Stain technology最新文献

筛选
英文 中文
A sensitive method to quantitate gangliosides of the gangliotetraose series directly on chromatograms using peroxidase conjugated cholera toxin. 用过氧化物酶结合霍乱毒素在色谱上直接定量神经节四糖系列神经节苷的灵敏方法。
Stain technology Pub Date : 1990-01-01 DOI: 10.3109/10520299009105620
L D Cambron, K C Leskawa
{"title":"A sensitive method to quantitate gangliosides of the gangliotetraose series directly on chromatograms using peroxidase conjugated cholera toxin.","authors":"L D Cambron,&nbsp;K C Leskawa","doi":"10.3109/10520299009105620","DOIUrl":"https://doi.org/10.3109/10520299009105620","url":null,"abstract":"<p><p>A method is described whereby ganglioside GM1 can be quantitated directly on thin-layer chromatograms using cholera toxin subunit B conjugated to horseradish peroxidase and visualized with chloronaphthol. Overlay and color development were performed after separating gangliosides on nano-TLC plates, and fixing with polyisobutylmethacrylate. Absolute quantitation was realized using a Shimadzu CS-9000 integrating spectrodensitometer, scanning at 580 nm. A correlation coefficient of 0.98 was obtained in a linear range of detection from 10(-11) to 10(-16) moles. Statistical analysis revealed good reproducibility and over 99% of the added gangliosides remained with the chromatogram during all overlay and washing procedures. By comparison, standard chemical visualization by resorcinol-HCl was linear in the nanomole range with a detection limit of only 10(-10) moles. Since the carbohydrate portion of gangliosides immobilized in this manner is susceptible to the action of enzymes including neuraminidase, this technique can be applied to all structures of the gangliotetraose series.</p>","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"65 6","pages":"293-7"},"PeriodicalIF":0.0,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520299009105620","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13236261","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
A new method for studying human oocytes by light and electron microscopy. 用光学显微镜和电子显微镜研究人类卵母细胞的新方法。
Stain technology Pub Date : 1989-11-01 DOI: 10.3109/10520298909107019
B M Wallace, T P Rollason, R S Sawers
{"title":"A new method for studying human oocytes by light and electron microscopy.","authors":"B M Wallace,&nbsp;T P Rollason,&nbsp;R S Sawers","doi":"10.3109/10520298909107019","DOIUrl":"https://doi.org/10.3109/10520298909107019","url":null,"abstract":"<p><p>Since ovarian follicles appear to be randomly oriented with respect to the plane of the section, the method of sectioning and examining follicles at their maximum diameter described here allows direct comparison between oocyte populations of women and small differences can be detected. Re-sectioning for EM allows selected follicles of interest to be examined at a higher resolution.</p>","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"64 6","pages":"281-8"},"PeriodicalIF":0.0,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520298909107019","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13631043","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Cerium-based demonstration of phosphatase activity in plastic-embedded sections: a comparison with conventional methods. 塑料包埋切片中磷酸酶活性的铈基演示:与常规方法的比较。
Stain technology Pub Date : 1989-11-01 DOI: 10.3109/10520298909107020
H van Goor, K Poelstra, M J Hardonk
{"title":"Cerium-based demonstration of phosphatase activity in plastic-embedded sections: a comparison with conventional methods.","authors":"H van Goor,&nbsp;K Poelstra,&nbsp;M J Hardonk","doi":"10.3109/10520298909107020","DOIUrl":"https://doi.org/10.3109/10520298909107020","url":null,"abstract":"<p><p>Cerium-based methods have been used for the demonstration of several phosphatases at alkaline, acid and neutral pH in low temperature acetone-fixed, plastic-embedded sections. At alkaline pH calcium is used as capturing agent and the precipitated calcium phosphate converted to cerium phosphate. At neutral and acid pH cerium is used directly as capturing agent. Cerium phosphate is subsequently visualized using the H2O2-DAB method. A comparison has been made with conventional calcium-cobalt and lead methods. It appeared that calcium-cobalt methods are more susceptible to improvement than lead methods.</p>","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"64 6","pages":"289-96"},"PeriodicalIF":0.0,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520298909107020","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13629506","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Adherence of LR white sections to glass slides for silver enhancement immunogold labeling. 将LR白色切片贴在载玻片上进行银增强免疫金标记。
Stain technology Pub Date : 1989-11-01 DOI: 10.3109/10520298909107021
M Slater
{"title":"Adherence of LR white sections to glass slides for silver enhancement immunogold labeling.","authors":"M Slater","doi":"10.3109/10520298909107021","DOIUrl":"https://doi.org/10.3109/10520298909107021","url":null,"abstract":"<p><p>A continuing problem in immunogold labeling of 1 microns LR White sections for light microscopy is the lack of adherence of the sections to the glass microscope slides during silver enhancement. A technique is described to overcome this problem using a 2% Formvar solution to coat the glass.</p>","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"64 6","pages":"297-9"},"PeriodicalIF":0.0,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520298909107021","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13629507","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Preparation and characterization of 4-acetamido-4'-isothiocyanostilbene-2,2'-disulfonic acid (SITS) and related stilbene disulfonates. 4-乙酰氨基-4′-异硫氰酸二苯乙烯-2,2′-二磺酸及其相关二磺酸盐的制备与表征
Stain technology Pub Date : 1989-11-01 DOI: 10.3109/10520298909107022
P Jakobsen, R W Horobin
{"title":"Preparation and characterization of 4-acetamido-4'-isothiocyanostilbene-2,2'-disulfonic acid (SITS) and related stilbene disulfonates.","authors":"P Jakobsen,&nbsp;R W Horobin","doi":"10.3109/10520298909107022","DOIUrl":"https://doi.org/10.3109/10520298909107022","url":null,"abstract":"<p><p>4-Acetamido-4'-isothiocyanostilbene-2,2'-disulfonic acid (SITS) and other 4,4'-stilbene-2,2'-disulfonate derivatives used as reagents in histochemistry and physiology have been prepared in their E isomeric form, and rearranged to the Z isomers by irradiation with visible light. Infrared, and 1H and 13C nuclear magnetic resonance spectra were recorded for these compounds, and used to establish the chemical structures. In particular, it was shown that the E-isomer of SITS decomposed in aqueous solution by hydrolysis of both the acetamido and isocyano groups yielding a diamine; disodium 4,4'-diisothiocyanatostilbene-2,2'-disulfonate (DIDS) also decomposed in solution, while disodium 4,4'-dinitrostilbene-2,2'-sulfonate (DNDS) rearranged from the E-isomer to the Z-isomer when solutions were kept unprotected from light. These results indicate that benchworkers should not be surprised when commercial samples of such stilbenes contain large amounts of various types of impurities.</p>","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"64 6","pages":"301-13"},"PeriodicalIF":0.0,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520298909107022","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13629508","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Demonstration of phenolic compounds in plant tissues by an osmium-iodide postfixation procedure. 用碘化锇后固定程序证明植物组织中的酚类化合物。
Stain technology Pub Date : 1989-11-01 DOI: 10.3109/10520298909107018
M Scalet, E Crivellato, F Mallardi
{"title":"Demonstration of phenolic compounds in plant tissues by an osmium-iodide postfixation procedure.","authors":"M Scalet,&nbsp;E Crivellato,&nbsp;F Mallardi","doi":"10.3109/10520298909107018","DOIUrl":"https://doi.org/10.3109/10520298909107018","url":null,"abstract":"<p><p>A simple procedure to stain phenols in plant tissues is described. Postfixation with an aqueous solution prepared by mixing 2 cc of 2% osmium tetroxide and 8 cc of 3% potassium iodide yields brilliant visualization of phenol-containing vacuoles in different tissues of plants (e.g., coffee, oak, tobacco and spruce) bearing high concentration of phenolic compounds. Areas bearing phenols become dark gray to black. Chemical experiments demonstrate that osmium-potassium iodide (Os-KI) mixture reacts rapidly with several naturally occurring plant phenols, developing black solutions from which black solids precipitate. Phenols containing omicron-dihydroxy groups react with Os-KI solution more rapidly than other structurally different phenols. Therefore, omicron-dihydroxy units in an aromatic ring seem to function as primary sites of reactivity with the osmium-iodide complexes.</p>","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"64 6","pages":"273-80"},"PeriodicalIF":0.0,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520298909107018","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13631042","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 38
A technique for fluorescence microscopy in semithin sections. 半薄切片荧光显微镜技术
Stain technology Pub Date : 1989-09-01 DOI: 10.3109/10520298909107009
J L Ojeda, M A Ros, J M Icardo
{"title":"A technique for fluorescence microscopy in semithin sections.","authors":"J L Ojeda,&nbsp;M A Ros,&nbsp;J M Icardo","doi":"10.3109/10520298909107009","DOIUrl":"https://doi.org/10.3109/10520298909107009","url":null,"abstract":"<p><p>We describe here a procedure to improve contrast and resolution in fluorescence microscopy of sectioned tissues. Tissue fragments were fixed in ethanol-glacial acetic acid, embedded in diethylene glycol distearate, and semithin sectioned. This method maintains tissue antigenicity while preserving the structure of cells and tissues. The thinness of the sections eliminates scattered and emitted light from tissue structures outside the plane of focus. The procedure is simple and quick, and works excellently with fluorescein-conjugated lectins and antibodies.</p>","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"64 5","pages":"243-8"},"PeriodicalIF":0.0,"publicationDate":"1989-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520298909107009","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13840752","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Acetyl sudan black: a nonexistent reagent? 乙酰苏丹黑:一种不存在的试剂?
Stain technology Pub Date : 1989-09-01 DOI: 10.3109/10520298909107013
R W Horobin, G B Proctor
{"title":"Acetyl sudan black: a nonexistent reagent?","authors":"R W Horobin,&nbsp;G B Proctor","doi":"10.3109/10520298909107013","DOIUrl":"https://doi.org/10.3109/10520298909107013","url":null,"abstract":"Acetyl Sudan black (AcSB) has been recommended as a readily prepared reagent which “appears to give less background staining and just as intense lipid staining as the untreated dye,” i.e. as nonacetylated Sudan black B (Lillie and Fullmer 1976).","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"64 5","pages":"257-8"},"PeriodicalIF":0.0,"publicationDate":"1989-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520298909107013","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13628990","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An improved cellophane method for in vitro germination of recalcitrant pollen. 一种改良的玻璃纸法在离体萌发顽固花粉。
Stain technology Pub Date : 1989-09-01 DOI: 10.3109/10520298909107005
M P Alexander, S Ganeshan
{"title":"An improved cellophane method for in vitro germination of recalcitrant pollen.","authors":"M P Alexander,&nbsp;S Ganeshan","doi":"10.3109/10520298909107005","DOIUrl":"https://doi.org/10.3109/10520298909107005","url":null,"abstract":"<p><p>The cellophane technique of La Cour and Faberge has been improved by the use of a booklet of filter paper. The booklet consists of seven squares of filter paper stapled together; the cellophane on which the pollen is germinated is placed between the two top leaves of the booklet and the whole soaked in a sucrose-based nutrient medium for 15 min. This arrangement keeps the cellophane flat as it absorbs medium. The top leaf of the booklet is then removed, the pollen dusted on it and the completed preparation closed in a plastic-wrapped Petri dish. The lower leaves of the booklet keep the cellophane moist for up to 24 hr. Proportions of pollen grains germinating are at least as high as in the hanging drop method; pollen of species that germinate poorly or not all in hanging drops do well in this technique. Because the pollen tubes adhere tightly to the cellophane, staining, observation, and studies of various sorts are facilitated.</p>","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"64 5","pages":"225-7"},"PeriodicalIF":0.0,"publicationDate":"1989-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520298909107005","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13774946","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 22
The application of Miller's elastic stain to glycol methacrylate tissue sections. 米勒弹性染色法在甲基丙烯酸乙二醇酯组织切片上的应用。
Stain technology Pub Date : 1989-09-01 DOI: 10.3109/10520298909107007
M D Castro
{"title":"The application of Miller's elastic stain to glycol methacrylate tissue sections.","authors":"M D Castro","doi":"10.3109/10520298909107007","DOIUrl":"https://doi.org/10.3109/10520298909107007","url":null,"abstract":"<p><p>The application of Miller's dilute elastic stain followed sequentially by Gill's III hematoxylin and a fast green counterstain produced a reliable and consistent method for differentially staining elastic fibers, nuclei, muscle and collagen in glycol methacrylate tissue sections. Evaluation of different methods of fixation and conditions of staining on animal tissue sections showed that elastic fibers in both perfusion and immersion fixed tissues can be intensely stained. The stability of Miller's elastic stain offers the potential of a commercially available histological stain reagent for coarse and fine elastic fibers in glycol methacrylate tissue sections.</p>","PeriodicalId":21924,"journal":{"name":"Stain technology","volume":"64 5","pages":"233-8"},"PeriodicalIF":0.0,"publicationDate":"1989-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10520298909107007","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13628988","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信