{"title":"TechRxiv: Share Your Preprint Research with the World!","authors":"","doi":"10.1109/TBCAS.2024.3464773","DOIUrl":"https://doi.org/10.1109/TBCAS.2024.3464773","url":null,"abstract":"","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"18 5","pages":"1190-1190"},"PeriodicalIF":0.0,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10695471","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142322031","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Together, We are advance technology","authors":"","doi":"10.1109/TBCAS.2024.3464777","DOIUrl":"https://doi.org/10.1109/TBCAS.2024.3464777","url":null,"abstract":"","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"18 5","pages":"1192-1192"},"PeriodicalIF":0.0,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10695158","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142324347","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"IEEE Circuits and Systems Society Information","authors":"","doi":"10.1109/TBCAS.2024.3464769","DOIUrl":"https://doi.org/10.1109/TBCAS.2024.3464769","url":null,"abstract":"","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"18 5","pages":"C3-C3"},"PeriodicalIF":0.0,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10695473","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142322032","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Blank Page","authors":"","doi":"10.1109/TBCAS.2024.3464771","DOIUrl":"https://doi.org/10.1109/TBCAS.2024.3464771","url":null,"abstract":"","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"18 5","pages":"C4-C4"},"PeriodicalIF":0.0,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10695472","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142324355","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Zhanghao Yu;Yiwei Zou;Huan-Cheng Liao;Fatima Alrashdan;Ziyuan Wen;Joshua E. Woods;Wei Wang;Jacob T. Robinson;Kaiyuan Yang
{"title":"A Miniature Batteryless Bioelectronic Implant Using One Magnetoelectric Transducer for Wireless Powering and PWM Backscatter Communication","authors":"Zhanghao Yu;Yiwei Zou;Huan-Cheng Liao;Fatima Alrashdan;Ziyuan Wen;Joshua E. Woods;Wei Wang;Jacob T. Robinson;Kaiyuan Yang","doi":"10.1109/TBCAS.2024.3468374","DOIUrl":"10.1109/TBCAS.2024.3468374","url":null,"abstract":"Wireless minimally invasive bioelectronic implants enable a wide range of applications in healthcare, medicine, and scientific research. Magnetoelectric (ME) wireless power transfer (WPT) has emerged as a promising approach for powering miniature bio-implants because of its remarkable efficiency, safety limit, and misalignment tolerance. However, achieving low-power and high-quality uplink communication using ME remains a challenge. This paper presents a pulse-width modulated (PWM) ME backscatter uplink communication enabled by a switched-capacitor energy extraction (SCEE) technique. The SCEE rapidly extracts and dissipates the kinetic energy within the ME transducer during its ringdown period, enabling time-domain PWM in ME backscatter. Various circuit techniques are presented to realize SCEE with low power consumption. This paper also describes the high-order modeling of ME transducers to facilitate the design and analysis, which shows good matching with measurement. Our prototyping system includes a millimeter-scale ME implant with a fully integrated system-on-chip (SoC) and a portable transceiver for power transfer and bidirectional communication. SCEE is proven to induce \u0000<inline-formula><tex-math>$>$</tex-math></inline-formula>\u0000 50% amplitude reduction within 2 ME cycles, leading to a PWM ME backscatter uplink with 17.73 kbps data rate and 0.9 pJ/bit efficiency. It also achieves 8.5\u0000<inline-formula><tex-math>$times$</tex-math></inline-formula>\u000010\u0000<sup>-5</sup>\u0000 bit-error-rate (BER) at a 5 cm distance, using a lightweight multi-layer-perception (MLP) decoding algorithm. Finally, the system demonstrates continuous wireless neural local-field potential (LFP) recording in an \u0000<italic>in vitro</i>\u0000 setup.","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"18 6","pages":"1197-1208"},"PeriodicalIF":0.0,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142335178","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"ACE: Automated Optimization Towards Iterative Classification in Edge Health Monitors","authors":"Yuxuan Wang;Lara Orlandic;Simone Machetti;Giovanni Ansaloni;David Atienza","doi":"10.1109/TBCAS.2024.3468160","DOIUrl":"https://doi.org/10.1109/TBCAS.2024.3468160","url":null,"abstract":"Wearable devices for health monitoring are essential for tracking individuals’ health status and facilitating early detection of diseases. However, processing biomedical signals online for real-time monitoring is challenging due to limited computational resources on edge devices. To address this challenge, we propose an application-agnostic methodology called ACE (Automated optimization towards classification on the Edge). ACE converts a health monitoring algorithm with feature extraction and classification into an iterative detection process, incorporating algorithms of varying complexities and minimizing re-computation of shared data. First, ACE decomposes a monolithic model, employing a single feature set and classifier, into multiple algorithms with different computational complexities. Then, our automatic analysis tool integrates buffering logic into these algorithms to prevent re-computation of shared computational-intensive data. The optimized algorithm is then converted into a low-level language in C for deployment. During runtime, the system initiates monitoring with the lowest complexity algorithm and iteratively involves algorithms with higher complexity without recomputing the existing data. The iteration process continues until a pre-defined confidence threshold is met. We demonstrate the effectiveness of ACE on two biomedical applications: seizure detection and emotional state classification. ACE achieves at least 28.9% and 18.9% runtime savings without any accuracy loss on a Cortex-A9 edge platform for the two benchmarks, respectively. We discuss and demonstrate how ACE can be used by designers of such biomedical algorithms to automatically optimize and deploy their applications on the edge.","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"19 1","pages":"82-92"},"PeriodicalIF":0.0,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143388655","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Minseong Um, Minil Kang, Kyeongho Eom, Hyunjeong Kwak, Kyungmi Noh, Jimin Lee, Jeonghoon Son, Jiseok Kwon, Seyoung Kim, Hyung-Min Lee
{"title":"A Multi-bit ECRAM-Based Analog Neuromorphic System with High-Precision Current Readout Achieving 97.3% Inference Accuracy.","authors":"Minseong Um, Minil Kang, Kyeongho Eom, Hyunjeong Kwak, Kyungmi Noh, Jimin Lee, Jeonghoon Son, Jiseok Kwon, Seyoung Kim, Hyung-Min Lee","doi":"10.1109/TBCAS.2024.3465610","DOIUrl":"https://doi.org/10.1109/TBCAS.2024.3465610","url":null,"abstract":"<p><p>This article proposes an analog neuromorphic system that enhances symmetry, linearity, and endurance by using a high-precision current readout circuit for multi-bit nonvolatile electro-chemical random-access memory (ECRAM). For on-chip training and inference, the system uses activation modules and matrix processing units to manage analog update/read paths and perform precise output sensing with feedback-based current scaling on the ECRAM array. The 250nm CMOS neuromorphic chip was tested with a 32 x 32 ECRAM synaptic array, achieving linear and symmetric updates and accurate read operations. The proposed circuit system updates the 32 x 32 ECRAM across 100 levels, maintaining consistent synaptic weights, and operates with an output error rate of up to 2.59% per column. It consumes 5.9 mW of power excluding the ECRAM array and achieves 97.3% inference accuracy on the MNIST dataset, close to the software-confirmed 97.78%, with only the final layer (64 x 10) mapped to the ECRAM.</p>","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"PP ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142309477","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Geunhaeng Lee, Junyoung Jang, Kyoungseok Song, Tae Wook Kim
{"title":"A 6-9 GHz 1.28 Gbps 76 mW Amplitude and Synchronized Time Shift Keying IR-UWB CMOS Transceiver for Brain Computer Interfaces.","authors":"Geunhaeng Lee, Junyoung Jang, Kyoungseok Song, Tae Wook Kim","doi":"10.1109/TBCAS.2024.3465533","DOIUrl":"https://doi.org/10.1109/TBCAS.2024.3465533","url":null,"abstract":"<p><p>This paper proposes a low-power, high-speed impulse radio-ultra-wideband (IR-UWB) transceiver for brain computer interfaces (BCIs) using amplitude and synchronized time shift keying technique (ASTSK). The proposed IR-UWB transmitter (Tx) generates two pulses (sync pulse and data pulse) per symbol rate. The time difference between two pulses is used for synchronized time shift keying and the amplitude of the two pulses is used for amplitude shift keying. The receiver (Rx) demodulates the time difference with a low power time-to-digital converter (TDC) and peak detector (PD) based amplitude demodulation is suggested to relax analog-to-digital converter (ADC) burden for low power receiver. Especially the Tx-based synchronized operation eliminates the need for complex clock circuitry such as phase-lock loop (PLL) and reference crystal oscillator. Therefore, it can achieve low power and high-speed operation. The prototype, fabricated in 65 nm CMOS, has a frequency range of 6-9 GHz, communication speed of 1.28 Gbps, and power consumption of 18 mW (Tx) and 58 mW (Rx). This work is a fully integrated RF transceiver adapted for high-order modulation and designed to include the receiver.</p>","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"PP ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142309475","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
G Spacone, S Vostrikov, V Kartsch, S Benatti, L Benini, A Cossettini
{"title":"Tracking of Wrist and Hand Kinematics with Ultra Low Power Wearable A-mode Ultrasound.","authors":"G Spacone, S Vostrikov, V Kartsch, S Benatti, L Benini, A Cossettini","doi":"10.1109/TBCAS.2024.3465239","DOIUrl":"10.1109/TBCAS.2024.3465239","url":null,"abstract":"<p><p>Ultrasound-based Hand Gesture Recognition has gained significant attention in recent years. While static gesture recognition has been extensively explored, only a few works have tackled the task of movement regression for real-time tracking, despite its importance for the development of natural and smooth interaction strategies. In this paper, we demonstrate the regression of 3 hand-wrist Degrees of Freedom (DoFs) using a lightweight, A-mode-based, truly wearable US armband featuring four transducers and WULPUS, an ultra-low-power acquisition device. We collect US data, synchronized with an optical motion capture system to establish a ground truth, from 5 subjects. We achieve state-of-the-art performance with an average root-mean-squared-error (RMSE) of 7.32◦ ± 1.97◦ and mean-absolute-error (MAE) of 5.31◦ ± 1.42◦. Additionally, we demonstrate, for the first time, robustness with respect to transducer repositioning between acquisition sessions, achieving an average RMSE value of 11.11◦ ± 4.14◦ and a MAE of 8.46◦ ± 3.58◦. Finally, we deploy our pipeline on a real-time low-power microcontroller, showcasing the first instance of multi-DoF regression based on A-mode US data on an embedded device, with a power consumption lower than 30mW and end-to-end latency of ≈ 80 ms.</p>","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"PP ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142309478","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jun Wang, Seok Joo Kim, Wenxuan Wu, Jongha Lee, Henry Hinton, Rona S Gertner, Han Sae Jung, Hongkun Park, Donhee Ham
{"title":"A Cyto-silicon Hybrid System with On-chip Closed-loop Modulation.","authors":"Jun Wang, Seok Joo Kim, Wenxuan Wu, Jongha Lee, Henry Hinton, Rona S Gertner, Han Sae Jung, Hongkun Park, Donhee Ham","doi":"10.1109/TBCAS.2024.3466549","DOIUrl":"https://doi.org/10.1109/TBCAS.2024.3466549","url":null,"abstract":"<p><p>We introduce a bioelectronic interface between biological electrogenic cells and a mixed-signal CMOS integrated circuit with an array of surface electrodes, where not only is the CMOS electrode array capable of electrophysiological recording and stimulation of the cells with 1,024 recording and stimulation channels, but it can also provide low-latency artificial signal pathways from cells it records to cells it stimulates. This on-chip closed-loop modulation has an intrinsic latency less than 5 μs. To demonstrate the utility of the on-chip closed loop modulation as an artificial feedback pathway between biological cells, we develop a silicon-cardiomyocyte self-sustained oscillator with a tunable frequency to which both the relevant part of the CMOS chip and cells are locked, and also a silicon-neuron interface with a silicon inhibitory connection between neuronal cells. This line of cyto-silicon hybrid system, where the boundary between biological and semiconductor systems is blurred, may find applications in prosthesis, brain-machine interface, and fundamental biology research.</p>","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"PP ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142309476","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}