Differentiating Liver Hemangioma from Metastatic Tumor Using T2-enhanced Spin-echo Imaging with a Time-reversed Gradient-echo Sequence in the Hepatobiliary Phase of Gadoxetic Acid-enhanced MR Imaging.
IF 2.5 3区 医学Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
{"title":"Differentiating Liver Hemangioma from Metastatic Tumor Using T2-enhanced Spin-echo Imaging with a Time-reversed Gradient-echo Sequence in the Hepatobiliary Phase of Gadoxetic Acid-enhanced MR Imaging.","authors":"Yukihisa Takayama, Akihiro Nishie, Daisuke Okamoto, Nobuhiro Fujita, Yoshiki Asayama, Yasuhiro Ushijima, Tomoharu Yoshizumi, Masami Yoneyama, Kousei Ishigami","doi":"10.2463/mrms.mp.2020-0151","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the utility of T2-enhanced spin-echo imaging using the time-reversed gradient echo sequence (T2FFE imaging) in the hepatobiliary phase (HBP) of gadoxetic acid-enhanced MRI (Gd-EOB-MRI) for differentiating hemangiomas from metastatic tumors.</p><p><strong>Methods: </strong>A total of 61 patients with 133 liver lesions, including 37 hemangiomas and 96 metastatic tumors, were scanned by Gd-EOB-MRI. Four data sets were independently analyzed by two readers: (1) 3D fat-suppressed T2-weighted imaging (FS-T2WI) alone; (2) the combination of 3D FS-T2WI and T2FFE imaging in the HBP of Gd-EOB-MRI; (3) the combination of 3D FS-T2WI, diffusion-weighted imaging (DWI) with the b-value of 1000 s/mm<sup>2</sup> and the apparent diffusion coefficient (ADC); and (4) a dynamic study of Gd-EOB-MRI. After classifying the lesion sizes as ≤ 10 mm or > 10 mm, we conducted a receiver-operating characteristic analysis to compare diagnostic accuracies among the four data sets for differentiating hemangiomas from metastatic tumors.</p><p><strong>Results: </strong>The areas under the curves (AUCs) of the four data sets of two readers were: (1) ≤ 10 mm (0.85 and 0.91) and > 10 mm (0.88 and 0.97), (2) ≤ 10 mm (0.94 and 0.94) and > 10 mm (0.96 and 0.95), (3) ≤ 10 mm (0.90 and 0.87) and > 10 mm (0.89 and 0.95), and (4) ≤ 10 mm (0.62 and 0.67) and > 10 mm (0.76 and 0.71), respectively. Data sets (2) and (3) showed no significant differences in AUCs, but both showed significantly higher AUCs compared to that of (4) regardless of the lesion size (P < 0.05).</p><p><strong>Conclusion: </strong>The combination of 3D FS-T2WI and T2FFE imaging in the HBP of Gd-EOB-MRI achieved an accuracy equivalent to that of the combination of 3D FS-T2WI, DWI, and ADC and might be helpful in differentiating hemangiomas from metastatic tumors.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":"21 3","pages":"445-457"},"PeriodicalIF":2.5000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/9f/70/mrms-21-445.PMC9316131.pdf","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2020-0151","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/4/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 4
Abstract
Purpose: To evaluate the utility of T2-enhanced spin-echo imaging using the time-reversed gradient echo sequence (T2FFE imaging) in the hepatobiliary phase (HBP) of gadoxetic acid-enhanced MRI (Gd-EOB-MRI) for differentiating hemangiomas from metastatic tumors.
Methods: A total of 61 patients with 133 liver lesions, including 37 hemangiomas and 96 metastatic tumors, were scanned by Gd-EOB-MRI. Four data sets were independently analyzed by two readers: (1) 3D fat-suppressed T2-weighted imaging (FS-T2WI) alone; (2) the combination of 3D FS-T2WI and T2FFE imaging in the HBP of Gd-EOB-MRI; (3) the combination of 3D FS-T2WI, diffusion-weighted imaging (DWI) with the b-value of 1000 s/mm2 and the apparent diffusion coefficient (ADC); and (4) a dynamic study of Gd-EOB-MRI. After classifying the lesion sizes as ≤ 10 mm or > 10 mm, we conducted a receiver-operating characteristic analysis to compare diagnostic accuracies among the four data sets for differentiating hemangiomas from metastatic tumors.
Results: The areas under the curves (AUCs) of the four data sets of two readers were: (1) ≤ 10 mm (0.85 and 0.91) and > 10 mm (0.88 and 0.97), (2) ≤ 10 mm (0.94 and 0.94) and > 10 mm (0.96 and 0.95), (3) ≤ 10 mm (0.90 and 0.87) and > 10 mm (0.89 and 0.95), and (4) ≤ 10 mm (0.62 and 0.67) and > 10 mm (0.76 and 0.71), respectively. Data sets (2) and (3) showed no significant differences in AUCs, but both showed significantly higher AUCs compared to that of (4) regardless of the lesion size (P < 0.05).
Conclusion: The combination of 3D FS-T2WI and T2FFE imaging in the HBP of Gd-EOB-MRI achieved an accuracy equivalent to that of the combination of 3D FS-T2WI, DWI, and ADC and might be helpful in differentiating hemangiomas from metastatic tumors.
期刊介绍:
Magnetic Resonance in Medical Sciences (MRMS or Magn
Reson Med Sci) is an international journal pursuing the
publication of original articles contributing to the progress
of magnetic resonance in the field of biomedical sciences
including technical developments and clinical applications.
MRMS is an official journal of the Japanese Society for
Magnetic Resonance in Medicine (JSMRM).