2011 IEEE Industry Applications Society Annual Meeting最新文献

筛选
英文 中文
Using coreless hall effect sensor for accurate current measurement in ZigBee based wireless sensor network 在基于ZigBee的无线传感器网络中使用无芯霍尔效应传感器实现精确的电流测量
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074297
Kun-Long Chen, Yuan-Pin Tsai, N. Chen, S. Korkua, Weijen Lee
{"title":"Using coreless hall effect sensor for accurate current measurement in ZigBee based wireless sensor network","authors":"Kun-Long Chen, Yuan-Pin Tsai, N. Chen, S. Korkua, Weijen Lee","doi":"10.1109/IAS.2011.6074297","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074297","url":null,"abstract":"This study combines coreless Hall effect current transformers (HCTs), ZigBee communication, and a quiescent voltage adjustment to develops a new current measurement method for non-straight conducting wires. The proposed design includes the unique characteristics of low cost, low power consumption, and wireless communication capability that makes it flexible for current measurement at different environments. In addition, the quiescent voltage adjustment enable the adjustment of DC voltage level to eliminate the DC 2.5±0.05 V quiescent voltage requirement in each Hall sensor for an easy signal transformation in back-end monitoring systems. Simulation and measurement results show that HCTs can eliminate the problems of asymmetric magnetic flux density distributions outside the conducting wire which originated from its non-straight structure or its asymmetric cross-section. The accuracy class of the current measurements using HCTs can meet the 0,5 class according to IEC standard and their current waveforms do not suffer the saturation from using traditional CTs.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123037635","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Modeling and design of an improved current-fed converter with new voltage multiplier circuit combination 采用新型电压乘法器电路组合的改进电流馈电变换器的建模与设计
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074399
Y. Liao, Ching-Ming Lai, Y. Ke
{"title":"Modeling and design of an improved current-fed converter with new voltage multiplier circuit combination","authors":"Y. Liao, Ching-Ming Lai, Y. Ke","doi":"10.1109/IAS.2011.6074399","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074399","url":null,"abstract":"The objective of this paper is focused on developing an improved current-fed converter with new voltage multiplier circuit for low-voltage distributed energy systems. The proposed four-phase current-fed converter is with interleaved configuration and preserving the inherent advantage with smaller input current ripple. Through the proposed topology, the high voltage gain can be achieved using the relatively lower transformer turns ratio. Also, the voltage stresses of both active switches and diodes are greatly reduced so that the low on-resistance switches can be adopted and the reverse-recovery effect of diodes can be decreased naturally. The DC and AC small signal models of the proposed converter are derived for better closed loop control, and some design guidelines are then given for circuit implementation. Both simulation and experimental results indeed verify the effectiveness of the proposed converter.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121587055","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Load model development for next generation appliances 下一代电器的负载模型开发
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074402
F. Quilumba, Weijen Lee, Heng Huang, David Yanshi Wang, Robert L. Szabados
{"title":"Load model development for next generation appliances","authors":"F. Quilumba, Weijen Lee, Heng Huang, David Yanshi Wang, Robert L. Szabados","doi":"10.1109/IAS.2011.6074402","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074402","url":null,"abstract":"Substantial changes in the nature of the loads have occurred recently with the development of the new technologies. This makes it clear that it is necessary to update the load model and provide an accurate representation of the new generation loads. This paper describes the development of the new appliances load model, such as LCD TV, LED TV, and game consoles (Xbox 360™, Wii™, and PS3™), because they become the common appliances that can be found in most of the customers' home. Since ZIP load model is a well known model which establishes the dependency of the power with respect to voltage with physical meaning, this paper follows the same concept to develop the load models that can be seamlessly adopted into commercially available program for better representation.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114864642","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 26
Supercapacitors modeling and integration in transport applications 超级电容器在运输应用中的建模和集成
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074422
M. Camara, H. Gualous, B. Dakyo
{"title":"Supercapacitors modeling and integration in transport applications","authors":"M. Camara, H. Gualous, B. Dakyo","doi":"10.1109/IAS.2011.6074422","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074422","url":null,"abstract":"This paper presents an approach of Supercapacitors integration in transport applications. This proposal is due to the present trend in the transport applications, knowing that the major drawback in these last is the energetic autonomy problem and the DC-bus voltage sags. In this context, using Supercapacitors (SC) and Fuel Cell or Battery with a good strategy for energy management is a promising solution to improve the system performances. The main contributions of this paper present two aspects: The first is based on 54V-Supercapacitors module behavior modeling and experimental parameters identification. Second aspect, is focused on DC-bus voltage and currents control strategies based on polynomial controller. These strategies are implemented in the PIC18F4431 microcontroller for DC/DC converters control. Due to reasons of cost and available components, the experimental test bench is carried out in reduced scale. Through some simulations and experimental results obtained in reduced scale, the authors present an improved energy management strategy for transport applications.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130996707","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Solar power battery charger with a parallel-load resonant converter 带并联负载谐振变换器的太阳能电池充电器
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074300
Y. Ke, Y. Chuang, Mei-Sung Kang, Yuan-Kang Wu, Ching-Ming Lai, Chien-Chih Yu
{"title":"Solar power battery charger with a parallel-load resonant converter","authors":"Y. Ke, Y. Chuang, Mei-Sung Kang, Yuan-Kang Wu, Ching-Ming Lai, Chien-Chih Yu","doi":"10.1109/IAS.2011.6074300","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074300","url":null,"abstract":"Although fossil fuels have led us to economic prosperity, the extensive use has caused a substantial reduction of fossil fuels. Therefore, the solar energy, as one of the green energy resources, has become an important alternative for the future. In this paper, the parallel loaded resonant converter with the feature of the soft switching technique was used in the circuits of the solar storage battery charger. To avoid the damage of the battery charger due to the variation of the output current of the solar PV panels, a closed-loop boost converter between the solar PV panel and the battery charger was designed to stabilize the output current of the solar PV panel. By designing the characteristic impedance of the resonant tank, the charging current of the storage battery can be calculated and then the charging time for the storage battery can further be estimated. By properly designing the circuit parameters, the parallel loaded resonant converter can be operated in the continuous current conduction mode and the switch can be switched for conduction at zero voltage. The experimental results verified the correctness of the theoretic estimation for the proposed battery charger circuit. The average charging efficiency of the battery charger can be up to 88.7%.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124342814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Connectivity of DC microgrids involving sustainable energy sources 涉及可持续能源的直流微电网的连通性
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074338
A. Mohamed, O. Mohammed
{"title":"Connectivity of DC microgrids involving sustainable energy sources","authors":"A. Mohamed, O. Mohammed","doi":"10.1109/IAS.2011.6074338","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074338","url":null,"abstract":"In this paper, a proposed configuration for connection of different DC microgrids has been presented. The DC system under study is assumed mainly dependent on renewable energy sources. The proposed topology utilizes a controlled series current compensator (CSCC) technique for connection and power flow control among buses. The proposed topology allows full power flow control among different DC buses while keeping the voltage level constant at all of them. Hence, loads connected to these buses will not be affected with the power flow process. Moreover, connection of buses at different voltage level and controlling the power flow can be easily achieved using this topology. The proposed topology adds to the complexity of the system. However, several advantages can be obtained out of its utilization. Simulation results verified the applicability of the proposed topology. Moreover, a prototype system has been designed and built in hardware to examine the performance of the proposed system. The experimental results show the validity of the proposed system as a powerful technique to interconnect DC buses.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114303590","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
A closer look at bonding grounding electrodes (NEC 2011, article 250 requirements) 仔细检查连接接地电极(NEC 2011,第250条要求)
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074262
Devine Pe
{"title":"A closer look at bonding grounding electrodes (NEC 2011, article 250 requirements)","authors":"Devine Pe","doi":"10.1109/IAS.2011.6074262","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074262","url":null,"abstract":"This paper describes the grounding design of a 480V, 3-phase, 4-wire power distribution system for a rail transit facility consisting of a passenger station and two separate parking garages. The authority having jurisdiction (AHJ) made an interpretation of NEC Section 250.50 that the grounding electrodes of the power panels at three different locations should be bonded to the main switchboard grounding electrodes by installing underground bonding conductors. Designers disagreed with AHJ and were opposed to such installation. Due to physical locations of the panels and the switchboard within the facility, such installation was impractical. To meet NEC requirements and to satisfy AHJ, a discussion of bonding of facility grounding electrodes is included in this paper. At locations where underground bonding conductors were not practical to install, bonding of structural steel members with metallic conduits for feeder cables that carry equipment grounding conductors between the main switchboard and various power panels act as bonding conductors.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116808569","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Virtual models for the upgrading electric system in Mexican refineries, application in the tender process by 2011 and integration by 2013 墨西哥炼油厂升级电力系统的虚拟模型,2011年在招标过程中应用,2013年整合
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074428
L. Ruiz, F. Chavez, G. Rojas, E. Sosa
{"title":"Virtual models for the upgrading electric system in Mexican refineries, application in the tender process by 2011 and integration by 2013","authors":"L. Ruiz, F. Chavez, G. Rojas, E. Sosa","doi":"10.1109/IAS.2011.6074428","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074428","url":null,"abstract":"That paper shows a proposal to visualize in a fast way the tentative design of an electric upgrading in a Northern Mexican refinery, and the places where the primary electrical equipment are installed, which are described in tender bases specifications, generated in electrical upgrading projects, regarded in National Refining Industry (NRI). This paper shows a requirements analysis, software alternatives and its evaluation for the development of virtual paths. The virtual models where developed with a 3D design. Those models will improve time during work in field and meeting for clarifications, that are the first stages of aproachment between suppliers which sell the electrical equipment and NRI in the tender process by 2011 and starting up by 2013.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125844017","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A radial position control method of bearingless motor based on d-q axis current control 基于d-q轴电流控制的无轴承电机径向位置控制方法
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074331
S. Kobayashi, M. Ooshima, M. Uddin
{"title":"A radial position control method of bearingless motor based on d-q axis current control","authors":"S. Kobayashi, M. Ooshima, M. Uddin","doi":"10.1109/IAS.2011.6074331","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074331","url":null,"abstract":"This paper presents a radial position control method of bearingless motor (BELM) based on d-q axis current control and an integrated winding arrangement. The BELM performs the functions of motor as well as magnetic bearing. Rotor is suspended with non-contact by suspension force. In a conventional BELM, there are two kinds of stator windings such as motor and suspension windings. The motor winding outputs the rotational torque, and the suspension winding outputs the suspension force. To simplify the structure of conventional BELM, integration of two windings is proposed in this paper. By integrating the windings, the structure of BELM becomes simple and also the torque and force productions are increased. The daxis stator current controls suspension force and the q-axis current controls the developed torque of the motor. In the case when there is less number of slots in the machine, the actual suspension force cannot follow the command. In order to make the actual suspension force to follow the command a compensation method in also proposed in this paper. A simulation study is done for the proposed radial position control based integrated winding BELM using finite element analysis software.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128365913","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 34
Modeling and applications of three winding transformers in industrial and commercial facilities part 2: Unbalanced and transient analysis 工业和商业设施中三绕组变压器的建模和应用。第2部分:不平衡和暂态分析
2011 IEEE Industry Applications Society Annual Meeting Pub Date : 2011-11-10 DOI: 10.1109/IAS.2011.6074410
R. Rifaat
{"title":"Modeling and applications of three winding transformers in industrial and commercial facilities part 2: Unbalanced and transient analysis","authors":"R. Rifaat","doi":"10.1109/IAS.2011.6074410","DOIUrl":"https://doi.org/10.1109/IAS.2011.6074410","url":null,"abstract":"In a previous companion paper the usage and basic modeling of 3-winding transformers was discussed. This paper complements the first paper and covers the modeling for unbalanced and transient conditions that could also exist in industrial electrical systems. The modeling and presentation of 3-winding transformers is discussed in two parts. The first part discusses single and two phase-to-ground fault conditions and includes modeling of zero sequence impedances. The second part discusses modeling 3-winding transformers for harmonics, energization and voltage transients studies which require modeling in the Electromagnetic Transient Programs (EMTP). The importance of correct interpretation of 3W transformers parameters, correct selection of model and case studies are demonstrated for the subject conditions.","PeriodicalId":268988,"journal":{"name":"2011 IEEE Industry Applications Society Annual Meeting","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131063136","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信