大型风电场并网电力系统临界清净时间的比较分析

Zhiwei Wen, Shi-en He
{"title":"大型风电场并网电力系统临界清净时间的比较分析","authors":"Zhiwei Wen, Shi-en He","doi":"10.1109/APAP.2011.6180391","DOIUrl":null,"url":null,"abstract":"The analysis of transient stability of power system connected with large wind farm is an important issue in the planning and operation of wind farm because the reactive power variation and the real power variation of wind farm interconnected with power grid leads to voltage fluctuation and frequency fluctuation of power grid. Impact of large scale wind farm integration on electric power system, effect on electric power system produced by development of wind power in a local grid typically in China has been represented. Based on electromagnetic transient software DIgSILENT/PowerFactory, the interconnected wind farm model and VSC-HVDC model as well as HVAC and HVDC model are set up. Comparative analysis of post-fault transient performance of wind turbines with different type of tie-line has been proposed. As a character of transient stability of power system, critical clearing time of three-phase short-circuit fault is studied in this paper. The digital simulation results show that VSC-HVDC is a better measure to solve the problems of system instability due to large wind farm integration. With VSC-HVDC transmission system, the transient stability of system can be improved better by flexible operation and control. Analysis of this paper should be provided as academic reference for improving design of interconnected wind farm system.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Comparative analysis on critical clearing time of power system connected with large wind farm\",\"authors\":\"Zhiwei Wen, Shi-en He\",\"doi\":\"10.1109/APAP.2011.6180391\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The analysis of transient stability of power system connected with large wind farm is an important issue in the planning and operation of wind farm because the reactive power variation and the real power variation of wind farm interconnected with power grid leads to voltage fluctuation and frequency fluctuation of power grid. Impact of large scale wind farm integration on electric power system, effect on electric power system produced by development of wind power in a local grid typically in China has been represented. Based on electromagnetic transient software DIgSILENT/PowerFactory, the interconnected wind farm model and VSC-HVDC model as well as HVAC and HVDC model are set up. Comparative analysis of post-fault transient performance of wind turbines with different type of tie-line has been proposed. As a character of transient stability of power system, critical clearing time of three-phase short-circuit fault is studied in this paper. The digital simulation results show that VSC-HVDC is a better measure to solve the problems of system instability due to large wind farm integration. With VSC-HVDC transmission system, the transient stability of system can be improved better by flexible operation and control. Analysis of this paper should be provided as academic reference for improving design of interconnected wind farm system.\",\"PeriodicalId\":435652,\"journal\":{\"name\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APAP.2011.6180391\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

大型风电场并网电力系统的暂态稳定性分析是风电场规划和运行中的一个重要问题,因为与电网并网的风电场的无功功率变化和实际功率变化会导致电网电压波动和频率波动。阐述了大型风电场并网对电力系统的影响,以及中国典型的局部电网风电开发对电力系统的影响。基于电磁暂态软件DIgSILENT/PowerFactory,建立了互联风电场模型、vdc -HVDC模型、HVAC -HVDC模型。对不同类型联络线的风力发电机组故障后暂态性能进行了对比分析。作为电力系统暂态稳定的一个特征,本文对三相短路故障的临界清除时间进行了研究。数字仿真结果表明,VSC-HVDC是解决大型风电场集成带来的系统不稳定问题的较好措施。在vdc - hvdc输电系统中,灵活的运行和控制可以更好地提高系统的暂态稳定性。本文的分析可为改进互联风电场系统的设计提供理论参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative analysis on critical clearing time of power system connected with large wind farm
The analysis of transient stability of power system connected with large wind farm is an important issue in the planning and operation of wind farm because the reactive power variation and the real power variation of wind farm interconnected with power grid leads to voltage fluctuation and frequency fluctuation of power grid. Impact of large scale wind farm integration on electric power system, effect on electric power system produced by development of wind power in a local grid typically in China has been represented. Based on electromagnetic transient software DIgSILENT/PowerFactory, the interconnected wind farm model and VSC-HVDC model as well as HVAC and HVDC model are set up. Comparative analysis of post-fault transient performance of wind turbines with different type of tie-line has been proposed. As a character of transient stability of power system, critical clearing time of three-phase short-circuit fault is studied in this paper. The digital simulation results show that VSC-HVDC is a better measure to solve the problems of system instability due to large wind farm integration. With VSC-HVDC transmission system, the transient stability of system can be improved better by flexible operation and control. Analysis of this paper should be provided as academic reference for improving design of interconnected wind farm system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信