细胞内对比度增强脂肪饱和 T1 加权梯度回波(ICE-TIGRE)序列的性质:脂肪抑制 T1 加权技术与运动敏化驱动平衡用于改善肝脏成像的对比度增强。

Takashi Nishihara, Yuko Nakamura, Nobuyuki Yoshizawa, Masahiro Takizawa, Toru Shirai, Toru Higaki, Yukiko Honda, Kazuo Awai, Yoshitaka Bito
{"title":"细胞内对比度增强脂肪饱和 T1 加权梯度回波(ICE-TIGRE)序列的性质:脂肪抑制 T1 加权技术与运动敏化驱动平衡用于改善肝脏成像的对比度增强。","authors":"Takashi Nishihara, Yuko Nakamura, Nobuyuki Yoshizawa, Masahiro Takizawa, Toru Shirai, Toru Higaki, Yukiko Honda, Kazuo Awai, Yoshitaka Bito","doi":"10.2463/mrms.tn.2023-0104","DOIUrl":null,"url":null,"abstract":"<p><p>Gadoxetic acid is both an extracellular- and hepatocyte-specific contrast agent. Signals from the extracellular space may lower the contrast between lesions and the surrounding hepatic parenchyma. To improve hepatocyte-specific enhancement, we developed an intracellular contrast-enhancing fat-saturated T1-weighted gradient-echo nature of the sequence (ICE-TIGRE). It incorporates the motion-sensitized driven-equilibrium (MSDE) pulse to suppress signals from the blood flow. We investigated the optimal ICE-TIGRE scanning parameters, i.e., the order of the MSDE and the fat saturation pulses, the duration time, and the b value of the MSDE pulse, using a phantom and three volunteers without applying gadoxetic acid. ICE-TIGRE successfully increased the contrast between the liver parenchyma and the portal vein. To maintain fat saturation, the preparation pulse order should be MSDE-fat saturation. A duration time of 21 ms should be applied to minimize the effect of the T2 factor on the T1 contrast, and a b value of 60 s/mm<sup>2</sup> should be applied to maximize the diffusion contrast for ICE-TIGRE with the imaging system used in this study.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nature of the Intracellular-contrast-enhancing Fat-saturated T1-weighted Gradient-echo (ICE-TIGRE) Sequence: A Fat-suppressed T1-weighted Technique with Motion-sensitised Driven-equilibrium for Improved Contrast Enhancement in Liver Imaging.\",\"authors\":\"Takashi Nishihara, Yuko Nakamura, Nobuyuki Yoshizawa, Masahiro Takizawa, Toru Shirai, Toru Higaki, Yukiko Honda, Kazuo Awai, Yoshitaka Bito\",\"doi\":\"10.2463/mrms.tn.2023-0104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Gadoxetic acid is both an extracellular- and hepatocyte-specific contrast agent. Signals from the extracellular space may lower the contrast between lesions and the surrounding hepatic parenchyma. To improve hepatocyte-specific enhancement, we developed an intracellular contrast-enhancing fat-saturated T1-weighted gradient-echo nature of the sequence (ICE-TIGRE). It incorporates the motion-sensitized driven-equilibrium (MSDE) pulse to suppress signals from the blood flow. We investigated the optimal ICE-TIGRE scanning parameters, i.e., the order of the MSDE and the fat saturation pulses, the duration time, and the b value of the MSDE pulse, using a phantom and three volunteers without applying gadoxetic acid. ICE-TIGRE successfully increased the contrast between the liver parenchyma and the portal vein. To maintain fat saturation, the preparation pulse order should be MSDE-fat saturation. A duration time of 21 ms should be applied to minimize the effect of the T2 factor on the T1 contrast, and a b value of 60 s/mm<sup>2</sup> should be applied to maximize the diffusion contrast for ICE-TIGRE with the imaging system used in this study.</p>\",\"PeriodicalId\":94126,\"journal\":{\"name\":\"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2463/mrms.tn.2023-0104\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.tn.2023-0104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

钆醋酸既是细胞外造影剂,也是肝细胞特异性造影剂。来自细胞外空间的信号可能会降低病灶与周围肝实质之间的对比度。为了改善肝细胞特异性增强,我们开发了一种细胞内对比增强脂肪饱和 T1 加权梯度回波性质序列(ICE-TIGRE)。它结合了运动敏感驱动平衡(MSDE)脉冲来抑制血流信号。我们使用一个模型和三名志愿者,在不使用钆醋酸的情况下,研究了最佳的 ICE-TIGRE 扫描参数,即 MSDE 脉冲和脂肪饱和脉冲的顺序、持续时间和 MSDE 脉冲的 b 值。ICE-TIGRE 成功提高了肝实质与门静脉之间的对比度。为保持脂肪饱和度,准备脉冲的顺序应为 MSDE-脂肪饱和。持续时间应为 21 ms,以尽量减少 T2 因子对 T1 对比度的影响,b 值应为 60 s/mm2,以便在本研究使用的成像系统中使 ICE-TIGRE 的扩散对比度最大化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Nature of the Intracellular-contrast-enhancing Fat-saturated T1-weighted Gradient-echo (ICE-TIGRE) Sequence: A Fat-suppressed T1-weighted Technique with Motion-sensitised Driven-equilibrium for Improved Contrast Enhancement in Liver Imaging.

Gadoxetic acid is both an extracellular- and hepatocyte-specific contrast agent. Signals from the extracellular space may lower the contrast between lesions and the surrounding hepatic parenchyma. To improve hepatocyte-specific enhancement, we developed an intracellular contrast-enhancing fat-saturated T1-weighted gradient-echo nature of the sequence (ICE-TIGRE). It incorporates the motion-sensitized driven-equilibrium (MSDE) pulse to suppress signals from the blood flow. We investigated the optimal ICE-TIGRE scanning parameters, i.e., the order of the MSDE and the fat saturation pulses, the duration time, and the b value of the MSDE pulse, using a phantom and three volunteers without applying gadoxetic acid. ICE-TIGRE successfully increased the contrast between the liver parenchyma and the portal vein. To maintain fat saturation, the preparation pulse order should be MSDE-fat saturation. A duration time of 21 ms should be applied to minimize the effect of the T2 factor on the T1 contrast, and a b value of 60 s/mm2 should be applied to maximize the diffusion contrast for ICE-TIGRE with the imaging system used in this study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信