NMR in Biomedicine最新文献

筛选
英文 中文
Unfolding coil localized errors from an imperfect slice profile using a structured autocalibration matrix: An application to reduce outflow effects in cine bSSFP imaging. 利用结构化自动校准矩阵,从不完美的切片轮廓中展开线圈局部误差:应用于减少 cine bSSFP 成像中的外流效应。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-08-07 DOI: 10.1002/nbm.5223
Fadil Ali, Zhaohuan Zhang, Andres Saucedo, Ajin Joy, Vahid Ghodrati, Kim-Lien Nguyen, J Paul Finn, Mark Bydder
{"title":"Unfolding coil localized errors from an imperfect slice profile using a structured autocalibration matrix: An application to reduce outflow effects in cine bSSFP imaging.","authors":"Fadil Ali, Zhaohuan Zhang, Andres Saucedo, Ajin Joy, Vahid Ghodrati, Kim-Lien Nguyen, J Paul Finn, Mark Bydder","doi":"10.1002/nbm.5223","DOIUrl":"10.1002/nbm.5223","url":null,"abstract":"<p><strong>Purpose: </strong>Balanced steady-state free precession (bSSFP) imaging is susceptible to outflow effects where excited spins leaving the slice as part of the blood stream are misprojected back onto the imaging plane. Previous work proposed using slice-encoding steps to localize these outflow effects from corrupting the target slice, at the expense of prolonged scan time. This present study extends this idea by proposing a means of significantly reducing most of the outflowing signal from the imaged slice using a coil localization method that acquires a slice-encoded calibration scan in addition to the 2D data, without being nearly as time-demanding as our previous method. This coil localization method is titled UNfolding Coil Localized Errors from an imperfect slice profile using a Structured Autocalibration Matrix (UNCLE SAM).</p><p><strong>Methods: </strong>Retrospective and prospective evaluations were carried out. Both featured a 2D acquisition and a separate slice-encoded calibration of the center in-plane <math><mi>k</mi></math> -space lines across all desired slice-encoding steps.</p><p><strong>Results: </strong>Retrospective results featured a slice-by-slice comparison of the slice-encoded images with UNCLE SAM. UNCLE SAM's subtraction from the slice-encoded image was compared with a subtraction from the flow-corrupted 2D image, to demonstrate UNCLE SAM's capability to unfold outflowing spins. UNCLE SAM's comparison with slice encoding showed that UNCLE SAM was able to unfold up to 74% of what slice encoding achieved. Prospective results showed significant reduction in outflow effects with only a marginal increase in scan time from the 2D acquisition.</p><p><strong>Conclusions: </strong>We developed a method that effectively unfolds most outflowing spins from corrupting the target slice and does not require the explicit use of slice-encoding gradients. This development offers a method to reduce most outflow effects from the target slice within a clinically feasible scan duration compared with the fully sampled slice-encoding technique.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5223"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141902503","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Characterizing diffusion-controlled release of small-molecules using quantitative MRI in view of applications to orthopedic infection. 从骨科感染应用的角度,利用定量核磁共振成像鉴定小分子的扩散控制释放。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-10-02 DOI: 10.1002/nbm.5254
Greg Hong, Tina Khazaee, Santiago F Cobos, Spencer D Christiansen, Junmin Liu, Maria Drangova, David W Holdsworth
{"title":"Characterizing diffusion-controlled release of small-molecules using quantitative MRI in view of applications to orthopedic infection.","authors":"Greg Hong, Tina Khazaee, Santiago F Cobos, Spencer D Christiansen, Junmin Liu, Maria Drangova, David W Holdsworth","doi":"10.1002/nbm.5254","DOIUrl":"10.1002/nbm.5254","url":null,"abstract":"<p><p>Calcium sulfate is an established carrier for localized drug delivery, but a means to non-invasively measure drug release, which would improve our understanding of localized delivery, remains an unmet need. We aim to quantitatively estimate the diffusion-controlled release of small molecules loaded into a calcium sulfate carrier through a gadobutrol-based contrast agent, which acts as a surrogate small molecule. A central cylindrical core made of calcium sulfate, either alone or within a metal scaffold, is loaded with contrast agents that release into agar. Multi-echo scans are acquired at multiple time points over 4 weeks and processed into R2* and quantitative susceptibility mapping (QSM) maps. Mean R2* values are fit to a known drug delivery model, which are then compared with the decrease in core QSM. Fitting R2* measurements of calcium sulfate core while constraining constants to a drug release model results in an R<sup>2</sup>-value of 0.991, yielding a diffusion constant of 4.59 × 10<sup>-11</sup> m<sup>2</sup> s<sup>-1</sup>. Incorporating the carrier within a metal scaffold results in a slower release. QSM shows the resulting loss of susceptibility in the non-metal core but is unreliable around metal. R2* characterizes the released gadobutrol, and QSM detects the resulting decrease in core susceptibility. The addition of a porous metal scaffold slows the release of gadobutrol, as expected.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5254"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142365945","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Simultaneous whole-liver water T 1 and T 2 mapping with isotropic resolution during free-breathing. 在自由呼吸过程中以各向同性分辨率同时绘制全肝水 T 1 $$ {mathrm{T}}_1 $$ 和 T 2 $$ {mathrm{T}}_2 $$。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-08-04 DOI: 10.1002/nbm.5216
Jonathan Stelter, Kilian Weiss, Lisa Steinhelfer, Veronika Spieker, Elizabeth Huaroc Moquillaza, Weitong Zhang, Marcus R Makowski, Julia A Schnabel, Bernhard Kainz, Rickmer F Braren, Dimitrios C Karampinos
{"title":"<ArticleTitle xmlns:ns0=\"http://www.w3.org/1998/Math/MathML\">Simultaneous whole-liver water <ns0:math><ns0:msub><ns0:mtext>T</ns0:mtext> <ns0:mtext>1</ns0:mtext></ns0:msub> </ns0:math> and <ns0:math><ns0:msub><ns0:mtext>T</ns0:mtext> <ns0:mtext>2</ns0:mtext></ns0:msub> </ns0:math> mapping with isotropic resolution during free-breathing.","authors":"Jonathan Stelter, Kilian Weiss, Lisa Steinhelfer, Veronika Spieker, Elizabeth Huaroc Moquillaza, Weitong Zhang, Marcus R Makowski, Julia A Schnabel, Bernhard Kainz, Rickmer F Braren, Dimitrios C Karampinos","doi":"10.1002/nbm.5216","DOIUrl":"10.1002/nbm.5216","url":null,"abstract":"&lt;p&gt;&lt;strong&gt;Purpose: &lt;/strong&gt;To develop and validate a data acquisition scheme combined with a motion-resolved reconstruction and dictionary-matching-based parameter estimation to enable free-breathing isotropic resolution self-navigated whole-liver simultaneous water-specific &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;T&lt;/mtext&gt; &lt;mtext&gt;1&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; ( &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;wT&lt;/mtext&gt; &lt;mtext&gt;1&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; ) and &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;T&lt;/mtext&gt; &lt;mtext&gt;2&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; ( &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;wT&lt;/mtext&gt; &lt;mtext&gt;2&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; ) mapping for the characterization of diffuse and oncological liver diseases.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Methods: &lt;/strong&gt;The proposed data acquisition consists of a magnetization preparation pulse and a two-echo gradient echo readout with a radial stack-of-stars trajectory, repeated with different preparations to achieve different &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;T&lt;/mtext&gt; &lt;mtext&gt;1&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; and &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;T&lt;/mtext&gt; &lt;mtext&gt;2&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; contrasts in a fixed acquisition time of 6 min. Regularized reconstruction was performed using self-navigation to account for motion during the free-breathing acquisition, followed by water-fat separation. Bloch simulations of the sequence were applied to optimize the sequence timing for &lt;math&gt; &lt;msub&gt;&lt;mrow&gt;&lt;mi&gt;B&lt;/mi&gt;&lt;/mrow&gt; &lt;mrow&gt;&lt;mn&gt;1&lt;/mn&gt;&lt;/mrow&gt; &lt;/msub&gt; &lt;/math&gt; insensitivity at 3 T, to correct for relaxation-induced blurring, and to map &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;T&lt;/mtext&gt; &lt;mtext&gt;1&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; and &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;T&lt;/mtext&gt; &lt;mtext&gt;2&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; using a dictionary. The proposed method was validated on a water-fat phantom with varying relaxation properties and in 10 volunteers against imaging and spectroscopy reference values. The performance and robustness of the proposed method were evaluated in five patients with abdominal pathologies.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Results: &lt;/strong&gt;Simulations demonstrate good &lt;math&gt; &lt;msub&gt;&lt;mrow&gt;&lt;mi&gt;B&lt;/mi&gt;&lt;/mrow&gt; &lt;mrow&gt;&lt;mn&gt;1&lt;/mn&gt;&lt;/mrow&gt; &lt;/msub&gt; &lt;/math&gt; insensitivity of the proposed method in measuring &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;T&lt;/mtext&gt; &lt;mtext&gt;1&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; and &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;T&lt;/mtext&gt; &lt;mtext&gt;2&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; values. The proposed method produces co-registered &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;wT&lt;/mtext&gt; &lt;mtext&gt;1&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; and &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;wT&lt;/mtext&gt; &lt;mtext&gt;2&lt;/mtext&gt;&lt;/msub&gt; &lt;/math&gt; maps with a good agreement with reference methods (phantom: &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;wT&lt;/mtext&gt; &lt;mtext&gt;1&lt;/mtext&gt;&lt;/msub&gt; &lt;mo&gt;=&lt;/mo&gt; &lt;mn&gt;1&lt;/mn&gt; &lt;mo&gt;.&lt;/mo&gt; &lt;mn&gt;02&lt;/mn&gt; &lt;mspace&gt;&lt;/mspace&gt; &lt;msub&gt;&lt;mtext&gt;wT&lt;/mtext&gt; &lt;mtext&gt;1,ref&lt;/mtext&gt;&lt;/msub&gt; &lt;mo&gt;-&lt;/mo&gt; &lt;mn&gt;8&lt;/mn&gt; &lt;mo&gt;.&lt;/mo&gt; &lt;mn&gt;93&lt;/mn&gt; &lt;mspace&gt;&lt;/mspace&gt; &lt;mtext&gt;ms&lt;/mtext&gt; &lt;mo&gt;,&lt;/mo&gt; &lt;msup&gt;&lt;mi&gt;R&lt;/mi&gt; &lt;mn&gt;2&lt;/mn&gt;&lt;/msup&gt; &lt;mo&gt;=&lt;/mo&gt; &lt;mn&gt;0&lt;/mn&gt; &lt;mo&gt;.&lt;/mo&gt; &lt;mn&gt;991&lt;/mn&gt;&lt;/math&gt; ; &lt;math&gt;&lt;msub&gt;&lt;mtext&gt;wT&lt;/mtext&gt; &lt;mn&gt;2&lt;/mn&gt;&lt;/msub&gt; &lt;mo&gt;=&lt;/mo&gt; &lt;mn&gt;1&lt;/mn&gt; &lt;mo&gt;.&lt;/mo&gt; &lt;mn&gt;03&lt;/mn&gt; &lt;mspace&gt;&lt;/mspace&gt; &lt;msub&gt;&lt;mtext&gt;wT&lt;/mtext&gt; &lt;mtext&gt;2,ref&lt;/mtext&gt;&lt;/msub&gt; &lt;mo&gt;+&lt;/mo&gt; &lt;mn&gt;0&lt;/mn&gt; &lt;mo&gt;.&lt;/mo&gt; &lt;mn&gt;73&lt;/mn&gt; &lt;mspace&gt;&lt;/mspace&gt; &lt;mtext&gt;ms&lt;/mtext&gt; &lt;mo","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5216"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141889864","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Automatic deep learning segmentation of the hippocampus on high-resolution diffusion magnetic resonance imaging and its application to the healthy lifespan. 高分辨率弥散磁共振成像上的海马区自动深度学习分割及其在健康寿命中的应用。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-08-13 DOI: 10.1002/nbm.5227
Dylan Miller, Cory Efird, Kevin Grant Solar, Christian Beaulieu, Dana Cobzas
{"title":"Automatic deep learning segmentation of the hippocampus on high-resolution diffusion magnetic resonance imaging and its application to the healthy lifespan.","authors":"Dylan Miller, Cory Efird, Kevin Grant Solar, Christian Beaulieu, Dana Cobzas","doi":"10.1002/nbm.5227","DOIUrl":"10.1002/nbm.5227","url":null,"abstract":"<p><p>Diffusion tensor imaging (DTI) can provide unique contrast and insight into microstructural changes with age or disease of the hippocampus, although it is difficult to measure the hippocampus because of its comparatively small size, location, and shape. This has been markedly improved by the advent of a clinically feasible 1-mm isotropic resolution 6-min DTI protocol at 3 T of the hippocampus with limited brain coverage of 20 axial-oblique slices aligned along its long axis. However, manual segmentation is too laborious for large population studies, and it cannot be automatically segmented directly on the diffusion images using traditional T<sub>1</sub> or T<sub>2</sub> image-based methods because of the limited brain coverage and different contrast. An automatic method is proposed here that segments the hippocampus directly on high-resolution diffusion images based on an extension of well-known deep learning architectures like UNet and UNet++ by including additional dense residual connections. The method was trained on 100 healthy participants with previously performed manual segmentation on the 1-mm DTI, then evaluated on typical healthy participants (n = 53), yielding an excellent voxel overlap with a Dice score of ~ 0.90 with manual segmentation; notably, this was comparable with the inter-rater reliability of manually delineating the hippocampus on diffusion magnetic resonance imaging (MRI) (Dice score of 0.86). This method also generalized to a different DTI protocol with 36% fewer acquisitions. It was further validated by showing similar age trajectories of volumes, fractional anisotropy, and mean diffusivity from manual segmentations in one cohort (n = 153, age 5-74 years) with automatic segmentations from a second cohort without manual segmentations (n = 354, age 5-90 years). Automated high-resolution diffusion MRI segmentation of the hippocampus will facilitate large cohort analyses and, in future research, needs to be evaluated on patient groups.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5227"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141971581","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Identifying biochemical changes in the kidney using proton nuclear magnetic resonance in an adenine diet chronic kidney disease mouse model. 利用质子核磁共振识别腺嘌呤饮食慢性肾病小鼠模型中肾脏的生化变化。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-09-04 DOI: 10.1002/nbm.5257
Tyrone L R Humphries, Glenda C Gobe, Aaron J Urquhart, Robert J Ellis, Graham J Galloway, David A Vesey, Ross S Francis
{"title":"Identifying biochemical changes in the kidney using proton nuclear magnetic resonance in an adenine diet chronic kidney disease mouse model.","authors":"Tyrone L R Humphries, Glenda C Gobe, Aaron J Urquhart, Robert J Ellis, Graham J Galloway, David A Vesey, Ross S Francis","doi":"10.1002/nbm.5257","DOIUrl":"10.1002/nbm.5257","url":null,"abstract":"<p><p>This study aimed to investigate the metabolic changes in the kidneys in a murine adenine-diet model of chronic kidney disease (CKD). Kidney fibrosis is the common pathological manifestation across CKD aetiologies. Sustained inflammation and fibrosis cause changes in preferred energy metabolic pathways in the cells of the kidney. Kidney cortical tissue from mice receiving a control or adenine-supplemented diet for 8 weeks (late inflammation and fibrosis) and 12 weeks (8 weeks of treatment followed by 4 weeks recovery) were analysed by 2D-correlated nuclear magnetic resonance spectroscopy and compared with histopathology and biomarkers of kidney damage. Tissue metabolite and lipid levels were assessed using the MestreNova software. Expression of genes related to inflammation, fibrosis, and metabolism were measured using quantitative polymerase chain reaction. Animals showed indicators of severely impaired kidney function at 8 and 12 weeks. Significantly increased fibrosis was present at 8 weeks but not in the recovery group suggesting some reversal of fibrosis and amelioration of inflammation. At 8 weeks, metabolites associated with glycolysis were increased, while lipid signatures were decreased. Genes involved in fatty acid oxidation were decreased at 8 weeks but not 12 weeks while genes associated with glycolysis were significantly increased at 8 weeks but not at 12 weeks. In this murine model of CKD, kidney fibrosis was associated with the accumulation of triglyceride and free lactate. There was an up-regulation of glycolytic enzymes and down-regulation of lipolytic enzymes. These metabolic changes reflect the energy demands associated with progressive kidney disease where there is a switch from fatty acid oxidation to that of glycolysis.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5257"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142126284","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Reducing thermal noise in high-resolution quantitative magnetic resonance imaging rotating frame relaxation mapping of the human brain at 3 T. 降低 3 T 人脑高分辨率定量磁共振成像旋转帧弛豫映射中的热噪声。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-08-21 DOI: 10.1002/nbm.5228
Sara Ponticorvo, Antonietta Canna, Steen Moeller, Mehmet Akcakaya, Gregory J Metzger, Pavel Filip, Lynn E Eberly, Shalom Michaeli, Silvia Mangia
{"title":"Reducing thermal noise in high-resolution quantitative magnetic resonance imaging rotating frame relaxation mapping of the human brain at 3 T.","authors":"Sara Ponticorvo, Antonietta Canna, Steen Moeller, Mehmet Akcakaya, Gregory J Metzger, Pavel Filip, Lynn E Eberly, Shalom Michaeli, Silvia Mangia","doi":"10.1002/nbm.5228","DOIUrl":"10.1002/nbm.5228","url":null,"abstract":"<p><p>Quantitative maps of rotating frame relaxation (RFR) time constants are sensitive and useful magnetic resonance imaging tools with which to evaluate tissue integrity in vivo. However, to date, only moderate image resolutions of 1.6 x 1.6 x 3.6 mm<sup>3</sup> have been used for whole-brain coverage RFR mapping in humans at 3 T. For more precise morphometrical examinations, higher spatial resolutions are desirable. Towards achieving the long-term goal of increasing the spatial resolution of RFR mapping without increasing scan times, we explore the use of the recently introduced Transform domain NOise Reduction with DIstribution Corrected principal component analysis (T-NORDIC) algorithm for thermal noise reduction. RFR acquisitions at 3 T were obtained from eight healthy participants (seven males and one female) aged 52 ± 20 years, including adiabatic T1ρ, T2ρ, and nonadiabatic Relaxation Along a Fictitious Field (RAFF) in the rotating frame of rank n = 4 (RAFF4) with both 1.6 x 1.6 x 3.6 mm<sup>3</sup> and 1.25 x 1.25 x 2 mm<sup>3</sup> image resolutions. We compared RFR values and their confidence intervals (CIs) obtained from fitting the denoised versus nondenoised images, at both voxel and regional levels separately for each resolution and RFR metric. The comparison of metrics obtained from denoised versus nondenoised images was performed with a two-sample paired t-test and statistical significance was set at p less than 0.05 after Bonferroni correction for multiple comparisons. The use of T-NORDIC on the RFR images prior to the fitting procedure decreases the uncertainty of parameter estimation (lower CIs) at both spatial resolutions. The effect was particularly prominent at high-spatial resolution for RAFF4. Moreover, T-NORDIC did not degrade map quality, and it had minimal impact on the RFR values. Denoising RFR images with T-NORDIC improves parameter estimation while preserving the image quality and accuracy of all RFR maps, ultimately enabling high-resolution RFR mapping in scan times that are suitable for clinical settings.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5228"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11650668/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142018171","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Significant age-related differences between lower leg muscles of older and younger female subjects detected by ultrashort echo time magnetization transfer modeling. 通过超短回波时间磁化转移建模检测老年女性和年轻女性小腿肌肉之间与年龄有关的显著差异。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-08-18 DOI: 10.1002/nbm.5237
Saeed Jerban, Hamidreza Shaterian Mohammadi, Jiyo S Athertya, Amir Masoud Afsahi, Niloofar Shojaeiadib, Dina Moazamian, Samuel R Ward, Gina Woods, Christine B Chung, Jiang Du, Eric Y Chang
{"title":"Significant age-related differences between lower leg muscles of older and younger female subjects detected by ultrashort echo time magnetization transfer modeling.","authors":"Saeed Jerban, Hamidreza Shaterian Mohammadi, Jiyo S Athertya, Amir Masoud Afsahi, Niloofar Shojaeiadib, Dina Moazamian, Samuel R Ward, Gina Woods, Christine B Chung, Jiang Du, Eric Y Chang","doi":"10.1002/nbm.5237","DOIUrl":"10.1002/nbm.5237","url":null,"abstract":"<p><p>Magnetization transfer (MT) magnetic resonance imaging (MRI) can be used to estimate the fraction of water and macromolecular proton pools in tissues. MT modeling paired with ultrashort echo time acquisition (UTE-MT modeling) has been proposed to improve the evaluation of the myotendinous junction and fibrosis in muscle tissues, which the latter increases with aging. This study aimed to determine if the UTE-MT modeling technique is sensitive to age-related changes in the skeletal muscles of the lower leg. Institutional review board approval was obtained, and all recruited subjects provided written informed consent. The legs of 31 healthy younger (28.1 ± 6.1 years old, BMI = 22.3 ± 3.5) and 20 older (74.7 ± 5.5 years old, BMI = 26.7 ± 5.9) female subjects were imaged using UTE sequences on a 3 T MRI scanner. MT ratio (MTR), macromolecular fraction (MMF), macromolecular T2 (T2-MM), and water T2 (T2-W) were calculated using UTE-MT modeling for the anterior tibialis (ATM), posterior tibialis (PTM), soleus (SM), and combined lateral muscles. Results were compared between groups using the Wilcoxon rank sum test. Three independent observers selected regions of interest (ROIs) and processed UTE-MRI images separately, and the intraclass correlation coefficient (ICC) was calculated for a reproducibility study. Significantly lower mean MTR and MMF values were present in the older compared with the younger group in all studied lower leg muscles. T2-MM showed significantly lower values in the older group only for PTM and SM muscles. In contrast, T2-W showed significantly higher values in the older group. The age-related differences were more pronounced for MMF (-17 to -19%) and T2-W (+20 to 47%) measurements in all muscle groups compared with other investigated MR measures. ICCs were higher than 0.93, indicating excellent consistency between the ROI selection and MRI measurements of independent readers. As demonstrated by significant differences between younger and older groups, this research emphasizes the potential of UTE-MT MRI techniques in evaluating age-related skeletal muscle changes.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5237"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11786624/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142000466","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Accelerated 2D radial Look-Locker T1 mapping using a deep learning-based rapid inversion recovery sampling technique. 利用基于深度学习的快速反演恢复采样技术加速二维径向 Look-Locker T1 绘图。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-10-02 DOI: 10.1002/nbm.5266
Eze Ahanonu, Ute Goerke, Kevin Johnson, Brian Toner, Diego R Martin, Vibhas Deshpande, Ali Bilgin, Maria Altbach
{"title":"Accelerated 2D radial Look-Locker T1 mapping using a deep learning-based rapid inversion recovery sampling technique.","authors":"Eze Ahanonu, Ute Goerke, Kevin Johnson, Brian Toner, Diego R Martin, Vibhas Deshpande, Ali Bilgin, Maria Altbach","doi":"10.1002/nbm.5266","DOIUrl":"10.1002/nbm.5266","url":null,"abstract":"<p><p>Efficient abdominal coverage with T1-mapping methods currently available in the clinic is limited by the breath hold period (BHP) and the time needed for T1 recovery. This work develops a T1-mapping framework for efficient abdominal coverage based on rapid T1 recovery curve (T1RC) sampling, slice-selective inversion, optimized slice interleaving, and a convolutional neural network (CNN)-based T1 estimation. The effect of reducing the T1RC sampling was evaluated by comparing T1 estimates from T1RC ranging from 0.63 to 2.0 s with reference T1 values obtained from T1RC = 2.5-5 s. Slice interleaving methodologies were evaluated by comparing the T1 variation in abdominal organs across slices. The repeatability of the proposed framework was demonstrated by performing acquisition on test subjects across imaging sessions. Analysis of in vivo data based on retrospectively shortening the T1RC showed that with the CNN framework, a T1RC = 0.84 s yielded T1 estimates without significant changes in mean T1 (p > 0.05) or significant increase in T1 variability (p > 0.48) compared to the reference. Prospectively acquired data using T1RC = 0.84 s, an optimized slice interleaving scheme, and the CNN framework enabled 21 slices in a 20 s BHP. Analyses across abdominal organs produced T1 values within 2% of the reference. Repeatability experiments yielded Pearson's correlation, repeatability coefficient, and coefficient of variation of 0.99, 2.5%, and 0.12%, respectively. The proposed T1 mapping framework provides full abdominal coverage within a single BHP.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5266"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11892465/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142365944","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Single-shot multi-b-value (SSMb) diffusion-weighted MRI using spin echo and stimulated echoes with variable flip angles. 使用自旋回波和可变翻转角刺激回波的单次多 b 值(SSMb)扩散加权磁共振成像。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-09-22 DOI: 10.1002/nbm.5261
Guangyu Dan, Kaibao Sun, Qingfei Luo, Xiaohong Joe Zhou
{"title":"Single-shot multi-b-value (SSMb) diffusion-weighted MRI using spin echo and stimulated echoes with variable flip angles.","authors":"Guangyu Dan, Kaibao Sun, Qingfei Luo, Xiaohong Joe Zhou","doi":"10.1002/nbm.5261","DOIUrl":"10.1002/nbm.5261","url":null,"abstract":"<p><p>Conventional diffusion-weighted imaging (DWI) sequences employing a spin echo or stimulated echo sensitize diffusion with a specific b-value at a fixed diffusion direction and diffusion time (Δ). To compute apparent diffusion coefficient (ADC) and other diffusion parameters, the sequence needs to be repeated multiple times by varying the b-value and/or gradient direction. In this study, we developed a single-shot multi-b-value (SSMb) diffusion MRI technique, which combines a spin echo and a train of stimulated echoes produced with variable flip angles. The method involves a pair of 90° radio frequency (RF) pulses that straddle a diffusion gradient lobe (G<sub>D</sub>), to rephase the magnetization in the transverse plane, producing a diffusion-weighted spin echo acquired by the first echo-planar imaging (EPI) readout train. The magnetization stored along the longitudinal axis is successively re-excited by a series of n variable-flip-angle pulses, each followed by a diffusion gradient lobe G<sub>D</sub> and a subsequent EPI readout train to sample n stimulated-echo signals. As such, (n + 1) diffusion-weighted images, each with a distinct b-value, are acquired in a single shot. The SSMb sequence was demonstrated on a diffusion phantom and healthy human brain to produce diffusion-weighted images, which were quantitative analyzed using a mono-exponential model. In the phantom experiment, SSMb provided similar ADC values to those from a commercial spin-echo EPI (SE-EPI) sequence (r = 0.999). In the human brain experiment, SSMb enabled a fourfold scan time reduction and yielded slightly lower ADC values (0.83 ± 0.26 μm<sup>2</sup>/ms) than SE-EPI (0.88 ± 0.29 μm<sup>2</sup>/ms) in all voxels excluding cerebrospinal fluid, likely due to the influence of varying diffusion times. The feasibility of using SSMb to acquire multiple images in a single shot for intravoxel incoherent motion (IVIM) analysis was also demonstrated. In conclusion, despite a relatively low signal-to-noise ratio, the proposed SSMb technique can substantially increase the data acquisition efficiency in DWI studies.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5261"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142292261","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Elliptical Halbach magnet and gradient modules for low-field portable magnetic resonance imaging. 用于低场便携式磁共振成像的椭圆形哈尔巴赫磁体和梯度模块。
IF 2.7 4区 医学
NMR in Biomedicine Pub Date : 2024-12-01 Epub Date: 2024-09-30 DOI: 10.1002/nbm.5258
Fernando Galve, Eduardo Pallás, Teresa Guallart-Naval, Pablo García-Cristóbal, Pablo Martínez, José M Algarín, Jose Borreguero, Rubén Bosch, Francisco Juan-Lloris, José M Benlloch, Joseba Alonso
{"title":"Elliptical Halbach magnet and gradient modules for low-field portable magnetic resonance imaging.","authors":"Fernando Galve, Eduardo Pallás, Teresa Guallart-Naval, Pablo García-Cristóbal, Pablo Martínez, José M Algarín, Jose Borreguero, Rubén Bosch, Francisco Juan-Lloris, José M Benlloch, Joseba Alonso","doi":"10.1002/nbm.5258","DOIUrl":"10.1002/nbm.5258","url":null,"abstract":"<p><p>This study aims to develop methods to design the complete magnetic system for a truly portable MRI scanner for neurological and musculoskeletal (MSK) applications, optimized for field homogeneity, field of view (FoV), and gradient performance compared to existing low-weight configurations. We explore optimal elliptic-bore Halbach configurations based on discrete arrays of permanent magnets. In this way, we seek to improve the field homogeneity and remove constraints to the extent of the gradient coils typical of Halbach magnets. Specifically, we have optimized a tightly packed distribution of magnetic Nd<sub>2</sub>Fe<sub>14</sub>B cubes with differential evolution algorithms and a second array of shimming magnets with interior point and differential evolution methods. We have also designed and constructed an elliptical set of gradient coils that extend over the whole magnet length, maximizing the distance between the lobe centers. These are optimized with a target field method minimizing a cost function that considers also heat dissipation. We have employed the new toolbox to build the main magnet and gradient modules for a portable MRI scanner designed for point-of-care and residential use. The elliptical Halbach bore has semi-axes of 10 and 14& cm, and the magnet generates a field of 87& mT homogeneous down to 5700& ppm (parts per million) in a 20-cm diameter FoV; it weighs 216& kg and has a width of 65& cm and a height of 72& cm. Gradient efficiencies go up to around 0.8& mT/m/A, for a maximum of 12& mT/m within 0.5& ms with 15& A and 15& V amplifier. The distance between lobes is 28& cm, significantly increased with respect to other Halbach-based scanners. Heat dissipation is around 25& W at maximum power, and gradient deviations from linearity are below 20% in a 20-cm sphere. Elliptic-bore Halbach magnets enhance the ergonomicity and field distribution of low-cost portable MRI scanners, while allowing for full-length gradient support to increase the FoV. This geometry can be potentially adapted for a prospective low-cost whole-body technology.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5258"},"PeriodicalIF":2.7,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142350984","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信