{"title":"New theory of directional current protection for the distribution network containing DG based on fault component","authors":"Shu Tian, Y. Liu, Guangyong Mei","doi":"10.1109/APAP.2011.6180368","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180368","url":null,"abstract":"The distribution network will be changed from the single power to the multi-power supplied when DG combined into it. Three-section current protections will no longer be applicable. Therefore, a new protection scheme which is suitable for the distribution network contained DG be proposed, which is that the protections lying on the downstream lines of DG need to have new setting value, and the protections with the directional components need to be installed on the line between the power and DG. Based on the qualitative analysis of the influence of DG combined into the network on the traditional current protection of distribution network, this paper proposed a new directional current protection on the basis of the positive- sequence fault component. The scheme using fault component principle analyzed the phase angle difference of the positive- sequence current in one period just before the fault and that just after the fault, worked out the protection criterion of the positive and negative fault, and thereby realized the fault location.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"87 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132889740","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Observation on bus voltage angles through power flow computation for 2010 summer peak of South Korea","authors":"SangJoong Lee, Woon-Hee Lee","doi":"10.1109/APAP.2011.6180706","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180706","url":null,"abstract":"In this paper, some results of power flow computation for 2010 summer peak of South Korea are presented following introduction of the Korea power network composed of 154kV, 345kV and 765kV transmission lines. They include: - total MW on 2010 summer peak time - MW demands of major load buses - MW outputs of major generators - bus voltages of significant buses. Bus angles and the angle differences between buses are important for the study of power flow, stability, protective relaying, etc. This paper shows the magnitude of voltage angles for some meaningful buses. Magnitudes of the real and imaginary part of the complex voltage angles of the buses are compared. The spread angle of the network is also observed.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132088058","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Honglei Yang, W. Sheng, Jinyu Wang, Jinli Wang, Q. Song
{"title":"The typical construction mode research of intelligent distribution network","authors":"Honglei Yang, W. Sheng, Jinyu Wang, Jinli Wang, Q. Song","doi":"10.1109/APAP.2011.6180628","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180628","url":null,"abstract":"This paper introduced the conception and features of smart grid as well as analyzed research progress at home and abroad. The intelligent application in the field of power distribution was still in research and exploration phase. From information collecting, intelligent distribution transformer and distribution automation, intelligent distribution network construction idea and construction mode were proposed in this paper. Accordance with the State Grid Corporation of the “three sets five” management requirement, a real-time comprehensive data collection monitoring system was built which formatted a integrated distribution network data center in county power supply company, in order to provide technical support for great marketing system. With “SG186” engineering, a integrated enterprise information management system was built, which formatted a non-real-time systems integration data center, in order to achieve the application system data integration for enterprise production and management. From the research and application of infrastructure project and key technology, the county's automated distribution network and information level were gradually increased, which provided the basis of the county intelligent distribution network construction in the future.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"40 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131012865","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The comparison and analysis of lumped parameter equivalent circuits of transmission line","authors":"Shicong Ma, Jianbo Guo, Huadong Sun, Yongjin Yu","doi":"10.1109/APAP.2011.6180565","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180565","url":null,"abstract":"Based on the frequency characteristics analysis, the feature and scope of lumped parameters circuits are presented in this paper, which can be as the reference of equivalent circuit selection. Firstly the Γ section equivacircuit was introduced as the equivalent of transmission line and its validity was proved. The frequency characteristics of lumped parameters circuits are analyzed and compared with the distributed parameters circuit. From characteristic analysis, the effective frequency band that the lumped parameters circuit can be taken as the equivalent of transmission line was obtained. Considering effective frequency band and model complexity, the selection pinciple for application is proposed. The research results showed that Γ section has the best approximation and Γ section has the simplest model equation. The proper selection of equivalent circuit can significantly increase the convenience and effectiveness for power system calculation.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130256474","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Lijun Qin, Meng Li, Ying Wang, Cuijuan Hao, Huawei Jin
{"title":"CIM-based three-phase state estimation of distribution network","authors":"Lijun Qin, Meng Li, Ying Wang, Cuijuan Hao, Huawei Jin","doi":"10.1109/APAP.2011.6180483","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180483","url":null,"abstract":"CIM model provides a logical view of the physical aspects of distribution management system (DMS) information. This paper firstly presents the characteristic about CIM model used for state estimation of distribution system. Secondly, a brief introduction about the basic characteristics and requirements of three-phase state estimation of distribution system is given. Thirdly, this paper focuses on the branch current-based three-phase state estimation algorithm of distribution network, which selects the amplitude and phase of branch current as state variables. As the algorithm not only greatly simplifies the Jacobian matrix to facilitate iterative calculation, but also achieves three-phase together with real and imaginary parts decoupling to make use of a variety of measurements effectively and simply. Finally, the paper describes the design idea that how to implement the state estimation algorithm, and gives an algorithm flow chart to carry out the CIM-based three-phase state estimation of distribution network.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"7 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131672479","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Fault identification of transmission line using the union back-up information in regional-area","authors":"Chen Li, Zengping Wang, Xianguo Jiang, XueDi Fan","doi":"10.1109/APAP.2011.6180547","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180547","url":null,"abstract":"A back-up protection scheme based on the union back-up protection information for a transmission network is described in the paper. The scheme, referred to as the Back-up Protection Decision System (RBDS), is implemented by using three relevant matrixes SF, TF and DE, and three action factors α, β and γ. The RBDS provides optimal fault clearance for faults located anywhere on the protected network. To achieve an optimal response, the RBDS needs to know the topology of the network and the operating information of back-up relays. Based on this information, the Back-up Protection Decision System will try to identify the line which contains a fault. The relaying protection N-1 operation statuses are analyzed. The results of case studies show that this scheme based on the union back-up protection information is simple and convenient for fault determination, and the results are exact against N-1 operation statuses that can improve the performance of the back-up protection system.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123382192","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The application analysis of IEEE1588 in smart substation","authors":"BuFeng Liu, ZhiQiang Ji, Z. Xie","doi":"10.1109/APAP.2011.6180433","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180433","url":null,"abstract":"Time synchronization is the necessary technique to implement automation system in smart substations. It provides the accuracy time stamp mark used for data acquisition and used to analyze and deal with the power system fault. As a type of clock synchronization used in network with high precision, IEEE1588 is widespread applied recently in smart substations. This paper analyzes the reason of clock synchronization resulting in the deviation among devices, compares the different types of clock synchronization in present smart substations, describe the specific application of IEEE1588 in smart substations, and points out the matters need attention during the application of IEEE1588.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126455016","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Su-Geun Jang, Jung-wan Choi, SeungGuk Baek, J. Yun, Kwangho Kim
{"title":"Development of an integrated Condition Monitoring and Diagnosis system (IEC61850) for cubicle-GIS","authors":"Su-Geun Jang, Jung-wan Choi, SeungGuk Baek, J. Yun, Kwangho Kim","doi":"10.1109/APAP.2011.6180762","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180762","url":null,"abstract":"This paper describes an integrated CMD (Condition Monitoring & Diagnosis) system based on CBM (Condition Based Maintenance) for CGIS (Cubicle Gas Insulated Switchgear) to inspect the failure possibility of the electrical and mechanical components of CGIS in advance. The smart method monitors and diagnoses the condition of CGIS using UHF (Ultra High Frequency) antenna for partial discharge (moving particles, electrode protrusions, floating electrodes, void in solid insulation etc.), pressure sensor for leakage and burst out of tank, and coil current, and stroke sensor for VI (Vacuum Interrupter) trouble (contact abrasion, coil aging, motor dam-age, disoperation etc.). The proposed method can communicate with the smart grid in IEC61850 protocol. The logical nodes for condition monitoring and diagnosis of CGIS are shown. The intelligent monitoring and diagnosis method can prevent the failures of CGIS carrying the enormous blackout as well as the unnecessary displacement of the sound CGIS without damage.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"153 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121517336","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Zhou, Xingying Chen, Jian Liu, Xinzhou Dong, Ying-chen Liao
{"title":"Distribution network reconfiguration considering the random character of wind power generation","authors":"S. Zhou, Xingying Chen, Jian Liu, Xinzhou Dong, Ying-chen Liao","doi":"10.1109/APAP.2011.6180559","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180559","url":null,"abstract":"A chance constrained programming formulation for distribution reconfiguration with wind power generator (WPG) is proposed that aims at minimum power loss and increment voltage quality. A scenario analysis method is applied to describe the random output of WPG through the scenario probability and scenario output. A multiple objective particle algorithm (MOPSO) is employed to solve the multi-objective discrete nonlinear optimization problem. The dedicated particle encoding with the mesh information of the distribution network can effectively avoid producing a large amount of invalid solutions. With MOSPO, it is possible to obtain the optimum solution set of each objective while helping the operator to choose the most appropriate plan for reconfiguration. Application of the model and MOPSO algorithm to the 69 distribution network has verified their feasibility and correctness.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"209 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123037293","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Overview of multi-terminal VSC HVDC transmission for large offshore wind farms","authors":"G. Shi, Zhe Chen, X. Cai","doi":"10.1109/APAP.2011.6180584","DOIUrl":"https://doi.org/10.1109/APAP.2011.6180584","url":null,"abstract":"Future offshore wind farms will have large power ratings and will be situated much further offshore than current projects. An outstanding issue to be solved is long distance transmission of bulk, fluctuant and widely dispersed wind power to onshore AC grid. The objective of this paper is to explain why multi-terminal VSC HVDC is believed to be the most suitable transmission network for this offshore application, and present an overview of its key technologies state of the art and different obstacles that still exist at present.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"130 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123072609","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}