Journal of Analytical Methods in Chemistry最新文献

筛选
英文 中文
The Value of GeneXpert MTB/RIF for Detection in Tuberculosis: A Bibliometrics-Based Analysis and Review GeneXpert MTB/RIF在结核病检测中的价值:基于文献计量学的分析与综述
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-10-15 DOI: 10.1155/2022/2915018
Zhiyi Li
{"title":"The Value of GeneXpert MTB/RIF for Detection in Tuberculosis: A Bibliometrics-Based Analysis and Review","authors":"Zhiyi Li","doi":"10.1155/2022/2915018","DOIUrl":"https://doi.org/10.1155/2022/2915018","url":null,"abstract":"With the continuous development of medical science and technology, especially with the advent of the era of precision diagnosis and treatment, molecular biology detection technology is widely valued and applied as an aid to early diagnosis of tuberculosis. The GeneXpert Mycobacterium tuberculosis Branching (MTB) technology is a suite of semi-nested real-time fluorescent quantitative PCR in vitro diagnostic technologies developed by Cepheid Inc. It targets the rifampicin resistance gene, rpoB, and can detect both MTB and resistance to rifampicin within 2 h. This review analyzed the papers related to GeneXpert using bibliometric software CiteSpace and Bibliometrix. A total of 151 articles were analyzed, spanning from 2011 to 2021. This bibliometrics-based review summarizes the history of the development of GeneXpert in tuberculosis diagnosis and its current status. Contributions of different countries to the topic, journal analysis, key paper analysis, and clustering of keywords were used to analyze this topic.","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.6,"publicationDate":"2022-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79547252","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection. edta型改性交联聚苯乙烯螯合树脂预富集海水痕量金属。
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-10-14 eCollection Date: 2022-01-01 DOI: 10.1155/2022/2080600
Chao Li, Linna Duan, Mingchao Han, Hongwei He, Mengxiang Yuan, Hairong Wang
{"title":"A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection.","authors":"Chao Li,&nbsp;Linna Duan,&nbsp;Mingchao Han,&nbsp;Hongwei He,&nbsp;Mengxiang Yuan,&nbsp;Hairong Wang","doi":"10.1155/2022/2080600","DOIUrl":"https://doi.org/10.1155/2022/2080600","url":null,"abstract":"<p><p>The determination of trace metals in seawater is an important project of marine environmental monitoring. However, the presence of many alkali metal ions with high concentration, such as sodium ion, seriously interferes with the detection limit and accuracy of atomic absorption spectrometry (AAS, flame/graphite furnace integrated). The conventional chemical methods for the enrichment of trace metals are complex, and low boiling point organic solvents are used. In this paper, a kind of commercial cross-linked polystyrene resin microspheres was chloromethylated and aminated to introduce EDTA-type amino polycarboxylic groups and then loaded in a column as the absorption filler. A set of seawater pretreatment and enrichment devices was designed and assembled. The enriching process and conditions of trace Cu, Zn, Pb, and Cd in standard seawater were studied. 10 g of the modified resin could enrich the equivalent seawater and remove successfully the light metal ions. pH = 5∼9 and 0.2 mL/min of the flow rate were the suitable conditions for preconcentration. The enriched metal ions in the eluent were analyzed on the AAS. Compared with the conventional solvent method, the novel material and enrichment device have high preconcentration efficiency, strong anti-interference ability, and low cost and could be directly applied for routine seawater detection.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.6,"publicationDate":"2022-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9586797/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40581412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis of Cationic Vitamins in Cell Culture Medium Samples by Capillary Zone Electrophoresis. 利用毛细管区带电泳分析细胞培养基样品中的阳离子维生素。
IF 2.3 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-10-06 eCollection Date: 2022-01-01 DOI: 10.1155/2022/2819855
Debbie van der Burg, Hermann Wätzig, Cari E Sänger-van de Griend
{"title":"Analysis of Cationic Vitamins in Cell Culture Medium Samples by Capillary Zone Electrophoresis.","authors":"Debbie van der Burg, Hermann Wätzig, Cari E Sänger-van de Griend","doi":"10.1155/2022/2819855","DOIUrl":"10.1155/2022/2819855","url":null,"abstract":"<p><p>This paper describes a capillary electrophoresis method for the determination of the cationic B-vitamins thiamine, nicotinamide, pyridoxine, pyridoxal, and pyridoxamine in untreated cell culture medium samples. The effects of the buffering capacity, the mobility of the coion, and the preconditioning solution on the robustness of the method were investigated. Using a 100 mM phosphoric acid and 55 mM triethanolamine background electrolyte at pH 2.3 and capillary preconditioning with 1 M NaOH, all five vitamins could be separated with good resolution. Preliminary method validation data over the range 10-110 <i>µ</i>M for undiluted samples, with 10 <i>μ</i>M being the lower range limit of quantification QL, showed accuracy recoveries of 94-104%, and migration time and peak area repeatabilities within 0.4% RSD and 2.6% RSD, respectively.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2022-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9560846/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33515629","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Pharmacokinetic Analysis of Diosgenin in Rat Plasma by a UPLC-MS/MS Approach. 大鼠血浆中薯蓣皂苷元药动学的UPLC-MS/MS分析。
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-09-30 eCollection Date: 2022-01-01 DOI: 10.1155/2022/5607347
Pei Liu, Lin Xu, Jing-Han Guo, Jin-Hua Chang, Xi-Gang Liu, He-Fei Xue, Ru-Xing Wang, Zhong-Si Li, Guang-Xin Miao, Cui-Zhe Liu, Jian-Yu Zhou
{"title":"Pharmacokinetic Analysis of Diosgenin in Rat Plasma by a UPLC-MS/MS Approach.","authors":"Pei Liu,&nbsp;Lin Xu,&nbsp;Jing-Han Guo,&nbsp;Jin-Hua Chang,&nbsp;Xi-Gang Liu,&nbsp;He-Fei Xue,&nbsp;Ru-Xing Wang,&nbsp;Zhong-Si Li,&nbsp;Guang-Xin Miao,&nbsp;Cui-Zhe Liu,&nbsp;Jian-Yu Zhou","doi":"10.1155/2022/5607347","DOIUrl":"https://doi.org/10.1155/2022/5607347","url":null,"abstract":"<p><p>Diosgenin, a steroidal sapogenin, has attracted attention worldwide owing to its pharmacological properties, including antitumor, cardiovascular protective, hypolipidemic, and anti-inflammatory effects. The current diosgenin analysis methods have the disadvantages of long analysis time and low sensitivity. The aim of the present study was to establish an efficient, sensitive ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) approach for pharmacokinetic analysis of diosgenin amorphous solid dispersion (ASD) using tanshinone IIA as an internal standard (IS). Male Sprague-Dawley rats were orally administered diosgenin ASD, and orbital blood samples were collected for analysis. Protein precipitation was performed with methanol-acetonitrile (50 : 50, v/v), and the analytes were separated under isocratic elution by applying acetonitrile and 0.03% formic acid aqueous solution at a ratio of 80 : 20 as the mobile phase. MS with positive electron spray ionization in multiple reaction monitoring modes was applied to determine diosgenin and IS with <i>m/z</i> 415.2⟶271.2 and <i>m/z</i> 295.2⟶277.1, respectively. This approach showed a low limit of quantification of 0.5 ng/ml for diosgenin and could detect this molecule at a concentration range of 0.5 to 1,500 ng/ml (<i>r</i> = 0.99725). The approach was found to have intra- and inter-day precision values ranging from 1.42% to 6.91% and from 1.25% to 3.68%, respectively. Additionally, the method showed an accuracy of -6.54 to 4.71%. The recoveries of diosgenin and tanshinone IIA were 85.81-100.27% and 98.29%, respectively, with negligible matrix effects. Diosgenin and IS were stable under multiple storage conditions. Pharmacokinetic analysis showed that the <i>C</i> <sub>max</sub> and AUC<sub>0⟶t</sub> of diosgenin ASD were significantly higher than those of the bulk drug. A sensitive, simple, UPLC-MS/MS analysis approach was established and used for the pharmacokinetic analysis of diosgenin ASD in rats after oral administration.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.6,"publicationDate":"2022-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553667/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33515625","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Determination and Difference Analysis of Phenolic Compounds in Smokers' Saliva and Mainstream Smoke. 吸烟者唾液和主流烟雾中酚类化合物的测定与差异分析
IF 2.3 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-09-29 eCollection Date: 2022-01-01 DOI: 10.1155/2022/6788394
Xiaoxi Si, Jianyun Yang, Fengmei Zhang, Ruizhi Zhu, Chunbo Liu, Wei Jiang, Qingpeng Shen, Pei He, Shiyun Tang, Zhenjie Li, Zhihua Liu, Junheng You, Zhang Di
{"title":"Determination and Difference Analysis of Phenolic Compounds in Smokers' Saliva and Mainstream Smoke.","authors":"Xiaoxi Si, Jianyun Yang, Fengmei Zhang, Ruizhi Zhu, Chunbo Liu, Wei Jiang, Qingpeng Shen, Pei He, Shiyun Tang, Zhenjie Li, Zhihua Liu, Junheng You, Zhang Di","doi":"10.1155/2022/6788394","DOIUrl":"10.1155/2022/6788394","url":null,"abstract":"<p><p>To study the differences in phenolic compounds between tobacco smokers' saliva and mainstream smoke, a method was developed for the analysis of 12 phenolic compounds in saliva and mainstream smoke based on ultrahigh-performance liquid chromatography with fluorescence detection (UPLC-FLD). The contents and distributions of phenolic compounds in tobacco smokers' saliva and mainstream smoke were compared. The results were as follows: (1) Phenolic compounds were quantitatively analyzed by the internal standard method using 4-fluorophenol as an internal standard. For smokers' saliva samples, the limits of quantification (LOQs) ranged from 2.2 to 19.1 <i>μ</i>g/L, and the recoveries were from 80.2% to 119.2% at the three spiked levels. For mainstream smoke samples, the LOQs ranged from 0.03 to 0.26 <i>μ</i>g/cig, and the recoveries ranged from 84.9% to 107.0% at the three spiked levels. (2) The contents of phenolic compounds from 14 cigarettes in mainstream smoke and smokers' saliva were determined. In mainstream smoking, the main phenolic compounds were hydroquinone, catechol, phenol, <i>meta</i>- and <i>para</i>-Cresol, and <i>o</i>-methylhydroquinone. In smokers' saliva, the main phenolic compounds were phenol and <i>meta</i>- and <i>para</i>-Cresol and the contents of phenolic compounds in smokers' saliva from different cigarettes were significantly different. (3) The content distribution patterns of phenolic compounds in smokers' saliva differed from those in mainstream smoke. The predominant phenolic compound in mainstream smoke was dihydroxybenzene, while monophenols predominated in smokers' saliva. (4) The contents of phenolic compounds from five kinds of cigarettes were analyzed in the saliva of different smokers using principal component analysis, which indicated that cigarettes with different sensory effects were clearly distinguished by differences in the contents of phenolic compounds in saliva.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.3,"publicationDate":"2022-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9536968/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33496565","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis of Specific Perfluorohexane Sulfonate Isomers by Liquid Chromatography-Tandem Mass Spectrometry: Method Development and Application in Source Apportionment. 液相色谱-串联质谱法分析特定的全氟己烷磺酸异构体:方法的发展及其在源解析中的应用。
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-09-22 eCollection Date: 2022-01-01 DOI: 10.1155/2022/8704754
Liping Yang, Xin Chen, Lingyan Zhu, Yixin Wang, Guoqiang Shan
{"title":"Analysis of Specific Perfluorohexane Sulfonate Isomers by Liquid Chromatography-Tandem Mass Spectrometry: Method Development and Application in Source Apportionment.","authors":"Liping Yang,&nbsp;Xin Chen,&nbsp;Lingyan Zhu,&nbsp;Yixin Wang,&nbsp;Guoqiang Shan","doi":"10.1155/2022/8704754","DOIUrl":"https://doi.org/10.1155/2022/8704754","url":null,"abstract":"<p><p>Characterization of perfluorohexane sulfonate (PFHxS) isomers, a chemical proposed for listing under the Stockholm Convention, is important to elucidate its environmental behaviors and sources. Optimized chromatographic separation coupled with monitoring of the characteristic fragments enabled the identification of four mono-substituted and two di-substituted branched PFHxS isomers. The transitions of molecular ions <i>m/z</i> 399 to the fragments <i>m/z</i> 80 (<i>n</i>-), <i>m/z</i> 169 (<i>iso-</i>), <i>m/z</i> 319 (<i>1m-</i>), <i>m/z</i> 80 (<i>2m</i>-), and <i>m/z</i> 180 (<i>3m</i>-) were selected for quantifying the mono-substituted isomers. Method accuracy of the established LC-MS/MS was verified by comparing the results of technical products with those determined by <sup>19</sup>F-nuclear magnetic resonance (NMR). The developed method was then used to quantify the isomeric compositions of PFHxS in the perfluorooctane sulfonate (PFOS) industrial products which contained PFHxS as an impurity, as well as in several kinds of water samples, with the limits of detection for all isomers in the range of 4 to 30 pg/L. For the first time, a liquid chromatography-tandem mass spectrometry method was established to separate and quantify the PFHxS isomers. The isomeric profiling of water samples suggested that PFHxS in the waters was mainly due to the direct contamination of PFHxS rather than from PFOS contamination.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.6,"publicationDate":"2022-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553683/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33515627","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Novel Carbon Paste Electrode Modified with N1-Hydroxy-N1,N2-Diphenylbenzamidine for the Electrochemical Determination of Cadmium(II) in Environmental Samples. 用n1 -羟基- n1, n2 -二苯基苯并脒修饰碳糊电极电化学测定环境样品中镉(II)
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-09-22 eCollection Date: 2022-01-01 DOI: 10.1155/2022/3426575
Endale Tesfaye, Bhagwan Singh Chandravanshi, Negussie Negash, Merid Tessema
{"title":"A Novel Carbon Paste Electrode Modified with N<sup>1</sup>-Hydroxy-N<sup>1</sup>,N<sup>2</sup>-Diphenylbenzamidine for the Electrochemical Determination of Cadmium(II) in Environmental Samples.","authors":"Endale Tesfaye,&nbsp;Bhagwan Singh Chandravanshi,&nbsp;Negussie Negash,&nbsp;Merid Tessema","doi":"10.1155/2022/3426575","DOIUrl":"https://doi.org/10.1155/2022/3426575","url":null,"abstract":"<p><p>The present study introduces a novel electrode for rapid, highly sensitive, and selective electrochemical sensor for cadmium(II) using 5% N<sup>1</sup>-hydroxy-N<sup>1</sup>,N<sup>2</sup>-diphenylbenzamidine (HDPBA) modified carbon paste electrode (CPE) (HDPBA‒CPE). Surface characterizations and structural analysis of the proposed HDPBA‒CPE were performed using several analytical techniques. The voltammetric measurements of Cd(II) were conducted by cyclic voltammetry (CV) and square wave anodic stripping voltammetry (SWASV). Several experimental conditions such as composition and pH of buffer solutions, HDPBA composition, accumulation potential and time, and other voltammetric conditions were optimized. Cd(II) was preconcentrated on the modified electrode surface for 270 s using Britton Robinson (B-R) buffer (0.1 M, pH 4) at -1.0 V versus Ag/AgCl, followed by electrochemical oxidation of the accumulated Cd(II) in the positive scan of SWASV after a quiet time of 10 s. Under optimized parameters, the proposed method showed a linear range of 0.3-100 nM Cd(II) with a detection limit of 0.032 nM. The fabricated HDPBA-modified carbon paste electrode exhibited excellent sensitivity, selectivity, stability, and reproducibility (with RSD of 3.8%). The developed HDPBA‒CPE was used for the quantification of Cd(II) in tobacco and environmental water samples, and it was found to be applicable for the determination of different types of real samples.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.6,"publicationDate":"2022-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553701/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33515624","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Development of Microscopy Apparatus Switchable between Fluorescence and Ultralow-Frequency Raman Modes. 荧光和超低频拉曼模式切换显微镜装置的研制。
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-09-19 eCollection Date: 2022-01-01 DOI: 10.1155/2022/2694545
Ken Takazawa
{"title":"Development of Microscopy Apparatus Switchable between Fluorescence and Ultralow-Frequency Raman Modes.","authors":"Ken Takazawa","doi":"10.1155/2022/2694545","DOIUrl":"https://doi.org/10.1155/2022/2694545","url":null,"abstract":"<p><p>In this study, a microscopy apparatus that can switch between the fluorescence microscopy and ultralow-frequency Raman microscopy modes was developed. The apparatus can be easily constructed by equipping a standard epi-illumination microscope with an additional port featuring a removable half mirror. Owing to the switchability, fluorescence imaging, and spectroscopy, Raman spectroscopy in the frequency range down to ∼10 cm<sup>-1</sup> can be performed using the apparatus. To demonstrate the advantageous features of this apparatus, micron-sized crystals of perylene, which have two polymorphic forms, were analyzed. The two polymorphs were clearly identified based on their shapes, fluorescence spectra, and ultralow-frequency Raman spectra, all of which can be observed with our apparatus alone. These results indicate that the apparatus is a powerful tool for the analysis and characterization of various nano-/micron-sized crystals.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.6,"publicationDate":"2022-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553702/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33515631","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Determination of Tropifexor in Beagle Dog Plasma by UPLC-MS/MS and Its Application in Pharmacokinetics. 超高效液相色谱-质谱联用法测定比格犬血浆中托非福的含量及其药动学研究。
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-09-17 eCollection Date: 2022-01-01 DOI: 10.1155/2022/2823214
Yan-Ding Su, Xin-Yi Wei, Xiao-Hang Su, Ghulam Woshur, Xiao-Nan Geng, Xiang-Jun Qiu
{"title":"Determination of Tropifexor in Beagle Dog Plasma by UPLC-MS/MS and Its Application in Pharmacokinetics.","authors":"Yan-Ding Su,&nbsp;Xin-Yi Wei,&nbsp;Xiao-Hang Su,&nbsp;Ghulam Woshur,&nbsp;Xiao-Nan Geng,&nbsp;Xiang-Jun Qiu","doi":"10.1155/2022/2823214","DOIUrl":"https://doi.org/10.1155/2022/2823214","url":null,"abstract":"<p><p>The primary objective of this study was to develop and validate an efficient and accurate ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) approach as a means to detect tropifexor plasma concentrations in beagle dogs and to study its pharmacokinetic profile in beagle dogs. The chromatographic separation of tropifexor and oprozomib (internal standard, ISTD) on the column, with the addition of acetonitrile for rapid precipitation and protein extraction, was achieved with 0.1% formic acid aqueous solution-acetonitrile for the mobile phase. A Xevo TQ-S triple quadrupole tandem mass spectrometer, under the selective reaction monitoring (SRM) mode, for the determination of the concentrations in the positive ion mode. The mass transfer pairs of tropifexor and oprozomib (ISTD) were m/z 604.08 ⟶ 228.03 and m/z 533.18 ⟶ 199.01, respectively. The profile displayed well linearity with calibration curves for tropifexor and oprozomib (ISTD) ranging from 1.0 to 200 ng/mL. In parallel, the lower limit of quantification (LLOQ) value for tropifexor could be measured with the aid of this novel technique at 1.0 ng/mL. In addition, the scope of intraday and interday for analyte accuracy was between -4.86% and 1.16%, with a precision of <7.31%. The recoveries of the analytes were >88.13% and were free of significant matrix effects. The stability met the requirements for the quantification of plasma samples under various conditions. Finally, the pharmacokinetic profile of tropifexor in beagle dog plasma following oral administration of 0.33 mg/kg tropifexor was determined by using the method facilitated in this work.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.6,"publicationDate":"2022-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509244/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40375560","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Simultaneous Determination of 32 Pyrrolizidine Alkaloids in Two Traditional Chinese Medicine Preparations by UPLC-MS/MS. UPLC-MS/MS同时测定两种中药制剂中32种吡咯利西啶类生物碱。
IF 2.6 3区 化学
Journal of Analytical Methods in Chemistry Pub Date : 2022-09-14 eCollection Date: 2022-01-01 DOI: 10.1155/2022/7611501
Shi Cheng, Wei Sun, Xiaoning Zhao, Ping Wang, Wensheng Zhang, Shunnan Zhang, Xiangwei Chang, Zhengliang Ye
{"title":"Simultaneous Determination of 32 Pyrrolizidine Alkaloids in Two Traditional Chinese Medicine Preparations by UPLC-MS/MS.","authors":"Shi Cheng,&nbsp;Wei Sun,&nbsp;Xiaoning Zhao,&nbsp;Ping Wang,&nbsp;Wensheng Zhang,&nbsp;Shunnan Zhang,&nbsp;Xiangwei Chang,&nbsp;Zhengliang Ye","doi":"10.1155/2022/7611501","DOIUrl":"https://doi.org/10.1155/2022/7611501","url":null,"abstract":"<p><p>Pyrrolizidine alkaloids (PAs) constitute a class of phytotoxin which demonstrates strong hepatotoxicity. In China, many plants containing PAs are used as traditional medicines or medicinal preparations, which could harm human health and safety. Xiaoyao Tablet (XYT) is an antidepressant drug registered in the European Union (EU), Compound Danshen Dropping Pills (CDDP) is a commonly used drug for coronary heart disease, and phase III clinical study is ongoing in the United States. The purpose of this study is to provide data to support the use of Chinese medicine preparations internationally and to establish analytical methods for 32 PAs in XYT and CDDP. The extraction parameters that were optimized include solid-phase extraction (SPE) cartridge, extraction method, and extraction solvent. Then ultra-performance liquid chromatography coupled with triple-quadrupole linear ion-traptandem mass spectrometry (UPLC-MS/MS) was developed to effectively and efficiently quantify the 32 PAs of the XYT and CDDP. The analytical methods for XYT and CDDP were verified respectively. For XYT, the analytical method for 32 PAs was linear, and the correlation coefficient <i>r</i> was greater than 0.994; the recovery (REC%) at 10-2000 <i>μ</i>g/kg was 73.3%-118.5%, and the relative standard deviation (RSD%) was 2.1%-15.4%. The CDDP REC% was 71.8%-112.0%, and the RSD% was 2.0%-17.1%. This study provides technical and data support for the registration of Chinese patented medicines in the EU, controls quality and ensures safety, and is committed to the internationalization and standardization of Chinese patented medicines.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.6,"publicationDate":"2022-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9492412/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33487042","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信