Magnetic Resonance in Medical Sciences最新文献

筛选
英文 中文
Recent Advances and Future Directions in Brain MR Imaging Studies in Schizophrenia: Toward Elucidating Brain Pathology and Developing Clinical Tools. 精神分裂症脑磁共振成像研究的最新进展和未来方向:朝着阐明脑病理和开发临床工具。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-10-01 Epub Date: 2021-08-19 DOI: 10.2463/mrms.rev.2021-0050
Shinsuke Koike, Akiko Uematsu, Daiki Sasabayashi, Norihide Maikusa, Tsutomu Takahashi, Kazutaka Ohi, Shinichiro Nakajima, Yoshihiro Noda, Yoji Hirano
{"title":"Recent Advances and Future Directions in Brain MR Imaging Studies in Schizophrenia: Toward Elucidating Brain Pathology and Developing Clinical Tools.","authors":"Shinsuke Koike,&nbsp;Akiko Uematsu,&nbsp;Daiki Sasabayashi,&nbsp;Norihide Maikusa,&nbsp;Tsutomu Takahashi,&nbsp;Kazutaka Ohi,&nbsp;Shinichiro Nakajima,&nbsp;Yoshihiro Noda,&nbsp;Yoji Hirano","doi":"10.2463/mrms.rev.2021-0050","DOIUrl":"https://doi.org/10.2463/mrms.rev.2021-0050","url":null,"abstract":"<p><p>Schizophrenia is a common severe psychiatric disorder that affects approximately 1% of general population through the life course. Historically, in Kraepelin's time, schizophrenia was a disease unit conceptualized as dementia praecox; however, since then, the disease concept has changed. Recent MRI studies had shown that the neuropathology of the brain in this disorder was characterized by mild progression before and after the onset of the disease, and that the brain alterations were relatively smaller than assumed. Although genetic factors contribute to the brain alterations in schizophrenia, which are thought to be trait differences, other changes include factors that are common in psychiatric diseases. Furthermore, it has been shown that the brain differences specific to schizophrenia were relatively small compared to other changes, such as those caused by brain development, aging, and gender. In addition, compared to the disease and participant factors, machine and imaging protocol differences could affect MRI signals, which should be addressed in multi-site studies. Recent advances in MRI modalities, such as multi-shell diffusion-weighted imaging, magnetic resonance spectroscopy, and multimodal brain imaging analysis, may be candidates to sharpen the characterization of schizophrenia-specific factors and provide new insights. The Brain/MINDS Beyond Human Brain MRI (BMB-HBM) project has been launched considering the differences and noises irrespective of the disease pathologies and includes the future perspectives of MRI studies for various psychiatric and neurological disorders. The sites use restricted MRI machines and harmonized multi-modal protocols, standardized image preprocessing, and traveling subject harmonization. Data sharing to the public will be planned in FY 2024. In the future, we believe that combining a high-quality human MRI dataset with genetic data, randomized controlled trials, and MRI for non-human primates and animal models will enable us to understand schizophrenia, elucidate its neural bases and therapeutic targets, and provide tools for clinical application at bedside.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/91/94/mrms-21-539.PMC9618928.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39336021","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Diagnostic Value of DCE-MRI for Differentiating Malignant Adnexal Masses Compared with Contrast-enhanced-T1WI. DCE-MRI与t1wi鉴别附件恶性肿块的诊断价值。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-10-01 Epub Date: 2021-09-03 DOI: 10.2463/mrms.mp.2021-0003
Satoshi Otani, Aki Kido, Yuki Himoto, Akihiko Sakata, Tomoaki Otani, Ryo Kuwahara, Yusaku Moribata, Naoko Nishio, Ryo Yajima, Kyoko Nakao, Yasuhisa Kurata, Sachiko Minamiguchi, Masaki Mandai, Yuji Nakamoto
{"title":"Diagnostic Value of DCE-MRI for Differentiating Malignant Adnexal Masses Compared with Contrast-enhanced-T1WI.","authors":"Satoshi Otani,&nbsp;Aki Kido,&nbsp;Yuki Himoto,&nbsp;Akihiko Sakata,&nbsp;Tomoaki Otani,&nbsp;Ryo Kuwahara,&nbsp;Yusaku Moribata,&nbsp;Naoko Nishio,&nbsp;Ryo Yajima,&nbsp;Kyoko Nakao,&nbsp;Yasuhisa Kurata,&nbsp;Sachiko Minamiguchi,&nbsp;Masaki Mandai,&nbsp;Yuji Nakamoto","doi":"10.2463/mrms.mp.2021-0003","DOIUrl":"https://doi.org/10.2463/mrms.mp.2021-0003","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the diagnostic performance of dynamic contrast-enhanced-MR (DCE-MR) and delayed contrast-enhanced (CE)-MRI added to unenhanced MRI, including diffusion weighted image (DWI) for differentiating malignant adnexal tumors, conducting a retrospective blinded image interpretation study.</p><p><strong>Methods: </strong>Data of 80 patients suspected of having adnexal tumors by ultrasonography between April 2008 and August 2018 were used for the study. All patients had undergone preoperative MRI and surgical resection at our institution. Four radiologists (two specialized in gynecological radiology and two non-specialized) were enrolled for blinded review of the MR images. A 3-point scale was used: 0 = benign, 1 = indeterminate, and 2 = malignant. Three imaging sets were reviewed: Set A, unenhanced MRI including DWI; Set B, Set A and delayed CE-T1WI; and Set C, Set A and DCE-MRI. Imaging criteria for benign and malignant tumors were given in earlier reports. The diagnostic performance of the three imaging sets of the four readers was calculated. Their areas under the curve (AUCs) were compared using the DeLong method.</p><p><strong>Results: </strong>Accuracies of Set B were 81%-88%. Those of Set C were 81%-85%. The AUCs of Set B were 0.83 and 0.89. Those of Set C were 0.81-0.86. For two readers, Set A showed lower accuracy and AUC than Set B/Set C (less than 0.80), although those were equivalent in other readers. No significant difference in AUCs was found among the three sequence sets. Intrareader agreement was moderate to almost perfect in Sets A and B, and substantial to almost perfect in Set C.</p><p><strong>Conclusion: </strong>DCE-MR showed no superiority for differentiating malignant adnexal tumors from benign tumors compared to delayed CE-T1WI with conventional MR and DWI.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a1/8d/mrms-21-599.PMC9618924.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39385356","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Bloch Simulation of a Three-point Dixon Experiment Using a Four-dimensional Numerical Phantom. 利用四维数值幻象进行三点Dixon实验的Bloch模拟。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-10-01 Epub Date: 2021-07-30 DOI: 10.2463/mrms.tn.2021-0054
Ryoichi Kose, Katsumi Kose, Yasuhiko Terada
{"title":"Bloch Simulation of a Three-point Dixon Experiment Using a Four-dimensional Numerical Phantom.","authors":"Ryoichi Kose,&nbsp;Katsumi Kose,&nbsp;Yasuhiko Terada","doi":"10.2463/mrms.tn.2021-0054","DOIUrl":"https://doi.org/10.2463/mrms.tn.2021-0054","url":null,"abstract":"<p><p>A 4D numerical phantom, which is defined in the 3D spatial axes and the resonance frequency axis, is indispensable for Bloch simulations of biological tissues with complex distribution of materials. In this study, a 4D numerical phantom was created using MR image datasets of a biological sample containing water and fat, and the Bloch simulations were performed using the 4D numerical phantom. As a result, 3D images of the sample containing water and fat were successfully reproduced, which demonstrated the usefulness of the concept of the 4D numerical phantom.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/4e/71/mrms-21-649.PMC9618923.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39264013","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Quantitative T2 Mapping to Discriminate Mucinous from Nonmucinous Adenocarcinoma in Rectal Cancer: Comparison with Diffusion-weighted Imaging. 定量T2定位鉴别直肠粘液腺癌与非粘液腺癌:与弥散加权成像的比较。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-10-01 Epub Date: 2021-08-21 DOI: 10.2463/mrms.mp.2021-0067
Junqin Zhang, Yuxi Ge, Heng Zhang, Zi Wang, Weiqiang Dou, Shudong Hu
{"title":"Quantitative T2 Mapping to Discriminate Mucinous from Nonmucinous Adenocarcinoma in Rectal Cancer: Comparison with Diffusion-weighted Imaging.","authors":"Junqin Zhang,&nbsp;Yuxi Ge,&nbsp;Heng Zhang,&nbsp;Zi Wang,&nbsp;Weiqiang Dou,&nbsp;Shudong Hu","doi":"10.2463/mrms.mp.2021-0067","DOIUrl":"https://doi.org/10.2463/mrms.mp.2021-0067","url":null,"abstract":"<p><strong>Purpose: </strong>Mucinous adenocarcinoma (MA) is associated with worse clinicopathological characteristics and a poorer prognosis than non-MA. Moreover, MA is related to worse tumor regression grade and tumor downstaging than non-MA. This study investigated whether lesions in MA and non-MA can be quantitatively assessed by T2 mapping technique and compared with the diffusion-weighted imaging (DWI).</p><p><strong>Methods: </strong>High-resolution MRI, DWI, and T2 mapping were performed on 81 patients diagnosed with rectal cancer via biopsy. Afterward, T2 and apparent diffusion coefficient (ADC) values were manually measured by a senior and a junior radiologist independently. By examining surgical specimens, the patients with MA and non-MA were identified. Inter-observer reproducibility was tested, and T2 and ADC values were compared using Mann-Whitney U test. Finally, receiver operating characteristic (ROC) curves were drawn to determine the cut-off value.</p><p><strong>Results: </strong>Of the 81 patients, 11 patients with MA were confirmed by pathology. The inter-observer reproducibility of T2 and ADC values showed an excellent intraclass correlation coefficient (ICC) of 0.993 and 0.913, respectively. MA had higher T2 (87.9 ± 5.11 ms) (P = 0.000) and ADC (2.03 × 10<sup>-3</sup> mm<sup>2</sup>/s) (P = 0.000) values than non-MA (66.6 ± 6.86 ms and 1.17 × 10<sup>-3</sup> mm<sup>2</sup>/s, respectively). The area under the ROC curves (AUC) of the T2 and ADC values were 0.999 (95% confidence interval [CI]: 0.953-1) and 0.979 (95% CI: 0.920-0.998), respectively. When the cutoff value in T2 mapping was 80 ms, the Youden index was the largest, sensitivity was 100%, and specificity was 97%.</p><p><strong>Conclusion: </strong>As a stable quantitative sequence, T2 mapping of MRI is useful in differentiating MA from non-MA. Compared to ADC values, T2 values are also diagnostically effective and non-inferior to ADC values.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/fb/89/mrms-21-593.PMC9618932.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39347031","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Performance of a Flexible 12-Channel Head Coil in Comparison to Commercial 16- And 24-Channel Rigid Head Coils. 柔性12通道头线圈与商用16通道和24通道刚性头线圈的性能比较。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-10-01 Epub Date: 2021-09-17 DOI: 10.2463/mrms.mp.2021-0084
YingJie Kang, YiLei Chen, JieMing Fang, YanWen Huang, Hui Wang, ZhiGang Gong, SongHua Zhan, WenLi Tan
{"title":"Performance of a Flexible 12-Channel Head Coil in Comparison to Commercial 16- And 24-Channel Rigid Head Coils.","authors":"YingJie Kang,&nbsp;YiLei Chen,&nbsp;JieMing Fang,&nbsp;YanWen Huang,&nbsp;Hui Wang,&nbsp;ZhiGang Gong,&nbsp;SongHua Zhan,&nbsp;WenLi Tan","doi":"10.2463/mrms.mp.2021-0084","DOIUrl":"https://doi.org/10.2463/mrms.mp.2021-0084","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the performance of a 12-channel flexible head coil (HFC12) with commercial 16-channel (HRC16) and 24-channel (HRC24) rigid coils.</p><p><strong>Methods: </strong>The phantom study was performed on a 1.5 T MR scanner with HFC12, HRC16, and HRC24. The SNR and noise correlation matrix of T1WI, T2WI, and diffusion weighted imaging (DWI) were measured. The SNR profiles were created according to the SNR. In addition, 1/g-factors were calculated in different acceleration directions. In the in vivo study, T1WI, T2WI, and DWI were performed in one healthy volunteer with three different coils. The SNR and noise correlation matrix were measured.</p><p><strong>Results: </strong>In the phantom study and in vivo study, the SNR of HFC12 in the transverse, sagittal, and coronal planes was the highest, followed by HRC24, and that of HRC16 was the lowest. The SNR profiles showed that the SNR at the edge of HFC12 was the highest. The mean value of the noise correlation matrix of HFC12 was the highest. The 1/g-factor results showed that HFC12 obtained the best acceleration ability in the head-foot acceleration direction when the reduction factor was set to two. The SNR of HFC12 in most cortices was significantly higher than that of HRC16 and HRC24, except in the occipital cortex. The SNR of HRC24 in the occipital cortex was higher than that of HFC12.</p><p><strong>Conclusion: </strong>The SNR of HFC12 in T1WI, T2WI, and DWI was better than that of the HRC24 and HFC16. The SNR of HFC12 in the cortex was significantly higher than that of the commercial rigid head coil, except in the occipital cortex.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ab/06/mrms-21-623.PMC9618927.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39433987","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Susceptibility-weighted Imaging for Renal Iron Overload Assessment: A Pilot Study. 敏感性加权成像对肾铁超载的评估:一项初步研究。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-07-01 Epub Date: 2021-02-27 DOI: 10.2463/mrms.mp.2020-0154
Jun Sun, Yuanyuan Sha, Weiwei Geng, Jie Chen, Wei Xing
{"title":"Susceptibility-weighted Imaging for Renal Iron Overload Assessment: A Pilot Study.","authors":"Jun Sun,&nbsp;Yuanyuan Sha,&nbsp;Weiwei Geng,&nbsp;Jie Chen,&nbsp;Wei Xing","doi":"10.2463/mrms.mp.2020-0154","DOIUrl":"https://doi.org/10.2463/mrms.mp.2020-0154","url":null,"abstract":"<p><strong>Purpose: </strong>To explore the feasibility of susceptibility-weighted imaging (SWI) for evaluating renal iron overload.</p><p><strong>Methods: </strong>Twenty-eight rabbits were randomly assigned into control (n = 14) and iron (n = 14) group. In the 0th week, the study group was injected with iron dextran. Both groups underwent SWI examination at the 0th, 8th, and 12th week. The signal intensity (SI) of cortex and medulla was assessed. Angle radian value (ARV) calculated with phase image was taken as the quantitative value for cortical and medullary iron deposition. After the 12th week, the left kidneys of rabbits were removed for pathology. The difference in the ARV among three groups was analyzed using Kruskal-Wallis test. The difference of the iron content between two groups was analyzed through independent sample t-test.</p><p><strong>Results: </strong>In the iron group: at the 12th week, eight rabbits were found to have decreased SI of only cortex, and the other six rabbits had decreased SI of cortex and medulla by the same degree; the ARV of cortex at the 8th and 12th week was significantly higher than that of the 0th week (P < 0.05); the ARV of the six rabbits' medulla at the 12th week was significantly higher than that of the 0th week, 8th week, and the other eight rabbits at the 12th week (P < 0.05); at the 12th week, eight rabbits (iron group) were found to have many irons only deposit in the cortex, and the others were found to have many irons deposit in both cortex and medulla; the iron content of cortex and six rabbits' medulla in the iron group was significantly higher than that of the control (P < 0.05).</p><p><strong>Conclusion: </strong>The ARV of SWI can be used to quantitatively assess the excess iron deposition in the kidneys. Excessive iron deposition mainly occurs in the cortex or medulla and causes their SWI SI to decrease.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/e0/d5/mrms-21-415.PMC9316138.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25419954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Assessing the ADC of Bone-marrow on Whole-body MR Images in Relation to the Fat-suppression Method and Fat Content. 评估全身MR图像上骨髓ADC与脂肪抑制方法和脂肪含量的关系。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-07-01 Epub Date: 2021-02-09 DOI: 10.2463/mrms.mp.2020-0129
Tetsuya Tsujikawa, Akira Makino, Hiroshi Oikawa, Shota Ishida, Tetsuya Mori, Yasushi Kiyono, Hirohiko Kimura, Hidehiko Okazawa
{"title":"Assessing the ADC of Bone-marrow on Whole-body MR Images in Relation to the Fat-suppression Method and Fat Content.","authors":"Tetsuya Tsujikawa,&nbsp;Akira Makino,&nbsp;Hiroshi Oikawa,&nbsp;Shota Ishida,&nbsp;Tetsuya Mori,&nbsp;Yasushi Kiyono,&nbsp;Hirohiko Kimura,&nbsp;Hidehiko Okazawa","doi":"10.2463/mrms.mp.2020-0129","DOIUrl":"https://doi.org/10.2463/mrms.mp.2020-0129","url":null,"abstract":"<p><strong>Purpose: </strong>To compare apparent diffusion coefficients (ADCs) of bone marrow on diffusion-weighted imaging (DWI) between two fat-suppression techniques, and to evaluate the association between bone-marrow ADCs and the proton density fat fraction (PDFF).</p><p><strong>Methods: </strong>Seventy-seven patients underwent whole-body DWI with short-inversion time inversion-recovery (STIR) (DWI<sub>STIR</sub>) and/or STIR + selective water-excitation (spectral-spatial RF [SSRF]) (DWI<sub>STIR+SSRF</sub>). ADCs of lumbar vertebrae (L3 and L4) were compared between DWI<sub>STIR</sub> and DWI<sub>STIR+SSRF</sub>, and correlated with the PDFF.</p><p><strong>Results: </strong>Lumbar ADCs obtained by DWI<sub>STIR</sub> and DWI<sub>STIR+SSRF</sub> were significantly correlated (L3: r = 0.90, P < 0.0001, L4: r = 0.90, P < 0.0001). Lumbar ADCs (× 10<sup>-6</sup> mm<sup>2</sup>/s) obtained by DWI<sub>STIR</sub> were significantly lower than those by DWI<sub>STIR+SSRF</sub> (L3: 479 ± 137 and 490 ± 148, P < 0.05, L4: 456 ± 114 and 471 ± 118, P < 0.005). Residual fat signals were more clearly observed on DWI<sub>STIR</sub> than on DWI<sub>STIR+SSRF</sub>. The ADCs of L3 obtained by DWI<sub>STIR</sub> and DWI<sub>STIR+SSRF</sub> exhibited significant positive correlations with the PDFF (r = 0.51, P < 0.0001, and r = 0.45, P < 0.0001, respectively), and the ADCs of L4 obtained by DWI<sub>STIR</sub> and DWI<sub>STIR+SSRF</sub> exhibited significantly positive correlations with the PDFF (r = 0.40, P < 0.0005, and r = 0.40, P < 0.0005, respectively).</p><p><strong>Conclusion: </strong>Irrespective of different fat-suppression methods, lumbar ADCs were positively correlated with the PDFF, being inconsistent with previous studies. Lumbar ADCs obtained by DWI<sub>STIR</sub> were significantly lower than those obtained by DWI<sub>STIR+SSRF,</sub> probably due to residual fat signals on DWI<sub>STIR</sub>. However, this difference (< 4%) did not explain the positive correlation between lumbar ADC and PDFF.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a8/15/mrms-21-407.PMC9316130.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25353733","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Dual-VENC 4D Flow MRI Can Detect Abnormal Blood Flow in the Left Atrium That Potentially Causes Thrombosis Formation after Left Upper Lobectomy. 双venc 4D血流MRI可以检测左上肺叶切除术后可能导致血栓形成的左心房异常血流。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-07-01 Epub Date: 2021-03-31 DOI: 10.2463/mrms.mp.2020-0170
Masatoki Nakaza, Mitsuo Matsumoto, Tetsuro Sekine, Tatsuya Inoue, Takahiro Ando, Masashi Ogawa, Makoto Obara, Olgierd Leonowicz, Shinichiro Kumita, Jitsuo Usuda
{"title":"Dual-VENC 4D Flow MRI Can Detect Abnormal Blood Flow in the Left Atrium That Potentially Causes Thrombosis Formation after Left Upper Lobectomy.","authors":"Masatoki Nakaza,&nbsp;Mitsuo Matsumoto,&nbsp;Tetsuro Sekine,&nbsp;Tatsuya Inoue,&nbsp;Takahiro Ando,&nbsp;Masashi Ogawa,&nbsp;Makoto Obara,&nbsp;Olgierd Leonowicz,&nbsp;Shinichiro Kumita,&nbsp;Jitsuo Usuda","doi":"10.2463/mrms.mp.2020-0170","DOIUrl":"https://doi.org/10.2463/mrms.mp.2020-0170","url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of the current study was to clarify the blood flow pattern in the left atrium (LA), potentially causing the formation of thrombosis after left upper lobectomy (LUL). The blood flow in the LA was evaluated and compared between LUL patients with and without thrombosis. For the evaluation, we applied highly accelerated 4D flow MRI with dual-velocity encoding (VENC) scheme, which was expected to be able to capture slow flow components in the LA accurately.</p><p><strong>Methods: </strong>Eight volunteers and 18 patients subjected to LUL underwent dual-VENC 4D Flow MRI. Eight patients had a history of thrombosis. We measured the blood flow velocity and stasis ratio (proportion in the volume that did not exceed 10 cm/s in any cardiac phase) in the LA and left superior pulmonary vein (LSPV) stump. For visual assessment, the presence of each collision of the blood flow from pulmonary veins and vortex flow in the LA were evaluated. Each acquired value was compared between healthy participants and LUL patients, and in LUL patients with and without thrombosis.</p><p><strong>Results: </strong>In LUL patients, blood flow velocity near the inflow part of the left superior pulmonary vein (Lt Upp) and mean velocity in the LA were lower, and stasis ratio in the LA was higher compared with healthy volunteers (Lt Upp 9.10 ± 3.09 vs.13.23 ± 14.19 cm/s, mean velocity in the LA 9.81 ± 2.49 vs. 11.40 ± 1.15 cm/s, and stasis ratio 25.28 ± 18.64 vs. 4.71 ± 3.03%, P = 0.008, 0.037, and < 0.001). There was no significant difference in any quantification values between LUL patients with and without thrombosis. For visual assessment, the thrombus formation was associated with no collision pattern (62.5% vs. 10%, P = 0.019) and not with vortex flow pattern (50% vs. 30%, P = 0.751).</p><p><strong>Conclusion: </strong>The net blood flow velocity was not associated with the thrombus formation. In contrast, a specific blood flow pattern, the absence of blood flow collision from pulmonary veins, correlates to the thrombus formation in the LA.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/84/3f/mrms-21-433.PMC9316132.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25550655","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Comparison of Brain Volume Measurements Made with 0.3- and 3-T MR Imaging. 脑容量测量与0.3和3-T磁共振成像的比较。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-07-01 Epub Date: 2021-07-22 DOI: 10.2463/mrms.tn.2020-0034
Syo Murata, Akifumi Hagiwara, Hideyoshi Kaga, Yuki Someya, Kiyotaka Nemoto, Masami Goto, Koji Kamagata, Ryusuke Irie, Masaaki Hori, Christina Andica, Akihiko Wada, Kanako Kunishima Kumamaru, Keigo Shimoji, Yujiro Otsuka, Haruyoshi Hoshito, Yoshifumi Tamura, Ryuzo Kawamori, Hirotaka Watada, Shigeki Aoki
{"title":"Comparison of Brain Volume Measurements Made with 0.3- and 3-T MR Imaging.","authors":"Syo Murata,&nbsp;Akifumi Hagiwara,&nbsp;Hideyoshi Kaga,&nbsp;Yuki Someya,&nbsp;Kiyotaka Nemoto,&nbsp;Masami Goto,&nbsp;Koji Kamagata,&nbsp;Ryusuke Irie,&nbsp;Masaaki Hori,&nbsp;Christina Andica,&nbsp;Akihiko Wada,&nbsp;Kanako Kunishima Kumamaru,&nbsp;Keigo Shimoji,&nbsp;Yujiro Otsuka,&nbsp;Haruyoshi Hoshito,&nbsp;Yoshifumi Tamura,&nbsp;Ryuzo Kawamori,&nbsp;Hirotaka Watada,&nbsp;Shigeki Aoki","doi":"10.2463/mrms.tn.2020-0034","DOIUrl":"https://doi.org/10.2463/mrms.tn.2020-0034","url":null,"abstract":"<p><p>The volumes of intracranial tissues of 40 healthy volunteers acquired from 0.3- and 3-T scanners were compared using intraclass correlation coefficients, correlation analyses, and Bland-Altman analyses. We found high intraclass correlation coefficients, high Pearson's correlation coefficients, and low percentage biases in all tissues and most of the brain regions, although small differences were observed in some areas. These findings may support the validity of brain volumetry with low-field magnetic resonance imaging.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/7b/ba/mrms-21-517.PMC9316137.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39218784","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Combining the Tumor Contact Length and Apparent Diffusion Coefficient Better Predicts Extraprostatic Extension of Prostate Cancer with Capsular Abutment: A 3 Tesla MR Imaging Study. 结合肿瘤接触长度和表观扩散系数更好地预测包膜基台前列腺癌的前列腺外延伸:一项3特斯拉磁共振成像研究。
IF 3 3区 医学
Magnetic Resonance in Medical Sciences Pub Date : 2022-07-01 Epub Date: 2021-05-20 DOI: 10.2463/mrms.mp.2020-0182
Koichi Ito, Emiko Chiba, Noriko Oyama-Manabe, Satoshi Washino, Osamu Manabe, Tomoaki Miyagawa, Kohei Hamamoto, Masahiro Hiruta, Keisuke Tanno, Hiroshi Shinmoto
{"title":"Combining the Tumor Contact Length and Apparent Diffusion Coefficient Better Predicts Extraprostatic Extension of Prostate Cancer with Capsular Abutment: A 3 Tesla MR Imaging Study.","authors":"Koichi Ito,&nbsp;Emiko Chiba,&nbsp;Noriko Oyama-Manabe,&nbsp;Satoshi Washino,&nbsp;Osamu Manabe,&nbsp;Tomoaki Miyagawa,&nbsp;Kohei Hamamoto,&nbsp;Masahiro Hiruta,&nbsp;Keisuke Tanno,&nbsp;Hiroshi Shinmoto","doi":"10.2463/mrms.mp.2020-0182","DOIUrl":"https://doi.org/10.2463/mrms.mp.2020-0182","url":null,"abstract":"<p><strong>Purpose: </strong>To assess the diagnostic performance of the tumor contact length (TCL) and apparent diffusion coefficient (ADC) for predicting extraprostatic extension (EPE) of prostate cancer with capsular abutment (CA).</p><p><strong>Methods: </strong>Ninety-three patients with biopsy-proven prostate cancer underwent 3-Tesla MRI, including diffusion-weighted imaging (b value = 0, 2000 s/mm<sup>2</sup>) and radical prostatectomy. Two experienced radiologists, blinded to the clinicopathological data, retrospectively assessed the presence of CA on T2-weighted imaging (T2WI). TCL on T2WI and ADC values were measured on detecting CA in prostate cancer. We used the receiver operating characteristic curves to assess the diagnostic performance of TCL and ADC values for predicting EPE.</p><p><strong>Results: </strong>CA was present in 58 prostate cancers among 93 patients. The cut-off value for TCL was 6.9 mm, which yielded an area under the curve (AUC) of 0.75. This corresponded to a sensitivity, specificity, and accuracy of 84.2%, 61.5%, and 69.0%, respectively. The cut-off value for ADC was 0.63 × 10<sup>-3</sup> mm<sup>2</sup>/s, which yielded an AUC of 0.76. This, in turn, corresponded to a sensitivity, specificity, and accuracy of 84.2%, 59.0%, and 67.2%, respectively. The combined cut-off value of TCL and ADC yielded an AUC of 0.82. The specificity (84.6%) and accuracy (81.0%) of the combined value were superior to their individual values (P < 0.05).</p><p><strong>Conclusion: </strong>A combination of TCL and ADC values provided high specificity and accuracy for detecting EPE of prostatic cancer with CA.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":null,"pages":null},"PeriodicalIF":3.0,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/95/54/mrms-21-477.PMC9316129.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38987447","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信