TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference最新文献

筛选
英文 中文
Closed-Loop Transductor-Compensated Class E Driver for Inductive Links 电感链路的闭环传感器补偿E类驱动器
B. Lenaerts, F. Peeters, R. Puers
{"title":"Closed-Loop Transductor-Compensated Class E Driver for Inductive Links","authors":"B. Lenaerts, F. Peeters, R. Puers","doi":"10.1109/SENSOR.2007.4300072","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300072","url":null,"abstract":"When a class E circuit is employed to drive an inductive link, very little tolerance is allowed on the inductance value of the transmitter coil. Deformable coils are thus not compatible with an open- loop class E design. By connecting a transductor in series with the transmitter inductance, it is possible to keep the total class E inductance constant, regardless of the transmitter coil deformation. This is achieved through a control loop that steers the transductor to the appropriate inductance value. For the realized closed-loop circuit, class E regime is maintained for inductance variations of the transmitter coil of up to 27 %. The principal advantage of transductor control compared to earlier reported techniques, is the fixed frequency of operation.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"30 1","pages":"65-68"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81101340","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Metal-Transfer-Micromolding of Air-Lifted RF Components 空气提升射频元件的金属传递微成型
Yanzhu Zhao, Y. Yoon, Xiaosong Wu, M. Allen
{"title":"Metal-Transfer-Micromolding of Air-Lifted RF Components","authors":"Yanzhu Zhao, Y. Yoon, Xiaosong Wu, M. Allen","doi":"10.1109/SENSOR.2007.4300216","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300216","url":null,"abstract":"This paper reports a metal-transfer-micromolding (MTM) technique for simultaneous implementation of metallized high aspect ratio molded polymer RF passive components, as well as coplanar waveguide feeding structures, in a high performance and potentially cost-effective fashion. Applications of the MTM technique in air-lifted RF components such as Ka-band monopole antennas and evanescent mode cavity resonators have been demonstrated. A 21.5% 10 dB bandwidth for the monopole antenna, and an unloaded Q exceeding 500 for the resonators, are achieved from micromolded organic materials.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"11 1","pages":"659-662"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85550192","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Effects of Microchannel Cross-Section and Applied Electric Field on Electroosmotic Mobility 微通道截面和外加电场对电渗透迁移率的影响
A. Bhagat, S. Dasgupta, R. Banerjee, I. Papautsky
{"title":"Effects of Microchannel Cross-Section and Applied Electric Field on Electroosmotic Mobility","authors":"A. Bhagat, S. Dasgupta, R. Banerjee, I. Papautsky","doi":"10.1109/SENSOR.2007.4300517","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300517","url":null,"abstract":"In this work we report on the numerical and experimental investigation of the effects of channel cross-section and applied electric field on electroosmotic flow (EOF) mobility in polydimethylsiloxane (PDMS)/glass hybrid microchannels. The experimental results are used to calibrate and validate the simulation model to solve the Navier-Stokes equation for fluid flow and Poisson equation to resolve the external electric field. According to the Helmholtz Smoluchowski equation the electroosmotic mobility (muEO) is independent of channel cross-section and applied electric field. Contrary to the above relationship, the results presented in this work indicate that muEO is not constant but changes with channel cross-section as well as the applied electric field. The results of this work will be useful in determining the optimum channel dimensions for a desired electroosmotic velocity at a given applied electric field.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"27 1","pages":"1853-1856"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85700712","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
MEMS Tunable Dual-Wavelength Laser with Large Tuning Range 大调谐范围MEMS可调谐双波长激光器
H. Cai, X.M. Zhang, J. Wu, D. Tang, Q. Zhang, A. Liu
{"title":"MEMS Tunable Dual-Wavelength Laser with Large Tuning Range","authors":"H. Cai, X.M. Zhang, J. Wu, D. Tang, Q. Zhang, A. Liu","doi":"10.1109/SENSOR.2007.4300413","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300413","url":null,"abstract":"This paper presents a MEMS tunable dual-wave length laser, which simultaneously achieves wide tuning range and two-longitudinal-mode emission. The construction of this laser is based on Littman external cavity configuration. The key point is to use two micro-mirrors to select two different wavelengths at their independent diffraction modes, and the emission of both wavelengths will be collected through the 0th order of the grating. Meanwhile, wavelength tuning is achieved by rotating one of the mirrors. As a result, a tunable spectral separation of dual-wave length output is obtained. The MEMS device is fabricated by DRIE on SOI wafer, with the size of 3 mm times 3 mm.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"70 1","pages":"1433-1436"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84097932","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Design and Test of a Novel Higher Harmonic Imaging AFM Probe with a Dedicated Second Cantilever for Harmonic Amplification 一种新型高谐波成像AFM探针的设计与测试,该探针具有用于谐波放大的专用第二悬臂
B. Zeyen, K. Turner
{"title":"Design and Test of a Novel Higher Harmonic Imaging AFM Probe with a Dedicated Second Cantilever for Harmonic Amplification","authors":"B. Zeyen, K. Turner","doi":"10.1109/SENSOR.2007.4300440","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300440","url":null,"abstract":"We report on design, fabrication and initial testing of a new higher harmonic imaging atomic force microscopy (AFM) probe for the characterization of materials at the nanoscale. In contrast to previous designs, this probe employs a dedicated second cantilever not only to amplify the desired higher harmonic, but also to suppress the actuation movement. With these measures the amplitudes of the actuation and the higher harmonic are brought closer together on the second cantilever, which is very advantageous for single-channel readout applications.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"48 1","pages":"1545-1548"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"78020350","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Electrical and Mechanical Characteristics of DNA Bundles Revealed by Silicon Nanotweezers 硅纳米镊子揭示DNA束的电学和力学特性
C. Yamahata, T. Takekawa, M. Kumemura, M. Hosogi, Gen Hashiguchi, Dominique Collard, Hiroyuki Fujita
{"title":"Electrical and Mechanical Characteristics of DNA Bundles Revealed by Silicon Nanotweezers","authors":"C. Yamahata, T. Takekawa, M. Kumemura, M. Hosogi, Gen Hashiguchi, Dominique Collard, Hiroyuki Fujita","doi":"10.1109/SENSOR.2007.4300151","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300151","url":null,"abstract":"This paper deals with the first simultaneous electrical and mechanical characterization of DNA bundles by a MEMS tool. The silicon-based device has an integrated actuator and a differential capacitive position sensor. Our experiments show that under constant humidity conditions, a rope of DNA has a nearly Ohmic conductivity and behaves as a viscoelastic material.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"5 1","pages":"395-398"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72861794","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Electrostatic Latch Mechanism for Handling Projection on Arrayed Vertical Motion System 阵列垂直运动系统上处理投影的静电锁存机构
S. Takagi, H. Sasaki, M. Shikida, K. Sato
{"title":"Electrostatic Latch Mechanism for Handling Projection on Arrayed Vertical Motion System","authors":"S. Takagi, H. Sasaki, M. Shikida, K. Sato","doi":"10.1109/SENSOR.2007.4300338","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300338","url":null,"abstract":"We have previously proposed an arrayed vertical motion system based on a tulip-shaped electrostatic clutch for producing haptic displays. The system has an advantage in that it is able to individually operate arrayed end-effecter elements with high-power and large strokes (output: 600 mN and displacement: 60 mum). We added a new electrostatic latch mechanism to the system to individually control the projection state. We used MEMS technologies to fabricate a 4times4 array electrostatic latch mechanism. The total size of the mechanism was 6.0 times 6.0 times 0.5 mm. We evaluated the relationship between the applied voltage and a holding force of a few mN was obtained for the spring device.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"188 1","pages":"1147-1150"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73281451","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Fabrication and Packaging of Nanoporous Membrane Chips for Label-Free Ion-Channel Transducer Based Biosensor 无标签离子通道传感器纳米孔膜芯片的制备与封装
V. Agache, F. Sauter, C. Pudda, R. Blanc, C. Chabrol, P. Caillat, T. Plénat, A. V. Agasøster, L. Ghenim, A. Fuchs
{"title":"Fabrication and Packaging of Nanoporous Membrane Chips for Label-Free Ion-Channel Transducer Based Biosensor","authors":"V. Agache, F. Sauter, C. Pudda, R. Blanc, C. Chabrol, P. Caillat, T. Plénat, A. V. Agasøster, L. Ghenim, A. Fuchs","doi":"10.1109/SENSOR.2007.4300256","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300256","url":null,"abstract":"This paper relates to a new architecture of label-free Ion channel based biosensors. The biochips are composed of nanoaperture arrays etched in a free-standing silicon nitride (Si3N4) supporting membrane. These membranes should be covered lately by a lipid bilayer which hosts bioengineered protein receptors-gated ion channels. This protein complex is used to convert specific binding events with target molecules into an electrical signal. This paper is focusing on the fabrication and packaging of the device.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"169 1","pages":"819-822"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73398056","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
High-Throughput Single-Cell Electroporation Microchip with Three Dimensional Si Microelectrodes for Gene Transfection 高通量单细胞电穿孔芯片与三维硅微电极基因转染
Y. Cho, S. Lee, B. Le Pioufle, N. Takama, S. Takeuchi, T. Fujii, B.J. Kim
{"title":"High-Throughput Single-Cell Electroporation Microchip with Three Dimensional Si Microelectrodes for Gene Transfection","authors":"Y. Cho, S. Lee, B. Le Pioufle, N. Takama, S. Takeuchi, T. Fujii, B.J. Kim","doi":"10.1109/SENSOR.2007.4300286","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300286","url":null,"abstract":"We present details on fabrication of electroporation microchip, practical experiments of single-cell electroporation with our fabricated microchip. Also, the continuous electroporation for the continuous flow of cells is used for high-throughput electroporation. The delivery efficiency and cell viability tests are provided and the successful GFP transfection into cells is also evaluated with a fluorescent microscope after electroporation.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"1079 1","pages":"939-942"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76697169","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Gas Flowin Nano-Channels: Thermal Transpirationmodelswith Application to a Si-Micromachinedknudsen Pump 气体流动在纳米通道:热蒸腾模型与应用于硅微机械克努森泵
N. Gupta, N. Masters, W. Ye, Y. Gianchandani
{"title":"Gas Flowin Nano-Channels: Thermal Transpirationmodelswith Application to a Si-Micromachinedknudsen Pump","authors":"N. Gupta, N. Masters, W. Ye, Y. Gianchandani","doi":"10.1109/SENSOR.2007.4300636","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300636","url":null,"abstract":"This paper presents a comparative study of performance of various analytical and semi-analytical models used for the analysis of rarefied gas flow, which is responsible for the phenomenon of thermal transpiration. In particular, these are evaluated in the context of the scaling analysis of a Si-micromachined monolithic Knudsen pump. Results from these models are verified using available experimental data and are benchmarked against the simulation results from direct simulation Monte Carlo (DSMC) technique. Characterization of Sharipov's model against the DSMC technique with the help of specially designed test cases predicts that Sharipov's model is potentially the most representative model for DSMC in this context. Finally, Sharipov's model is used to evaluate the sensitivity analysis of structural and performance parameters relevant for thermal transpiration. The analysis shows that for a 200 mum long channel on a well-insulated glass substrate, with a channel height of 100 nm and 10 mum width, provides a mass flow rate of 1.5times10-6 sccm with a DeltaT of 300degC.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"87 1","pages":"2329-2332"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76824305","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信