Journal of Analytical Methods in Chemistry最新文献

筛选
英文 中文
Firing-Associated Recycling of Coal-Fired Power Plant Fly Ash. 燃煤电厂飞灰的伴燃回收。
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2023-01-01 DOI: 10.1155/2023/8597376
Vu Thi Ngoc Minh, Vuong-Hung Pham, Vu Hoang Tung, Cao Tho Tung, Nguyen Thi Hong Phuong
{"title":"Firing-Associated Recycling of Coal-Fired Power Plant Fly Ash.","authors":"Vu Thi Ngoc Minh,&nbsp;Vuong-Hung Pham,&nbsp;Vu Hoang Tung,&nbsp;Cao Tho Tung,&nbsp;Nguyen Thi Hong Phuong","doi":"10.1155/2023/8597376","DOIUrl":"https://doi.org/10.1155/2023/8597376","url":null,"abstract":"<p><p>Coal-fired power plant fly ash is a global environmental concern due to its small particle size, heavy metal content, and increased emissions. Although widely used in concrete, geopolymer, and fly ash brick production, a large amount of fly ash remains in storage sites or is used in landfills due to inadequate raw material quality, resulting in a waste of a recoverable resource. Therefore, the ongoing need is to develop new methods for recycling fly ash. The present review differentiates the physiochemical properties of fly ash from two coal combustion processes: fluidized bed combustion and pulverized coal combustion. It then discusses applications that can consume fly ash without strict chemical requirements, focusing on firing-associated methods. Finally, the challenges and opportunities of fly ash recycling are discussed.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"2023 ","pages":"8597376"},"PeriodicalIF":2.6,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9988373/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9084102","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Identification and Determination of Impurities in a New Therapeutic Agent for Fatty Liver Disease. 一种新型脂肪肝治疗剂中杂质的鉴定与测定。
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2023-01-01 DOI: 10.1155/2023/3116223
Huihui Shao, Jing Feng, Hanyilan Zhang, Yuanyuan Zhang, Tong Qin, Yuhua Hu, Wenxuan Zhang, Tiesong Wang, Song Wu, Qingyun Yang
{"title":"Identification and Determination of Impurities in a New Therapeutic Agent for Fatty Liver Disease.","authors":"Huihui Shao,&nbsp;Jing Feng,&nbsp;Hanyilan Zhang,&nbsp;Yuanyuan Zhang,&nbsp;Tong Qin,&nbsp;Yuhua Hu,&nbsp;Wenxuan Zhang,&nbsp;Tiesong Wang,&nbsp;Song Wu,&nbsp;Qingyun Yang","doi":"10.1155/2023/3116223","DOIUrl":"https://doi.org/10.1155/2023/3116223","url":null,"abstract":"<p><p>Methyl 7,7'-dimethoxy-5'-(morpholinomethyl)-[4,4'-bibenzo[d][1,3] dioxole]-5-carboxylate methanesulfonate (IMM) is an innovative drug for the treatment of nonalcoholic fatty liver disease (NAFLD) owing to its high efficacy and low toxicity. In this study, five minor impurities (I, II, III, IV, and V) were identified and analyzed using spectroscopic evidence, chemical synthetic methods, and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The impurities included hydrolysates and oxidation by-products extracted from both the drug in its final formulation and during synthesis. Toxicity prediction revealed potential carcinogenicity of impurity V containing an N-oxygen fragment. A reliable and selective HPLC method for the quantitative analysis of impurities I-IV and a sensitive HPLC-MS/MS method for potential genotoxic impurity V were developed and optimized. The methods were validated based on the International Council for Harmonization guidelines. Satisfactory linearity was obtained for the analytes over the range of 0.1-2.0 <i>μ</i>g/mL for impurities I-IV and 0.3-30.0 ng/mL for impurity V, and in all cases, the fitting correlation coefficients exceeded 0.999. The obtained limits of detection values were 0.05 ng/mL and 0.005 <i>μ</i>g/mL for impurity V and impurities I-IV, respectively. The precision and repeatability of the methods were less than 1.08% and 8.72% for each impurity. The recovery percentages of all impurities were in the range of 91.18%-111.27%, with the relative standard deviation of less than 3.69%. The greenness assessment of the HPLC method and the HPLC-MS/MS method were evaluated by using AGREE software with a score value of 0.72 and 0.68, respectively. The recommended procedures that were accurate, specific, and ecofriendly were applied to the existing active pharmaceutical ingredients of IMM, and they generated satisfactory results.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"2023 ","pages":"3116223"},"PeriodicalIF":2.6,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10421711/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9988926","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Microwave-Assisted Digestion of Polyurethane Foam as an Alternative to Elution: Solid Phase Extraction of Cd(II) and Pb(II) for Their Determination in Swimming Pool Waters. 微波辅助消解聚氨酯泡沫代替洗脱法:固相萃取法测定游泳池水中Cd(II)和Pb(II)
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2023-01-01 DOI: 10.1155/2023/9624637
Juliana Menezes de Sousa, Graziela Fregonez Baptista Cruz, Luiza Gomes Dos Santos, Ricardo J Cassella
{"title":"Microwave-Assisted Digestion of Polyurethane Foam as an Alternative to Elution: Solid Phase Extraction of Cd(II) and Pb(II) for Their Determination in Swimming Pool Waters.","authors":"Juliana Menezes de Sousa,&nbsp;Graziela Fregonez Baptista Cruz,&nbsp;Luiza Gomes Dos Santos,&nbsp;Ricardo J Cassella","doi":"10.1155/2023/9624637","DOIUrl":"https://doi.org/10.1155/2023/9624637","url":null,"abstract":"<p><p>In this work, a separation/preconcentration method is proposed for the determination of Cd(II) and Pb(II) in swimming pool waters, using ammonium pyrrolidine dithiocarbamate (APDC) as a complexing agent and unloaded polyurethane foam (PUF) as a sorbent. The proposed method was optimized, and the defined optimal conditions were a pH of 7, 30 min of shaking time, 400 mg of PUF, and 0.5% (m/v) of the APDC solution. The release of Cd(II) and Pb(II) from the solid phase was achieved through the total digestion of PUF using a microwave-assisted acid approach with a 10.5 mol·L<sup>-1</sup> HNO<sub>3</sub> solution. The methodology was applied to four samples of swimming pool water for the determination of Cd(II) and Pb(II) using graphite furnace atomic absorption spectrometry (GF AAS). The limits of detection and quantification obtained were 0.02 and 0.06 <i>μ</i>g·L<sup>-1</sup> for Cd(II) and 0.5 e 1.8 <i>μ</i>g·L<sup>-1</sup> for Pb(II), respectively. We analyzed four samples of swimming pool waters, finding Cd concentrations between 0.22 and 1.37 <i>μ</i>g·L<sup>-1</sup>. On the other hand, only one sample presented Pb concentration above the limit of quantification (11.4 <i>μ</i>g·L<sup>-1</sup>). Recovery tests were performed by spiking the samples with known concentrations of the analytes, and recovery percentages between 82% and 105% were obtained.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"2023 ","pages":"9624637"},"PeriodicalIF":2.6,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10243940/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9599281","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Determination of Ten Flavonoids in the Raw and Fermented Fructus Aurantii by Quantitative Analysis of Multicomponents via a Single Marker (QAMS) Based on UPLC. 基于UPLC的单标记多组分定量分析(QAMS)测定金山楂生、发酵中10种黄酮类化合物的含量。
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2023-01-01 DOI: 10.1155/2023/6067647
Ting Yang, Yingying Huang, Qinru Li, Qijian Xu, Yangbing Fang, Jiangling Long, Aihua Huang, Meiqi Wang, Quan Xia
{"title":"Determination of Ten Flavonoids in the Raw and Fermented Fructus Aurantii by Quantitative Analysis of Multicomponents via a Single Marker (QAMS) Based on UPLC.","authors":"Ting Yang,&nbsp;Yingying Huang,&nbsp;Qinru Li,&nbsp;Qijian Xu,&nbsp;Yangbing Fang,&nbsp;Jiangling Long,&nbsp;Aihua Huang,&nbsp;Meiqi Wang,&nbsp;Quan Xia","doi":"10.1155/2023/6067647","DOIUrl":"https://doi.org/10.1155/2023/6067647","url":null,"abstract":"<p><p>Fermented Fructus Aurantii (FFA) is widely used in South China for the treatment of functional dyspepsia. Naringin, neohesperidin, and other flavonoids are the main pharmacodynamic components of FFA. A new method is presented for the simultaneous determination of 10 flavonoids (including flavonoid glycosides and aglycones) in FFA using the quantitative analysis of multicomponents via a single marker (QAMS) approach and is used to investigate changes in flavonoids during fermentation. The viability and precision of QAMS were validated against the ultrahigh-performance liquid chromatography (UPLC), with various UPLC instruments and chromatographic conditions being evaluated. Differences between raw Fructus Aurantii (RFA) and FFA were examined using orthogonal partial least squares discrimination analysis (OPLS-DA) and content determination. The influence of various fermentation conditions on flavonoids was also investigated. There were no appreciable differences between the QAMS and the external standard method (ESM), demonstrating that QAMS is an improved method for the determination of FA and FFA. FFA and RFA can be readily distinguished based on OPLS-DA chemometric modelling and the corresponding chromatograms. In addition, the flavonoid changes after fermentation. Fermentation considerably reduced the contents of flavonoid glycosides, while increasing hesperidin-7-O-glucoside and flavonoid aglycones. Moreover, fermentation conditions impact multiple flavonoids in FA, so controlling these conditions is necessary for the quality control of fermented FA products. This QAMS approach is useful for detecting numerous components in RFA and FFA simply, quickly, and efficiently, thus strengthening the quality control of FA and its fermented products.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"2023 ","pages":"6067647"},"PeriodicalIF":2.6,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10257543/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9618146","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Enantioselective Behavior of Flumequine Enantiomers and Metabolites' Identification in Sediment. 沉积物中氟苯喹对映体的对映选择行为和代谢物的鉴定
IF 2.3 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-12-02 eCollection Date: 2022-01-01 DOI: 10.1155/2022/2184024
Moyong Xue, Xu Gu, Yuchang Qin, Junguo Li, Qingshi Meng, Ming Jia
{"title":"Enantioselective Behavior of Flumequine Enantiomers and Metabolites' Identification in Sediment.","authors":"Moyong Xue, Xu Gu, Yuchang Qin, Junguo Li, Qingshi Meng, Ming Jia","doi":"10.1155/2022/2184024","DOIUrl":"10.1155/2022/2184024","url":null,"abstract":"<p><p>The enantioselective adsorption, degradation, and transformation of flumequine (FLU) enantiomers in sediment were investigated to elucidate the enantioselective environmental behaviors. The results of adsorption test showed that stereoselective differences of FLU enantiomers in sediment samples and the adsorbing capacity of <i>S</i>-(-)-FLU and <i>R</i>-(+)-FLU are higher than the racemate, and the pH values of the sediment determined the adsorption capacity. Enantioselective degradation behaviors were found under nonsterilized conditions and followed pseudo-first-order kinetic. The <i>R</i>-(+)-FLU was preferentially degraded, and there was significant enantioselectivity of the degradation of FLU. It can be concluded that the microorganism was the main reason for the stereoselective degradation in sediments. The physicochemical property of sediments, such as pH value and organic matter content, can affect the degradation rate of FLU. In addition, the process of transformation of FLU enantiomers in water-sediment system had enantioselective behavior, and <i>R-</i>(+)-FLU was preferential transformed. Meanwhile, the main metabolites of FLU in the sediment were decarboxylate and dihydroxylation products. This study contributes the evidence of comprehensively assessing the fate and risk of chiral FLU antibiotic and enantioselective behavior in the environment.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"2022 ","pages":"2184024"},"PeriodicalIF":2.3,"publicationDate":"2022-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9733987/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10682394","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Human Oral Fluid Assay for D- and L- Isomer Detection of Amphetamine and Methamphetamine Using Liquid-Liquid Extraction. 利用液液萃取法检测安非他明和甲基苯丙胺 D-和 L-异构体的人体口腔液分析法
IF 2.3 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-12-02 eCollection Date: 2022-01-01 DOI: 10.1155/2022/4819599
Brian Robbins, Rob E Carpenter, Mary Long, Jacob Perry
{"title":"A Human Oral Fluid Assay for <i>D</i>- and <i>L-</i> Isomer Detection of Amphetamine and Methamphetamine Using Liquid-Liquid Extraction.","authors":"Brian Robbins, Rob E Carpenter, Mary Long, Jacob Perry","doi":"10.1155/2022/4819599","DOIUrl":"10.1155/2022/4819599","url":null,"abstract":"<p><p>Medical providers are increasingly confronted with clinical decision-making that involves (meth)amphetamines. And clinical laboratories need a sensitive, efficient assay for routine assessment of <i>D</i>- and <i>L</i>-isomers to determine the probable source of these potentially illicit analytes. This paper presents a validated method of <i>D</i>- and <i>L</i>-isomer detection in human oral fluid from an extract used for determination of a large oral fluid assay (63 analytes) on an older AB SCIEX 4000 instrument. Taken from the positive extract, <i>D</i>- and <i>L</i>-analytes were added. The method for extraction included addition of internal standard and a 2-step liquid-liquid extraction and dry-down step to concentrate and clean the samples. The samples were suspended in 50% MeOH in water, diluted with mobile phase, with separation and detection accomplished using LC-MS/MS to determine analyte concentration. Once samples were confirmed positive for (meth)amphetamine from the large oral fluid assay, they were further examined for the enantiomeric forms with 50 <i>μ</i>l aliquots of the standards and samples of interest combined with 450 <i>μ</i>l of <i>D-</i> and <i>L-</i>assay mobile phase, then analyzed using chiral column separation, and LC-MS/MS detection with standard curve spanning the range from 2.5 to 1000 ng/mL. The result is a sensitive and accurate detection of <i>D-</i> and <i>L-</i>isomers of amphetamine and methamphetamine in human oral fluid performed on an older model mass spectrometer (AB SCIEX 4000). The novelty of this assay is twofold (a) the 2-step liquid-liquid extraction and dry-down step to concentrate and clean the samples, and (b) its adoption characteristics as a reflex test from a large ODT panel without the need to invest in newer or expensive LC-MS/MS instruments. Finally, this assay also has potential to add a valuable option to high-throughput laboratories seeking a <i>D-</i> and <i>L-</i>testing alternative to urine drug testing methods.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"2022 ","pages":"4819599"},"PeriodicalIF":2.3,"publicationDate":"2022-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9734005/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10333163","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Value of GeneXpert MTB/RIF for Detection in Tuberculosis: A Bibliometrics-Based Analysis and Review GeneXpert MTB/RIF在结核病检测中的价值:基于文献计量学的分析与综述
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-10-15 DOI: 10.1155/2022/2915018
Zhiyi Li
{"title":"The Value of GeneXpert MTB/RIF for Detection in Tuberculosis: A Bibliometrics-Based Analysis and Review","authors":"Zhiyi Li","doi":"10.1155/2022/2915018","DOIUrl":"https://doi.org/10.1155/2022/2915018","url":null,"abstract":"With the continuous development of medical science and technology, especially with the advent of the era of precision diagnosis and treatment, molecular biology detection technology is widely valued and applied as an aid to early diagnosis of tuberculosis. The GeneXpert Mycobacterium tuberculosis Branching (MTB) technology is a suite of semi-nested real-time fluorescent quantitative PCR in vitro diagnostic technologies developed by Cepheid Inc. It targets the rifampicin resistance gene, rpoB, and can detect both MTB and resistance to rifampicin within 2 h. This review analyzed the papers related to GeneXpert using bibliometric software CiteSpace and Bibliometrix. A total of 151 articles were analyzed, spanning from 2011 to 2021. This bibliometrics-based review summarizes the history of the development of GeneXpert in tuberculosis diagnosis and its current status. Contributions of different countries to the topic, journal analysis, key paper analysis, and clustering of keywords were used to analyze this topic.","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"105 1","pages":""},"PeriodicalIF":2.6,"publicationDate":"2022-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79547252","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Comparative Snake Venom Analysis for Facilitating Wildlife Forensics: A Pilot Study 比较蛇毒分析促进野生动物法医:一项试点研究
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-06-03 DOI: 10.1155/2022/8644993
S. Bhargava, K. Kumari, R. Sarin, Rajvinder Singh
{"title":"Comparative Snake Venom Analysis for Facilitating Wildlife Forensics: A Pilot Study","authors":"S. Bhargava, K. Kumari, R. Sarin, Rajvinder Singh","doi":"10.1155/2022/8644993","DOIUrl":"https://doi.org/10.1155/2022/8644993","url":null,"abstract":"Confirm and authentic identification of species is required for the implementation of wildlife laws in cases of illegal trafficking of snake venoms. Illegally trafficked snake venom might be misidentified with other drugs of abuse, and sometimes, the species of venom-yielding snake cannot be verified. Snake venoms from medically important snake species, Naja naja and Daboia russelii, were procured from Irula Snake Catcher's Society, Tamil Nadu, India. Comparative analyses of both venoms were carried out using SDS-PAGE, LC-MS/MS, ICP-MS, and mtDNA analysis. The protein concentration of Naja naja and Daboia russelii venoms was 76.1% and 83.9%, respectively. SDS analysis showed a distinct banding pattern of both venoms. LC-MS/MS results showed proteins and toxins from 12 to 14 protein families in Naja naja and Daboia russelii venoms. Elemental analysis using ICP-MS showed a different profile of some elements in both venoms. mtDNA analysis of venoms using universal primers against Cyt b gene showed homology with sequence of Naja naja and Daboia russelii genes. The study proposed a template of various conventional and advanced molecular and instrumental techniques with their pros and cons. The template can be used by forensic science laboratories for detection, screening, and confirmatory analysis of suspected venoms of snakes. Clubbing of various techniques can be used to confirm the identification of species of snake from which the alleged venom was milked. The results can be helpful in framing charge-sheets against accused of illegal venom trafficking and can also be used to verify the purity and quality of commercially available snake venoms.","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"10 1","pages":""},"PeriodicalIF":2.6,"publicationDate":"2022-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82267357","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Point-of-Care Based Electrochemical Immunoassay for Epstein-Barr Virus Detection 基于护理点的电化学免疫分析法检测eb病毒
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-05-30 DOI: 10.1155/2022/5711384
Miao-Miao Yu, Ming Liu, Yuan Li
{"title":"Point-of-Care Based Electrochemical Immunoassay for Epstein-Barr Virus Detection","authors":"Miao-Miao Yu, Ming Liu, Yuan Li","doi":"10.1155/2022/5711384","DOIUrl":"https://doi.org/10.1155/2022/5711384","url":null,"abstract":"This work describes a label-free electrochemical immunosensor for the sensing of Epstein-Barr virus (EBV) with high sensitivity. First, a monolayer of 1,6-hexanedithiol (HDT) was fabricated on the screen-printed electrode surface by the interaction between sulfur atoms and SPE. AuNPs can be modified on the electrode by the Au-S bond formed between the HDT-free group and Au atom in AuNPs. Protein A is then adsorbed onto AuNPs. Several parameters were optimized. The optimum concentration of protein A is 0.6 mg/mL. The optimum immobilization time for protein A is 90 min. The optimum concentration of antibody is 80 μg/mL. The optimum immobilization time for antibody is 90 min. Directional immobilization of EBV antibody is achieved by high affinity binding of protein A to the Fc segment of antibody. When antigen specifically binds to antibody, the formation of immune complexes blocks electron transfer of [Fe(CN)6]4-/3- and is reflected in the detection of cyclic voltammetry/electrochemical impedance spectroscopy. The detection range is 1 pg/mL–l00 ng/mL with a LOD of 0.1 pg/mL. In addition, the proposed sensor exhibited an excellent antiinterference property.","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"178 1","pages":""},"PeriodicalIF":2.6,"publicationDate":"2022-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85441090","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Recent Advances and Perspectives on the Sources and Detection of Antibiotics in Aquatic Environments 水生环境中抗生素来源及检测研究进展与展望
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-05-25 DOI: 10.1155/2022/5091181
Yanbo Zeng, Fengqin Chang, Qi Liu, Lizeng Duan, Donglin Li, Hucai Zhang
{"title":"Recent Advances and Perspectives on the Sources and Detection of Antibiotics in Aquatic Environments","authors":"Yanbo Zeng, Fengqin Chang, Qi Liu, Lizeng Duan, Donglin Li, Hucai Zhang","doi":"10.1155/2022/5091181","DOIUrl":"https://doi.org/10.1155/2022/5091181","url":null,"abstract":"Water quality and safety are vital to the ecological environment, social development, and ecological susceptibility. The extensive use and continuous discharge of antibiotics have caused serious water pollution; antibiotics are widely found in freshwater, drinking water, and reservoirs; and this pollution has become a common phenomenon and challenge in global water ecosystems, as water polluted by antibiotics poses serious risks to human health and the ecological environment. Therefore, the antibiotic content in water should be identified, monitored, and eliminated. Nevertheless, there is no single method that can detect all different types of antibiotics, so various techniques are often combined to produce reliable results. This review summarizes the sources of antibiotic pollution in water, covering three main aspects: (1) wastewater discharges from domestic sewage, (2) medical wastewater, and (3) animal physiology and aquaculture. The existing analytical techniques, including extraction techniques, conventional detection methods, and biosensors, are reviewed. The electrochemical biosensors have become a research hotspot in recent years because of their rapid detection, high efficiency, and portability, and the use of nanoparticles contributes to these outstanding qualities. Additionally, the comprehensive quality evaluation of various detection methods, including the linear detection range, detection limit (LOD), and recovery rate, is discussed, and the future of this research field is also prospected.","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"18 1","pages":""},"PeriodicalIF":2.6,"publicationDate":"2022-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73628096","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信