{"title":"Protection relay stability study for 115kV and 34.5kV transmission and distribution system","authors":"Sin-Jo Jung, I. Kang","doi":"10.1109/APAP.2011.6180533","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180533","url":null,"abstract":"Some clients request the stability study of a protection system in designing power system to evaluate whether protection relays properly operate in case of an internal fault and if they do not function in the events of severe external fault. High fault currents could cause Current Transformers (CTs) to be saturated. A critical concern is the performance of fast protective relay (instantaneous or differential elements) during severe saturation of CTs. Time domain transient simulation software is widely used for the study of these types of works. In this paper, a relay stability study of 115 kV and 34.5 kV transmission and distribution systems was carried out and evaluated utilizing the PSCAD software, which provides several modeling methodologies for various electrical equipment such as transmission line, power transformer, current transformer and protective relays. For the purpose of this study, the modeling method of CT is the most important factor because it influences heavily on the protection relay operation. It is very important to model CT as close as the real characteristics of the CT. Two types of CT models provided by the PSCAD were discussed and compared with each other and an appropriate CT modeling methods were covered in this study. This study is mainly based on digital relays, which prevail recently in the relay market. Digital relay characteristics like anti-aliasing filter, digital filter and various setting function are embedded into PSCAD.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125590419","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The analysis and corrective measures of common problems of 10 kV capacitor bank in substation","authors":"JingBin Lian, Huaizhu Li, KangQun Song","doi":"10.1109/APAP.2011.6180835","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180835","url":null,"abstract":"In this paper, based on instances in substation, the common problems in the management of capacitor bank were analyzed. Moreover, the standard painting method of capacitor bank, the operation procedures and the safety measures of capacitor bank in substation was discussed. The solution to address these problems was proposed, which could provide a theoretical basis for the capacitor bank maintenance and the painting of electric primary system diagram in substation.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127874864","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A new Improvement Strategy based on hysteresis space vector control of Grid-connected inverter","authors":"Xiaoju Chen, Hang Zhang, Jian Zhao","doi":"10.1109/APAP.2011.6180755","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180755","url":null,"abstract":"As a type of renewable energy, photovoltaic system has attracted increasingly great attention recently for its simple topology, control strategy and high efficiency. Grid-connected current control strategy, a key point of photovoltaic system, also becomes a hot research.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"104 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127901120","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
YongHwan Jo, Taewan Kim, Myeon-Song Choi, Seungjae Lee
{"title":"A design of Database Configurator for IEC 61850 client","authors":"YongHwan Jo, Taewan Kim, Myeon-Song Choi, Seungjae Lee","doi":"10.1109/APAP.2011.6180486","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180486","url":null,"abstract":"Major features of IEC 61850 include SCL-based engineering, uniform data model and communication-based information transfer. Owing to XML-based characteristics of SCL, a substation engineering can be done easily with programming. There are four kinds of information file in the SCL-based engineering - SSD (System Specification Description), ICD (IED Capability Description), CID (Configured IED Description) and SCD (Substation Configuration Description). The SCD file has all information about substation configuration. From SCD file, data or information of interest can be easily extracted using SCL parser and they can be stored in the database automatically.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128179595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research on technical framework of smart distribution network","authors":"Jianfang Li, Xiaoli Meng, Xiaohui Song","doi":"10.1109/APAP.2011.6180528","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180528","url":null,"abstract":"The future development trend of electric power grid is smart grid, which include such features as flexible, clean, secure, economic, and friendly and so on. Smart grid involves power generation, transmission, transformation, distribution, consumption and dispatching. Distribution network locates at the end of power system, and due to its direct connection with consumers, the quality and ability of power supply is guaranteed by it. In this paper, the connotation, characteristics and the development goals of smart distribution network in China are expounded firstly. Secondly, the technical framework of smart distribution network, which include network infrastructure, information communication system and intelligent application system, is put forward. The main technical compositions of the framework are briefly discussed in succession. Lastly, the suggestion on development path of smart distribution network in china is proposed, in the hope of providing reference to the further research and implementation of smart distribution network.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"275 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132074281","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigation of multi-inverter distributed generation resident Sandia frequency shift anti-islanding method","authors":"Wen-bin Han, T. Zheng, Xiaoyu Wang","doi":"10.1109/APAP.2011.6180726","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180726","url":null,"abstract":"With the popularity of the distributed generation (DG), grid-connected inverters are increasingly employed for the renewable energy sources utilization. The inverter is an interface between the power system and the micro-grid, and it is equipped with a variety of inverter control strategies and islanding detection scheme. Islanding detection function is an integrant function for grid-connected inverters. The current studies focus on single-inverter system, while the islanding detection strategies in multi-inverters operation are investigated in this paper. From the perspective of multi-inverter systems, this paper investigates the influence of the positive feedback anti-islanding on the stability. First, the analytical model of multi-inverter systems equipped with the positive feedback anti-islanding scheme is set up in the simulation environment of Matlab/Simulink. Second, the scheme's impact on the multi-inverter systems is conducted to obtain the nature and characteristics, and the interactions among multi DGs caused by the scheme are presented in the paper. Third, based on the electromagnetic transient simulations, the above impacts and interactions are verified further. Finally, the conclusions are given out based on the analysis results.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132339294","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Man Zhang, Jinghong Zheng, Wenzhuo Wang, Mengting Dai
{"title":"Research on static voltage stability based on EV charging station load modeling","authors":"Man Zhang, Jinghong Zheng, Wenzhuo Wang, Mengting Dai","doi":"10.1109/APAP.2011.6180969","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180969","url":null,"abstract":"With more and more EV charging stations accessed to power system, researches on the clustering effect of EV chargers and their influence on the static voltage stability become important and necessary. This paper carries out studies aiming at analysis, modeling and simulation of EV charging station along with its impacts on the static voltage stability of power system. In this paper, the load characteristics of EV charger are deduced separately in the constant-current/constant-voltage charging mode. Then the single EV charger model and the cluster equivalent load model of an EV charging station is established in Matlab/Simulink toolbox, after which its impact on the static voltage stability is studied based on a simple system through simulation.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"569 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134236804","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A real time PMU data and neural network approach to analyze voltage stability","authors":"H. Innah, T. Hiyama","doi":"10.1109/APAP.2011.6180572","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180572","url":null,"abstract":"This paper proposes a Voltage Stability assessment of Power System in real time operation using Radial Basis Function Neural Network (RBF NN). One of the methods which widely used for assessing Voltage Stability is Index Stability (L-index). The indicator obtained from fundamental Kirchhoff Law which is simple in numerical calculation for steady state flow analysis. Input parameters for index calculation taken from real time measurement in the system which provides faster Recently, Phasor Measurement Units (PMUs) is a advanced method to get the information of system parameter in the wide operation with high rate data. Due to the uneconomical reason and unnecessary to place one bus for one PMU, therefore optimization placement has been applied. However, the selection of PMUs locations can be seen as a reduction of input parameters, which require for index stability calculation. To solve the lack of input parameter problem, a trained data of RBF NN has used to predict index stability. This study using 14 bus IEEE system to test the propose method and the result presents the performance of the network is sufficient to predict the index stability.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"160 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132971137","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Comparative analysis on critical clearing time of power system connected with large wind farm","authors":"Zhiwei Wen, Shi-en He","doi":"10.1109/APAP.2011.6180391","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180391","url":null,"abstract":"The analysis of transient stability of power system connected with large wind farm is an important issue in the planning and operation of wind farm because the reactive power variation and the real power variation of wind farm interconnected with power grid leads to voltage fluctuation and frequency fluctuation of power grid. Impact of large scale wind farm integration on electric power system, effect on electric power system produced by development of wind power in a local grid typically in China has been represented. Based on electromagnetic transient software DIgSILENT/PowerFactory, the interconnected wind farm model and VSC-HVDC model as well as HVAC and HVDC model are set up. Comparative analysis of post-fault transient performance of wind turbines with different type of tie-line has been proposed. As a character of transient stability of power system, critical clearing time of three-phase short-circuit fault is studied in this paper. The digital simulation results show that VSC-HVDC is a better measure to solve the problems of system instability due to large wind farm integration. With VSC-HVDC transmission system, the transient stability of system can be improved better by flexible operation and control. Analysis of this paper should be provided as academic reference for improving design of interconnected wind farm system.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129381896","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jie Zhou, Daonong Zhang, Yue-hai Yu, Jingtao Wu, Ji Zhou, T. Bi, Ming Xiong
{"title":"Rotor position measurement method for generator power angles","authors":"Jie Zhou, Daonong Zhang, Yue-hai Yu, Jingtao Wu, Ji Zhou, T. Bi, Ming Xiong","doi":"10.1109/APAP.2011.6180792","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180792","url":null,"abstract":"In traditional engineering applications, the internal voltage and power angle of generators are often measured by the electrical calculation method. The internal voltage and power angle of generators are calculated by direct-axis reactance Xd, quadrature-axis reactance Xq, terminal voltage and current which measured real-time. This calculation method may result in deviation because the value of Xd and Xq may be changed when the generator running in different status. This paper proposes a kind of rotor position measurement method. The internal voltage and power angle of generators are gotten by using generator phase keying signal and terminal voltages. This method is independent of generator equivalent calculative models and the value of synchronous reactance. It has high accuracy and suitable for real-time power angle measurement when power grid is in a disturbing or transient processing.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130963850","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}