Computational Design of a Thermal Applicator for Brain Hyperthermia Controlled by Capacitor Positioning in Loop Coils.

Daniel Hernandez, Taewoo Nam, Eunwoo Lee, Yeunchul Ryu, Jun-Young Chung, Kyoung-Nam Kim
{"title":"Computational Design of a Thermal Applicator for Brain Hyperthermia Controlled by Capacitor Positioning in Loop Coils.","authors":"Daniel Hernandez, Taewoo Nam, Eunwoo Lee, Yeunchul Ryu, Jun-Young Chung, Kyoung-Nam Kim","doi":"10.2463/mrms.mp.2024-0086","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Hyperthermia is a treatment that applies heat to damage or kill cancer cells and can be also used for drug deliveries. It is important to apply the heat into the specific area in order to target the cancer tissue and avoid damaging healthy tissue. For this reason, the development of heat applicators that have the capability to deliver the heat to the target area is vital. In this study, we present an optimization of an array coil for brain hyperthermia that can be used in combination with MRI, such that the heat can be delivered to the cancer area.</p><p><strong>Methods: </strong>The array coils were based on optimizing loop coils by varying the capacitor's position along the perimeter. The optimization was performed using electromagnetic simulations, by computing the electric field (E) and temperature inside of the brain and targeting tumor tissues for focus temperature application. The coils were compared with a general-use symmetric coil array for head heating.</p><p><strong>Results: </strong>The optimization of the coil array was able to focus electric field and make temperature rise at the cancer areas. The temperature in Tumor 1 before and after standard and the proposed method optimization was 43.6°C, 48.3°C, and 42.5°C and for Tumor 2 the temperatures were 44.2°C, 43.1°C, and 42.9°C, respectively. Although the standard optimization method exhibits higher temperatures, it also had higher temperatures outside the tumors area.</p><p><strong>Conclusion: </strong>We demonstrated the optimization of array coils with different capacitor positions to obtain focused heating temperatures.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2024-0086","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Hyperthermia is a treatment that applies heat to damage or kill cancer cells and can be also used for drug deliveries. It is important to apply the heat into the specific area in order to target the cancer tissue and avoid damaging healthy tissue. For this reason, the development of heat applicators that have the capability to deliver the heat to the target area is vital. In this study, we present an optimization of an array coil for brain hyperthermia that can be used in combination with MRI, such that the heat can be delivered to the cancer area.

Methods: The array coils were based on optimizing loop coils by varying the capacitor's position along the perimeter. The optimization was performed using electromagnetic simulations, by computing the electric field (E) and temperature inside of the brain and targeting tumor tissues for focus temperature application. The coils were compared with a general-use symmetric coil array for head heating.

Results: The optimization of the coil array was able to focus electric field and make temperature rise at the cancer areas. The temperature in Tumor 1 before and after standard and the proposed method optimization was 43.6°C, 48.3°C, and 42.5°C and for Tumor 2 the temperatures were 44.2°C, 43.1°C, and 42.9°C, respectively. Although the standard optimization method exhibits higher temperatures, it also had higher temperatures outside the tumors area.

Conclusion: We demonstrated the optimization of array coils with different capacitor positions to obtain focused heating temperatures.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信