{"title":"微环境分析用pH指示剂固定化凝胶片的研制","authors":"T. Masuda, H. Maruyama, F. Arai, T. Anada, T. Fukuda, O. Suzuki","doi":"10.1109/MHS.2009.5351885","DOIUrl":null,"url":null,"abstract":"Detection of change in microenvironmental pH may be essential for analyzing biological processes, if transitory biodegradable scaffold materials are used for tissue engineering in bone regeneration. In this study, we created a pH indicator immobilized-gel-sheet for pH measurement. By using gel-sheet, we can investigate the local microenvironment of biodegradable materials, such as octacalcium phosphate (OCP), under the various protein adsorptions. The gel-sheet was made of a photocrosslinkable prepolymer solution (TUPR-5), which was easily immobilized by the method that the pH indicator is entrapped in a porous polymeric substrate. Bromothymol Blue (BTB) immobilized-gel-sheet was mounted in a biochip made of polydimethylsiloxane (PDMS) with a flow channel. The pH value was calculated by detecting the color changes, and presented as the pH distribution via a custom-made application. The pH sensing was carried out based on the surrounding color information of an OCP granule if incubated in culture medium. The gel-sheet detected the pH values of the condition around an OCP granule, showing the decrease from pH 7.8 to 8.8. As a whole, the proposed pH indicator is capable of providing pH level by high-spatial resolution.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Development of a pH indicator immobilized-gel-sheet for microenviroment analysis\",\"authors\":\"T. Masuda, H. Maruyama, F. Arai, T. Anada, T. Fukuda, O. Suzuki\",\"doi\":\"10.1109/MHS.2009.5351885\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Detection of change in microenvironmental pH may be essential for analyzing biological processes, if transitory biodegradable scaffold materials are used for tissue engineering in bone regeneration. In this study, we created a pH indicator immobilized-gel-sheet for pH measurement. By using gel-sheet, we can investigate the local microenvironment of biodegradable materials, such as octacalcium phosphate (OCP), under the various protein adsorptions. The gel-sheet was made of a photocrosslinkable prepolymer solution (TUPR-5), which was easily immobilized by the method that the pH indicator is entrapped in a porous polymeric substrate. Bromothymol Blue (BTB) immobilized-gel-sheet was mounted in a biochip made of polydimethylsiloxane (PDMS) with a flow channel. The pH value was calculated by detecting the color changes, and presented as the pH distribution via a custom-made application. The pH sensing was carried out based on the surrounding color information of an OCP granule if incubated in culture medium. The gel-sheet detected the pH values of the condition around an OCP granule, showing the decrease from pH 7.8 to 8.8. As a whole, the proposed pH indicator is capable of providing pH level by high-spatial resolution.\",\"PeriodicalId\":344667,\"journal\":{\"name\":\"2009 International Symposium on Micro-NanoMechatronics and Human Science\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Symposium on Micro-NanoMechatronics and Human Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MHS.2009.5351885\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Symposium on Micro-NanoMechatronics and Human Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MHS.2009.5351885","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

如果暂时的可生物降解支架材料用于骨再生的组织工程,检测微环境pH值的变化可能是分析生物过程所必需的。在这项研究中,我们创建了一个pH指示剂固定化凝胶片用于pH测量。利用凝胶片,我们可以研究生物降解材料,如OCP,在不同蛋白质吸附下的局部微环境。凝胶片由可光交联的预聚物溶液(TUPR-5)制成,通过将pH指示剂包埋在多孔聚合物衬底上的方法易于固定化。将溴百里酚蓝(BTB)固定化凝胶片安装在具有流道的聚二甲基硅氧烷(PDMS)生物芯片上。通过检测颜色变化计算pH值,并通过定制应用程序表示为pH分布。根据OCP颗粒在培养基中孵育的周围颜色信息进行pH感应。凝胶片检测了OCP颗粒周围环境的pH值,pH值从7.8下降到8.8。总体而言,所提出的pH指示剂能够提供高空间分辨率的pH水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a pH indicator immobilized-gel-sheet for microenviroment analysis
Detection of change in microenvironmental pH may be essential for analyzing biological processes, if transitory biodegradable scaffold materials are used for tissue engineering in bone regeneration. In this study, we created a pH indicator immobilized-gel-sheet for pH measurement. By using gel-sheet, we can investigate the local microenvironment of biodegradable materials, such as octacalcium phosphate (OCP), under the various protein adsorptions. The gel-sheet was made of a photocrosslinkable prepolymer solution (TUPR-5), which was easily immobilized by the method that the pH indicator is entrapped in a porous polymeric substrate. Bromothymol Blue (BTB) immobilized-gel-sheet was mounted in a biochip made of polydimethylsiloxane (PDMS) with a flow channel. The pH value was calculated by detecting the color changes, and presented as the pH distribution via a custom-made application. The pH sensing was carried out based on the surrounding color information of an OCP granule if incubated in culture medium. The gel-sheet detected the pH values of the condition around an OCP granule, showing the decrease from pH 7.8 to 8.8. As a whole, the proposed pH indicator is capable of providing pH level by high-spatial resolution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信