Fahad Hussain, Tanishka Goyal, Shahid Hussain, Prashant Jamwal, Roland Goecke
{"title":"基于深度学习的欠驱动下肢机器人外骨骼步态康复可靠性分析。","authors":"Fahad Hussain, Tanishka Goyal, Shahid Hussain, Prashant Jamwal, Roland Goecke","doi":"10.1177/09544119251349362","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluates the reliability of an underactuated wearable lower-limb exoskeleton designed to assist with gait rehabilitation. Recognizing the complexity of system reliability, a deep learning framework augmented with Long short-term Memory (LSTM) was utilized for the time-dependent reliability analysis of dynamic systems. The research commenced with the development of a lower-limb gait robot, modeled on a Stephenson III six-bar linkage mechanism. Following the mechanical design, computer-aided design (CAD) tools were employed to conceptualize a lower-limb robotic exoskeleton for rehabilitation purposes. The design incorporated two metallic materials (aluminum and steel), and a composite material (carbon fiber) tested using SolidWorks<sup>®</sup>. The prototype achieved a lightweight design (~1.63 kg) for carbon fiber material. An LSTM-enhanced deep neural network algorithm was implemented to predict the time-dependent reliability of joint displacements and end-effector trajectories. Finally, conditional probability methods were applied to complete the time-dependent system reliability assessment. The designed mechanical system for gait rehabilitation demonstrated high reliability (<i>R</i> ≈ 0.87). Over 200 simulation runs, reliability trends showed consistent and robust predictions.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"9544119251349362"},"PeriodicalIF":1.7000,"publicationDate":"2025-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Deep learning based time-dependent reliability analysis of an underactuated lower-limb robot exoskeleton for gait rehabilitation.\",\"authors\":\"Fahad Hussain, Tanishka Goyal, Shahid Hussain, Prashant Jamwal, Roland Goecke\",\"doi\":\"10.1177/09544119251349362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study evaluates the reliability of an underactuated wearable lower-limb exoskeleton designed to assist with gait rehabilitation. Recognizing the complexity of system reliability, a deep learning framework augmented with Long short-term Memory (LSTM) was utilized for the time-dependent reliability analysis of dynamic systems. The research commenced with the development of a lower-limb gait robot, modeled on a Stephenson III six-bar linkage mechanism. Following the mechanical design, computer-aided design (CAD) tools were employed to conceptualize a lower-limb robotic exoskeleton for rehabilitation purposes. The design incorporated two metallic materials (aluminum and steel), and a composite material (carbon fiber) tested using SolidWorks<sup>®</sup>. The prototype achieved a lightweight design (~1.63 kg) for carbon fiber material. An LSTM-enhanced deep neural network algorithm was implemented to predict the time-dependent reliability of joint displacements and end-effector trajectories. Finally, conditional probability methods were applied to complete the time-dependent system reliability assessment. The designed mechanical system for gait rehabilitation demonstrated high reliability (<i>R</i> ≈ 0.87). Over 200 simulation runs, reliability trends showed consistent and robust predictions.</p>\",\"PeriodicalId\":20666,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"volume\":\" \",\"pages\":\"9544119251349362\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-07-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/09544119251349362\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119251349362","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Deep learning based time-dependent reliability analysis of an underactuated lower-limb robot exoskeleton for gait rehabilitation.
This study evaluates the reliability of an underactuated wearable lower-limb exoskeleton designed to assist with gait rehabilitation. Recognizing the complexity of system reliability, a deep learning framework augmented with Long short-term Memory (LSTM) was utilized for the time-dependent reliability analysis of dynamic systems. The research commenced with the development of a lower-limb gait robot, modeled on a Stephenson III six-bar linkage mechanism. Following the mechanical design, computer-aided design (CAD) tools were employed to conceptualize a lower-limb robotic exoskeleton for rehabilitation purposes. The design incorporated two metallic materials (aluminum and steel), and a composite material (carbon fiber) tested using SolidWorks®. The prototype achieved a lightweight design (~1.63 kg) for carbon fiber material. An LSTM-enhanced deep neural network algorithm was implemented to predict the time-dependent reliability of joint displacements and end-effector trajectories. Finally, conditional probability methods were applied to complete the time-dependent system reliability assessment. The designed mechanical system for gait rehabilitation demonstrated high reliability (R ≈ 0.87). Over 200 simulation runs, reliability trends showed consistent and robust predictions.
期刊介绍:
The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.