A Gelman, E G Furman, N M Kalinina, S V Malinin, G B Furman, V S Sheludko, V L Sokolovsky
{"title":"Computer-Aided Detection of Respiratory Sounds in Bronchial Asthma Patients Based on Machine Learning Method.","authors":"A Gelman, E G Furman, N M Kalinina, S V Malinin, G B Furman, V S Sheludko, V L Sokolovsky","doi":"10.17691/stm2022.14.5.05","DOIUrl":"https://doi.org/10.17691/stm2022.14.5.05","url":null,"abstract":"<p><p><b>The aim of the study</b> is to develop a method for detection of pathological respiratory sound, caused by bronchial asthma, with the aid of machine learning techniques.</p><p><strong>Materials and methods: </strong>To build and train neural networks, we used the records of respiratory sounds of bronchial asthma patients at different stages of the disease (n=951) aged from several months to 47 years old and healthy volunteers (n=167). The sounds were recorded with calm breathing at four points: at the oral cavity, above the trachea, on the chest (second intercostal space on the right side), and at a point on the back.</p><p><strong>Results: </strong>The method developed for computer-aided detection of respiratory sounds allows to diagnose sounds typical for bronchial asthma in 89.4% of cases with 89.3% sensitivity and 86.0% specificity regardless of sex and age of the patients, stage of the disease, and the point of sound recording.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171063/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9675002","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
G V Zolotenkova, A I Rogachev, Y I Pigolkin, I S Edelev, V N Borshchevskaya, R Cameriere
{"title":"Age Classification in Forensic Medicine Using Machine Learning Techniques.","authors":"G V Zolotenkova, A I Rogachev, Y I Pigolkin, I S Edelev, V N Borshchevskaya, R Cameriere","doi":"10.17691/stm2022.14.1.02","DOIUrl":"https://doi.org/10.17691/stm2022.14.1.02","url":null,"abstract":"<p><p><b>The aim of the study</b> was to assess the capabilities of age determination (age group) at death using classification techniques by histomorphometric characteristics of osseous and cartilaginous tissue aging.</p><p><strong>Materials and methods: </strong>The study material was a database containing the findings of morphometric researches of osseous and cartilaginous tissue histologic specimens from 294 categorized male corpses aged 10-93 years. For data analysis and classification we used modern machine learning methods: k-NN, SVM, logistic regression, CatBoost, SGD, naive Bayes, random forest, nonlinear dimensionality reduction methods (t-SNE and uMAP), and recursive feature elimination for feature selection.</p><p><strong>Results: </strong>The used techniques (algorithms) provided effective representation of a complex data set (76 histomorphometric features), allowing to reveal the cluster structure inside the low dimensional feature space, thus fitting the classifier becomes even more reasonable. During feature selection, we estimated their importance for age group classification and studied the relationship between classification quality and the number of features inside the feature space. Data pre-processing made it possible to get rid of noise and keep most informative features, thereby accelerating a learning process and improving the classification quality. Data projection showed more well-defined cluster structure in the space of selected features. The accuracy of establishing certain groups was equal to 90%. It proves high efficiency of machine learning techniques used for forensic age diagnostics based on histomorphometric findings.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9376755/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40716815","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V V Zinchenko, K M Arzamasov, S F Chetverikov, A V Maltsev, V P Novik, E S Akhmad, D E Sharova, A E Andreychenko, A V Vladzymyrskyy, S P Morozov
{"title":"Methodology for Conducting Post-Marketing Surveillance of Software as a Medical Device Based on Artificial Intelligence Technologies.","authors":"V V Zinchenko, K M Arzamasov, S F Chetverikov, A V Maltsev, V P Novik, E S Akhmad, D E Sharova, A E Andreychenko, A V Vladzymyrskyy, S P Morozov","doi":"10.17691/stm2022.14.5.02","DOIUrl":"https://doi.org/10.17691/stm2022.14.5.02","url":null,"abstract":"<p><p><b>The aim of the study</b> was to develop a methodology for conducting post-registration clinical monitoring of software as a medical device based on artificial intelligence technologies (SaMD-AI).</p><p><strong>Materials and methods: </strong>The methodology of post-registration clinical monitoring is based on the requirements of regulatory legal acts issued by the Board of the Eurasian Economic Commission. To comply with these requirements, the monitoring involves submission of the review of adverse events reports, the review of developers' routine reports on the safety and efficiency of SaMD-AI, and the assessment of the system for collecting and analyzing developers' post-registration data on the safety and efficiency of medical devices. The methodology was developed with regard to the recommendations of the International Medical Device Regulators Forum and the documents issued by the Food and Drug Administration (USA). Field-testing of this methodology was carried out using SaMD-AI designed for diagnostic imaging.</p><p><strong>Results: </strong>The post-registration monitoring of SaMD-AI consists of three key stages: collecting user feedback, technical monitoring and clinical validation. Technical monitoring involves routine evaluation of SaMD-AI output data quality to detect and remove flaws in a timely manner, and to secure the product stability. Major outcomes include an ordered list of technical flaws in SaMD-AI and their classification using evidence from diagnostic imaging studies. The application of this methodology resulted in a gradual reduction in the number of studies with flaws due to timely improvements in artificial intelligence algorithms: the number of flaws decreased to 5% in various aspects during subsequent testing. Clinical validation confirmed that SaMD-AI is capable of producing clinically meaningful outputs related to its intended use within the functionality determined by the developer. The testing procedure and the baseline testing framework were established during the field testing.</p><p><strong>Conclusion: </strong>The developed methodology will ensure the safety and efficiency of SaMD-AI taking into account its specifics as intangible medical devices. The methodology presented in this paper can be used by SaMD-AI developers to plan and carry out the post-registration clinical monitoring.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171062/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9681409","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Identification of Neurophysiological Markers of Verbal Information Processing Using Cognitive Evoked Potentials for Studying Schizophrenia Spectrum Disorders.","authors":"N S Nuzhina, P A Prodius, I V Mukhina","doi":"10.17691/stm2022.14.6.06","DOIUrl":"https://doi.org/10.17691/stm2022.14.6.06","url":null,"abstract":"<p><p><b>The aim of the study</b> is to identify neurophysiological markers of information processing sensitive to verbal thinking impairment in persons with schizotypal personality organization using the method of cognitive evoked potentials.</p><p><strong>Materials and methods: </strong>Cognitive evoked potentials were studied in 40 students of higher school with high and low (control) scores obtained on the Schizotypal Personality Questionnaire (SPQ) in response to the presentation of visual verbal information in the form of agreed word-combinations. In the first series of presentations, it was necessary to refer the attribute to one of the categories and to read the noun silently (non-target condition). In the second series, the attribute should be read silently, and then the following noun has to be categorized (target condition). There has been performed a cluster analysis of the evoked potential curves obtained in response to the noun presentation in the target and non-target conditions in the groups of participants with high and low scores gained on SPQ.</p><p><strong>Results: </strong>Processing of the verbal stimulus under passive reading conditions and under the conditions of word categorization within the frameworks of a simple context has shown that in the group with low scores on the schizotypal questionnaire, lateralization of the N150 component to the left side was observed in contrast to the group with high scores. In this group, increase of the N400 component amplitude was found in response to the words presented for their passive reading in comparison with the categorization condition. On the contrary, in the group with high schizotypy scores, the N400 component appeared to be insensitive to the type of the task, i.e. neurophysiological differences were not expressed between reading and performing stimuli categorization task. These persons were found to have the decreased amplitude of the late positive component as compared to the control group under the condition of passive reading of the words. Increase of the late negative wave amplitude was registered in response to the target words subjected to categorization in comparison with reading in both groups of participants. Insufficiency of language lateralization and deficit connected with the language networks being activated automatically at the initial stage of word recognition are observed in the examined persons with schizotypy. Additionally, processing of the information in these persons at the stage of lexical-semantic processes is weakly modulated by the task imposing different requirements on the level of mental activity control. Some reduction of mnestic process activation is also possible, which is manifested during passive reading of the words, but not in the conditions of their categorization.</p><p><strong>Conclusion: </strong>The research conducted may serve as a starting point for a more detailed and long-term study of the fundamental mechanisms of impairment in ","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171056/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9687173","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A A Lebedeva, A I Kavun, E M Veselovsky, V A Mileyko, M V Ivanov
{"title":"CRAC (Clinical Relevance of Alterations in Cancer): a Knowledge Base for the Selection of Molecularly Matched Therapy for Solid Tumors.","authors":"A A Lebedeva, A I Kavun, E M Veselovsky, V A Mileyko, M V Ivanov","doi":"10.17691/stm2022.14.6.02","DOIUrl":"https://doi.org/10.17691/stm2022.14.6.02","url":null,"abstract":"<p><p>Multigene testing using NGS (next-generation sequencing) provides a large amount of information and can detect multiple molecular alterations. Subsequent clinical interpretation is a time-consuming process necessary to select a treatment strategy. Existing databases often contain inconsistent information and are not regularly updated. The use of ESCAT levels of evidence requires a deep understanding of the nature of alterations and does not answer the question of which therapy option to select when multiple biomarkers with the same level of evidence are detected. To address these issues, we created the Clinical Relevance of Alterations in Cancer (CRAC) database on the relevance of detected alterations in specific genes, which are often analyzed as part of NGS panels. The team of oncologists and biologists assigned a CRAC score from 1 to 10 to each biomarker (a type of genomic alteration characteristic of specific genes) for 15 malignancies; an average score was entered into the database. CRAC scores are a numerical reflection of the following factors: therapy availability and the prospects of drug treatment with experimental drugs for patients with a particular type of tumor. A total of 134 genes and 15 of the most common tumor types have been selected for CRAC. The biomarker-nosology associations with CRAC scores in the range of 1-3 are the most frequent (n=2719 out of 3495; 77.8%), the least frequent ones (n=52 out of 3495; 1.5%) are with the highest CRAC scores 9 and 10. To estimate the practical effectiveness of the CRAC database, 208 reports on comprehensive molecular profiling were retrospectively analyzed; the applicability of CRAC was compared with the ESCAT level of evidence system. The highest CRAC scores corresponded to the ESCAT maximum levels of evidence: the range of scores 8-10 corresponded to evidence levels I and II. No biomarker within the same level of evidence was represented by the same CRAC score; the largest range of CRAC scores was observed for biomarkers of levels evidence IIIA and IV - from 2 to 10 and from 1 to 9, respectively. The use of CRAC scores allowed to identify additional 95 alterations with CRAC scores of 1-5 in the studied patients. The developed database is available at: https://crac.oncoatlas.ru/.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171055/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9687175","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
E N Filatova, A S Chaikina, N F Brusnigina, M A Makhova, O V Utkin
{"title":"An Algorithm for the Selection of Probes for Specific Detection of Human Disease Pathogens Using the DNA Microarray Technology.","authors":"E N Filatova, A S Chaikina, N F Brusnigina, M A Makhova, O V Utkin","doi":"10.17691/stm2022.14.1.01","DOIUrl":"https://doi.org/10.17691/stm2022.14.1.01","url":null,"abstract":"<p><p><b>The aim of the study</b> was to develop an algorithm for the selection of discriminating probes to identify a wide range of causative agents of human infectious diseases.</p><p><strong>Materials and methods: </strong>The algorithm for selecting the probes was implemented in the form of the disprose (DIScrimination PRObe SElection) computer program written in the R language. Additionally, third-party software was used: the BLAST+ and ViennaRNA Package programs. The developed algorithm was tested by selecting specific probes for detecting <i>Chlamydophila (Chlamydia) pneumoniae</i> - an atypical bacterial pathogen causing community-acquired pneumonia (CAP). Nucleotide sequences for analysis were downloaded from the NCBI databank.</p><p><strong>Results: </strong>An algorithm for the selection of specific probes capable of detecting human infectious pathogens has been developed. The algorithm is implemented in the form of the disprose modular program, which allows for performing all stages of the probe selection process: loading the nucleotide sequences and their metadata from available databanks, creating local databases, forming a pool of probes, calculating their physicochemical parameters, aligning the probes and sequences contained in local databases, processing and evaluating the alignment results. The algorithm was successfully tested and its performance was confirmed by selecting a set of probes for the specific detection of <i>Chlamydophila pneumoniae</i>. The specificity of the selected probes calculated <i>in silico</i> indicated a low risk of their nonspecific binding and a high potential of using them as molecular genetic diagnostic tools (DNA microarrays, PCR).</p><p><strong>Conclusion: </strong>An algorithm for the selection of specific probes detecting a wide range of human pathogens in clinical biomaterial has been developed and implemented in the form of the disprose modular program. The probes selected using this program can serve as the functional basis of DNA-oriented microarrays able to identify causative agents of polyetiological diseases, such as CAP. Due to the flexibility and openness of the program, the scope of its application can be expanded.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9376759/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40716813","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sample Size Calculation for Clinical Trials of Medical Decision Support Systems with Binary Outcome.","authors":"O Yu Rebrova, A V Gusev","doi":"10.17691/stm2022.14.3.01","DOIUrl":"https://doi.org/10.17691/stm2022.14.3.01","url":null,"abstract":"<p><p>Currently, software products for use in medicine are actively developed. Among them, the dominant share belongs to clinical decision support systems (CDSS), which can be intelligent (based on mathematical models obtained by machine learning methods or other artificial intelligence technologies) or non-intelligent. For the state registration of CDSSs as software medical products, clinical trials are required, and the protocol of trial is developed jointly by the developer and an authorized medical organization. One of the mandatory components of the protocol is the calculation of the sample size. This article discusses the calculation of the sample size for the most common case, the binary outcome in diagnostic/screening and predictive systems. For diagnostic/screening models, cases of a non-comparative study, comparative study with testing of the superiority hypothesis, comparative study with testing of a hypothesis of non-inferiority in cross-sectional studies are considered. For predictive models, cases of randomized controlled trials of the complex intervention \"prediction + prediction-dependent patient management\" with testing of the hypothesis of superiority and non-inferiority are considered. It is emphasized that representativeness of the sample and other design components are no less important in clinical trials than sample size. They are even more important since systematic biases in clinical trials are primary, and even the most sophisticated statistical analysis cannot compensate for design defects. The reduction of clinical trials to external validation of models (i.e. evaluation of accuracy metrics on external data) seems completely unreasonable. It is recommended to perform clinical trials with the design adequate to the tasks, so that further clinical and economic analysis and comprehensive assessment of medical technologies are possible. The sample size calculation methods described in the article can potentially be applied to a wider range of medical devices.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090914/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9672109","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D V Pavlov, S B Korolev, A Yu Kopylov, A A Zykin, R O Gorbatov, T V Illarionova, V V Gorin, R V Alyev
{"title":"Use of Additive Technologies in Surgical Treatment of Chronic Posterior Dislocations of the Shoulder.","authors":"D V Pavlov, S B Korolev, A Yu Kopylov, A A Zykin, R O Gorbatov, T V Illarionova, V V Gorin, R V Alyev","doi":"10.17691/stm2022.14.3.06","DOIUrl":"https://doi.org/10.17691/stm2022.14.3.06","url":null,"abstract":"The aim of the study was to evaluate the efficiency of additive technologies in surgical treatment of patients with osteochondral defects of the humeral head articular surface against the background of chronic posterior dislocation of the shoulder by means of comparing clinical and radiological results with the McLaughlin procedure. Materials and Methods A prospective randomized comparative group clinical study was conducted, which included 20 patients who in 2019–2021 underwent surgical treatment of chronic posterior dislocation of the shoulder in the Traumatological and Orthopedic Department of the Institute of Traumatology and Orthopedics of the Privolzhsky Research Medical University (Nizhny Novgorod, Russia). Depending on the type of surgery, all patients were divided into 2 groups: group 1 (n=10) was subject to McLaughlin procedure, whereas group 2 (n=10) — to reconstruction of the humeral head using a customized implant based on additive technologies (3D printing). To assess postoperative results, 6 months after the surgery all patients underwent the following procedures: X-ray imaging of the shoulder joint in two projections, CT scanning, and angulometry as well as provided their responses in line with the following questionnaires: Visual Analog Scale (VAS), Disabilities of the Arm, Shoulder and Hand (DASH), American Shoulder and Elbow Surgeons Shoulder Score (ASES), Constant Shoulder Score (CSS), Shoulder Rating Questionnaire (SRQ), and the Hospital for Special Surgery Shoulder Surgery Expectations Survey (Survey of patient, SP). Results Both the McLaughlin procedure and the reconstruction of the humeral head using a customized implant made using additive 3D printing technologies increased the range of motion in the shoulder joint, mitigated the pain syndrome and improved the patients’ quality of life. During the postoperative period, there were no infectious complications in both groups. The total bed-day in group 1 was 7 [5; 9] days; in group 2, it was 8 [6; 9] days. There was no recurrence of dislocation or progression of osteoarthritis of the shoulder joint in patients in both groups during 6 months after the surgery. The ASES, SP, SRQ, CSS, DASH, and VAS questionnaires assessment for both groups showed a statistically significant improvement for all indicators in the postoperative period. There were no statistically significant differences found between the groups as to the results of angulometry and answering the questionnaires. Conclusion Customized implants made using additive technologies can shorten the surgery duration by 1.3 times, whereas the volume of intraoperative blood loss — by at least 1.5 times compared to the McLaughlin procedure.","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090916/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9686901","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Ion-Selective Electrodes for Measuring Potassium in Erythrocytes: a Model for Clinical Interpretation of the Results (a Pilot Study).","authors":"А А Astakhov, V V Kazartsev, K V Kuchkin, J Barg","doi":"10.17691/stm2022.14.3.05","DOIUrl":"https://doi.org/10.17691/stm2022.14.3.05","url":null,"abstract":"<p><p><b>The aim of the investigation</b> is to study the concentration of potassium in erythrocytes using the proposed method, potassium interconnection with other electrolyte and acid-base parameters of blood plasma, and to create the basis for clinical interpretation of the results.</p><p><strong>Materials and methods: </strong>Potassium content in erythrocytes was measured using a blood gas analyzer with ion-selective electrodes in parallel with the laboratory procedure. Patients from intensive care units were randomly selected for the study.</p><p><strong>Results: </strong>No correlations of potassium with other plasma parameters have been found, however its buffer dependence on chlorine in plasma has been established. Minimal value of potassium concentration in erythrocytes (for 356 measurements) was 68.2 mmol/L, maximal - 210.2 mmol/L.Following the logic of the acid-base status, a nomogram for clinical interpretation of intracellular potassium homeostasis has been developed. The low values are mainly connected with the deficit of potassium which is impossible to determine in blood plasma (e.g. in severe metabolic alkalosis or diuretic therapy). The elevated concentration of potassium in erythrocytes is caused by eryptosis: released potassium is absorbed by normal erythrocytes (protection from hyperkalaemia). So, the increased concentration of potassium indicates directly the presence of eryptosis triggers, i.e. inflammatory mediators, oxidative stress, and others, for example in sepsis. The results of the study have shown that measurement of potassium concentration in erythrocytes with the help of ion-selective electrodes is an effective method of monitoring its intracellular homeostasis. Potassium in erythrocytes is an independent biological marker which can provide clinically relevant information.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090918/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9686902","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
А А Shadanov, Т P Timchenko, S V Vladimirov, P E Lushchyk, А V Zablotsky, S О Kiselyov, I Yu Zhuravleva, D А Sirota, А M Chernyavskiy
{"title":"The Influence of Weaving Technologies on the Integral Characteristics of Synthetic Vascular Prostheses.","authors":"А А Shadanov, Т P Timchenko, S V Vladimirov, P E Lushchyk, А V Zablotsky, S О Kiselyov, I Yu Zhuravleva, D А Sirota, А M Chernyavskiy","doi":"10.17691/stm2022.14.6.01","DOIUrl":"https://doi.org/10.17691/stm2022.14.6.01","url":null,"abstract":"The aim of the study is to determine physical and structural properties of woven synthetic prostheses depending on the type of the weave. Materials and Methods Ten vascular prostheses manufactured at the Science and Technology Park of the BNTU “Polytechnic” (Minsk, Republic of Belarus) have been analyzed. The prostheses differed in the type of weaving, duration and temperature of thermal fixation during crimping. Three samples had a single-layer structure and 7 samples had a double-layer structure. Tests for water permeability, resistance to radial bending, and porosity of the prostheses have been performed. Results The single-layer woven prostheses have demonstrated a low level of water permeability: the best result was shown by sample No.1: 80 [77.1; 80.5] ml/min/cm2. A strong direct correlation was revealed for these prostheses: the larger the pore diameter, the greater permeability (r=0.778; p=0.05). The single-layer woven prostheses appeared to be most resistant to radial bending, samples No.1 and 3 had no deformations at the minimum radius of the cylinder (r<4 mm), sample No.2 showed deformation on the cylinder with r=5 mm. For the single-layer prostheses, a strong negative correlation was noted (r=‒0.97; p=0.04) between the density of the warp threads and the kinking radius. All double-layer prostheses have demonstrated higher water permeability and weak resistance to deformation during radial bending. Samples No.4 and 8 were found to have minimum and maximum water permeability of 276.5 [258.3; 288.4] and 538.8 [533.3; 564.3] ml/min/cm2, respectively. The minimum kinking radius (7 mm) was shown by samples No.9 and 10. The worst results were demonstrated by sample No.6, which was deformed with minimal bending. Conclusion Samples with ordinary plain weave have a low level of water permeability and high resistance to radial deformation, which makes them look most promising for the application in vascular surgery.","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":null,"pages":null},"PeriodicalIF":0.6,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171052/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9687179","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}