{"title":"在原子力显微镜测量中最小化开环压电致动器非线性伪影。","authors":"Chi-Fu Yen, Sanjeevi Sivasankar","doi":"10.1116/1.4994315","DOIUrl":null,"url":null,"abstract":"<p><p>Atomic force microscopes (AFMs) are widely used to study molecular interactions with piconewton force sensitivity. In an AFM, interaction forces are measured by reflecting a laser beam off a cantilever onto a position sensitive detector and monitoring cantilever deflection. Precise measurements of interaction forces rely on accurately determining the optical lever sensitivity, i.e., the relationship between cantilever deflection and changes in detector voltage. The optical lever sensitivity is measured by pressing the cantilever against a hard substrate using a piezoactuator and recording the resulting change in detector voltage. However, nonlinearities in the motion of commonly used open-loop piezo actuators introduce significant errors in measured optical lever sensitivities. Here, the authors systematically characterize the effect of piezo actuator hysteresis and creep on errors in optical lever sensitivity and identify measurement conditions that minimize these errors.</p>","PeriodicalId":38110,"journal":{"name":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1116/1.4994315","citationCount":"1","resultStr":"{\"title\":\"Minimizing open-loop piezoactuator nonlinearity artifacts in atomic force microscope measurements.\",\"authors\":\"Chi-Fu Yen, Sanjeevi Sivasankar\",\"doi\":\"10.1116/1.4994315\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Atomic force microscopes (AFMs) are widely used to study molecular interactions with piconewton force sensitivity. In an AFM, interaction forces are measured by reflecting a laser beam off a cantilever onto a position sensitive detector and monitoring cantilever deflection. Precise measurements of interaction forces rely on accurately determining the optical lever sensitivity, i.e., the relationship between cantilever deflection and changes in detector voltage. The optical lever sensitivity is measured by pressing the cantilever against a hard substrate using a piezoactuator and recording the resulting change in detector voltage. However, nonlinearities in the motion of commonly used open-loop piezo actuators introduce significant errors in measured optical lever sensitivities. Here, the authors systematically characterize the effect of piezo actuator hysteresis and creep on errors in optical lever sensitivity and identify measurement conditions that minimize these errors.</p>\",\"PeriodicalId\":38110,\"journal\":{\"name\":\"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1116/1.4994315\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1116/1.4994315\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/9/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vacuum Science and Technology B:Nanotechnology and Microelectronics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1116/1.4994315","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/9/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Minimizing open-loop piezoactuator nonlinearity artifacts in atomic force microscope measurements.
Atomic force microscopes (AFMs) are widely used to study molecular interactions with piconewton force sensitivity. In an AFM, interaction forces are measured by reflecting a laser beam off a cantilever onto a position sensitive detector and monitoring cantilever deflection. Precise measurements of interaction forces rely on accurately determining the optical lever sensitivity, i.e., the relationship between cantilever deflection and changes in detector voltage. The optical lever sensitivity is measured by pressing the cantilever against a hard substrate using a piezoactuator and recording the resulting change in detector voltage. However, nonlinearities in the motion of commonly used open-loop piezo actuators introduce significant errors in measured optical lever sensitivities. Here, the authors systematically characterize the effect of piezo actuator hysteresis and creep on errors in optical lever sensitivity and identify measurement conditions that minimize these errors.