{"title":"Comparison of the Current Carrying Capacity Between 110 kV Corrugated and Smooth Aluminum Sheathed Cables Based on Thermal Analysis","authors":"Guangyuan Yao, J. Lv, Xiaodong Hong, Xu Wang, Chen Jiang, Pingyuan Sun, Yiwen Shi, Hanshan Zhu, Xiangrong Chen","doi":"10.1109/EI256261.2022.10116233","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10116233","url":null,"abstract":"To compare the operating parameters of 110 kV smooth aluminum sheathed cables and corrugated aluminum sheathed cables, the thermal resistance, loss coefficient and current carrying capacity of the two are calculated by means of an equivalent thermal path analysis. The results show that the thermal resistance and losses of the smooth aluminum sheathed cable are less than those of the corrugated aluminum sheathed cable, which results in a load capacity of 776.88 A for the smooth aluminum sheathed cable, an increase of 10.8% compared to the load capacity of the corrugated aluminum sheathed cable. It is an indication that smooth aluminum sheathed cable has better economic and application prospects compared to corrugated aluminum sheathed cable.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124746821","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Multi-source Data Fusion Method in Monitoring Domain Based on Structural Similarity-Text Clustering and Ontology Glossary","authors":"Shujie Wu, Yinbin Yang, Xiaohui Pan","doi":"10.1109/EI256261.2022.10117352","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10117352","url":null,"abstract":"Data fusion is necessary for achieving muti-source data integration in power grid monitoring. In order to address the low accuracy of current data fusion approaches, this paper suggests a multi-source data fusion model based on structural similarity-text clustering and ontology glossary. The model uses the ontology glossary to store the clustering results and utilizes the DBSCAN algorithm based on structural similarity comparison to fuse the data. Finally, this paper compares the above model to the traditional k-means and DBSCAN model using data from the grid. The results demonstrate that the model in this paper has a higher data fusion accuracy, which suggests this model may successfully raise the level of data integration for power grid monitoring.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130496840","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jiaming Zhang, Zejie Tan, Zhenheng Xu, Zhong Liu, B. Tian, Zhiming Wang, Q. Lv, Bofeng Luo, Xinting Liu, Jun Hu
{"title":"A Novel Optimized Gauss Integral for Transmission Line Voltage Measurement","authors":"Jiaming Zhang, Zejie Tan, Zhenheng Xu, Zhong Liu, B. Tian, Zhiming Wang, Q. Lv, Bofeng Luo, Xinting Liu, Jun Hu","doi":"10.1109/EI256261.2022.10116830","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10116830","url":null,"abstract":"Gauss integral method, Chebyshev integral method, and Gauss-Legendre integral method are the main methods used for the non-contact voltage measurement to inverse the electric field. However, these methods don’t consider the influence of sensor position deviation. And the sensor position distribution might be unreasonable in these methods. Therefore, this paper proposed a novel optimized Gauss integral for transmission line voltage measurement, which combines the Gauss integral method and genetic algorithm. Furthermore, position sensitivity constraint condition is taken into the genetic algorithm. It is found that the optimized Gauss integral method improves the calculation accuracy greatly and makes the sensor distribution more reasonable for single conductors and double loop conductors, and for the catenary line, the optimized Gauss integral method used below the highest point of the catenary line is the only useful method.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126860009","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research on Economic Operation of Distribution Network Considering Energy Storage and Electric Vehicle Charging Station","authors":"Xiangyu Lv, Xuefei Chang, Jiarui Wang, D. Li, Xiangdong Meng, Chang-Ri Cui, Kaijun Zhang","doi":"10.1109/EI256261.2022.10116503","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10116503","url":null,"abstract":"The penetration of electric vehicles and energy storage devices in the power system is increasing, and they can participate in the optimal dispatch of the distribution network as adjustable resources. Firstly, based on the tidal model, energy storage operation model and electric vehicle cluster charging station model, a distribution network economic dispatching model is established, with minimization of network loss and minimization of charging cost of energy storage and charging stations as the day-ahead dispatching objectives. Secondly, a distributed solution scheme based on alternating direction multiplication algorithm with master-slave structure is designed for this optimization model to give full play to the autonomous coordination of resources within the distribution network. Finally, the simulation shows that the participation of energy storage and charging stations in the distribution network dispatch is beneficial to the energy storage operator and the distribution network in both directions, and the distributed solution scheme based on alternating direction multiplication algorithm is effective.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130678604","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Collaborative Emergency Control Strategy Providing Transient Stability After HVDC-link Blocking","authors":"Jiawei Hu, H. Nee, Tong Wang, Zengping Wang","doi":"10.1109/EI256261.2022.10117100","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10117100","url":null,"abstract":"Continuous commutation failures of line-commutated high-voltage direct current converter caused by AC faults lead to the blocking of HVDC-link. This may seriously threaten the stability of post-fault power system. Therefore, a collaborative emergency control strategy making use of DC power support is presented to guarantee transient stability after HVDC-link blocking. Firstly, the control enabling criterion is defined based on the variation characteristics of the phase trajectory slope during the first swing, while the analytical equation between the needed control quantity and the system parameters is derived. Secondly, the mathematical relation between the provided control quantity and the number of HVDC-links participating in the power support is deduced, and the participation sequence is determined on the basis of the post-fault stable equilibrium points. Additionally, the time delay of the whole implementation is considered. Finally, the effectiveness of presented control strategy is validated using the improved IEEE 68-bus AC/DC hybrid power system.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"233 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124210613","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Distributed Energy Storage Optimal Scheduling in Distribution Network Based on the K-means++ Algorithm","authors":"Qiuyan Zhang, Mingming Xu, Bowen Shang, Yuanyu Ge, Denghui Fu, Jun Xie","doi":"10.1109/EI256261.2022.10117126","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10117126","url":null,"abstract":"Distributed energy storage technology can solve the problems of load peak-valley difference faced by distribution networks. Reasonable and efficient dispatch of distributed energy storage is a significant approach to play its performance in distribution network. However, the direct participation of large-scale distributed energy storages in distribution network will bring about many problems, such as the explosion of the dimension of decision variables and the difficulty of convergence of the solution results. In this paper, large-scale distributed energy storage is aggregated into a small number of characteristic clusters based on typical characteristic quantities, and an aggregation-scheduling model is established to deal with massive distributed energy storage resources participating in distribution network operation. Simulation results demonstrate that the proposed method reduces the dimension of variables and lower the level of the solving difficulty, which can proceed to schedule the distributed energy storage reasonably and intensify the feasibility in optimization.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123616484","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Two-Stage Robust Economic and Carbon Emission Optimal Scheduling of Integrated Energy System","authors":"Chenjian Zhang, Chenbin Lu, Z. Bao","doi":"10.1109/EI256261.2022.10117275","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10117275","url":null,"abstract":"A two-stage robust optimization model with min-max-min formulation is proposed for the cooling-heating-electricity-gas integrated energy system (IES), respectively with the optimization objective of minimizing operation cost and carbon emission. The uncertainties of photovoltaic (PV) output and electricity demand are considered. The middle and inner layers are reformulated into a single-layer optimization by using duality theory and big-M method. The outer layer searches for the electricity purchase or sale decision considering the worst-case scenario, determined by the middle and inner layer. Column and constraint generation (C&CG) algorithm are employed to solve the two-stage model. Case study demonstrates the effectiveness of the presented model and shows the different scheduling results under the economic and carbon emission objectives.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123620718","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research on Inertia Allocation Scheme for Improving Frequency Safety and Stability Characteristics of Power Grid","authors":"Xu Xian, Wu Xuelian, L. Zhaowei, H. Hui","doi":"10.1109/EI256261.2022.10116443","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10116443","url":null,"abstract":"With the increase in the proportion of new energy power generation and DC power generation outside the region, the inertia demand under the frequency security constraints is becoming more and more urgent. Firstly, the relationship between the frequency response characteristics of the power grid and the total inertia of the system and the relationship between the frequency distribution characteristics of the multi-machine system and the inertia distribution are analyzed. Aiming at the frequency safety constraints of the power grid, an estimation method for the minimum inertia demand of the system is proposed. Considering the frequency distribution characteristics of the power grid and the distribution of load, new energy and direct current, the distribution scheme of inertia among different regions in the synchronous power grid is proposed to guide the arrangement of the power-on and output of the synchronous units in the system. The simulation analysis based on the actual large power grid in East China power grid shows that for the power system with large amount of new energy generation and DC feed, the method can effectively reduce the maximum deviation of frequency and the difference of time-space distribution, which verifies the effectiveness of the proposed method.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121137989","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Joint Optimization of Energy Storage and Energy-intensive Load at Renewable Energy Transmission End","authors":"Xinyue Yun, Haohui Ding, Yaodong Wu, Pengfei Song, Pengpeng Kang, Yingwei Jiang","doi":"10.1109/EI256261.2022.10116398","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10116398","url":null,"abstract":"With the rapid development of wind power, the randomness and volatility of wind power have led to increasing pressure on peak regulation and frequency regulation of the power grid, and wind curtailment is serious, especially in the renewable energy transmission end. In this paper, large-scale energy storage and energy-intensive load with adjustable characteristics are taken as important means to promote wind power consumption and participate in the optimal dispatch of the power grid together with conventional thermal power. This work proposes a new model of source-storage-load coordination, which comprehensively considers the impact of source-load coordination on wind power consumption, system operating costs, and energy storage benefits. It optimizes thermal power, energy storage, and energy-intensive load operation to minimize the overall cost of power grid and energy storage. The study's results verify the proposed method's effectiveness in improving the consumption level of wind power and peak cutting.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116324139","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Xiaoyuan Luo, Ruiyang Gao, Xinyu Wang, Xiangjie Wang
{"title":"An Adaptive LQR-Based Defense Strategy against False Data Injection Attack in Smart Grids","authors":"Xiaoyuan Luo, Ruiyang Gao, Xinyu Wang, Xiangjie Wang","doi":"10.1109/EI256261.2022.10117083","DOIUrl":"https://doi.org/10.1109/EI256261.2022.10117083","url":null,"abstract":"With the rapid development of cyber-physical power system, the security risk caused by false data injection attacks on the power system is increasing. Due to the covert characteristics of false data injection, the existing detection methods can be deceived and lead to power system overload. To solve this problem, an adaptive defense method based on the linear-quadratic form (LQR) is proposed. Considering the impact of attack on the physical system, a physical dynamic model of the power grid is constructed. Taking the covert characteristics of false data injection attack into account, the adaptive LQR controller-based defense method is developed. Through the design of parameters of LQR, the proposed controller can respond quickly to deceptive attacks. Then, the developed LQR-based adaptive control method can ensure the stability of the system as soon as possible after being attacked. Finally, the performance of the proposed control method to restore the stability of power systems under false data injection attack is verified on the IEEE 5-bus.","PeriodicalId":413409,"journal":{"name":"2022 IEEE 6th Conference on Energy Internet and Energy System Integration (EI2)","volume":"134 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116343436","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}