超快乳腺磁共振成像的机构可变性:比较不同患者群体和造影剂注射方案的压缩感知和视图共享技术。

Maya Honda, Masako Kataoka, Mami Iima, Rie Ota, Aika Okazawa, Yasuhiro Fukushima, Marcel Dominik Nickel, Fumiaki Sato, Norikazu Masuda, Tsutomu Okada, Yuji Nakamoto
{"title":"超快乳腺磁共振成像的机构可变性:比较不同患者群体和造影剂注射方案的压缩感知和视图共享技术。","authors":"Maya Honda, Masako Kataoka, Mami Iima, Rie Ota, Aika Okazawa, Yasuhiro Fukushima, Marcel Dominik Nickel, Fumiaki Sato, Norikazu Masuda, Tsutomu Okada, Yuji Nakamoto","doi":"10.2463/mrms.mp.2024-0152","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the institutional variability in ultrafast dynamic contrast-enhanced (UF-DCE) breast MRI using time-resolved angiography with stochastic trajectories (TWIST)-volumetric interpolated breath-hold examination (VIBE) and compressed sensing (CS)-VIBE sequences acquired at 2 different institutions with different patient populations and contrast injection protocols.</p><p><strong>Methods: </strong>UF-DCE MR images of 18 patients from site A acquired using a TWIST-VIBE sequence, and UF-DCE MR images of 18 patients from site B acquired with a CS-VIBE sequence, were retrospectively evaluated and compared. The 2-site patient cohort was matched for patient age, background parenchymal enhancement, malignancy or benignity, and lesion size. Qualitative assessments included noise, blurring, poor fat suppression, aliasing artifact, motion artifact, lesion conspicuity, lesion morphology, time-intensity-curve smoothness, and vessel delineation. For quantitative assessment, the bolus arrival time was evaluated for each lesion, and its diagnostic performance in discriminating between benign and malignant lesions was examined using receiver operating characteristics analysis.</p><p><strong>Results: </strong>Thirteen malignant and five benign lesions were included from each site. Qualitative evaluation revealed that poor fat suppression and aliasing artifacts were visible in images from site A with TWIST-VIBE (P = 0.004 and P < 0.001), whereas motion artifacts were present in images from site B with CS-VIBE (P = 0.04). Lesion morphology assessments (P < 0.001) and vessel delineation (P < 0.001) were superior for images from site B with CS-VIBE. Bolus arrival time was significantly longer with TWIST-VIBE than with CS-VIBE, for both benign and malignant lesions (P < 0.001). The area under the receiver operating characteristics curve was 0.55 for site A and 0.69 for site B (P = 0.39).</p><p><strong>Conclusion: </strong>Both acquisitions allowed evaluation of breast lesions with good lesion conspicuity and time-intensity-curve smoothness, whereas CS-VIBE was superior to TWIST-VIBE for morphological evaluation of breast lesions and depiction of blood vessels in the breast. Injection rate appears to have a significant impact on semi-quantitative parameters derived from UF-DCE MRI.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Institutional Variability in Ultrafast Breast MR Imaging: Comparing Compressed Sensing and View Sharing Techniques with Different Patient Populations and Contrast Injection Protocols.\",\"authors\":\"Maya Honda, Masako Kataoka, Mami Iima, Rie Ota, Aika Okazawa, Yasuhiro Fukushima, Marcel Dominik Nickel, Fumiaki Sato, Norikazu Masuda, Tsutomu Okada, Yuji Nakamoto\",\"doi\":\"10.2463/mrms.mp.2024-0152\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the institutional variability in ultrafast dynamic contrast-enhanced (UF-DCE) breast MRI using time-resolved angiography with stochastic trajectories (TWIST)-volumetric interpolated breath-hold examination (VIBE) and compressed sensing (CS)-VIBE sequences acquired at 2 different institutions with different patient populations and contrast injection protocols.</p><p><strong>Methods: </strong>UF-DCE MR images of 18 patients from site A acquired using a TWIST-VIBE sequence, and UF-DCE MR images of 18 patients from site B acquired with a CS-VIBE sequence, were retrospectively evaluated and compared. The 2-site patient cohort was matched for patient age, background parenchymal enhancement, malignancy or benignity, and lesion size. Qualitative assessments included noise, blurring, poor fat suppression, aliasing artifact, motion artifact, lesion conspicuity, lesion morphology, time-intensity-curve smoothness, and vessel delineation. For quantitative assessment, the bolus arrival time was evaluated for each lesion, and its diagnostic performance in discriminating between benign and malignant lesions was examined using receiver operating characteristics analysis.</p><p><strong>Results: </strong>Thirteen malignant and five benign lesions were included from each site. Qualitative evaluation revealed that poor fat suppression and aliasing artifacts were visible in images from site A with TWIST-VIBE (P = 0.004 and P < 0.001), whereas motion artifacts were present in images from site B with CS-VIBE (P = 0.04). Lesion morphology assessments (P < 0.001) and vessel delineation (P < 0.001) were superior for images from site B with CS-VIBE. Bolus arrival time was significantly longer with TWIST-VIBE than with CS-VIBE, for both benign and malignant lesions (P < 0.001). The area under the receiver operating characteristics curve was 0.55 for site A and 0.69 for site B (P = 0.39).</p><p><strong>Conclusion: </strong>Both acquisitions allowed evaluation of breast lesions with good lesion conspicuity and time-intensity-curve smoothness, whereas CS-VIBE was superior to TWIST-VIBE for morphological evaluation of breast lesions and depiction of blood vessels in the breast. Injection rate appears to have a significant impact on semi-quantitative parameters derived from UF-DCE MRI.</p>\",\"PeriodicalId\":94126,\"journal\":{\"name\":\"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2463/mrms.mp.2024-0152\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2024-0152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:利用随机轨迹时间分辨血管造影(TWIST)-容积内插屏气检查(VIBE)和压缩感知(CS)-VIBE序列,评估超快动态对比增强(UF-DCE)乳房MRI的机构差异,这些序列来自两家不同机构,不同患者群体和对比剂注射方案。方法:采用TWIST-VIBE序列获得18例A部位患者的UF-DCE MR图像,并采用CS-VIBE序列获得18例B部位患者的UF-DCE MR图像,对其进行回顾性评估和比较。2点患者队列根据患者年龄、背景实质增强、恶性或良性以及病变大小进行匹配。定性评估包括噪音、模糊、脂肪抑制不良、混叠伪影、运动伪影、病变显著性、病变形态、时间-强度曲线平滑度和血管描绘。为了定量评估,我们评估了每个病变的丸剂到达时间,并通过接受者操作特征分析来检验其在区分良恶性病变方面的诊断性能。结果:每个部位包括13个恶性病变和5个良性病变。定性评价显示,TWIST-VIBE在A部位的图像中可以看到较差的脂肪抑制和混叠伪影(P = 0.004和P)。结论:两种采集都可以评估乳腺病变,病变的显著性和时间-强度曲线的平滑性都很好,而CS-VIBE在乳腺病变的形态学评估和乳腺血管的描绘方面优于TWIST-VIBE。注射速率似乎对UF-DCE MRI得出的半定量参数有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Institutional Variability in Ultrafast Breast MR Imaging: Comparing Compressed Sensing and View Sharing Techniques with Different Patient Populations and Contrast Injection Protocols.

Purpose: To assess the institutional variability in ultrafast dynamic contrast-enhanced (UF-DCE) breast MRI using time-resolved angiography with stochastic trajectories (TWIST)-volumetric interpolated breath-hold examination (VIBE) and compressed sensing (CS)-VIBE sequences acquired at 2 different institutions with different patient populations and contrast injection protocols.

Methods: UF-DCE MR images of 18 patients from site A acquired using a TWIST-VIBE sequence, and UF-DCE MR images of 18 patients from site B acquired with a CS-VIBE sequence, were retrospectively evaluated and compared. The 2-site patient cohort was matched for patient age, background parenchymal enhancement, malignancy or benignity, and lesion size. Qualitative assessments included noise, blurring, poor fat suppression, aliasing artifact, motion artifact, lesion conspicuity, lesion morphology, time-intensity-curve smoothness, and vessel delineation. For quantitative assessment, the bolus arrival time was evaluated for each lesion, and its diagnostic performance in discriminating between benign and malignant lesions was examined using receiver operating characteristics analysis.

Results: Thirteen malignant and five benign lesions were included from each site. Qualitative evaluation revealed that poor fat suppression and aliasing artifacts were visible in images from site A with TWIST-VIBE (P = 0.004 and P < 0.001), whereas motion artifacts were present in images from site B with CS-VIBE (P = 0.04). Lesion morphology assessments (P < 0.001) and vessel delineation (P < 0.001) were superior for images from site B with CS-VIBE. Bolus arrival time was significantly longer with TWIST-VIBE than with CS-VIBE, for both benign and malignant lesions (P < 0.001). The area under the receiver operating characteristics curve was 0.55 for site A and 0.69 for site B (P = 0.39).

Conclusion: Both acquisitions allowed evaluation of breast lesions with good lesion conspicuity and time-intensity-curve smoothness, whereas CS-VIBE was superior to TWIST-VIBE for morphological evaluation of breast lesions and depiction of blood vessels in the breast. Injection rate appears to have a significant impact on semi-quantitative parameters derived from UF-DCE MRI.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信