2009 International Symposium on Micro-NanoMechatronics and Human Science最新文献

筛选
英文 中文
Genetic algorithm based parameters adjustments for micron-order image analysis of metal fracture 基于遗传算法的金属断裂微米级图像分析参数调整
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5351865
M. Mizoguchi, K. Obata, Y. Kato, K. Ogata
{"title":"Genetic algorithm based parameters adjustments for micron-order image analysis of metal fracture","authors":"M. Mizoguchi, K. Obata, Y. Kato, K. Ogata","doi":"10.1109/MHS.2009.5351865","DOIUrl":"https://doi.org/10.1109/MHS.2009.5351865","url":null,"abstract":"A brittle fracture, which is a kind of metal fractures, accompanies little or no plastic deformations of the metal, The origin of the fracture is one of the most important clues to identify the cause of it, and can be located by observing the surface. Here, fractography is an area of study to analyze fracture mechanisms and/or causes by using electron microscope images. The method to locate the origins has been established through it. However, they have been done mainly by visual observations. At MHS2007, we proposed a method to improve its measurement accuracy to micron order by introducing computer vision techniques on Scanning Electron Microscope, or SEM, digital images [1]. However, some parameters were manually determined and required to be automated. This is a continued research of it. We propose, in this paper, a new method to determine proper parameters for image segmentation using Genetic Algorithms (GAs.) Through experiments, we proved the scheme worked properly, and suboptimal parameters were determined so that the greatest number of cleavage steps was obtained. It is expected that these proposed methods will enable non-experts to analyze metal fractures accurately in micron scale.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122440837","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Miniaturization of a wide range load sensor using AT-cut quartz crystal resonator 采用at切割石英晶体谐振器的大量程负载传感器小型化
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5351808
K. Narumi, T. Fukuda, F. Arai
{"title":"Miniaturization of a wide range load sensor using AT-cut quartz crystal resonator","authors":"K. Narumi, T. Fukuda, F. Arai","doi":"10.1109/MHS.2009.5351808","DOIUrl":"https://doi.org/10.1109/MHS.2009.5351808","url":null,"abstract":"A compact load sensor we developed uses an AT-cut quartz crystal resonator whose resonance frequency changes under external load, and features high sensitivity, high-speed response, and a wide measurement range. Also it has the superior feature in the temperature and frequency stability. In the past, the quartz crystal resonator had been hardly applied to the load measurement because of low degree of mechanical characteristic, that is, it is weak to stress concentration by bending. We have developed and characterized a sensor mechanism that safely maintains the quartz crystal resonator. The sensor had enormously wide range of 104 N. The objective of this study is to miniaturize the sensor and to improve the resolution of load measurement. We designed a novel retention mechanism of the quartz crystal resonator which had frictionless structure. We calculated and analyzed about the new retention mechanism, and determined parameters. The size of the retention mechanism was 7.0 mm wide, 4.0 mm deep and 1.9 mm high, which was 40.3% of the conventional one (volume ratio).","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117049646","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Purification of wheat factors involving in translation initiation for reconstitution of protein synthesis 小麦蛋白合成重组翻译起始因子的纯化
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5352036
H. Nagano, S. Fukada, H. Takagi, T. Ogasawara, Y. Endo, K. Takai
{"title":"Purification of wheat factors involving in translation initiation for reconstitution of protein synthesis","authors":"H. Nagano, S. Fukada, H. Takagi, T. Ogasawara, Y. Endo, K. Takai","doi":"10.1109/MHS.2009.5352036","DOIUrl":"https://doi.org/10.1109/MHS.2009.5352036","url":null,"abstract":"We are making efforts to construct a reconstituted cell-free protein synthesis system with the components from wheat. We report here on our progress in purification of some factors expected to be needed for reconstitution of efficient translation initiation. eIF1A and eIF5 were overexpressed in E. coli and purified essentially according to the literature. Some hydrophobic chromatography media were tested if they can be used for purification of the wheat ribosomes. We also fractionated a wheat embryo extract and analyzed which fractions contain an RNA binding protein that bind to a translational enhancer sequence.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121799869","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Giant liposome sorting/collection device: For individual analysis of artificial cell-models 巨型脂质体分选/收集装置:用于人工细胞模型的个体分析
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5352048
S. Nomura, Li Liu, Yong Chen, H. Maruyama, F. Arai
{"title":"Giant liposome sorting/collection device: For individual analysis of artificial cell-models","authors":"S. Nomura, Li Liu, Yong Chen, H. Maruyama, F. Arai","doi":"10.1109/MHS.2009.5352048","DOIUrl":"https://doi.org/10.1109/MHS.2009.5352048","url":null,"abstract":"In this report, we will present a novel liposome handling method on microfluidic channel. For the quantitative analysis of individual giant liposomes, a microfluidic device with multi-pillar was designed. Liposomes suspension from neutral phospholipids prepared by natural swelling method was introduced into the separation device. As a result, giant liposomes are safely trapped in the microscope viewfield along with the internal pillar within a weak flow. In the condition, small solutes (excess dye molecules, small liposomes) are washed away through the pillars. This system should be useful for time-course analysis of individual cell-sized liposomes.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131056769","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Thermo-sensitive sol-gel transition and mechanical properties of poly(Depsipeptide-co-lactide)-g-PEG copolymers 聚(Depsipeptide-co-lactide)-g-PEG共聚物的热敏溶胶-凝胶过渡和力学性能
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5351825
Y. Ohya, K. Nagahama, Y. Imai, Teppei Nakayama, T. Ouchi
{"title":"Thermo-sensitive sol-gel transition and mechanical properties of poly(Depsipeptide-co-lactide)-g-PEG copolymers","authors":"Y. Ohya, K. Nagahama, Y. Imai, Teppei Nakayama, T. Ouchi","doi":"10.1109/MHS.2009.5351825","DOIUrl":"https://doi.org/10.1109/MHS.2009.5351825","url":null,"abstract":"Thermo-gelling biodegradable polymers with a sol-gel transition point (Tgel) between room temperature and body temperature are expected to be useful for injectable polymer systems in biomedical applications such as drug delivery depot and scaffold for tissue engineering. In this study, a series of biodegradable graft-copolymers composed of PEG side-chains and a poly(depsipeptide-co-DL-lactide) backbone (PDG-dl-LA-g-PEG) were prepared as a novel thermo-gelling system. An aqueous solution of the copolymer showed instantaneous temperature-sensitive gelation at 33 ºC. The Tgel could be controlled from 33 to 51 ºC by varying the PEG length and compositions without a decrease in mechanical strength of the hydrogels. This research provides a molecular design approach to creating biodegradable thermo-gelling polymers with controllable Tgel and mechanical toughness.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122125454","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Rotational speed control of Na+-driven flagellar motor by local ion concentration changes with multiple nano/micro pipettes 多个纳微移液管局部离子浓度变化对Na+驱动鞭毛马达转速的控制
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5351830
K. Nogawa, M. Kojima, M. Nakajima, M. Homma, T. Fukuda
{"title":"Rotational speed control of Na+-driven flagellar motor by local ion concentration changes with multiple nano/micro pipettes","authors":"K. Nogawa, M. Kojima, M. Nakajima, M. Homma, T. Fukuda","doi":"10.1109/MHS.2009.5351830","DOIUrl":"https://doi.org/10.1109/MHS.2009.5351830","url":null,"abstract":"Nano/micro robots have been actively studied toward the realization. Now, the micro living organisms are used as the driving forces for the micro objects. To achieve the fine control of bio driven micro objects, it is needed to establish the control method. Therefore, the local environmental control technique is desired to manipulate a single cell or to analyze the properties. We have constructed the local environmental control system with nano/micro dual pipettes, and achieved the quick-response and iterative rotational speed control of Na<sup>+</sup>-driven flagellar motor, which is a rotary molecular machine, by switching the local spout between Na<sup>+</sup>-containing and Na<sup>+</sup>-free solutions. In this paper, we upgrade our local environmental control system with nano/micro dual pipettes to achieve the quantitative and long-time-stable control of the rotational speed of the Na<sup>+</sup>-driven flagellar motor. We demonstrate fine and long-time-stable rotational speed control of Na<sup>+</sup>-driven flagellar motor by simultaneous local spouts of Na<sup>+</sup>-containing and Na<sup>+</sup>-free solutions with changing the spouting velocities independently.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126684144","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Discreet controller structure for robust oscillating nonlinear stable system 鲁棒振荡非线性稳定系统的离散控制器结构
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5352017
M. Moteleb, Š. Kozák
{"title":"Discreet controller structure for robust oscillating nonlinear stable system","authors":"M. Moteleb, Š. Kozák","doi":"10.1109/MHS.2009.5352017","DOIUrl":"https://doi.org/10.1109/MHS.2009.5352017","url":null,"abstract":"This paper is presented to investigate the validity of designing a discreet controller of feed- forward and feedback structure which may be used to improve the dynamic performance of either linear or nonlinear systems. By transforming the continuous plant as well as transforming the associated controller to the discreet domain with including all parameters changes and their influence for closed loop stability as well as the desired robust control synthesis, we can construct the required controller to ensure the overall stability of strong oscillating dynamic model. This algorithm was verified by using different numerical models. The results obtained are compared with those given in the speed control of switched reluctance motor based on the hybrid fuzzy variable structure control FSMC with the concept of Lyap nov second method. Practically we can conclude that the FVSC technique may be recommended to overcome some of the drawbacks associated with the application of the discreet controller structure algorithm.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129329638","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Micro-encapsulation of bio-actuator using insect dorsal vessel 昆虫背血管微胶囊化生物致动器
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5351970
Yuta Touyama, T. Hoshino, K. Iwabuchi, K. Morishima
{"title":"Micro-encapsulation of bio-actuator using insect dorsal vessel","authors":"Yuta Touyama, T. Hoshino, K. Iwabuchi, K. Morishima","doi":"10.1109/MHS.2009.5351970","DOIUrl":"https://doi.org/10.1109/MHS.2009.5351970","url":null,"abstract":"Bio-actuators using living cells or tissue cannot work outside culture dish filled with culture medium. Therefore, the limitation of bio-actuator's operating environment is difficult problem compared to conventional micro actuator. To solve this problem, we focused on packaging of insect dorsal vessel and its culture medium by exoskeletal structure. By packaging of insect dorsal vessel and its culture medium, the bio-actuator using insect dorsal vessel would work outside culture dish filled with culture medium. We fabricated exoskeletal structure that has micro through-holes. The TC−100 culture medium was filled inside exoskeletal structure, without its leakage due to surface tension. We fabricated micro-manipulator using contracting force of insect dorsal vessel. The open-end displacement by contracting force of insect dorsal vessel was approximately 60 μm. After the assembly of insect dorsal vessel into exoskeletal structure filled with culture medium inside, the contracting of insect dorsal vessel was confirmed.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"228 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124519659","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Development of a pH indicator immobilized-gel-sheet for microenviroment analysis 微环境分析用pH指示剂固定化凝胶片的研制
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5351885
T. Masuda, H. Maruyama, F. Arai, T. Anada, T. Fukuda, O. Suzuki
{"title":"Development of a pH indicator immobilized-gel-sheet for microenviroment analysis","authors":"T. Masuda, H. Maruyama, F. Arai, T. Anada, T. Fukuda, O. Suzuki","doi":"10.1109/MHS.2009.5351885","DOIUrl":"https://doi.org/10.1109/MHS.2009.5351885","url":null,"abstract":"Detection of change in microenvironmental pH may be essential for analyzing biological processes, if transitory biodegradable scaffold materials are used for tissue engineering in bone regeneration. In this study, we created a pH indicator immobilized-gel-sheet for pH measurement. By using gel-sheet, we can investigate the local microenvironment of biodegradable materials, such as octacalcium phosphate (OCP), under the various protein adsorptions. The gel-sheet was made of a photocrosslinkable prepolymer solution (TUPR-5), which was easily immobilized by the method that the pH indicator is entrapped in a porous polymeric substrate. Bromothymol Blue (BTB) immobilized-gel-sheet was mounted in a biochip made of polydimethylsiloxane (PDMS) with a flow channel. The pH value was calculated by detecting the color changes, and presented as the pH distribution via a custom-made application. The pH sensing was carried out based on the surrounding color information of an OCP granule if incubated in culture medium. The gel-sheet detected the pH values of the condition around an OCP granule, showing the decrease from pH 7.8 to 8.8. As a whole, the proposed pH indicator is capable of providing pH level by high-spatial resolution.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131936757","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Rapid immunosensing based on accumulation of microparticles by negative dielectrophoresis 基于负电介质电泳微粒子积累的快速免疫传感
2009 International Symposium on Micro-NanoMechatronics and Human Science Pub Date : 2009-12-11 DOI: 10.1109/MHS.2009.5352000
T. Yasukawa, H. J. Lee, J. Ramón‐Azcón, Yusuke Yoshida, H. Shiku, T. Matsue, F. Mizutani
{"title":"Rapid immunosensing based on accumulation of microparticles by negative dielectrophoresis","authors":"T. Yasukawa, H. J. Lee, J. Ramón‐Azcón, Yusuke Yoshida, H. Shiku, T. Matsue, F. Mizutani","doi":"10.1109/MHS.2009.5352000","DOIUrl":"https://doi.org/10.1109/MHS.2009.5352000","url":null,"abstract":"In the work, microfluidic device consisting of an interdigitated microarray (IDA) electrode was developed for a rapid, and separation-free immuno-sensors based on a manipulation technique of microparticles by dielectrophoresis (DEP). A poly-dimethylsiloxane (PDMS) substrate with microfluidic channel was placed on the IDA plate to allow to fabricating the device. On applying AC voltage to the IDA in a negative DEP (n-DEP) frequency region, goat anti-mouse immunoglobulin (anti-mouse IgG)-immobilized microparticles moved to the surface of PDMS substrate placed above the IDA by n-DEP force to accumulate at the designated areas of the PDMS surface, where anti-mouse IgG was precoated. When the fluorescence microparticles bearing anti-mouse IgG were suspended in an analyte (mouse IgG) solution, the microparticles trapped the analyte to form microparticle-conjugates. The conjugates were accumulated and captured at the designated areas of the PDMS surface via antibody-antigen-antibody (sandwich) reaction. The captured microparticles were detected selectively by fluorescence measurements at the focused, designated areas regardless of the presence of uncaptured microparticles in the suspended solution. Thus, the separation and washing-out steps, usually required for conventional immunoassay, are eliminated in the presented procedure. Since the formation of the sandwich structures was accelerated significantly by n-DEP, as short as 30 sec was enough to detect the immunoreaction at the surface. The fluorescence intensity of the captured microparticles at the designated area increased with the analyte in the range, 0.01 ~ 10 ng/mL. The present procedure realizes a rapid, sensitive and separation-free immunoassay in a simple device.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134074719","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信