发电机功率角转子位置测量方法

Jie Zhou, Daonong Zhang, Yue-hai Yu, Jingtao Wu, Ji Zhou, T. Bi, Ming Xiong
{"title":"发电机功率角转子位置测量方法","authors":"Jie Zhou, Daonong Zhang, Yue-hai Yu, Jingtao Wu, Ji Zhou, T. Bi, Ming Xiong","doi":"10.1109/APAP.2011.6180792","DOIUrl":null,"url":null,"abstract":"In traditional engineering applications, the internal voltage and power angle of generators are often measured by the electrical calculation method. The internal voltage and power angle of generators are calculated by direct-axis reactance Xd, quadrature-axis reactance Xq, terminal voltage and current which measured real-time. This calculation method may result in deviation because the value of Xd and Xq may be changed when the generator running in different status. This paper proposes a kind of rotor position measurement method. The internal voltage and power angle of generators are gotten by using generator phase keying signal and terminal voltages. This method is independent of generator equivalent calculative models and the value of synchronous reactance. It has high accuracy and suitable for real-time power angle measurement when power grid is in a disturbing or transient processing.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Rotor position measurement method for generator power angles\",\"authors\":\"Jie Zhou, Daonong Zhang, Yue-hai Yu, Jingtao Wu, Ji Zhou, T. Bi, Ming Xiong\",\"doi\":\"10.1109/APAP.2011.6180792\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In traditional engineering applications, the internal voltage and power angle of generators are often measured by the electrical calculation method. The internal voltage and power angle of generators are calculated by direct-axis reactance Xd, quadrature-axis reactance Xq, terminal voltage and current which measured real-time. This calculation method may result in deviation because the value of Xd and Xq may be changed when the generator running in different status. This paper proposes a kind of rotor position measurement method. The internal voltage and power angle of generators are gotten by using generator phase keying signal and terminal voltages. This method is independent of generator equivalent calculative models and the value of synchronous reactance. It has high accuracy and suitable for real-time power angle measurement when power grid is in a disturbing or transient processing.\",\"PeriodicalId\":435652,\"journal\":{\"name\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APAP.2011.6180792\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180792","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在传统的工程应用中,发电机的内部电压和功率角通常是通过电学计算方法来测量的。利用实时测量的直轴电抗Xd、正交轴电抗Xq、端电压和电流计算发电机内部电压和功率角。由于发电机在不同的运行状态下,Xd和Xq的值会发生变化,这种计算方法可能会产生偏差。提出了一种转子位置测量方法。利用发电机相位键控信号和终端电压得到发电机的内部电压和功率角。该方法不依赖于发电机等效计算模型和同步电抗的取值。该方法精度高,适用于电网处于扰动或暂态处理时的实时功率角测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rotor position measurement method for generator power angles
In traditional engineering applications, the internal voltage and power angle of generators are often measured by the electrical calculation method. The internal voltage and power angle of generators are calculated by direct-axis reactance Xd, quadrature-axis reactance Xq, terminal voltage and current which measured real-time. This calculation method may result in deviation because the value of Xd and Xq may be changed when the generator running in different status. This paper proposes a kind of rotor position measurement method. The internal voltage and power angle of generators are gotten by using generator phase keying signal and terminal voltages. This method is independent of generator equivalent calculative models and the value of synchronous reactance. It has high accuracy and suitable for real-time power angle measurement when power grid is in a disturbing or transient processing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信