Ramanayaka, Ryan Stein, M D Stewart, J M Pomeroy
{"title":"Developing Single Layer MOS Quantum Dots for Diagnostic Qubits.","authors":"Yanxue Hong,&nbsp;A N Ramanayaka,&nbsp;Ryan Stein,&nbsp;M D Stewart,&nbsp;J M Pomeroy","doi":"10.1116/6.0000549","DOIUrl":"https://doi.org/10.1116/6.0000549","url":null,"abstract":"<p><p>The design, fabrication and characterization of single metal gate layer, metal-oxide-semiconductor (MOS) quantum dot devices robust against dielectric breakdown are presented as prototypes for future diagnostic qubits. These devices were developed as a preliminary solution to a longer term goal of a qubit platform for intercomparison between materials or for in-line diagnostics, and to provide a testbed for establishing classical measurements predictive of coherence performance. For this stage, we seek a robust MOS design that is compatible with wafer and chip architectures, that has a reduced process overhead and is sufficiently capable of challenging and advancing our measurement capabilities. In this report, we present our initial batch of silicon MOS devices using a single gate layer, which have not exhibited any failures with gate voltage excursions > 10 V, but do exhibit the reduced electrostatic control expected of a single gate layer design. We observe quantum dot formation, capacitive charge sensing between channels, and reasonable effective electron temperatures that enable spin qubit studies. The costs and benefits of the trade-off between device performance and fabrication efficiency will be discussed, as well as opportunities for future improvements.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8269032/pdf/nihms-1700903.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39174579","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Polyphosphazene polymers: The next generation of biomaterials for regenerative engineering and therapeutic drug delivery. 聚磷腈聚合物:用于再生工程和治疗药物输送的下一代生物材料。
IF 1.5 4区 工程技术
Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics Pub Date : 2020-05-01 Epub Date: 2020-04-09 DOI: 10.1116/6.0000055
Kenneth S Ogueri, Kennedy S Ogueri, Harry R Allcock, Cato T Laurencin
{"title":"Polyphosphazene polymers: The next generation of biomaterials for regenerative engineering and therapeutic drug delivery.","authors":"Kenneth S Ogueri, Kennedy S Ogueri, Harry R Allcock, Cato T Laurencin","doi":"10.1116/6.0000055","DOIUrl":"10.1116/6.0000055","url":null,"abstract":"<p><p>The demand for new biomaterials in several biomedical applications, such as regenerative engineering and drug delivery, has increased over the past two decades due to emerging technological advances in biomedicine. Degradable polymeric biomaterials continue to play a significant role as scaffolding materials and drug devices. Polyphosphazene platform is a subject of broad interest, as it presents an avenue for attaining versatile polymeric materials with excellent structure and property tunability, and high functional diversity. Macromolecular substitution enables the facile attachment of different organic groups and drug molecules to the polyphosphazene backbone for the development of a broad class of materials. These materials are more biocompatible than traditional biomaterials, mixable with other clinically relevant polymers to obtain new materials and exhibit unique erosion with near-neutral degradation products. Hence, polyphosphazene represents the next generation of biomaterials. In this review, the authors systematically discuss the synthetic design, structure-property relationships, and the promising potentials of polyphosphazenes in regenerative engineering and drug delivery.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7156271/pdf/JVTBD9-000038-030801_1.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"37850376","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Detecting nanoscale contamination in semiconductor fabrication using through-focus scanning optical microscopy. 利用透焦扫描光学显微镜检测半导体制造中的纳米级污染。
4区 工程技术
Min-Ho Rim, Emil Agocs, Ronald Dixson, Prem Kavuri, András E Vladár, Ravi Kiran Attota
{"title":"Detecting nanoscale contamination in semiconductor fabrication using through-focus scanning optical microscopy.","authors":"Min-Ho Rim,&nbsp;Emil Agocs,&nbsp;Ronald Dixson,&nbsp;Prem Kavuri,&nbsp;András E Vladár,&nbsp;Ravi Kiran Attota","doi":"10.1116/6.0000352","DOIUrl":"https://doi.org/10.1116/6.0000352","url":null,"abstract":"<p><p>This paper reports high-throughput, light-based, through-focus scanning optical microscopy (TSOM) for detecting industrially relevant sub-50 nm tall nanoscale contaminants. Measurement parameter optimization to maximize the TSOM signal using optical simulations made it possible to detect the nanoscale contaminants. Atomic force and scanning electron microscopies were used as reference methods for comparison.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1116/6.0000352","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39235483","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信