Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine最新文献

筛选
英文 中文
Evaluation of Early Renal Changes in Type 2 Diabetes Mellitus Using Multiparametric MR Imaging. 利用多参数磁共振成像评估 2 型糖尿病早期肾脏变化
Xinyi Chen, Chao Ge, Yuling Zhang, Yajie Ma, Yuling Zhang, Bei Li, Zhiqiang Chu, Qian Ji
{"title":"Evaluation of Early Renal Changes in Type 2 Diabetes Mellitus Using Multiparametric MR Imaging.","authors":"Xinyi Chen, Chao Ge, Yuling Zhang, Yajie Ma, Yuling Zhang, Bei Li, Zhiqiang Chu, Qian Ji","doi":"10.2463/mrms.mp.2023-0148","DOIUrl":"https://doi.org/10.2463/mrms.mp.2023-0148","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the clinical value of early renal changes in type 2 diabetes mellitus (T2DM) using multiparameter MRI.</p><p><strong>Methods: </strong>The study included 41 diabetics (normoalbuminuria: n = 23; microalbuminuria: n = 18) and 30 healthy controls. All subjects underwent intravoxel incoherent motion diffusion-weighted imaging (IVIM), blood oxygen level dependent (BOLD) and arterial spin labeling (ASL) examinations. One-way analysis of variance was used to compare MRI parameters among the three groups. Pearson correlation analysis was used to evaluate the relationship between MRI parameters and estimated glomerular filtration rate (eGFR) and albumin-creatinine ratio (ACR). Receiver operating characteristic analysis was performed to assess the diagnostic performance.</p><p><strong>Results: </strong>There were statistical differences in cortical D, D*, f, renal blood flow (RBF) and medulla D, D*, f, R2* among the three groups (P < 0.05). The cortical or medullary D, cortical f, and RBF were significantly positively correlated with eGFR (all P < 0.01). The cortical or medullary D, D*, f, cortical RBF were negatively correlated with ACR (all P < 0.05).To evaluate early kidney changes and degree of diabetes, cortical combined D and RBF (AUC [area under the curve]  = 0.796 and 0.947, respectively) was better than single D or RBF (all P > 0.05); medullary combined D and R2* (AUC = 0.899 and 0.923, respectively) was better than single D or R2* (all P > 0.05), except single D (P = 0.005) in differentiating normoalbuminuria group from control group.</p><p><strong>Conclusion: </strong>The early changes of renal diffusion and perfusion, oxygenation level, and blood flow in T2DM could be evaluated noninvasively and quantitatively using IVIM, BOLD and ASL. Renal medullary combined IVIM-derived D and BOLD-derived R2* and cortical combined IVIM-derived D and ASL-derived RBF were better for evaluating early renal changes in T2DM.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142383049","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Characterizing Protein Concentration in Cerebrospinal Fluid with T2 Component Analysis. 用 T2 成分分析法表征脑脊液中的蛋白质浓度
Tatsuya Koizumi, Seiko Shimizu, Chihiro Akiba, Hidenori Kakizoe, Hideki Bandai, Kenichi Sato, Hidekazu Nagasawa, Ikuko Ogino, Madoka Nakajima, Shinya Yamada, Koichi Oshio, Masakazu Miyajima
{"title":"Characterizing Protein Concentration in Cerebrospinal Fluid with T<sub>2</sub> Component Analysis.","authors":"Tatsuya Koizumi, Seiko Shimizu, Chihiro Akiba, Hidenori Kakizoe, Hideki Bandai, Kenichi Sato, Hidekazu Nagasawa, Ikuko Ogino, Madoka Nakajima, Shinya Yamada, Koichi Oshio, Masakazu Miyajima","doi":"10.2463/mrms.mp.2023-0157","DOIUrl":"https://doi.org/10.2463/mrms.mp.2023-0157","url":null,"abstract":"<p><strong>Purpose: </strong>T<sub>2</sub> values are hypothesized to be reduced where protein accumulates in the cerebrospinal fluid (CSF). We aimed to verify the accuracy of Carr-Purcell-Meiboom-Gil (CPMG) pulses and non-negative least squares (NNLS) analysis in visualizing protein concentrations by mapping the T<sub>2</sub> values.</p><p><strong>Methods: </strong>We first dissolved 1.2g of bovine serum albumin powder in 4 mL of artificial CSF to purify an albumin solution with a concentration of 4.5 mM. Artificial CSF was added thereto, and eight types of albumin solutions, with concentrations of 0.002-4.5 mM, were purified. We acquired this albumin solution with CPMG pulses and NNLS, decomposed the T<sub>2</sub> values per pixel, and derived 25 T<sub>2</sub> component values of 60-2000 ms. We assessed the change of T<sub>2</sub> values by the difference in albumin concentration of a single voxel. Finally, we used the method to assess T<sub>2</sub> values from two patients, one with a subdural hematoma and one with a suprasellar cystic tumor. T<sub>2</sub> component values were plotted graphically, presented individually, and created in color maps.</p><p><strong>Results: </strong>T<sub>2</sub> component values for albumin concentrations ranging from 0.056 to 4.55 mM showed different T<sub>2</sub> peaks, whereas, for concentrations 0.002 to 0.019 mM, the peaks were similar heights and overlapped. Peak width was similar for all concentrations. The color maps successfully reflected the changes in T<sub>2</sub> values across both RGB color patterns. T<sub>2</sub> components for albumin samples with 2.5 mM and 6.1 mM concentrations within a single voxel were represented separately and reflected the ratio of the two samples in nine different regions of interest within one slice. In the clinical cases, the T<sub>2</sub> component map imaged differences in albumin concentrations, similar to those observed in the albumin samples.</p><p><strong>Conclusion: </strong>The present method with CPMG sequences and NNLS provide adequate images to differentiate accumulating protein concentrations in the CSF, even at the level of a single pixel.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142335331","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparing Lesion Conspicuity and ADC Reliability in High-resolution Diffusion-weighted Imaging of the Breast. 比较乳腺高分辨率弥散加权成像中病变的明显性和 ADC 可靠性
Mami Iima, Rena Nakayama, Masako Kataoka, Martins Otikovs, Noam Nissan, Lucio Frydman, Yuta Urushibata, Maya Honda, Aika Okazawa, Hiroko Satake, Shinji Naganawa, Yuji Nakamoto
{"title":"Comparing Lesion Conspicuity and ADC Reliability in High-resolution Diffusion-weighted Imaging of the Breast.","authors":"Mami Iima, Rena Nakayama, Masako Kataoka, Martins Otikovs, Noam Nissan, Lucio Frydman, Yuta Urushibata, Maya Honda, Aika Okazawa, Hiroko Satake, Shinji Naganawa, Yuji Nakamoto","doi":"10.2463/mrms.tn.2024-0089","DOIUrl":"https://doi.org/10.2463/mrms.tn.2024-0089","url":null,"abstract":"<p><strong>Purpose: </strong>This study investigated the breast lesion conspicuity and apparent diffusion coefficient (ADC) reliability for three different diffusion-weighted imaging (DWI) protocols: spatiotemporal encoding (SPEN), single-shot echo-planar imaging (SS-EPI), and readout segmentation of long variable echo-trains (RESOLVE).</p><p><strong>Methods: </strong>Sixty-five women suspected of having breast tumors were included in this study, with 44 lesions (36 malignant, 8 benign) analyzed further. Breast MRI was performed on a 3 Tesla (3T) system (MAGNETOM Prisma, Siemens) equipped with a dedicated 18-channel breast array coil for a phantom and patients. Three DWI protocols-SPEN, SS-EPI, and RESOLVE-were used. SS-EPI was acquired with an in-plane resolution of 2 × 2 mm<sup>2</sup>, a slice thickness of 3 mm, and b-values of 0 and 1000 s/mm<sup>2</sup>. SPEN had a higher in-plane resolution of 1 × 1 mm<sup>2</sup>, a slice thickness of 1.5 mm, and b-values of 0, 850, and 1500 s/mm<sup>2</sup>. RESOLVE was acquired with an in-plane resolution of 1 × 1 mm<sup>2</sup>, a slice thickness of 1.5 mm, and b-values of 0 and 850 s/mm<sup>2</sup>. Lesion conspicuity and ADC values were evaluated.</p><p><strong>Results: </strong>The average lesion conspicuity scores were significantly higher for RESOLVE (3.54 ± 0.65) than for SPEN (3.07 ± 0.91) or SS-EPI (2.48 ± 0.78) (P < 0.01). The SPEN score was significantly higher than the SS-EPI score (P < 0.01). Phantom measurements indicated marginally lower ADC values for SPEN compared to SS-EPI and RESOLVE across all concentrations. The results revealed that SPEN (b = 0, 850, 1500 sec/mm<sup>2</sup>) yielded significantly lower ADC values compared to SPEN (b = 0, 850 sec/mm<sup>2</sup>) in malignant lesions (P < 0.01), with no significant difference observed between SPEN (b = 0, 850 sec/mm<sup>2</sup>), SS-EPI, and RESOLVE. For benign lesions, no significant difference in ADC values was found between SPEN (b = 0, 850 sec/mm<sup>2</sup>), SPEN (b = 0, 850, 1500 sec/mm<sup>2</sup>), SS-EPI, and RESOLVE.</p><p><strong>Conclusion: </strong>RESOLVE provided the highest lesion conspicuity, and ADC values in breast lesions were not significantly different among sequences ranging b values 850-1000 sec/mm<sup>2</sup>. SPEN with higher b-values (0, 850, 1500 vs. 0, 850 sec/mm<sup>2</sup>) yielded significantly lower ADC values in malignant lesions, highlighting the importance of b-value selection in ADC quantification.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142335332","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Utility of Apparent Water Diffusion Coefficient Maps for Evaluating the Presence of Myometrial Invasion in Patients with Endometrial Cancer. 表观水扩散系数图在评估子宫内膜癌患者是否存在子宫肌层浸润方面的实用性
Miki Yoshida, Tsukasa Saida, Saki Shibuki, Toshitaka Ishiguro, Masafumi Sakai, Taishi Amano, Toyomi Satoh, Takahito Nakajima
{"title":"The Utility of Apparent Water Diffusion Coefficient Maps for Evaluating the Presence of Myometrial Invasion in Patients with Endometrial Cancer.","authors":"Miki Yoshida, Tsukasa Saida, Saki Shibuki, Toshitaka Ishiguro, Masafumi Sakai, Taishi Amano, Toyomi Satoh, Takahito Nakajima","doi":"10.2463/mrms.mp.2024-0048","DOIUrl":"https://doi.org/10.2463/mrms.mp.2024-0048","url":null,"abstract":"<p><strong>Purpose: </strong>To assess the utility of apparent diffusion coefficient maps (ADC) for diagnosing myometrial invasion (MI) in endometrial cancer (EC).</p><p><strong>Methods: </strong>This retrospective study included 164 patients (mean age, 56 years; range, 25-89 years) who underwent preoperative MRI for EC with <1/2 MI or no MI between April 2016 and July 2023. Five sequences were evaluated: T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), ADC, dynamic contrast-enhanced T1-weighted imaging (DCE-T1WI), and contrast-enhanced T1WI (CE-T1WI). Three experienced radiologists independently assessed the sequences for MI. For ADC, MI was determined if the endometrial-myometrial junction-tumor boundary had disappeared. Additionally, the assessment of MI was performed using the combination of T2WI, DWI, and ADC, as well as T2WI, DCE-T1WI, and CE-T1WI. The sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve (AUC) for the presence of MI were calculated and compared between the sequences and combinations. Inter-reader agreement was assessed using kappa (κ) statistics.</p><p><strong>Results: </strong>The sensitivity of ADC was significantly higher than T2WI (P < 0.001) and DCE-T1WI (P = 0.018) for one reader and significantly higher than CE-T1WI (P = 0.045 and 0.043) for two readers. The specificity of ADC was significantly lower than T2WI (P = 0.015 and < 0.001) and CE-T1WI (P = 0.031 and 0.01) for two readers and significantly lower than DCE-T1WI (P = 0.031) for one reader. The AUC of ADC was significantly higher than T2WI (P = 0.048) and DCE-T1WI (P = 0.049) for one reader. The combination including ADC showed higher positive predictive value for all three readers compared to any sequence or combination including contrast enhancement. Additionally, ADC demonstrated the highest agreement rates.</p><p><strong>Conclusion: </strong>ADC had high sensitivity for MI and the highest agreement rate among all sequences. Thus, this sequence, combined with other sequences, can be crucial for a comprehensive evaluation of MI.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142309537","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fast Non-contrast MR Angiography Using a Zigzag Centric ky - kz k-space Trajectory and Exponential Refocusing Flip Angles with Restoration of Longitudinal Magnetization. 利用之字形中心 ky - kz k 空间轨迹和指数重聚焦翻转角度恢复纵向磁化,实现快速非对比 MR 血管造影。
Vadim Malis, Diana Vucevic, Won C Bae, Asako Yamamoto, Yoshimori Kassai, John Lane, Albert Hsiao, Katsumi Nakamura, Mitsue Miyazaki
{"title":"Fast Non-contrast MR Angiography Using a Zigzag Centric k<sub>y</sub> - k<sub>z</sub> k-space Trajectory and Exponential Refocusing Flip Angles with Restoration of Longitudinal Magnetization.","authors":"Vadim Malis, Diana Vucevic, Won C Bae, Asako Yamamoto, Yoshimori Kassai, John Lane, Albert Hsiao, Katsumi Nakamura, Mitsue Miyazaki","doi":"10.2463/mrms.mp.2023-0158","DOIUrl":"10.2463/mrms.mp.2023-0158","url":null,"abstract":"<p><strong>Purpose: </strong>Fresh blood imaging (FBI) utilizes physiological blood signal differences between diastole and systole, causing a long acquisition time. The purpose of this study is to develop a fast FBI technique using a centric k<sub>y</sub> - k<sub>z</sub> k-space trajectory (cFBI) and an exponential refocusing flip angle (eFA) scheme with fast longitudinal restoration.</p><p><strong>Methods: </strong>This study was performed on 8 healthy subjects and 2 patients (peripheral artery disease and vascular disease) with informed consent, using a clinical 3-Tesla MRI scanner. A numeric simulation using extended phase graph (EPG) and phantom studies of eFA were carried out to investigate the restoration of longitudinal signal by lowering refocusing flip angles in later echoes. cFBI was then acquired on healthy subjects at the popliteal artery station to assess the effect of varying high/low flip ratios on the longitudinal restoration effects. In addition, trigger-delays of cFBI were optimized owing to the long acquisition window in zigzag centric k<sub>y</sub> - k<sub>z</sub> k-space trajectory. After optimizations, cFBI images were compared against standard FBI (sFBI) images in terms of scan time, motion artifacts, Nyquist N/2 artifacts, blurring, and overall image quality. We also performed two-way repeated measures analysis of variance.</p><p><strong>Results: </strong>cFBI with eFA achieved nearly a 50% scan time reduction compared to sFBI. The high/low flip angle of 180/2 degrees with lower refocusing pulses shows fast longitudinal restoration with the highest blood signals, yet also more sensitive to the background signals. Overall, 180/30 degrees images show reasonable blood signal recovery while minimizing the background signal artifacts. After the trigger delay optimization, maximum intensity projection image of cFBI after systole-diastole subtraction demonstrates less motion and N/2 artifacts than that of sFBI.</p><p><strong>Conclusion: </strong>Together with eFA for fast longitudinal signal restoration, the proposed cFBI technique achieved a 2-fold reduction in scan time and improved image quality without major artifacts.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142134946","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of Benign, Borderline, and Malignant Ovarian Seromucinous Neoplasms on MR Imaging. 核磁共振成像中良性、边缘性和恶性卵巢浆液性肿瘤的比较。
Tsukasa Saida, Miki Yoshida, Toshitaka Ishiguro, Sodai Hoshiai, Masafumi Sakai, Taishi Amano, Saki Shibuki, Toyomi Satoh, Takahito Nakajima
{"title":"Comparison of Benign, Borderline, and Malignant Ovarian Seromucinous Neoplasms on MR Imaging.","authors":"Tsukasa Saida, Miki Yoshida, Toshitaka Ishiguro, Sodai Hoshiai, Masafumi Sakai, Taishi Amano, Saki Shibuki, Toyomi Satoh, Takahito Nakajima","doi":"10.2463/mrms.mp.2024-0064","DOIUrl":"https://doi.org/10.2463/mrms.mp.2024-0064","url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to compare MRI findings among benign, borderline, and malignant ovarian seromucinous neoplasms.</p><p><strong>Methods: </strong>We retrospectively analyzed MRI data from 24 patients with ovarian seromucinous neoplasms-seven benign, thirteen borderline, and six malignant. The parameters evaluated included age, tumour size, morphology, number, height, apparent diffusion coefficient (ADC) values, T2 ratios, time-intensity curve (TIC) descriptors, and TIC patterns of the mural nodules. Additionally, we examined the T2 and T1 ratios of the cyst contents, tumour markers, and the presence of endometriosis. We used statistical tests, including the Kruskal-Wallis and Fisher-Freeman-Halton exact tests, to compare these parameters among the three aforementioned groups.</p><p><strong>Results: </strong>The cases showed papillary architecture with internal branching in 57% of benign, 92% of borderline, and 17% of malignant cases. Three or fewer mural nodules were seen in 57% of benign, 8% of borderline, and 17% of malignant cases. Compared to benign and borderline tumours, mural nodules of malignant neoplasms had significantly increased height (P = 0.015 and 0.011, respectively), lower means ADC values (P = 0.003 and 0.035, respectively). The mural nodules in malignant cases also demonstrated significantly lower T2 ratios than those in the benign cases (P = 0.045). Most neoplasms displayed an intermediate-risk TIC pattern, including 80% benign, 83% borderline, and 60% malignant neoplasms, and no significant differences were observed.</p><p><strong>Conclusion: </strong>Most benign and borderline tumours exhibited a papillary architecture with an internal branching pattern, whereas this feature was less common in malignant neoplasms. Additionally, benign tumours had fewer mural nodules compared to borderline tumours. Malignant neoplasms were characterized by mural nodules with increased height and lower ADC values than those in benign and borderline tumours. Interestingly, all three groups predominantly exhibited an intermediate-risk TIC pattern, emphasizing the complexity of diagnosing seromucinous neoplasms using MRI.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142116621","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study of Power Equivalent Continuous Approximation Based on the Recent Consensus Recommendations for Brain Tumor Imaging with Pulsed Chemical Exchange Saturation Transfer at 3T. 基于3T下脉冲化学交换饱和转移脑肿瘤成像最新共识建议的功率等效连续近似值研究
Swee Qi Pan, Yan Chai Hum, Khin Wee Lai, Wun-She Yap, Chi Wei Ong, Yee Kai Tee
{"title":"Study of Power Equivalent Continuous Approximation Based on the Recent Consensus Recommendations for Brain Tumor Imaging with Pulsed Chemical Exchange Saturation Transfer at 3T.","authors":"Swee Qi Pan, Yan Chai Hum, Khin Wee Lai, Wun-She Yap, Chi Wei Ong, Yee Kai Tee","doi":"10.2463/mrms.tn.2024-0069","DOIUrl":"https://doi.org/10.2463/mrms.tn.2024-0069","url":null,"abstract":"<p><p>The quantitative analysis of pulsed-chemical exchange saturation transfer (CEST) using a full model-based method is computationally challenging, as it involves dealing with varying RF values in pulsed saturation. A power equivalent continuous approximation of B<sub>1</sub> power was usually applied to accelerate the analysis. In line with recent consensus recommendations from the CEST community for pulsed-CEST at 3T, particularly recommending a high RF saturation power (B<sub>1</sub> = 2.0 µT) for the clinical application in brain tumors, this technical note investigated the feasibility of using average power (AP) as the continuous approximation. The simulated results revealed excellent performance of the AP continuous approximation in low saturation power scenarios, but discrepancies were observed in the z-spectra for the high saturation power cases. Cautions should be taken, or it may lead to inaccurate fitted parameters, and the difference can be more than 10% in the high saturation power cases.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141984262","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Diffusion-weighted Echo Planar Imaging with Compressed SENSE (EPICS-DWI) for Pancreas Assessment: A Multicenter Study. 弥散加权回波平面成像与压缩 SENSE(EPICS-DWI)用于胰腺评估:一项多中心研究。
Tetsuro Kaga, Yoshifumi Noda, Masashi Asano, Nobuyuki Kawai, Kimihiro Kajita, Yukiko Takai, Fumitaka Ejima, Fuminori Hyodo, Hiroki Kato, Yoshihiko Fukukura, Masayuki Matsuo
{"title":"Diffusion-weighted Echo Planar Imaging with Compressed SENSE (EPICS-DWI) for Pancreas Assessment: A Multicenter Study.","authors":"Tetsuro Kaga, Yoshifumi Noda, Masashi Asano, Nobuyuki Kawai, Kimihiro Kajita, Yukiko Takai, Fumitaka Ejima, Fuminori Hyodo, Hiroki Kato, Yoshihiko Fukukura, Masayuki Matsuo","doi":"10.2463/mrms.mp.2024-0046","DOIUrl":"https://doi.org/10.2463/mrms.mp.2024-0046","url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the feasibility of single-shot echo planar diffusion-weighted imaging with compressed SENSE (EPICS-DWI) for pancreas assessment by comparing with single-shot echo planar DWI with parallel imaging (PI-DWI).</p><p><strong>Methods: </strong>This multicenter prospective study included 27 consecutive participants with untreated pancreatic ductal adenocarcinoma (PDAC) (15 men; mean age, 67 ± 10 years) who underwent pancreatic protocol MRI including both PI-DWI and EPICS-DWI. Two radiologists independently and randomly reviewed the high b-value DWI images and qualitatively assigned confidence scores for overall image quality, image noise, pancreas conspicuity, and PDAC conspicuity using a 5-point scale. One radiologist measured the PDAC-to-pancreas contrast-to-noise-ratio (CNR) on high b-value DWI images and the apparent diffusion coefficient (ADC) value of PDAC. Qualitative and quantitative parameters were compared between PI-DWI and EPICS-DWI using the Wilcoxon signed-rank test.</p><p><strong>Results: </strong>The confidence scores for overall image quality (P < 0.001 in both radiologists) and image noise (P < 0.001 in both radiologists) were higher in EPICS-DWI than in PI-DWI. The pancreas conspicuity was better in EPICS-DWI than in PI-DWI in one of the radiologists (P = 0.02 and 0.06). The PDAC conspicuity was comparable between PI-DWI and EPICS-DWI (P > 0.99 in both radiologists). The PDAC-to-pancreas CNR was higher in EPICS-DWI than in PI-DWI (P = 0.02), while the ADC value of PDAC in PI-DWI was not significantly different compared to that in EPICS-DWI (P = 0.48).</p><p><strong>Conclusion: </strong>The image quality and PDAC-to-pancreas CNR was improved in EPICS-DWI compared to PI-DWI. However, the conspicuity and ADC value of PDAC were comparable between PI-DWI and EPICS-DWI.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141904064","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Utility of Echo-planar Imaging with Compressed Sensitivity Encoding (EPICS) in the Evaluation of Small Breast Cancers Using Diffusion-weighted Imaging with Background Suppression (DWIBS). 使用带背景抑制的扩散加权成像(DWIBS)的压缩灵敏度编码回声平面成像(EPICS)在评估小乳腺癌中的实用性。
Toshiki Kazama, Yui Nagafuji, Naoki Niikura, Takuho Okamura, Marc Van Cauteren, Makoto Obara, Susumu Takano, Natsuo Konta, Tomohiko Horie, Taro Takahara, Nobue Kumaki, Tetsu Niwa, Jun Hashimoto
{"title":"Utility of Echo-planar Imaging with Compressed Sensitivity Encoding (EPICS) in the Evaluation of Small Breast Cancers Using Diffusion-weighted Imaging with Background Suppression (DWIBS).","authors":"Toshiki Kazama, Yui Nagafuji, Naoki Niikura, Takuho Okamura, Marc Van Cauteren, Makoto Obara, Susumu Takano, Natsuo Konta, Tomohiko Horie, Taro Takahara, Nobue Kumaki, Tetsu Niwa, Jun Hashimoto","doi":"10.2463/mrms.mp.2023-0151","DOIUrl":"https://doi.org/10.2463/mrms.mp.2023-0151","url":null,"abstract":"<p><strong>Purpose: </strong>High b-value acquisition and diffusion-weighted imaging with background suppression (DWIBS) are desirable in high-specificity breast cancer diagnosis on non-contrast-enhanced magnetic resonance imaging; however, this inherently results in a lower signal-to-noise ratio (SNR). Compressed sensitivity encoding (C-SENSE), which combines SENSE with compressed sensing, improves the SNR by reducing noise. Recent technological improvements allow us to incorporate this acceleration technique into echo-planar imaging, called echo-planar imaging with C-SENSE (EPICS). This study aimed to compare image quality and reliability of the apparent diffusion coefficient (ADC) between DWIBS obtained using SENSE and EPICS in patients with small breast cancers.</p><p><strong>Methods: </strong>Thirty-seven patients with pathologically confirmed breast cancer underwent DWIBS, and images were reconstructed using both conventional SENSE (SENSE-DWIBS) and EPICS (EPICS-DWIBS). Two board-certified radiologists independently evaluated lesion conspicuity (LC) and noise using a 5-point grading scale. The same 2 radiologists independently measured SNR, contrast-to-noise ratio (CNR), and the mean cancer ADC. The Pearson coefficient and Bland-Altman plot were applied to assess the accuracy of ADCs.</p><p><strong>Results: </strong>LC scores were higher with EPICS than with SENSE, reaching significance for one reviewer but not the other reviewer. Noise ratings on visual evaluation were significantly lower with EPICS than with SENSE (P < 0.001 for both reviewers). SNR was significantly higher with EPICS than with SENSE (P < 0.005 for both reviewers). CNR was significantly higher with EPICS than with SENSE (P < 0.001 for both reviewers). Bland-Altman plots of cancer ADCs using EPICS-DWIBS and SENSE-DWIBS showed excellent concordance, with a bias of 0.026 × 10<sup>-3</sup> mm<sup>2</sup>/s and limits of agreement ranging 0.054 × 10<sup>-3</sup> mm<sup>2</sup>/s; the Pearson's correlation coefficient was 0.997 (P < 0.0001).</p><p><strong>Conclusion: </strong>EPICS enhances breast DWIBS image quality, with improved SNR and CNR and reduced noise levels. The ADCs of breast cancers obtained using EPICS were almost perfectly correlated with those obtained using conventional SENSE.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141790677","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
High Resolution TOF-MRA Using Compressed Sensing-based Deep Learning Image Reconstruction for the Visualization of Lenticulostriate Arteries: A Preliminary Study. 利用基于压缩传感的深度学习图像重建技术实现睑动脉可视化的高分辨率 TOF-MRA:初步研究。
Yuya Hirano, Noriyuki Fujima, Hiroyuki Kameda, Kinya Ishizaka, Jihun Kwon, Masami Yoneyama, Kohsuke Kudo
{"title":"High Resolution TOF-MRA Using Compressed Sensing-based Deep Learning Image Reconstruction for the Visualization of Lenticulostriate Arteries: A Preliminary Study.","authors":"Yuya Hirano, Noriyuki Fujima, Hiroyuki Kameda, Kinya Ishizaka, Jihun Kwon, Masami Yoneyama, Kohsuke Kudo","doi":"10.2463/mrms.mp.2024-0025","DOIUrl":"https://doi.org/10.2463/mrms.mp.2024-0025","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the visibility of the lenticulostriate arteries (LSAs) in time-of-flight (TOF)-MR angiography (MRA) using compressed sensing (CS)-based deep learning (DL) image reconstruction by comparing its image quality with that obtained by the conventional CS algorithm.</p><p><strong>Methods: </strong>Five healthy volunteers were included. High-resolution TOF-MRA images with the reduction (R)-factor of 1 were acquired as full-sampling data. Images with R-factors of 2, 4, and 6 were then reconstructed using CS-DL and conventional CS (the combination of CS and sensitivity conceding; CS-SENSE) reconstruction, respectively. In the quantitative assessment, the number of visible LSAs (identified by two radiologists), length of each depicted LSA (evaluated by one radiological technologist), and normalized mean squared error (NMSE) value were assessed. In the qualitative assessment, the overall image quality and the visibility of the peripheral LSA were visually evaluated by two radiologists.</p><p><strong>Results: </strong>In the quantitative assessment of the DL-CS images, the number of visible LSAs was significantly higher than those obtained with CS-SENSE in the R-factors of 4 and 6 (Reader 1) and in the R-factor of 6 (Reader 2). The length of the depicted LSAs in the DL-CS images was significantly longer in the R-factor 6 compared to the CS-SENSE result. The NMSE value in CS-DL was significantly lower than in CS-SENSE for R-factors of 4 and 6. In the qualitative assessment of DL-CS images, the overall image quality was significantly higher than that obtained with CS-SENSE in the R-factors 4 and 6 (Reader 1) and in the R-factor 4 (Reader 2). The visibility of the peripheral LSA was significantly higher than that shown by CS-SENSE in all R-factors (Reader 1) and in the R-factors 2 and 4 (Reader 2).</p><p><strong>Conclusion: </strong>CS-DL reconstruction demonstrated preserved image quality for the depiction of LSAs compared to the conventional CS-SENSE when the R-factor is elevated.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141736204","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信