Journal of Research of the National Institute of Standards and Technology最新文献

筛选
英文 中文
Assessing Differences Between Results Determined According to the Guide to the Expression of Uncertainty in Measurement. 评估根据《测量不确定性表达指南》确定的结果之间的差异。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-12-01 Print Date: 2010-11-01 DOI: 10.6028/jres.115.031
Raghu N Kacker, Rüdiger Kessel, Klaus-Dieter Sommer
{"title":"Assessing Differences Between Results Determined According to the Guide to the Expression of Uncertainty in Measurement.","authors":"Raghu N Kacker, Rüdiger Kessel, Klaus-Dieter Sommer","doi":"10.6028/jres.115.031","DOIUrl":"10.6028/jres.115.031","url":null,"abstract":"<p><p>In some metrology applications multiple results of measurement for a common measurand are obtained and it is necessary to determine whether the results agree with each other. A result of measurement based on the Guide to the Expression of Uncertainty in Measurement (GUM) consists of a measured value together with its associated standard uncertainty. In the GUM, the measured value is regarded as the expected value and the standard uncertainty is regarded as the standard deviation, both known values, of a state-of-knowledge probability distribution. A state-of-knowledge distribution represented by a result need not be completely known. Then how can one assess the differences between the results based on the GUM? Metrologists have for many years used the Birge chisquare test as 'a rule of thumb' to assess the differences between two or more measured values for the same measurand by pretending that the standard uncertainties were the standard deviations of the presumed sampling probability distributions from random variation of the measured values. We point out that this is misuse of the standard uncertainties; the Birge test and the concept of statistical consistency motivated by it do not apply to the results of measurement based on the GUM. In 2008, the International Vocabulary of Metrology, third edition (VIM3) introduced the concept of metrological compatibility. We propose that the concept of metrological compatibility be used to assess the differences between results based on the GUM for the same measurand. A test of the metrological compatibility of two results of measurement does not conflict with a pairwise Birge test of the statistical consistency of the corresponding measured values.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548867/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34446153","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Overlap-Based Cell Tracker. 基于重叠的细胞跟踪器。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-12-01 Print Date: 2010-11-01 DOI: 10.6028/jres.115.034
Joe Chalfoun, Antonio Cardone, Alden A Dima, Daniel P Allen, Michael W Halter
{"title":"Overlap-Based Cell Tracker.","authors":"Joe Chalfoun,&nbsp;Antonio Cardone,&nbsp;Alden A Dima,&nbsp;Daniel P Allen,&nbsp;Michael W Halter","doi":"10.6028/jres.115.034","DOIUrl":"https://doi.org/10.6028/jres.115.034","url":null,"abstract":"<p><p>In order to facilitate the extraction of quantitative data from live cell image sets, automated image analysis methods are needed. This paper presents an introduction to the general principle of an overlap cell tracking software developed by the National Institute of Standards and Technology (NIST). This cell tracker has the ability to track cells across a set of time lapse images acquired at high rates based on the amount of overlap between cellular regions in consecutive frames. It is designed to be highly flexible, requires little user parameterization, and has a fast execution time.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548870/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34446149","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
An Optical Frequency Comb Tied to GPS for Laser Frequency/Wavelength Calibration. 用于激光频率/波长校准的GPS光学频率梳。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-12-01 Print Date: 2010-11-01 DOI: 10.6028/jres.115.028
Jack A Stone, Patrick Egan
{"title":"An Optical Frequency Comb Tied to GPS for Laser Frequency/Wavelength Calibration.","authors":"Jack A Stone,&nbsp;Patrick Egan","doi":"10.6028/jres.115.028","DOIUrl":"https://doi.org/10.6028/jres.115.028","url":null,"abstract":"<p><p>Optical frequency combs can be employed over a broad spectral range to calibrate laser frequency or vacuum wavelength. This article describes procedures and techniques utilized in the Precision Engineering Division of NIST (National Institute of Standards and Technology) for comb-based calibration of laser wavelength, including a discussion of ancillary measurements such as determining the mode order. The underlying purpose of these calibrations is to provide traceable standards in support of length measurement. The relative uncertainty needed to fulfill this goal is typically 10(-8) and never below 10(-12), very modest requirements compared to the capabilities of comb-based frequency metrology. In this accuracy range the Global Positioning System (GPS) serves as an excellent frequency reference that can provide the traceable underpinning of the measurement. This article describes techniques that can be used to completely characterize measurement errors in a GPS-based comb system and thus achieve full confidence in measurement results.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548864/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34444662","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
A Review of Fatigue Crack Growth for Pipeline Steels Exposed to Hydrogen. 管道钢氢暴露疲劳裂纹扩展研究进展。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-12-01 Print Date: 2010-11-01 DOI: 10.6028/jres.115.030
N Nanninga, A Slifka, Y Levy, C White
{"title":"A Review of Fatigue Crack Growth for Pipeline Steels Exposed to Hydrogen.","authors":"N Nanninga,&nbsp;A Slifka,&nbsp;Y Levy,&nbsp;C White","doi":"10.6028/jres.115.030","DOIUrl":"https://doi.org/10.6028/jres.115.030","url":null,"abstract":"<p><p>Hydrogen pipeline systems offer an economical means of storing and transporting energy in the form of hydrogen gas. Pipelines can be used to transport hydrogen that has been generated at solar and wind farms to and from salt cavern storage locations. In addition, pipeline transportation systems will be essential before widespread hydrogen fuel cell vehicle technology becomes a reality. Since hydrogen pipeline use is expected to grow, the mechanical integrity of these pipelines will need to be validated under the presence of pressurized hydrogen. This paper focuses on a review of the fatigue crack growth response of pipeline steels when exposed to gaseous hydrogen environments. Because of defect-tolerant design principles in pipeline structures, it is essential that designers consider hydrogen-assisted fatigue crack growth behavior in these applications.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.6028/jres.115.030","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34446151","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 72
A Gas Pressure Scale Based on Primary Standard Piston Gauges. 一种基于初级标准活塞压力表的气体压力刻度。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-12-01 Print Date: 2010-11-01 DOI: 10.6028/jres.115.027
Douglas A Olson, R Greg Driver, Walter J Bowers
{"title":"A Gas Pressure Scale Based on Primary Standard Piston Gauges.","authors":"Douglas A Olson,&nbsp;R Greg Driver,&nbsp;Walter J Bowers","doi":"10.6028/jres.115.027","DOIUrl":"https://doi.org/10.6028/jres.115.027","url":null,"abstract":"<p><p>The National Institute of Standards and Technology (NIST) has redefined its gas pressure scale, up to 17 MPa, based on two primary standard piston gauges. The primary standard piston gauges are 35.8 mm in diameter and operate from 20 kPa to 1 MPa. Ten secondary standard piston gauges, two each of five series of the Ruska 2465 type, with successively smaller diameters form the scale extending up to 17 MPa. Six of the piston gauges were directly compared to the primary standards to determine their effective area and expanded (k = 2) uncertainty. Two piston gauges operating to 7 MPa were compared to the 1.4 MPa gauges, and two piston gauges operating to 17 MPa were compared to the 7 MPa gauges. Distortion in the 7 MPa piston gauges was determined by comparing those gauges to a DH Instruments PG7601 type piston gauge, whose distortion was calculated using elasticity theory. The relative standard uncertainties achieved by the primary standards range from 3.0 × 10(-6) to 3.2 × 10(-6). The relative standard uncertainty of the secondary standards is as low as 4.2 × 10(-6) at 300 kPa. The effective areas and uncertainties were validated by comparison to standards of other National Metrology Institutes (NMIs). Results show agreement in all cases to better than the expanded (k = 2) uncertainty of the difference between NIST and the other NMIs, and in most cases to better than the standard (k = 1) uncertainty of the difference.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548863/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34444661","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Optical Fiber Power Meter Comparison Between NIST and NIM. NIST与NIM光纤功率计之比较。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-12-01 Print Date: 2010-11-01 DOI: 10.6028/jres.115.029
I Vayshenker, D J Livigni, X Li, J H Lehman, J Li, L M Xiong, Z X Zhang
{"title":"Optical Fiber Power Meter Comparison Between NIST and NIM.","authors":"I Vayshenker,&nbsp;D J Livigni,&nbsp;X Li,&nbsp;J H Lehman,&nbsp;J Li,&nbsp;L M Xiong,&nbsp;Z X Zhang","doi":"10.6028/jres.115.029","DOIUrl":"https://doi.org/10.6028/jres.115.029","url":null,"abstract":"<p><p>We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and National Institute of Metrology (NIM-China). We report optical fiber-based power measurements at nominal wavelengths of 1310 nm and 1550 nm. We compare the laboratories' reference standards by means of a commercial optical power meter. Measurement results showed the largest difference of less than 2.6 parts in 10(3), which is within the combined standard (k = 1) uncertainty for the laboratories' reference standards.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548865/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34444663","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Variances of Plane Parameters Fitted to Range Data. 拟合距离数据的平面参数方差。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-12-01 Print Date: 2010-11-01 DOI: 10.6028/jres.115.032
Marek Franaszek
{"title":"Variances of Plane Parameters Fitted to Range Data.","authors":"Marek Franaszek","doi":"10.6028/jres.115.032","DOIUrl":"https://doi.org/10.6028/jres.115.032","url":null,"abstract":"<p><p>Formulas for variances of plane parameters fitted with Nonlinear Least Squares to point clouds acquired by 3D imaging systems (e.g., LADAR) are derived. Two different error objective functions used in minimization are discussed: the orthogonal and the directional functions. Comparisons of corresponding formulas suggest the two functions can yield different results when applied to the same dataset.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548868/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34446147","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Acid Neutralization Capacity of a Tricalcium Silicate-Containing Calcium Phosphate Cement as an Endodontic Material. 含硅酸三钙磷酸钙水泥作为牙髓材料的酸中和能力。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-12-01 Print Date: 2010-11-01 DOI: 10.6028/jres.115.033
A Maria Cherng, Shozo Takagi, Laurence C Chow
{"title":"Acid Neutralization Capacity of a Tricalcium Silicate-Containing Calcium Phosphate Cement as an Endodontic Material.","authors":"A Maria Cherng,&nbsp;Shozo Takagi,&nbsp;Laurence C Chow","doi":"10.6028/jres.115.033","DOIUrl":"https://doi.org/10.6028/jres.115.033","url":null,"abstract":"<p><p>A calcium phosphate cement (CPC) was shown to have the necessary attributes for endodontic materials except adequate basicity needed for antimicrobial properties. To enhance its basicity, tricalcium silicate (Ca3SiO5), a highly alkaline compound, was added to CPC at a mass fraction of 0.25, 0.5 or 0.75. The basicity, acid neutralization and physical properties of the CPC-Ca3SiO5 composites were investigated. Mineral trioxide aggregate (MTA) was used as the control. The acid neutralizing capacity of the CPC-Ca3SiO5 composites and MTA were measured by titrating the suspensions of ground set samples with a 0.2 mol / L HCl at predetermined pH levels, i.e., 11, 9.0, and 7.4. The setting time of CPC-Ca3SiO5 composites determined by the Gilmore needle method was 40 ± 10 min. Acid neutralizing capacity of CPC depended (p < 0.05) on Ca3SiO5 content. CPC containing 75 % Ca3SiO5 could neutralize slightly less acid than MTA (p < 0.05), but it had a shorter setting time than that of MTA (> 4 h) and excellent handling properties.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548869/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34446150","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
MEMS Young's Modulus and Step Height Measurements With Round Robin Results. 基于循环结果的MEMS杨氏模量和阶跃高度测量。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-10-01 Print Date: 2010-09-01 DOI: 10.6028/jres.115.023
Janet Marshall, Richard A Allen, Craig D McGray, Jon Geist
{"title":"MEMS Young's Modulus and Step Height Measurements With Round Robin Results.","authors":"Janet Marshall,&nbsp;Richard A Allen,&nbsp;Craig D McGray,&nbsp;Jon Geist","doi":"10.6028/jres.115.023","DOIUrl":"https://doi.org/10.6028/jres.115.023","url":null,"abstract":"<p><p>This paper presents the results of a microelectromechanical systems (MEMS) Young's modulus and step height round robin experiment, completed in April 2009, which compares Young's modulus and step height measurement results at a number of laboratories. The purpose of the round robin was to provide data for the precision and bias statements of two related Semiconductor Equipment and Materials International (SEMI) standard test methods for MEMS. The technical basis for the test methods on Young's modulus and step height measurements are also provided in this paper. Using the same test method, the goal of the round robin was to assess the repeatability of measurements at one laboratory, by the same operator, with the same equipment, in the shortest practical period of time as well as the reproducibility of measurements with independent data sets from unique combinations of measurement setups and researchers. Both the repeatability and reproducibility measurements were done on random test structures made of the same homogeneous material. The average repeatability Young's modulus value (as obtained from resonating oxide cantilevers) was 64.2 GPa with 95 % limits of ± 10.3 % and an average combined standard uncertainty value of 3.1 GPa. The average reproducibility Young's modulus value was 62.8 GPa with 95 % limits of ± 11.0 % and an average combined standard uncertainty value of 3.0 GPa. The average repeatability step height value (for a metal2-over-poly1 step from active area to field oxide) was 0.477 μm with 95 % limits of 7.9 % and an average combined standard uncertainty value of 0.014 μm. The average reproducibility step height value was 0.481 μm with 95 % limits of ± 6.2 % and an average combined standard uncertainty value of 0.014 μm. In summary, this paper demonstrates that a reliable methodology can be used to measure Young's modulus and step height. Furthermore, a micro and nano technology (MNT) 5-in-1 standard reference material (SRM) can be used by industry to compare their in-house measurements using this methodology with NIST measurements thereby validating their use of the documentary standards.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548872/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34444658","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Evaluation of the Propensity of Niobium to Absorb Hydrogen During Fabrication of Superconducting Radio Frequency Cavities for Particle Accelerators. 粒子加速器超导射频腔制备过程中铌吸氢倾向的评价。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2010-10-01 Print Date: 2010-09-01 DOI: 10.6028/jres.115.025
R E Ricker, G R Myneni
{"title":"Evaluation of the Propensity of Niobium to Absorb Hydrogen During Fabrication of Superconducting Radio Frequency Cavities for Particle Accelerators.","authors":"R E Ricker,&nbsp;G R Myneni","doi":"10.6028/jres.115.025","DOIUrl":"https://doi.org/10.6028/jres.115.025","url":null,"abstract":"<p><p>During the fabrication of niobium superconducting radio frequency (SRF) particle accelerator cavities procedures are used that chemically or mechanically remove the passivating surface film of niobium pentoxide (Nb2O5). Removal of this film will expose the underlying niobium metal and allow it to react with the processing environment. If these reactions produce hydrogen at sufficient concentrations and rates, then hydrogen will be absorbed and diffuse into the metal. High hydrogen activities could result in supersaturation and the nucleation of hydride phases. If the metal repassivates at the conclusion of the processing step and the passive film blocks hydrogen egress, then the absorbed hydrogen or hydrides could be retained and alter the performance of the metal during subsequent processing steps or in-service. This report examines the feasibility of this hypothesis by first identifying the postulated events, conditions, and reactions and then determining if each is consistent with accepted scientific principles, literature, and data. Established precedent for similar events in other systems was found in the scientific literature and thermodynamic analysis found that the postulated reactions were not only energetically favorable, but produced large driving forces. The hydrogen activity or fugacity required for the reactions to be at equilibrium was determined to indicate the propensity for hydrogen evolution, absorption, and hydride nucleation. The influence of processing conditions and kinetics on the proximity of hydrogen surface coverage to these theoretical values is discussed. This examination found that the hypothesis of hydrogen absorption during SRF processing is consistent with published scientific literature and thermodynamic principles.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548874/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34444659","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 30
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信