Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine最新文献

筛选
英文 中文
Comparative analysis of fretting-corrosion at stem-cement and stem-head interfaces in stainless steel implants: Implications for adverse tissue reactions. 不锈钢种植体中茎-水泥和茎-头界面微动腐蚀的比较分析:对不良组织反应的影响。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-15 DOI: 10.1177/09544119251351193
Vinícius Oliveira Dos Santos, Patricia Ortega Cubillos, Cláudio Teodoro Dos Santos, Sheyla Santana de Carvalho, Wellington Gilbert Fernandes, Maurício de Jesus Monteiro, Ieda Maria Vieira Caminha, Carlos Rodrigo de Mello Roesler
{"title":"Comparative analysis of fretting-corrosion at stem-cement and stem-head interfaces in stainless steel implants: Implications for adverse tissue reactions.","authors":"Vinícius Oliveira Dos Santos, Patricia Ortega Cubillos, Cláudio Teodoro Dos Santos, Sheyla Santana de Carvalho, Wellington Gilbert Fernandes, Maurício de Jesus Monteiro, Ieda Maria Vieira Caminha, Carlos Rodrigo de Mello Roesler","doi":"10.1177/09544119251351193","DOIUrl":"10.1177/09544119251351193","url":null,"abstract":"<p><p>Degradation of implants by fretting-corrosion is the main source of released metal ions and debris, leading to adverse tissue reactions. Cemented stems have two interfaces that could be degraded: stem-cement and stem-head. This study aimed to identify which interface suffers the most severe degradation and, for this reason, is potentially more harmful to the human body. For this purpose, six pairs of stems and femoral heads made of stainless steel were divided into two groups according to the interface to be evaluated: I (stem-cement) and II (stem-head). The implants of both groups were subjected to a fretting-corrosion test, applying cyclic loading in corrosive environment for five million cycles. Fretting-corrosion mechanism was evaluated using electrochemical tests, optical microscopy, SEM/EDS analysis, and ions and particles analysis. The fretting current of the stem-cement interfaces was greater than that of the stem-head interfaces. SEM analysis showed the occurrence of corrosion and wear mechanisms, which are found in many published cases of retrieval analyses, indicating that there is a correlation between the mechanisms identified in benchtop test and those in retrieved stems. The amount of particles released in both interfaces was similar to that identified in retrieval analyses. For the stem-cement interface, the amount of particles released was higher than that associated with the stem-head interface. The stem-cement interface resulted in a greater release of ions than the stem-head interface. This reinforces the hypothesis that stem degradation at the stem-cement interface could be more harmful to the human body than that at the stem-head interface.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"706-718"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144637868","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Flow analysis comparison of network solid and sheet solid structures for Schwarz Primitive. Schwarz Primitive网固和片固结构的流动分析比较。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-07 DOI: 10.1177/09544119251348696
Derya Karaman, Hojjat Ghahramanzadeh Asl
{"title":"Flow analysis comparison of network solid and sheet solid structures for Schwarz Primitive.","authors":"Derya Karaman, Hojjat Ghahramanzadeh Asl","doi":"10.1177/09544119251348696","DOIUrl":"10.1177/09544119251348696","url":null,"abstract":"<p><p>Scaffolds developed from Triply Periodic Minimal Surface (TPMS) structures effectively mimic the geometric, mechanical, and fluid transport characteristics of human bones. These porous architectures facilitate fluid flow and augment bone cell adhesion and proliferation through their substantial surface area. In this study, the potential of network solid and sheet solid TPMS scaffolds with the same Schwarz Primitive architecture was compared for bone regeneration. Both types were modeled at 50%, 60%, 70%, and 80% porosity. A computational fluid dynamics (CFD) analysis was conducted to assess parameters such as surface area, pore size, permeability, wall shear stress, and flow rate. These parameters are known to exert a significant influence on the behavior of bone cells. The results demonstrated that network solids exhibited enhanced permeability and augmented pore sizes, thereby facilitating cell migration and nutrient delivery. Conversely, sheet solids exhibited elevated surface areas, thereby fostering cell adhesion and proliferation. Despite exhibiting equivalent porosity, the two structures manifested discernible disparities in geometry and flow performance. Network solid structures generally provided more favorable conditions for fluid flow and mechanical stimulation. Nevertheless, the selection of network or sheet architectures should be informed by specific clinical needs and tissue requirements. The findings demonstrate that architectural differences significantly affect scaffold performance, and understanding these effects can help optimize scaffold design for bone tissue engineering applications.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"676-686"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144576047","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An auxetic insole design with reverse graded-stiffness to relieve detrimental tissue stresses under bony prominence of calcaneus in diabetic foot. 一种具有反向分级刚度的增塑型鞋垫设计,以减轻糖尿病足跟骨突出处的有害组织应力。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-03 DOI: 10.1177/09544119251350412
Xingyu Zhang, Xiang Geng, Xin Ma, Wen-Ming Chen
{"title":"An auxetic insole design with reverse graded-stiffness to relieve detrimental tissue stresses under bony prominence of calcaneus in diabetic foot.","authors":"Xingyu Zhang, Xiang Geng, Xin Ma, Wen-Ming Chen","doi":"10.1177/09544119251350412","DOIUrl":"10.1177/09544119251350412","url":null,"abstract":"<p><p>To effectively mitigate detrimental tissue stresses of the diabetic foot for preventing ulceration, contemporary strategies frequently utilize pressure-relief insoles. In this study, we have developed an innovative enhanced pressure-relief insole that integrate auxetic structures with a reverse graded-stiffness property. We introduce a novel modification to the insole internal structure, exhibiting untraditional regional stiffness from the center to the periphery. We utilize a validated finite element (FE) heel model of a diabetic patient to evaluate the effectiveness of the insole, computing internal stress of the heel (peak stresses, total stress concentration exposure, pressure on the fat pad, and tensile stress on the skin) and insole deformation. In addition, we conduct in-vitro uniaxial compression and in-vivo biomechanical experiments to assess its effects in static and gait. The FE results showed a significant reduction in internal stress within high-risk ulcer areas of the heel, with peak internal stresses reduced to 232.9 kPa (without insole: 374.6 kPa), and notable changes in the deformation across the insole's coronal plane. Additionally, uniaxial tensile tests demonstrated optimal energy dissipation at 28.76%. During gait, the auxetic insole resulted in a 19.72% reduction in peak pressure and 15.37% reduction in peak pressures-time integral compared to the conventional insole. A novel insole with auxetic structure and reverse graded-stiffness appear to better relieve the internal loads, gait-related pressure as well as enhanced energy dissipation for the plantar soft tissue under bony prominence of calcaneus of human foot. This research also holds substantial promise for optimizing other pressure-relief orthotic devices.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"666-675"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144560876","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Novel methods to quantify gait rehabilitation following ankle-foot fractures. 量化踝足骨折后步态康复的新方法。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-07 DOI: 10.1177/09544119251348490
Imran Mahmood, Anam Raza, Tayyaba Sultana, Abbas A Dehghani-Sanij
{"title":"Novel methods to quantify gait rehabilitation following ankle-foot fractures.","authors":"Imran Mahmood, Anam Raza, Tayyaba Sultana, Abbas A Dehghani-Sanij","doi":"10.1177/09544119251348490","DOIUrl":"10.1177/09544119251348490","url":null,"abstract":"<p><p>Lower limb fragility fractures included a break in bone from the pelvis to the foot. Weight-bearing and walking stability stand as key performance indicators to quantify fracture restoration. Normally, progress in fracture rehabilitation is observed through clinical assessments and patients' responses, and modern research also presents instrumented gait analysis. There exists a gap to statistically compute the regaining in patients' weight-bearing ability and walking stability following fractures. This study introduces methods to advance the analysis of instrumented signals and evaluate walking stability in fracture-healing patients. The centre of pressure (CoP) signals were captured for four conditions: tibia/fibula/talus fracture near the ankle (AF), lower-leg shaft fracture (LF), calcaneus fractures (CF), and normal ankle (NA). The time derivative for CoP signals showed impulsive responses during the loading and unloading transitions which were then modelled and transformed to the frequency domain. The developed models were further analysed by applying Nyquist and Bode methods and margins of stability were calculated for the fractured and healthy subjects. Results showed a substantial decline (Kruskal-Wallis's test, <i>p</i> < 0.001) in the intralimb stability of all three fractures. Also, there was a strong interlimb dependency (<i>p</i> < 0.001) observed between fractured and intact limbs applying Spearman's correlation during double limb support periods. Overall, the calcaneus fracture (CF) exhibited minimum intralimb stability and increased interlimb dependency. These methods stand clinically important in monitoring patients' rehabilitation and in decision-making about alternative treatment plans.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"644-655"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144576058","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
FEM modeling of lateral collateral & medial collateral ligaments for use in total knee arthroplasty surgery simulation. 全膝关节置换术中外侧副韧带和内侧副韧带的有限元模拟。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-21 DOI: 10.1177/09544119251350787
Vida Shams Esfand Abadi, Soroush Sadeghnejad, Mostafa Rostami, Farzam Farahmand
{"title":"FEM modeling of lateral collateral & medial collateral ligaments for use in total knee arthroplasty surgery simulation.","authors":"Vida Shams Esfand Abadi, Soroush Sadeghnejad, Mostafa Rostami, Farzam Farahmand","doi":"10.1177/09544119251350787","DOIUrl":"10.1177/09544119251350787","url":null,"abstract":"<p><p>The objective of this study is to model the lateral collateral ligament (LCL) and medial collateral ligament (MCL) around the artificial knee joint in such a way that the virtual ligaments have the same behavior as the native ligaments around the artificial knee joint in reality. This study provides more accuracy in knee biomechanical simulation by introducing a nonlinear model for MCL and LCL ligaments and improved the modeling of ligaments by assigning nonlinear elastic behavior through achieving the force-displacement relationship in nonlinear form and assigned this relationship to the uniaxial connectors that represent the ligament bundles. The results showed that the virtual ligaments can only bear tensile loads and have the same behavior as the native ligaments that surround the artificial knee joint. In addition, the results obtained for tibiofemoral contact forces and ligament forces have been compared with the reference data and have shown significant agreement. This model serves as a biomechanical platform for simulating soft tissue balancing strategies in TKA. While the current study does not implement specific surgical techniques, the validated ligament representation enables future simulations involving clinical interventions such as ligament release, alignment adjustments, and gap balancing procedures and helps the surgeon to evaluate the result of treatment plan on the knee joint before the surgery.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"636-643"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144682958","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A finite element study of the effect of cross-link stabilisation in a lumbar spine tumour model. 腰椎肿瘤模型中交联稳定效应的有限元研究。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-07 DOI: 10.1177/09544119251348279
Juntong Lai, James Tomlinson, Lee Breakwell, Damien Lacroix
{"title":"A finite element study of the effect of cross-link stabilisation in a lumbar spine tumour model.","authors":"Juntong Lai, James Tomlinson, Lee Breakwell, Damien Lacroix","doi":"10.1177/09544119251348279","DOIUrl":"10.1177/09544119251348279","url":null,"abstract":"<p><p>Spinal metastases can increase the risks of vertebral fracture due to bony destruction and instability in the spine. There are concerns that cross-links may impair adjuvant treatments, such as radiotherapy and proton beam therapy. The aim of this study was to assess the biomechanical effects of cross-link stabilisation for a growing tumour in order to provide recommendations on the use and placement of the cross-link. A finite element (FE) model of a fixation device was developed. The device was inserted virtually into a FE model of the lumbar spine (L1-S1) between L2 and L4. Tumour deposit of either 1.3%, 10.1%, 38.3%, 71.5% and 92.1% of the vertebral body was simulated. A 1000 N compressive, a 10° lateral bending and a 7.5 Nm torsional load were simulated on the top of L1. Results indicate that the stabilisation is capable of reducing the stress of the L3 lumbar spine under torsion with a growing tumour. However, compressive loading is concentrated in the L3 anterior vertebra when the tumour volume was greater than 10.1% of the vertebra volume. The cross-link stabilisation reduced the stress of the posterior body within the stabilised segments (L2-L4), especially under torsion. The position of the cross-link does affect the ability of stabilisation to reduce concentrated stress of both vertebrae and screws, which indicates that the position of the cross-link should be considered in clinical surgery to refine the stress concentration, spinal stability and structural stiffness, without compromising adjuvant treatments.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"607-623"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12287565/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144584593","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Biomechanical evaluation of biodegradable PCL cog threads for prolapse rehabilitation. 生物可降解PCL螺纹脱垂康复的生物力学评价。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-07 DOI: 10.1177/09544119251343371
Fábio Pinheiro, Abílio Manuel Pinho de Jesus, Ana Colette Maurício, Nuno Alves, António Augusto Fernandes, Maria Elisabete Teixeira da Silva
{"title":"Biomechanical evaluation of biodegradable PCL cog threads for prolapse rehabilitation.","authors":"Fábio Pinheiro, Abílio Manuel Pinho de Jesus, Ana Colette Maurício, Nuno Alves, António Augusto Fernandes, Maria Elisabete Teixeira da Silva","doi":"10.1177/09544119251343371","DOIUrl":"10.1177/09544119251343371","url":null,"abstract":"<p><p>Pelvic organ prolapse (POP) is a prevalent pelvic floor dysfunction (PFD) that significantly impacts women's quality of life, driving the need for innovative and less invasive treatment options. Surgical intervention remains the primary treatment for POP; however, it is often associated with high invasiveness, substantial risks, and a notable rate of failure. In this study, we investigate the potential of biodegradable cog threads, commonly used in cosmetic facial lifting, as an alternative surgical solution for reinforcing vaginal wall defects. Specifically, we evaluate the performance of commercially available 360° 4D barb threads made of polycaprolactone (PCL) under simulated physiological conditions. The degradation and mechanical properties of the threads were analyzed after immersion in Phosphate Buffer Solution (PBS) and Potassium Hydrogen Phthalate (KHP) for periods of 90 and 180 days, with comparisons to a control group. Fourier-transform infrared (FTIR) spectroscopy revealed mild to moderate degradation of the threads over 180 days in both mediums. Tensile strength tests indicated a reduction in maximum load-bearing capacity, with declines of 13% to 19%, more pronounced in the PBS medium. Despite this, cyclic tests demonstrated that the threads retained sufficient mechanical integrity to endure 100 loading cycles across all conditions, suggesting their durability under repetitive stress. These preliminary in vitro findings highlight the potential of biodegradable cog threads as a promising material for developing a novel, minimally invasive technique for POP correction. The threads' ability to maintain mechanical strength despite degradation supports their viability for long-term pelvic floor reinforcement.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"687-696"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144584594","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Deep learning based time-dependent reliability analysis of an underactuated lower-limb robot exoskeleton for gait rehabilitation. 基于深度学习的欠驱动下肢机器人外骨骼步态康复可靠性分析。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-07 DOI: 10.1177/09544119251349362
Fahad Hussain, Tanishka Goyal, Shahid Hussain, Prashant Jamwal, Roland Goecke
{"title":"Deep learning based time-dependent reliability analysis of an underactuated lower-limb robot exoskeleton for gait rehabilitation.","authors":"Fahad Hussain, Tanishka Goyal, Shahid Hussain, Prashant Jamwal, Roland Goecke","doi":"10.1177/09544119251349362","DOIUrl":"10.1177/09544119251349362","url":null,"abstract":"<p><p>This study evaluates the reliability of an underactuated wearable lower-limb exoskeleton designed to assist with gait rehabilitation. Recognizing the complexity of system reliability, a deep learning framework augmented with Long short-term Memory (LSTM) was utilized for the time-dependent reliability analysis of dynamic systems. The research commenced with the development of a lower-limb gait robot, modeled on a Stephenson III six-bar linkage mechanism. Following the mechanical design, computer-aided design (CAD) tools were employed to conceptualize a lower-limb robotic exoskeleton for rehabilitation purposes. The design incorporated two metallic materials (aluminum and steel), and a composite material (carbon fiber) tested using SolidWorks<sup>®</sup>. The prototype achieved a lightweight design (~1.63 kg) for carbon fiber material. An LSTM-enhanced deep neural network algorithm was implemented to predict the time-dependent reliability of joint displacements and end-effector trajectories. Finally, conditional probability methods were applied to complete the time-dependent system reliability assessment. The designed mechanical system for gait rehabilitation demonstrated high reliability (<i>R</i> ≈ 0.87). Over 200 simulation runs, reliability trends showed consistent and robust predictions.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"656-665"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144576046","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Investigating the effects of geometrical parameters of an artificial cervical disc in vulnerable neck positions on the stress distribution in the spine using 3D finite element analysis. 采用三维有限元分析方法研究颈椎脆弱位置人工颈椎间盘几何参数对脊柱应力分布的影响。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-07 DOI: 10.1177/09544119251351175
Yalda Nasiri, Amir Khosravifard
{"title":"Investigating the effects of geometrical parameters of an artificial cervical disc in vulnerable neck positions on the stress distribution in the spine using 3D finite element analysis.","authors":"Yalda Nasiri, Amir Khosravifard","doi":"10.1177/09544119251351175","DOIUrl":"10.1177/09544119251351175","url":null,"abstract":"<p><p>One of the most common diseases of the spine is the degenerative intervertebral disc, which in extreme cases requires surgery. Replacing a damaged disc with an artificial disc (AD) is a common treatment method. Nowadays, due to the extensive use of smartphones and other similar devices, our cervical spine is often in a vulnerable position, such as a bent position, which results in more stress on the components of the spine, especially intervertebral discs. In this research, the effects of geometrical parameters of an AD on the biomechanics of the cervical spine are investigated in a bent neck position, using the finite element method. In this regard, computed tomography scans of the neck of a 29-year-old male in two states of straight and bent neck are used. Nine different AD geometries are generated by varying three geometric design variables, including the height, position of the centre of rotation and rotation radius of the AD. The results of stress distribution in the spine for the straight and bent neck positions are compared, and the maximum von Mises stress on the AD and healthy discs are assessed to choose an optimum geometry. The results show that proper selection of the geometrical parameters of the AD can lead to up to an 85% reduction in the AD's maximum von Mises stress for a bent neck position. The sensitivity analysis shows that the location of the rotation centre has the highest impact on the distribution of von Mises stress in the artificial disc.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"624-635"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144576056","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Multiphase fluid-solid interaction analysis of stent-vessel-blood based on type B aortic dissection. 基于B型主动脉夹层支架-血管血液的多相流固相互作用分析。
IF 1.7 4区 医学
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2025-07-01 Epub Date: 2025-07-07 DOI: 10.1177/09544119251344437
Shirun Zhong, Yang Ouyang, Geng'e Zhang, Shanshan Hu, Feixiang Xiong
{"title":"Multiphase fluid-solid interaction analysis of stent-vessel-blood based on type B aortic dissection.","authors":"Shirun Zhong, Yang Ouyang, Geng'e Zhang, Shanshan Hu, Feixiang Xiong","doi":"10.1177/09544119251344437","DOIUrl":"10.1177/09544119251344437","url":null,"abstract":"<p><p>Thoracic endovascular aortic repair (TEVAR) is an effective treatment method for Stanford type B aortic dissection (TB-AD). In the investigation of treatment methods of TEVAR, numerical simulation technologies play a pivotal role. However, current finite element simulations of AD often use overly simplified vascular models and fail to adequately consider the complex interactions between stents, vessels, and blood. In this study, a Boolean operation was adopted to establish 3D models of TB-AD based on patient-specific CT images. The 3D software was used to construct 5, 6, and 8-peak stent grafts. A finite element method was applied to simulate the compression and release processing of stent graft deployment. Finally, a fluid-solid interaction module was constructed for the multiphase fluid-solid interaction simulation. The results showed that after stent graft deployment, the cross-sectional area of the vessels in the aortic coarctation region increased by 60.0%-65.5%. The maximum blood flow velocity in the true lumen decreased from 1.585 m/s to 1.125-1.238 m/s. The maximum blood pressure increased from 1574 Pa (true lumen) and 1853 Pa (false lumen) to 2021-2165 Pa (true lumen). The distribution of wall equivalent stress was more uniform, and the maximum value decreased from 0.5475 MPa to 0.1667-0.1758 MPa. The maximum equivalent stress of the stent was 3.815-4.315 MPa. Comprehensive comparisons showed that the eight-peak stent graft exhibited lower equivalent stress and superior improvement in vascular morphology, blood flow, and vessel stress, providing an optimal stent graft option for the clinical treatment of TB-AD.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"593-606"},"PeriodicalIF":1.7,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144576057","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信