虚拟模拟用于颅内动脉瘤血管内治疗中分流器的选择和大小:系统回顾和荟萃分析。

IF 1.5 4区 医学 Q4 CLINICAL NEUROLOGY
Christian Ferreira, Marcio Yuri Ferreira, Raphael Bertani, Lucca Biolcati Palavani, Pedro Glb Borges, Ahmet Günkan, Gean Carlo Müller, Henrique Garcia Maia, Gabriel Semione, Savio Batista, Henrique Laurent Lepine, Daniel Zumofen, Katherine Stark, Ricardo A Hanel, David Gordon, Yafell Serulle, David Langer
{"title":"虚拟模拟用于颅内动脉瘤血管内治疗中分流器的选择和大小:系统回顾和荟萃分析。","authors":"Christian Ferreira, Marcio Yuri Ferreira, Raphael Bertani, Lucca Biolcati Palavani, Pedro Glb Borges, Ahmet Günkan, Gean Carlo Müller, Henrique Garcia Maia, Gabriel Semione, Savio Batista, Henrique Laurent Lepine, Daniel Zumofen, Katherine Stark, Ricardo A Hanel, David Gordon, Yafell Serulle, David Langer","doi":"10.1177/15910199251323006","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Endovascular treatment (EVT) of intracranial aneurysms (IAs) has improved significantly with the integration of virtual simulation software (VSS) in surgical planning and device selection. Despite promising outcomes, discrepancies remain between physician and VSS recommendations. This review synthesizes evidence on (1) comparisons between VSS-chosen and physician-chosen dimensions; (2) VSS-chosen and postoperative measured dimensions; and (3) the success rate of VSS-guided device deployment.</p><p><strong>Methods: </strong>A systematic search adhering to PRISMA guidelines was conducted in Medline, Embase, Web of Science, and Cochrane databases up to January 2024. Eligible studies included case series, cohort studies, and randomized trials assessing VSS for stent selection in IAs treatment. Mean difference (MD) and single-arm meta-analysis with 95% confidence intervals (CIs) under a random-effects model were performed for continuous and binary outcomes. Subanalyses were conducted for Sim&Size and PreSize software.</p><p><strong>Results: </strong>Ten studies comprising 658 IAs were included. Pipeline Embolization Device was most commonly used. Findings demonstrated (1) high accuracy of VSS when comparing simulated and postoperative lengths (MD -1.7 mm; 95% CI -4.37 to 0.98 mm); (2) physician-chosen lengths overestimated compared to VSS (MD -2.11 mm; -3.43 to -0.79 mm); (3) no significant difference in physician- versus VSS-chosen diameters (MD -0.04 mm; -0.13 to 0.06 mm); and (4) high VSS-guided deployment success (96%; 93-99%) with low complications (4%). Subanalyses showed 95% and 92% deployment success rates for Sim&Size and PreSize, respectively.</p><p><strong>Conclusion: </strong>VSS effectively estimates device length and achieves high deployment success, with low complication rates, supporting its utility in EVT planning.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199251323006"},"PeriodicalIF":1.5000,"publicationDate":"2025-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11873847/pdf/","citationCount":"0","resultStr":"{\"title\":\"Virtual simulation for flow-diverter selection and sizing in the endovascular treatment of intracranial aneurysms: A systematic review and meta-analysis.\",\"authors\":\"Christian Ferreira, Marcio Yuri Ferreira, Raphael Bertani, Lucca Biolcati Palavani, Pedro Glb Borges, Ahmet Günkan, Gean Carlo Müller, Henrique Garcia Maia, Gabriel Semione, Savio Batista, Henrique Laurent Lepine, Daniel Zumofen, Katherine Stark, Ricardo A Hanel, David Gordon, Yafell Serulle, David Langer\",\"doi\":\"10.1177/15910199251323006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Endovascular treatment (EVT) of intracranial aneurysms (IAs) has improved significantly with the integration of virtual simulation software (VSS) in surgical planning and device selection. Despite promising outcomes, discrepancies remain between physician and VSS recommendations. This review synthesizes evidence on (1) comparisons between VSS-chosen and physician-chosen dimensions; (2) VSS-chosen and postoperative measured dimensions; and (3) the success rate of VSS-guided device deployment.</p><p><strong>Methods: </strong>A systematic search adhering to PRISMA guidelines was conducted in Medline, Embase, Web of Science, and Cochrane databases up to January 2024. Eligible studies included case series, cohort studies, and randomized trials assessing VSS for stent selection in IAs treatment. Mean difference (MD) and single-arm meta-analysis with 95% confidence intervals (CIs) under a random-effects model were performed for continuous and binary outcomes. Subanalyses were conducted for Sim&Size and PreSize software.</p><p><strong>Results: </strong>Ten studies comprising 658 IAs were included. Pipeline Embolization Device was most commonly used. Findings demonstrated (1) high accuracy of VSS when comparing simulated and postoperative lengths (MD -1.7 mm; 95% CI -4.37 to 0.98 mm); (2) physician-chosen lengths overestimated compared to VSS (MD -2.11 mm; -3.43 to -0.79 mm); (3) no significant difference in physician- versus VSS-chosen diameters (MD -0.04 mm; -0.13 to 0.06 mm); and (4) high VSS-guided deployment success (96%; 93-99%) with low complications (4%). Subanalyses showed 95% and 92% deployment success rates for Sim&Size and PreSize, respectively.</p><p><strong>Conclusion: </strong>VSS effectively estimates device length and achieves high deployment success, with low complication rates, supporting its utility in EVT planning.</p>\",\"PeriodicalId\":49174,\"journal\":{\"name\":\"Interventional Neuroradiology\",\"volume\":\" \",\"pages\":\"15910199251323006\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-03-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11873847/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15910199251323006\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199251323006","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Virtual simulation for flow-diverter selection and sizing in the endovascular treatment of intracranial aneurysms: A systematic review and meta-analysis.

Background: Endovascular treatment (EVT) of intracranial aneurysms (IAs) has improved significantly with the integration of virtual simulation software (VSS) in surgical planning and device selection. Despite promising outcomes, discrepancies remain between physician and VSS recommendations. This review synthesizes evidence on (1) comparisons between VSS-chosen and physician-chosen dimensions; (2) VSS-chosen and postoperative measured dimensions; and (3) the success rate of VSS-guided device deployment.

Methods: A systematic search adhering to PRISMA guidelines was conducted in Medline, Embase, Web of Science, and Cochrane databases up to January 2024. Eligible studies included case series, cohort studies, and randomized trials assessing VSS for stent selection in IAs treatment. Mean difference (MD) and single-arm meta-analysis with 95% confidence intervals (CIs) under a random-effects model were performed for continuous and binary outcomes. Subanalyses were conducted for Sim&Size and PreSize software.

Results: Ten studies comprising 658 IAs were included. Pipeline Embolization Device was most commonly used. Findings demonstrated (1) high accuracy of VSS when comparing simulated and postoperative lengths (MD -1.7 mm; 95% CI -4.37 to 0.98 mm); (2) physician-chosen lengths overestimated compared to VSS (MD -2.11 mm; -3.43 to -0.79 mm); (3) no significant difference in physician- versus VSS-chosen diameters (MD -0.04 mm; -0.13 to 0.06 mm); and (4) high VSS-guided deployment success (96%; 93-99%) with low complications (4%). Subanalyses showed 95% and 92% deployment success rates for Sim&Size and PreSize, respectively.

Conclusion: VSS effectively estimates device length and achieves high deployment success, with low complication rates, supporting its utility in EVT planning.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Interventional Neuroradiology
Interventional Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
3.60
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信