Indoor air最新文献

筛选
英文 中文
A Comprehensive Index for Evaluating the Effectiveness of Ventilation-Related Infection Prevention Measures with Energy Considerations: Development and Application Perspectives 评估与通风相关的感染预防措施有效性的综合指标,其中考虑到能源因素:开发与应用视角
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2024-02-03 DOI: 10.1155/2024/9819794
Ruben Makris, Claudia Kopic, Lukas Schumann, Martin Kriegel
{"title":"A Comprehensive Index for Evaluating the Effectiveness of Ventilation-Related Infection Prevention Measures with Energy Considerations: Development and Application Perspectives","authors":"Ruben Makris,&nbsp;Claudia Kopic,&nbsp;Lukas Schumann,&nbsp;Martin Kriegel","doi":"10.1155/2024/9819794","DOIUrl":"10.1155/2024/9819794","url":null,"abstract":"<p>In the wake of the COVID-19 pandemic, prioritizing indoor air quality has emerged as a crucial measure for preventing infections. Effective ventilation is vital in mitigating airborne pathogen transmission and maintaining a healthy indoor environment by diluting and removing infectious particles from enclosed spaces. However, increasing the supply of pathogen-free air to enhance infection control can lead to a rise in energy consumption. Nevertheless, evaluating the overall efficacy of ventilation-based infection prevention strategies while considering their energy requirements has posed challenges. This scientific paper introduces the ICEE (Infection Control’s Energy Efficiency) index, a newly developed simple integrated index to assess the effectiveness of ventilation strategies in reducing infection risks while accounting for associated energy demands. The paper reviews the current understanding of ventilation strategies, their impact on infection prevention, and their corresponding energy consumption. By employing a straightforward analytical approach, this metric offers a comprehensive framework to optimize ventilation systems for both infection prevention and energy efficiency. To quantify infection risk, a simplified equation model is utilized, incorporating factors such as ventilation effectiveness and filter efficiency, in case of recirculation. Energy demand is determined using approximations and relevant values from existing literature. Reference cases are defined, distinguishing between natural and mechanically ventilated scenarios, as these reference situations influence the energy-related effects of any implemented measures. The paper outlines the methodology employed to develop the index and illustrates its applicability through exemplary measures. The proposed index yields valuable insights for the design, operation, and retrofitting of ventilation systems, enabling informed decision-making towards fostering a healthier and more sustainable built environment.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2024 1","pages":""},"PeriodicalIF":5.8,"publicationDate":"2024-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139807485","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Enhancing PM2.5 Measurement Accuracy: Insights from Environmental Factors and BAM-Light Scattering Device Correlation 提高 PM2.5 测量精度:从环境因素和 BAM-光散射装置相关性中获得的启示
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2024-01-31 DOI: 10.1155/2024/2930582
Minju Kim, Hajin Choi, Jeonghun Lee, Su-Gwang Jeong
{"title":"Enhancing PM2.5 Measurement Accuracy: Insights from Environmental Factors and BAM-Light Scattering Device Correlation","authors":"Minju Kim,&nbsp;Hajin Choi,&nbsp;Jeonghun Lee,&nbsp;Su-Gwang Jeong","doi":"10.1155/2024/2930582","DOIUrl":"10.1155/2024/2930582","url":null,"abstract":"<p>Studies investigating the correlation between particulate matter (PM) concentrations measured by a light scattering (LS) device and environmental factors are crucial to identify LS values with significant errors. Herein, the relationship between PM<sub>2.5</sub> obtained through beta attenuation monitoring (BAM) and LS was examined with respect to seven environmental factors. Machine learning (ML) and general statistical methods were employed to reveal complex relationships. Data from five cities were initially analyzed to understand the association between BAM measurements and environmental factors. Our findings confirmed that wind direction (WD) had a strong nonlinear impact on short-term measurements, whereas temperature and local pressure had similar effects on long-term PM<sub>2.5</sub> measurements. Subsequently, a method was developed using general statistical techniques to establish an environment wherein LS could maintain a relatively high accuracy level. Furthermore, ML techniques were employed to determine that LS was more affected (by 8.2%) by the changes in WD compared with BAM, emphasizing the importance of designing devices capable of responding to WD. Finally, LS was calibrated using four ML algorithms, and through a quantitative evaluation of coefficient of determination, mean absolute error, and root mean square error values, AdaBoost was identified as an effective algorithm for correcting LS measurements. With this understanding of the correlation between PM<sub>2.5</sub> and environmental factors, along with an efficient correction method, its widespread adoption in future research concerning real-time PM measurement is anticipated.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2024 1","pages":""},"PeriodicalIF":5.8,"publicationDate":"2024-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140479685","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Direct Infection Risk Model for CFD Predictions and Its Application to SARS-CoV-2 Aircraft Cabin Transmission 用于 CFD 预测的直接感染风险模型及其在 SARS-CoV-2 飞机机舱传播中的应用
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2024-01-25 DOI: 10.1155/2024/9927275
Florian Webner, Andrei Shishkin, Daniel Schmeling, Claus Wagner
{"title":"A Direct Infection Risk Model for CFD Predictions and Its Application to SARS-CoV-2 Aircraft Cabin Transmission","authors":"Florian Webner,&nbsp;Andrei Shishkin,&nbsp;Daniel Schmeling,&nbsp;Claus Wagner","doi":"10.1155/2024/9927275","DOIUrl":"10.1155/2024/9927275","url":null,"abstract":"<p>Current models to determine the risk of airborne disease infection are typically based on a backward quantification of observed infections, leading to uncertainties, e.g., due to the lack of knowledge whether the index person was a superspreader. In contrast, the present work presents a forward infection risk model that calculates the inhaled dose of infectious virus based on the virus emission rate of an emitter and a prediction of Lagrangian particle trajectories using CFD, taking both the residence time of individual particles and the biodegradation rate into account. The estimation of the dose-response is then based on data from human challenge studies. Considering the available data for SARS-CoV-2 from the literature, it is shown that the model can be used to estimate the risk of infection with SARS-CoV-2 in the cabin of a Do728 single-aisle aircraft. However, the virus emission rate during normal breathing varies between different studies and also by about two orders of magnitude within one and the same study. A sensitivity analysis shows that the uncertainty in the input parameters leads to uncertainty in the prediction of the infection risk, which is between 0 and 12 infections among 70 passengers. This highlights the importance and challenges in terms of superspreaders for risk prediction, which are difficult to capture using standard backward calculations. Further, biological inactivation was found to have no significant impact on the risk of infection for SARS-CoV-2 in the considered aircraft cabin.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2024 1","pages":""},"PeriodicalIF":5.8,"publicationDate":"2024-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139598537","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Estimates of Inhaled and Deposited Doses following Exposure to Humidifier Disinfectant Containing Polyhexamethylene Guanidine (PHMG) 接触含有聚六亚甲基胍 (PHMG) 的加湿器消毒剂后的吸入和沉积剂量估计值
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2024-01-24 DOI: 10.1155/2024/8815592
Sunju Kim, Chungsik Yoon
{"title":"Estimates of Inhaled and Deposited Doses following Exposure to Humidifier Disinfectant Containing Polyhexamethylene Guanidine (PHMG)","authors":"Sunju Kim,&nbsp;Chungsik Yoon","doi":"10.1155/2024/8815592","DOIUrl":"10.1155/2024/8815592","url":null,"abstract":"<p>We estimated the inhaled and deposited dose in humans using the International Commission on Radiological Protection (ICRP) and multiple-path particle dosimetry (MPPD) models following exposure to humidifier disinfectant containing polyhexamethylene guanidine (PHMG). The disinfectant has caused at least 1,810 deaths, with an odds ratio of lung injury of 47.3 (95% confidence interval: 6.1–369.7), because of its application in Korea. In this study, the Oxy product, which is regarded as the causative agent of most lung diseases, was sprayed into a cleanroom at normal (6.5 ppm in solution) and worst case (65 ppm in solution) dilutions; the airborne aerosol was monitored with direct reading instruments. Areas of deposition were divided into the head airway, tracheobronchial, and alveolar regions. Four dose scenarios were considered in this study: adults and children in both daily average and sleep conditions. Most PHMG aerosols were smaller than PM1 (96%). Number-based concentration analysis showed that &lt;100 nm nanoparticles comprised 81% and 69% of the aerosol when the 6.5 and 65 ppm solutions were used, respectively. In all scenarios, the number-based deposited dose increased in the order of alveolar, tracheobronchial, and head airway regions; the mass-based deposited dose increased in the order of the head airway, alveolar, and tracheobronchial regions. The deposited dose per unit body weight was higher in children than in adults in terms of both number- and mass-based concentrations. When the humidifier was sprayed, the highest number-based concentration was found at a particle size of 15.4 nm; the highest deposition fraction or dose by PM1 was observed in the pulmonary and head airways in both models.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2024 1","pages":""},"PeriodicalIF":5.8,"publicationDate":"2024-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139602512","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Link between Secondhand Smoke Exposure and Obstructive Sleep Apnea among Nonsmoking U.S General Adults: Finding from the National Health and Nutrition Examination Survey 2015-2020 不吸烟的美国成年人中二手烟暴露与阻塞性睡眠呼吸暂停之间的联系:2015-2020年全国健康与营养调查的结果
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2024-01-20 DOI: 10.1155/2024/8604008
Jing-hong Liang, Shao-yi Huang, Mei-ling Liu, Nan Jiang, Shan Huang, Ying-qi Pu, Yu Zhao, Yi-can Chen, Aerziguli Kakaer, Xue-ya Pu, Guang-hui Dong, Ya-jun Chen
{"title":"Link between Secondhand Smoke Exposure and Obstructive Sleep Apnea among Nonsmoking U.S General Adults: Finding from the National Health and Nutrition Examination Survey 2015-2020","authors":"Jing-hong Liang,&nbsp;Shao-yi Huang,&nbsp;Mei-ling Liu,&nbsp;Nan Jiang,&nbsp;Shan Huang,&nbsp;Ying-qi Pu,&nbsp;Yu Zhao,&nbsp;Yi-can Chen,&nbsp;Aerziguli Kakaer,&nbsp;Xue-ya Pu,&nbsp;Guang-hui Dong,&nbsp;Ya-jun Chen","doi":"10.1155/2024/8604008","DOIUrl":"10.1155/2024/8604008","url":null,"abstract":"<p>The association between secondhand smoke exposure (SHSE) and obstructive sleep apnea (OSA) in general adults remains to be explored and therefore is investigated based on the representative National Health and Nutrition Examination Survey (NHANES) in this study. SHSE was assessed by self-reporting of passive exposure to burning cigarette in an indoor area (home, restaurant or bar, etc.), and OSA was defined by self-reporting OSA-related symptoms and frequency. A survey-weighted regression model and stratified analyses were used to estimate the association between SHSE and odds of OSA. The study involved 9,991 participants who had never smoked, representing a weighted number of 449.9 million adults ranging from 20 to 80 years old in the noninstitutionalized U. S population. There was a strong association between several kinds of SHSEs and OSA that compared with participants staying indoors without exposure to secondhand smoke (SHS), the odds of OSA was 1.2 times higher for those with SHSE at home (adjusted odds ratio (AOR) = 1.225, 95% CI: 1.009, 1.484), 1.4 times higher for those with SHSE in car (AOR = 1.404, 95% CI: 1.219, 1.616), and 1.3 times higher for those with e-cigarette SHSE (AOR = 1.302, 95% CI: 1.087, 1.557). Participants with simultaneous exposure to more different SHSs were 36% (one to three kinds of SHSEs (AOR = 1.368, 95% CI: 1.219, 1.534)) and 44% (above four kinds of SHSEs (AOR = 1.444, 95% CI: 1.034, 2.004)) more likely to have OSA, respectively. In general, general adults with SHSE in separate indoor areas, especially those with simultaneous exposure to different SHSs, had higher OSA risk. Identifying causality and health consequences of the association requires future longitudinal studies.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2024 1","pages":""},"PeriodicalIF":5.8,"publicationDate":"2024-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139524160","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Thermal Comfort Model Established by Using Machine Learning Strategies Based on Physiological Parameters in Hot and Cold Environments 利用基于冷热环境生理参数的机器学习策略建立热舒适模型
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2024-01-19 DOI: 10.1155/2024/9427822
Tseng-Fung Ho, Hsin-Han Tsai, Chi-Chih Chuang, Dasheng Lee, Xi-Wei Huang, Hsiang Chen, Chin–Chi Cheng, Yaw-Wen Kuo, Hsin-Hung Chou, Wei-Han Hsiao, Ching Hsu Yang, Yung-Hui Li
{"title":"Thermal Comfort Model Established by Using Machine Learning Strategies Based on Physiological Parameters in Hot and Cold Environments","authors":"Tseng-Fung Ho,&nbsp;Hsin-Han Tsai,&nbsp;Chi-Chih Chuang,&nbsp;Dasheng Lee,&nbsp;Xi-Wei Huang,&nbsp;Hsiang Chen,&nbsp;Chin–Chi Cheng,&nbsp;Yaw-Wen Kuo,&nbsp;Hsin-Hung Chou,&nbsp;Wei-Han Hsiao,&nbsp;Ching Hsu Yang,&nbsp;Yung-Hui Li","doi":"10.1155/2024/9427822","DOIUrl":"10.1155/2024/9427822","url":null,"abstract":"<p>The air-conditioning systems have become an indispensable part of our daily life for keeping the quality of life. However, to improve the thermal comfort and reduce energy consumption is crucial to use the air conditioners effectively with rapid development of artificial intelligence technology. This study explored the correlation between the response of human physiological parameters and thermal sensation voting (TSV) to evaluate the comfort level among various cold and hot stimulations. The variations of the three physiological parameters, which were body surface temperature, skin blood flow (SBF), and sweat area on the skin surface, and TSV values were all positively correlated with the stimulation amount under the stimulation of cold wind, hot wind, and heat radiation, but the relationship was not completely linear. Among the three physiological parameters, the forehead skin temperature has the closest relationship with TSV, followed by the SBF and sweat. Among three stimulations, the cold wind stimulation causes the closest relationship between TSV and forehead temperature, followed by the radiation and hot wind stimulations. Through three different machine learning models, namely, random forest (RF) model, support vector machine (SVM) model, and neural network (NN) model, the stimulation of cold wind, hot wind, and heat radiation was applied to investigate the variation of the three physiological parameters as the input of the models. Moreover, the models were evaluated and verified by TSV. The results revealed that among the three different machine learning methods, RF had the best accuracy. The established thermal comfort models can predict the real-time user’s thermal comfort feeling, so that air-conditioning equipment’s performance can be optimized to create a healthy and energy-saving comfortable environment.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2024 1","pages":""},"PeriodicalIF":5.8,"publicationDate":"2024-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139525656","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Characterization of Polyhexamethylene Guanidine Oligomers in Solutions and Aerosols Emitted during Humidifier Use 加湿器使用过程中排放的溶液和气溶胶中聚六亚甲基胍低聚物的特性分析
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2024-01-06 DOI: 10.1155/2024/7477565
Sunju Kim, Chungsik Yoon
{"title":"Characterization of Polyhexamethylene Guanidine Oligomers in Solutions and Aerosols Emitted during Humidifier Use","authors":"Sunju Kim,&nbsp;Chungsik Yoon","doi":"10.1155/2024/7477565","DOIUrl":"10.1155/2024/7477565","url":null,"abstract":"<p>The behavior of polyhexamethylene guanidine (PHMG), the causative agent of many humidifier-induced lung diseases, is not well known because of its various oligomer structures and analytical difficulties. The aim of this study was to identify different PHMG oligomer types both in solution and aerosols and to estimate the airborne concentration of oligomers during humidifier use. Three products containing PHMG as the main component were diluted to the manufacturer’s recommended concentration (6.5 ppm) or the worst-case concentration (65 ppm or 125 ppm). Samples were qualitatively and quantitatively analyzed with liquid chromatography-quadrupole time-of-flight (LC-qToF) mass spectrometry in the diluted solution and in the air at 0.5 m and 1 m. The LC-qToF data were processed using UNIFI software to characterize the PHMG structure. For all products in both the humidifier solution and air, the linear type was predominant over the branched/cyclic structure, but each product had different characteristics. The linear structure in the Oxy product, the main product of lung diseases, accounted for 90.6%, while that of the Scunder and BOC Sciences’ products accounted for 78.6% and 75.8%, respectively. The concentration of the oligomer in air for the Oxy product was estimated to be 35.89 and 390.96 <i>μ</i>g/m<sup>3</sup> at 6.5 and 65 ppm, respectively. Most of the oligomers in the solution were found in air at a short distance (0.5 m), with a negligible concentration beyond 1 m. Oligomers with 1–7 monomer units were identified in the humidifier solution, whereas mainly monomers, dimers, and trimers were identified in the air. The results of this study will facilitate further investigations of the mechanisms of lung disease by identifying the behaviors and forms of PHMG in the air, along with previously revealed toxicity results.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2024 1","pages":""},"PeriodicalIF":5.8,"publicationDate":"2024-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139380814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Field Investigations on Subjective Perception, Physiological Responses, and Cognitive Performance under Increasing CO2 Concentration in an Underground Confined Space 地下密闭空间二氧化碳浓度增加时主观感知、生理反应和认知能力的实地调查
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2024-01-05 DOI: 10.1155/2024/5781565
Zongqiao Xie, Qiwei Wang, Kun Zhou, Linjian Ma, Jing Wang, Yong Li, Shangyuan Chen, Weizhi Wei
{"title":"Field Investigations on Subjective Perception, Physiological Responses, and Cognitive Performance under Increasing CO2 Concentration in an Underground Confined Space","authors":"Zongqiao Xie,&nbsp;Qiwei Wang,&nbsp;Kun Zhou,&nbsp;Linjian Ma,&nbsp;Jing Wang,&nbsp;Yong Li,&nbsp;Shangyuan Chen,&nbsp;Weizhi Wei","doi":"10.1155/2024/5781565","DOIUrl":"10.1155/2024/5781565","url":null,"abstract":"<p>The objective of this research was to explore the impacts of heightened CO<sub>2</sub> concentrations on human health and wellness in an underground confined space. A total of 180 participants were subjected to CO<sub>2</sub> concentrations ranging from 1000 to 10000 ppm within a confined underground environment. The study assessed not only subjective perceptions and physiological responses but also cognitive performance, integrating novel measures such as emotion, skin conductance (SC), and heart rate variability (HRV). The findings demonstrated a notable variation in thermal sensation votes (TSV) and perceived air quality acceptability with the change in CO<sub>2</sub> concentration. A significant increase in total mood disturbance (TMD) of 1.5 units was observed at a CO<sub>2</sub> concentration of 8500 ppm, compared to 1000 ppm. Cognitive performance remained consistent for concentrations below 8500 ppm; however, a substantial alteration was noted at 10000 ppm. In terms of task difficulty, numerical calculations were perceived to require 0.74 units more effort than letter searches. As CO<sub>2</sub> concentration exceeded 7500 ppm, significant variances were noted in physiological parameters such as diastolic blood pressure (DBP), heart rate (HR), LF/HF, MF/HF ratios, PNN 50, and frequency domains of HRV (LF, MF, and HF) in comparison to the parameters at 1000 ppm. At 8500 ppm, the LF and HF parameters were found to be 780 and 452.3 units, respectively, higher than at 7000 ppm. These findings suggest that high humidity, low temperature, and elevated CO<sub>2</sub> concentrations collectively contribute to the significant human stress responses. This study is of interest as there are limited reported researches on the air quality in underground confined space.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2024 1","pages":""},"PeriodicalIF":5.8,"publicationDate":"2024-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139381284","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Investigation of the Emission Rate of Particles when Musicians Play Wind, Woodwind, and Brass Instruments 音乐家演奏管乐器、木管乐器和铜管乐器时的粒子发射率调查
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2023-12-21 DOI: 10.1155/2023/8092828
L. Schumann, Dorothea von Zadow, Alexander Schmidt, I. Fernholz, A. Hartmann, Liliana Ifrim, Martin Kriegel, Joachim Seybold, Dirk Mürbe, M. Fleischer
{"title":"Investigation of the Emission Rate of Particles when Musicians Play Wind, Woodwind, and Brass Instruments","authors":"L. Schumann, Dorothea von Zadow, Alexander Schmidt, I. Fernholz, A. Hartmann, Liliana Ifrim, Martin Kriegel, Joachim Seybold, Dirk Mürbe, M. Fleischer","doi":"10.1155/2023/8092828","DOIUrl":"https://doi.org/10.1155/2023/8092828","url":null,"abstract":"In the context of the high risk of airborne transmission of COVID-19, the question of the production of particles while playing wind instruments is highly relevant. Therefore, in this study, 23 professional musicians played their instruments in a cleanroom in cleanroom-grade clothing. The most common orchestral wind instruments flute, oboe, clarinet, and trumpet were therefore chosen. Aerosol measurements using a laser particle counter were conducted to quantify the emission rate of respiratory particles. Orchestral excerpts as well as sustained tones in two dynamic levels were played. The emitted particles were mostly in a submicron size range. For all instruments besides the clarinet, an influence of the loudness of playing on the emission rate could be observed. The emission rates for all musical instruments were independent of the passages played. Flute and oboe showed similar emission rates but lower than the values for clarinet and trumpet. While playing a note with a small volume, the flute, oboe, and trumpet have a similar emission rate as found for speaking.","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"26 14","pages":""},"PeriodicalIF":5.8,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138948050","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Airborne Pollutant Removal Effectiveness and Hidden Pollutant Source Identification of Bionic Ventilation Systems: Direct and Inverse CFD Demonstrations 仿生通风系统的空气污染物去除效果和隐性污染源识别:直接和反向 CFD 演示
IF 5.8 2区 环境科学与生态学
Indoor air Pub Date : 2023-12-16 DOI: 10.1155/2023/5522169
Hong-Liang Zhang, Bin Li, Jin Shang, Wei-Wei Wang, Fu-Yun Zhao
{"title":"Airborne Pollutant Removal Effectiveness and Hidden Pollutant Source Identification of Bionic Ventilation Systems: Direct and Inverse CFD Demonstrations","authors":"Hong-Liang Zhang, Bin Li, Jin Shang, Wei-Wei Wang, Fu-Yun Zhao","doi":"10.1155/2023/5522169","DOIUrl":"https://doi.org/10.1155/2023/5522169","url":null,"abstract":"A healthy and efficient ventilation system is essential for establishing a comfortable indoor environment and significantly reducing a building’s energy demand simultaneously. This paper proposed a novel ventilation system and applied it to the IEA Annex 20 mixing ventilation enclosure to verify its feasibility through mathematical modeling and CFD simulations. First, two bionic ventilation systems, single-side and dual-side ventilations, were compared to a conventional constant-volume supply system using CFD simulations, with the results demonstrating that the bionic ventilation system could provide higher ventilation efficiency and more effective pollutant removal from stagnant regions. Furthermore, the present work exercised these two bionic ventilation systems with different temporal periods of sine and rectangular wave functions, identifying a turning point at a period of 0.06 \u0000 \u0000 \u0000 \u0000 τ\u0000 \u0000 \u0000 n\u0000 \u0000 \u0000 \u0000 , which could contribute to further enhancement of these bionic ventilation systems. Finally, a methodology depending on the Bayesian inference algorithm was developed for identifying pollution sources in the bionic ventilation system with unstable flow fields, and factors influencing source identification accuracy were discussed. The results show that the peaks of the KDE distributions and the sampling average values of both the source location and intensity are all consistent with the actual source parameters. The potential of the proposed bionic ventilation systems has been well demonstrated by direct and inverse CFD models, paving the way for further engineering applications.","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"19 11","pages":""},"PeriodicalIF":5.8,"publicationDate":"2023-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138967458","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信