Furkan Yapici, Volker Maus, Werner Weber, Cengizhan Acikel, Ansgar Berlis, Sebastian Fischer
{"title":"Exploring the relationship between case volume and intracranial aneurysm treatments with flow-diverters and flow-disruptors: Insights from the 2020 to 2021 Database of the German Society for Interventional Radiology National Registry in Germany.","authors":"Furkan Yapici, Volker Maus, Werner Weber, Cengizhan Acikel, Ansgar Berlis, Sebastian Fischer","doi":"10.1177/15910199241249509","DOIUrl":"10.1177/15910199241249509","url":null,"abstract":"<p><p>Background and PurposeIntracranial aneurysm treatment using flow-diverters and flow-disruptors requires a higher level of expertise when compared to more traditional methods. Our hypothesis was that the procedural success and the rate of complications are dependent on the annual case load of a center.Materials and MethodsConducting a retrospective analysis on the Database of the German Society for Interventional Radiology for the years 2020 to 2021, we examined flow-diverter and flow-disruptor procedures. We categorized centers into four groups according to their annual case load and proceeded to analyze success rates, complication rates, and fluoroscopy times across these centers.ResultsNo statistically significant differences were observed among the groups in both flow-diverter and flow-disruptor cases concerning fluoroscopy time and the incidence of technical complications. However, within the subgroup of flow-disruptor cases, centers with lower case load exhibited significantly higher rates of hemorrhagic and clinically relevant complications. Additionally, it was noted that the rate of therapeutic success in the flow-diverter group significantly increased in centers with higher case volumes.ConclusionOur findings support the intention towards centralization of medical care especially for complex neuroendovascular procedures. Furthermore, our findings are an argument to further develop a standardized educational and procedural algorithm based on defined case numbers and training modules for complex neurovascular procedures as already implemented by the Database of the German Society for Interventional Radiology.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"1464-1469"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569760/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140868656","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Shuhai Long, Shuailong Shi, Zhike Zhang, Qi Tian, Zhuangzhuang Wei, Ji Ma, Ye Wang, Jie Yang, Xinwei Han, Tengfei Li
{"title":"A clinical comparative study of dual LVIS devices and single flow diversion stenting for the treatment of unruptured V3-V4 vertebral artery dissection.","authors":"Shuhai Long, Shuailong Shi, Zhike Zhang, Qi Tian, Zhuangzhuang Wei, Ji Ma, Ye Wang, Jie Yang, Xinwei Han, Tengfei Li","doi":"10.1177/15910199241254864","DOIUrl":"10.1177/15910199241254864","url":null,"abstract":"<p><p>PurposeThis study aims to compare the efficacy and safety of using overlapping low-profile visualized intraluminal support (LVIS) devices and flow diversion (FD) for the treatment of unruptured vertebral artery dissection (VAD) in the V3-V4 segments.MethodsThe clinical and imaging data of 71 patients with unruptured VAD in the V3-V4 segments who underwent either dual LVIS stenting (d-LVIS group) or single FD stenting (FD group) at our center from September 2014 to December 2021 were retrospectively analyzed.ResultsImmediate postoperative angiography revealed no significant difference in the degree of occlusion between the two groups in treating vertebral artery dissecting aneurysms (with or without noncompact coiling). However, the d-LVIS group had significantly higher fluoroscopy exposure time and total radiation exposure dose compared to the FD group. During the perioperative period, two cases of pontine infarction and one case of acute thrombosis were encountered. One patient died from subarachnoid hemorrhage during the follow-up period. For dissecting the aneurysm, angiographic follow-up (8.56 ± 1.96 months) showed similar healing outcomes between the two groups (with or without noncompact coiling). However, seven patients (7/40, 17.5%) showed poor healing and one patient showed mild in-stent stenosis. For simple dissection, angiographic follow-up (8.78 ± 1.83 months) showed patent lumens in both groups, with all dissections healing well, and two patients having mild in-stent stenosis.ConclusionBoth methods could effectively treat unruptured VAD in V3-V4 segments. Nevertheless, simple FD implantation is relatively easier to perform and involves lower radiation exposure.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"1502-1509"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569745/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140946313","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"\"Ghost Infarct Core\" and diffusion-weighted imaging.","authors":"Ezgi Yilmaz, Ethem M Arsava, Mehmet A Topcuoglu","doi":"10.1177/15910199241254558","DOIUrl":"10.1177/15910199241254558","url":null,"abstract":"","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"2034-2035"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569725/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140946312","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Rami Z Morsi, Sonam Thind, Archit Baskaran, Rohini Rana, Julián Carrión-Penagos, Harsh Desai, Sachin A Kothari, Ahmad Chahine, Jehad Zakaria, Sean P Polster, James E Siegler, Scott J Mendelson, Ali Mansour, Michael C Hurley, Shyam Prabhakaran, Tareq Kass-Hout
{"title":"Early single-center experience with middle meningeal artery embolization using Zoom<sup>™</sup> 45 Catheter.","authors":"Rami Z Morsi, Sonam Thind, Archit Baskaran, Rohini Rana, Julián Carrión-Penagos, Harsh Desai, Sachin A Kothari, Ahmad Chahine, Jehad Zakaria, Sean P Polster, James E Siegler, Scott J Mendelson, Ali Mansour, Michael C Hurley, Shyam Prabhakaran, Tareq Kass-Hout","doi":"10.1177/15910199241250078","DOIUrl":"10.1177/15910199241250078","url":null,"abstract":"<p><p>BackgroundMiddle meningeal artery (MMA) embolization for subdural hematomas (SDH) and dural arteriovenous fistulas (dAVFs) has gained momentum in the neuroendovascular space. However, there is variability in the technique for safe and effective embolization. The aim of this report is to describe the technical feasibility and clinical performance of using Zoom<sup>™</sup> 45 catheter for MMA access to facilitate embolization.MethodsWe analyzed all cases of MMA embolization in which the Zoom<sup>™</sup> 45 catheter was used and performed in our institution from February 2021 to March 2023 for SDH and dAVFs.ResultsA total of 32 patients were included. Mean age was 64.0 ± 18.0 years, 75.0% (4/32) were male, and 56.7% (17/30), were black. The technical success was achieved in 93.8% (30/32) of cases, with selective embolization utilizing microcatheter directly into frontal and parietal branches for most patients (96.9%, 31/32). Identification of dangerous collaterals, such as lacrimal and petrous branches, prior to embolization, was achieved in most patients (96.9%, 31/32). Bilateral MMA embolization was done in 50.0% (16/32) of patients. The transradial approach and transfemoral approach were used in 53.1% (17/32) and 46.9% (15/32) of patients, respectively. The most common embolization material was n-butyl cyanoacrylate (84.4%, 27/32). There were no access site complications or complications related to the MMA embolization procedures and used devices.ConclusionsThe use of Zoom<sup>™</sup> 45 Catheter seems to be technically feasible, safe, and effective for facilitating MMA access for embolization in the context of SDH and dAVFs.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"1523-1530"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11577324/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140872094","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Anzhela D Moskalik, Buqing Liang, Branden J Cord, Ben Waldau
{"title":"A technical guide to robotic-assisted carotid angioplasty and stenting with the Corindus CorPath GRX system.","authors":"Anzhela D Moskalik, Buqing Liang, Branden J Cord, Ben Waldau","doi":"10.1177/15910199241226856","DOIUrl":"10.1177/15910199241226856","url":null,"abstract":"<p><p>Robotic-assisted carotid artery angioplasty and stenting is becoming more popular due to its precision and radiation safety. In this video, we present a case using the CorPath GRX Robotic System (Corindus, a Seimens Healthineers Company, Waltham, Massachusetts, USA) with step-by-step procedure process and technical nuances (video 1). We demonstrate that cervical carotid angioplasty and stenting can be safely performed using the robotic system with efficiency and accuracy.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"2066"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11579842/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139486631","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Santiago Gomez-Paz, Patrick King, Alwyn Gomez, Ramesh Grandhi
{"title":"Exploring robotic advances, applications, and challenges in neuroendovascular surgery: A scoping review of the CorPath GRX system.","authors":"Santiago Gomez-Paz, Patrick King, Alwyn Gomez, Ramesh Grandhi","doi":"10.1177/15910199241305691","DOIUrl":"10.1177/15910199241305691","url":null,"abstract":"<p><p>BackgroundThe integration of robotics into neuroendovascular surgery has the potential to revolutionize the field by enhancing precision, reducing procedure-related risks, and improving patient outcomes. The CorPath GRX system represents a significant advancement in this domain. In this systematically conducted scoping review, we explore the current applications, advances, and challenges associated with robot-assisted neuroendovascular surgery.MethodsA comprehensive literature search was conducted across PubMed, Scopus, Embase, and Web of Science, covering publications from January 2015 to December 2024. Relevant data were extracted from studies involving human subjects and reporting the use of robotic guidance with the CorPath GRX system for neuroendovascular procedures for review and discussion.ResultsWe identified 14 studies with a total of 336 patients who underwent robot-assisted neuroendovascular procedures, including both diagnostic (48.2%) and therapeutic (51.8%) applications. Among the therapeutic interventions, 140 patients were treated for hemorrhagic pathology, including 128 procedures for unruptured intracranial aneurysms and 12 for ruptured aneurysms. These procedures primarily involved stent-assisted coiling or flow diversion therapy. Additionally, 34 patients were treated for ischemic pathology, primarily carotid artery stenosis, involving balloon angioplasty and stent placement. A tumor was addressed in 1 intervention via coil embolization of tumor feeders, showcasing the versatility of robot-assisted interventions. Technical success rates were high across the studies, with most procedures achieving 100% success. Manual conversions were for device malfunctions or anatomical challenges. Complications reports varied, with some studies detailing specific device malfunctions and others providing less specific accounts.ConclusionsOverall, the CorPath GRX system demonstrated high feasibility and safety for neuroendovascular procedures, indicating significant potential benefits, particularly if integrated into telemedicine practices. The CorPath GRX system shows promise in facilitating precise and safe neuroendovascular procedures. Current evidence highlights a wide range of benefits; however, further research is needed to investigate long-term outcomes and other potential areas of impact.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"1815-1821"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11662343/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142873100","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Middle meningeal artery embolization for the treatment of unilateral large chronic subdural hematoma patients with significant midline shift: A single-center experience.","authors":"Yin Niu, Qiang Zhang, Zhouyang Jiang, Wenyan Li, Zhi Chen","doi":"10.1177/15910199241239706","DOIUrl":"10.1177/15910199241239706","url":null,"abstract":"<p><p>BackgroundThe amount of midline shift (MLS) considered safe for middle meningeal artery embolization (MMAE) in patients with chronic subdural hematoma (CSDH) has not been established. Whether MMAE could be used as upfront treatment for unilateral large CSDH patients with significant MLS (>1 cm) has not been reported.ObjectiveTo investigate the efficacy and safety of MMAE in unilateral large CSDH patients with MLS > 1 cm.MethodsEleven carefully selected CSDH patients with mild or moderate symptoms and significant MLS > 1 cm from 1 May 2021 to 31 August 2022 were included in the study. All patients were treated with MMAE using polyvinyl alcohol (PVA) particles. Outcomes were assessed clinically and with interval imaging studies at follow-up.ResultsAll 19 MMAs (unilateral embolization in three patients and bilateral embolization in eight patients) were successfully embolized. All 11 patients were followed for subsequent months, and there was no recurrence and enlargement of CSDH. Procedural adverse events, mortality, or complications were not observed. The average time to achieve a 50% reduction in MLS was approximately four weeks, while it took approximately eight weeks to achieve a 50% reduction in maximal volume. All 11 patients showed improvement in their neurological symptoms at three days post-operation, including four hemiplegic patients.ConclusionsMMAE may demonstrate safety in carefully selected CSDH patients with significant midline shift (MLS > 1 cm), particularly in those who are not suitable for surgery, thus providing a potential alternative approach.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"1322-1328"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11571913/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140186099","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Reza Seiffert, Olivier Brina, Philippe Reymond, Jeremy Hofmeister, Gianmarco Bernava, Andrea Rosi, Lars Michels, Zsolt Kulcsar, Karl-Olof Lovblad, Paolo Machi
{"title":"Experimental comparison of first-pass effect between direct thromboaspiration and combined thrombectomy in the setting of distal basilar occlusion.","authors":"Reza Seiffert, Olivier Brina, Philippe Reymond, Jeremy Hofmeister, Gianmarco Bernava, Andrea Rosi, Lars Michels, Zsolt Kulcsar, Karl-Olof Lovblad, Paolo Machi","doi":"10.1177/15910199241254412","DOIUrl":"10.1177/15910199241254412","url":null,"abstract":"<p><p>BackgroundStudies investigating endovascular therapy in vertebro-basilar stroke have led to controversial results in the past, but recent randomized trials seem to show an effectiveness superiority of endovascular therapy versus best medical treatment. However, uncertainty remains concerning many aspects of thrombectomy in acute basilar artery occlusion, notably technical considerations. This study compared the first-pass effect of direct thromboaspiration and combined thrombectomy in the setting of distal basilar occlusion.MethodsAn in-vitro experimental set-up was used, consisting of a vascular phantom model and thrombus analogs of different consistencies to mimic human clots. Thrombus analogs were injected into the model through the vertebral artery and flowed to the basilar distal third to mimic a distal basilar occlusion. Ten procedures were performed for each thrombus analog stiffness and technique (direct thromboaspiration versus combined thrombectomy).ResultsDirect thromboaspiration showed an overall first-pass effect rate of 83.3% (25/30) and was particularly effective for ultra-soft and soft clot analogs, but decreased for hard clot analogs. Combined thrombectomy had an overall first-pass effect rate of 56.7% (17/30). The effect rate for ultra-soft and soft clot analogs was 60% and 50% for hard clot analogs. In the softer clot analogs, the stent-retriever device used for the combined thrombectomies tended to deviate the clot analog from a co-axial trajectory with the aspiration catheter.ConclusionsIn the context of distal basilar occlusion, our in-vitro results showed that higher first-pass effect rates were achieved with direct thromboaspiration compared to combined thrombectomy in all types of thrombus analogs.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"1485-1490"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569773/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140946354","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Shyle H Mehta, Timothy G White, Kevin A Shah, Daniel G Lynch, Cassidy D Werner, Ina Teron, Thomas Link, Athos Patsalides, Henry H Woo
{"title":"Single-center outcomes of Onyx Frontier™ and Resolute Onyx™ drug-eluting balloon-mounted stents for rescue stenting for acute large vessel occlusion.","authors":"Shyle H Mehta, Timothy G White, Kevin A Shah, Daniel G Lynch, Cassidy D Werner, Ina Teron, Thomas Link, Athos Patsalides, Henry H Woo","doi":"10.1177/15910199231226285","DOIUrl":"10.1177/15910199231226285","url":null,"abstract":"<p><p>BackgroundIn cases where mechanical thrombectomy (MT) fails, rescue stenting may be necessary to achieve reperfusion; however, the lack of standardized techniques or devices poses a challenge. This series aims to present our early experience with the Onyx Frontier™ and Resolute Onyx™ balloon-mounted drug-eluting stents for rescue stenting.MethodsA retrospective chart review was performed of all patients who underwent rescue stenting, in the setting of failed MT, using Onyx Frontier™ or Resolute Onyx™ stents at a single institution. Technical details, procedural complications, and patient outcomes were recorded for each case.ResultsTwenty-two Onyx Frontier™ and Resolute Onyx™ stents were deployed in 18 patients undergoing rescue stenting. Stent locations included the middle cerebral artery (36.4%), internal carotid artery (18.2%), vertebral artery (22.7%), and basilar artery (22.7%). The average National Institutes of Health Stroke Scale score before MT was 13.8 (range 0-31). The median initial modified Rankin Scale (mRS) score was zero, while the median mRS score at follow-up was three. Successful reperfusion, as assessed by TICI scores, was achieved in 43.8% of patients for TICI 3, 43.8% for TICI 2C, and 12.5% for TICI 2B. Post-revascularization, 16.7% of patients experienced hemorrhage, of which one patient (5.6%) had symptomatic hemorrhage.ConclusionsOnyx Frontier™ and Resolute Onyx™ stents are well suited for rescue stenting in cases of failed MT. These balloon-mounted drug-eluting stents exhibit excellent navigability, rendering them appropriate for rescue revascularization procedures. Our findings demonstrate that these stents confer a high degree of technical success.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"1875-1880"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569801/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139486639","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Arsida Bajrami, Songul Senadim, Demet Funda Bas, Eren Erdem, Serdar Geyik
{"title":"Mechanical thrombectomy with Embolus Retriever with Interlinked Cages device for medium vessel occlusions: First pass results and safety profile.","authors":"Arsida Bajrami, Songul Senadim, Demet Funda Bas, Eren Erdem, Serdar Geyik","doi":"10.1177/15910199241254409","DOIUrl":"10.1177/15910199241254409","url":null,"abstract":"<p><p>BackgroundReperfusion of medium vessel occlusions is correlated with good outcomes. However, optimal techniques and medical devices are still unclear. In this study, we sought to evaluate the safety and efficacy of mechanical thrombectomy with Embolus Retriever with Interlinked Cages (ERIC™) retrieval device in patients with acute ischemic stroke due to distal medium vessel occlusions.MethodsA retrospective review of the prospectively collected mechanical thrombectomy database revealed 50 patients who had fulfilled the inclusion criteria. The data collected includes clinical patient characteristics, procedural measures, timestamps at each stage, and patient outcomes. Intravenous thrombolytics application, pre- and post-intervention imaging findings, device-related adverse events and any type of intracranial hemorrhage were recorded.ResultsThere were 25 men (50%) and 25 women (50%) with a median of 67 years (interquartile range (IQR) 41-84). Median presenting NIHSS was 14 (IQR, 3-23). First pass rates were: eTICI3 in 16 cases (32%), eTICI-2c in eight cases (16%), eTICI-2B67 in nine cases (10%), eTICI2B50 in three cases (6%) and mTICI 0-2A in 18 cases (36%). Final recanalization rate of mTICI 2b-3 was 90% and 2c-3 was 70%.ConclusionIn conclusion, the ERIC thrombectomy device offers a high rate of first-pass success along with a favorable safety profile. Larger series and multi-center studies are needed for further investigation.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"1498-1501"},"PeriodicalIF":1.9,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11571576/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141077043","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}