Eye and Vision最新文献

筛选
英文 中文
Insights into atypical segmental layer thicknesses and phase retardation in thick corneas using ultrahigh-resolution polarization-sensitive optical coherence tomography. 利用超高分辨率偏振敏感光学相干断层扫描,深入了解厚角膜的非典型节段层厚度和相位延迟。
IF 4.1 1区 医学
Eye and Vision Pub Date : 2024-07-15 DOI: 10.1186/s40662-024-00391-4
Rahul P Patil, Rohit Shetty, Pooja Khamar, Yash G Patel, Raghav R Narasimhan, Anushree A Bhatkal, Christopher K Hitzenberger, Michael Pircher, Rudy M M R Nuijts, Abhijit Sinha Roy
{"title":"Insights into atypical segmental layer thicknesses and phase retardation in thick corneas using ultrahigh-resolution polarization-sensitive optical coherence tomography.","authors":"Rahul P Patil, Rohit Shetty, Pooja Khamar, Yash G Patel, Raghav R Narasimhan, Anushree A Bhatkal, Christopher K Hitzenberger, Michael Pircher, Rudy M M R Nuijts, Abhijit Sinha Roy","doi":"10.1186/s40662-024-00391-4","DOIUrl":"10.1186/s40662-024-00391-4","url":null,"abstract":"<p><strong>Background: </strong>Accurately assessing corneal structural status is challenging when thickness deviates from the average. Polarization-sensitive optical coherence tomography (PS-OCT) measures tissue-specific polarization changes, providing additional contrast for accurate segmentations and aids in phase retardation (PR) measurements. Previous studies have shown PR's effectiveness in identifying sub-clinical keratoconus (KC) in asymmetric cases. Thus, this study aims to assess PR distribution in thick corneas with and without KC.</p><p><strong>Methods: </strong>In this retrospective and cross-sectional study, 45 thick corneas from 30 Asian-Indian subjects, categorized into healthy (n = 26) and KC (n = 19) groups were analyzed. All eyes underwent standard clinical evaluations, tomographic assessments, and corneal biomechanics measurements. PR and individual layer thicknesses were measured using custom-designed ultrahigh-resolution PS-OCT. PR en-face maps were generated. Individual layer thicknesses and PR analysis was conducted across multiple zones, extending up to 8-10 mm in diameter. All eyes in the study had not undergone interventions, received topical medications, or had previous corneal disease history.</p><p><strong>Results: </strong>Significant differences were found in spherical and cylindrical powers, keratometry, pachymetry, and biomechanical indices (all P < 0.01). Thickness profiles from PS-OCT showed significant differences in the 4-8 mm zones only. Bowman's layer thickness significantly differed only in the central 2 mm zone (P = 0.02). The median PR values showed marginal differences in the central 2 mm zone (P = 0.0565). Additionally, there were significant differences observed in the 2-4 mm and 4-6 mm zones (P = 0.0274 and P = 0.0456, respectively). KC eyes exhibited an atypical PR distribution and corneal thinning, while normal eyes maintained a uniform Bowman's layer thickness and PR maps with larger areas of higher PR.</p><p><strong>Conclusion: </strong>The study revealed distinctive PR distribution in thick corneas among healthy and KC groups. Using an ultrahigh-resolution PS-OCT the significance of Bowman's layer thickness in these groups was also emphasized. The study offered potential improvements in clinical diagnostics by enhancing our understanding of corneal structure and its altered function.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"30"},"PeriodicalIF":4.1,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11247896/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141616135","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Smart decision support system for keratoconus severity staging using corneal curvature and thinnest pachymetry indices. 利用角膜曲率和最薄角膜厚度指数对角膜炎严重程度进行分期的智能决策支持系统。
IF 4.1 1区 医学
Eye and Vision Pub Date : 2024-07-08 DOI: 10.1186/s40662-024-00394-1
Zahra J Muhsin, Rami Qahwaji, Mo'ath AlShawabkeh, Saif Aldeen AlRyalat, Muawyah Al Bdour, Majid Al-Taee
{"title":"Smart decision support system for keratoconus severity staging using corneal curvature and thinnest pachymetry indices.","authors":"Zahra J Muhsin, Rami Qahwaji, Mo'ath AlShawabkeh, Saif Aldeen AlRyalat, Muawyah Al Bdour, Majid Al-Taee","doi":"10.1186/s40662-024-00394-1","DOIUrl":"10.1186/s40662-024-00394-1","url":null,"abstract":"<p><strong>Background: </strong>This study proposes a decision support system created in collaboration with machine learning experts and ophthalmologists for detecting keratoconus (KC) severity. The system employs an ensemble machine model and minimal corneal measurements.</p><p><strong>Methods: </strong>A clinical dataset is initially obtained from Pentacam corneal tomography imaging devices, which undergoes pre-processing and addresses imbalanced sampling through the application of an oversampling technique for minority classes. Subsequently, a combination of statistical methods, visual analysis, and expert input is employed to identify Pentacam indices most correlated with severity class labels. These selected features are then utilized to develop and validate three distinct machine learning models. The model exhibiting the most effective classification performance is integrated into a real-world web-based application and deployed on a web application server. This deployment facilitates evaluation of the proposed system, incorporating new data and considering relevant human factors related to the user experience.</p><p><strong>Results: </strong>The performance of the developed system is experimentally evaluated, and the results revealed an overall accuracy of 98.62%, precision of 98.70%, recall of 98.62%, F1-score of 98.66%, and F2-score of 98.64%. The application's deployment also demonstrated precise and smooth end-to-end functionality.</p><p><strong>Conclusion: </strong>The developed decision support system establishes a robust basis for subsequent assessment by ophthalmologists before potential deployment as a screening tool for keratoconus severity detection in a clinical setting.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"28"},"PeriodicalIF":4.1,"publicationDate":"2024-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11229244/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141558440","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Rotational stability and refractive outcomes of a new hydrophobic acrylic toric intraocular lens. 新型疏水性丙烯酸散光眼内透镜的旋转稳定性和屈光效果。
IF 4.1 1区 医学
Eye and Vision Pub Date : 2024-07-02 DOI: 10.1186/s40662-024-00393-2
Daniel Schartmüller, Marcus Lisy, Nikolaus Mahnert, Markus Schranz, Victor Danzinger, Luca Schwarzenbacher, Stefan Pieh, Claudette Abela-Formanek, Christina Leydolt, Rupert Menapace
{"title":"Rotational stability and refractive outcomes of a new hydrophobic acrylic toric intraocular lens.","authors":"Daniel Schartmüller, Marcus Lisy, Nikolaus Mahnert, Markus Schranz, Victor Danzinger, Luca Schwarzenbacher, Stefan Pieh, Claudette Abela-Formanek, Christina Leydolt, Rupert Menapace","doi":"10.1186/s40662-024-00393-2","DOIUrl":"10.1186/s40662-024-00393-2","url":null,"abstract":"<p><strong>Purpose: </strong>To assess rotational stability and refractive outcomes of a new toric hydrophobic acrylic intraocular lens (IOL).</p><p><strong>Design: </strong>Single-center, prospective, interventional clinical trial.</p><p><strong>Methods: </strong>A total of 130 eyes of 82 patients with age-related cataract and total corneal astigmatism of greater than 1.0 diopters (D) received a hydrophobic acrylic toric IOL Clareon CNW0T3-9. Baseline measurement for rotational stability evaluation was performed at the end of surgery (EOS), with the patient still supine on the operating table, using non-movable vessels as reference landmarks. Postoperative retroillumination pictures were taken at 1 h, 1 week, 1 month and 4-6 months postoperatively. Subjective manifest refraction was assessed at the 6 months follow-up visit.</p><p><strong>Results: </strong>Final results were obtained in 126 eyes of 80 patients. Mean absolute rotation from EOS to 6 months was 1.33 ± 2.00 [0.01, 19.80] degrees. Rotational stability values from EOS to 1 h, 1 h to 1 week, 1 week to 1 month and 1 month to 6 months were 0.86 ± 0.82 [0.00, 3.90], 1.06 ± 1.94 [0.00, 19.45], 0.47 ± 0.42 [0.00, 2.03] and 0.38 ± 0.40 [0.00, 2.56] degrees. Mean preoperative corneal astigmatism was 1.78 ± 0.83 [1.00, 4.76] D which changed to a mean postoperative refractive astigmatism of 0.33 ± 0.27 [0.00, 1.25] D at 6 months.</p><p><strong>Conclusion: </strong>The Clareon toric IOL presented very good rotational stability with a mean absolute rotation below 1.4° from EOS to 6 months. Only two IOLs rotated more than 5° with none of them requiring repositioning surgery. Refractive outcomes were satisfying with a mean residual refractive astigmatism below 0.50 D.</p><p><strong>Trial registration: </strong>Registered at Clinicaltrials.gov NCT03803852 ; on May 17, 2022.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"25"},"PeriodicalIF":4.1,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11218059/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141476271","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Keratectasia severity staging and progression assessment based on the biomechanical E-staging. 基于生物力学 E 分期的角化病严重程度分期和进展评估。
IF 4.1 1区 医学
Eye and Vision Pub Date : 2024-07-01 DOI: 10.1186/s40662-024-00392-3
Elias Flockerzi, Berthold Seitz
{"title":"Keratectasia severity staging and progression assessment based on the biomechanical E-staging.","authors":"Elias Flockerzi, Berthold Seitz","doi":"10.1186/s40662-024-00392-3","DOIUrl":"10.1186/s40662-024-00392-3","url":null,"abstract":"<p><p>Until recently, corneal topography has been the gold standard in detecting keratectasia and monitoring its progression. The recently introduced ABCD tomographic keratoconus staging system focuses on anterior (\"A\") and posterior (\"B\") radius of curvature, thinnest corneal thickness (\"C\"), best-corrected visual acuity with spectacles (\"D\") and is supplemented with the introduction of the biomechanical E-staging (BEST, \"E\"). The need for biomechanical staging arose from the fact of altered biomechanical characteristics of keratectasia in comparison to healthy corneas. Ectatic corneas usually exhibit a biomechanical weakening and greater deformation than healthy corneas when exposed to a biomechanical stressor such as a standardized air puff indentation as provided by the Corvis ST® (CST, Oculus, Wetzlar, Germany). The BEST is based on the linear term of the Corvis Biomechanical Index (CBI) and provides a biomechanical keratoconus severity staging and progression assessment within the CST software. This review traces the development of the BEST as an addition to the tomographic ABCD staging system and highlights its strengths and limitations when applied in daily practice for the detection, monitoring and progression assessment in keratectasia.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"24"},"PeriodicalIF":4.1,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11215830/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141467274","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Novel artificial intelligence algorithms for diabetic retinopathy and diabetic macular edema. 针对糖尿病视网膜病变和糖尿病黄斑水肿的新型人工智能算法。
IF 4.2 1区 医学
Eye and Vision Pub Date : 2024-06-17 DOI: 10.1186/s40662-024-00389-y
Jie Yao, Joshua Lim, Gilbert Yong San Lim, Jasmine Chiat Ling Ong, Yuhe Ke, Ting Fang Tan, Tien-En Tan, Stela Vujosevic, Daniel Shu Wei Ting
{"title":"Novel artificial intelligence algorithms for diabetic retinopathy and diabetic macular edema.","authors":"Jie Yao, Joshua Lim, Gilbert Yong San Lim, Jasmine Chiat Ling Ong, Yuhe Ke, Ting Fang Tan, Tien-En Tan, Stela Vujosevic, Daniel Shu Wei Ting","doi":"10.1186/s40662-024-00389-y","DOIUrl":"10.1186/s40662-024-00389-y","url":null,"abstract":"<p><strong>Background: </strong>Diabetic retinopathy (DR) and diabetic macular edema (DME) are major causes of visual impairment that challenge global vision health. New strategies are needed to tackle these growing global health problems, and the integration of artificial intelligence (AI) into ophthalmology has the potential to revolutionize DR and DME management to meet these challenges.</p><p><strong>Main text: </strong>This review discusses the latest AI-driven methodologies in the context of DR and DME in terms of disease identification, patient-specific disease profiling, and short-term and long-term management. This includes current screening and diagnostic systems and their real-world implementation, lesion detection and analysis, disease progression prediction, and treatment response models. It also highlights the technical advancements that have been made in these areas. Despite these advancements, there are obstacles to the widespread adoption of these technologies in clinical settings, including regulatory and privacy concerns, the need for extensive validation, and integration with existing healthcare systems. We also explore the disparity between the potential of AI models and their actual effectiveness in real-world applications.</p><p><strong>Conclusion: </strong>AI has the potential to revolutionize the management of DR and DME, offering more efficient and precise tools for healthcare professionals. However, overcoming challenges in deployment, regulatory compliance, and patient privacy is essential for these technologies to realize their full potential. Future research should aim to bridge the gap between technological innovation and clinical application, ensuring AI tools integrate seamlessly into healthcare workflows to enhance patient outcomes.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"23"},"PeriodicalIF":4.2,"publicationDate":"2024-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11181581/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141330701","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Preliminary study of cyclosporine A/Lifitegrast subconjunctival sustained-release drug membrane in the treatment of dry eyes. 环孢素 A/Lifitegrast 结膜下缓释药物膜治疗干眼症的初步研究。
IF 4.2 1区 医学
Eye and Vision Pub Date : 2024-06-13 DOI: 10.1186/s40662-024-00390-5
Jie Yang, Miao Chen, Fangyuan Wu, Jingjing Zuo, Huixiang Ma
{"title":"Preliminary study of cyclosporine A/Lifitegrast subconjunctival sustained-release drug membrane in the treatment of dry eyes.","authors":"Jie Yang, Miao Chen, Fangyuan Wu, Jingjing Zuo, Huixiang Ma","doi":"10.1186/s40662-024-00390-5","DOIUrl":"10.1186/s40662-024-00390-5","url":null,"abstract":"<p><strong>Background: </strong>Dry eyes can cause discomfort. To treat dry eye disease, cyclosporine A (CsA) and Lifitegrast are two eye drugs approved by the U.S. Food and Drug Administration (FDA). However, frequent use of eye drops can be challenging and lead to poor compliance, especially in elderly patients. Therefore, this study aimed to develop a drug sustained-release vector and explore its therapeutic effect in animal models of dry eye.</p><p><strong>Methods: </strong>Firstly, drug membranes loaded with both CsA and Lifitegrast using a carrier called poly(lactate-co-ε-caprolactone) (P(LLA-CL)) were prepared and evaluated for their physicochemical properties, release behavior in vitro, and safety in vivo. Next, a rabbit dry eye model using a 0.1% benzalkonium chloride (BAC) solution was developed and treated by drug-loaded micro membranes. We observed and recorded conjunctival hyperemia, corneal staining, corneal edema, corneal neovascularization, conjunctival goblet cells and hematoxylin and eosin (H&E) staining. Finally, we detected the MUC5AC and MMP-9 by immunofluorescence staining and enzyme-linked immunosorbent assay (ELISA).</p><p><strong>Results: </strong>The composite film released both CsA and Lifitegrast for at least one month. Compared to the blank membrane group, conjunctival hyperemia, corneal fluorescein staining, corneal edema, corneal neovascularization and conjunctival goblet cells recovered faster in the drug membrane group, and the difference was statistically significant. At the molecular level, the drug membrane group showed an increase in mucin density and a significant anti-inflammatory effect.</p><p><strong>Conclusions: </strong>The implantation of CsA/Lifitegrast loaded P(LLA-CL) membrane under the subconjunctival of the rabbit eye is safe. The study suggests that this subconjunctival administration could be developed into a minimally invasive delivery system to help patients with dry eye disease who require multiple daily eyedrops but have poor compliance.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"22"},"PeriodicalIF":4.2,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11170774/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141316918","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of manual and artificial intelligence-automated choroidal thickness segmentation of optical coherence tomography imaging in myopic adults. 近视成人光学相干断层成像的脉络膜厚度人工分割与人工智能自动分割的比较。
IF 4.2 1区 医学
Eye and Vision Pub Date : 2024-06-03 DOI: 10.1186/s40662-024-00385-2
Zhi Wei Lim, Jonathan Li, Damon Wong, Joey Chung, Angeline Toh, Jia Ling Lee, Crystal Lam, Maithily Balakrishnan, Audrey Chia, Jacqueline Chua, Michael Girard, Quan V Hoang, Rachel Chong, Chee Wai Wong, Seang Mei Saw, Leopold Schmetterer, Noel Brennan, Marcus Ang
{"title":"Comparison of manual and artificial intelligence-automated choroidal thickness segmentation of optical coherence tomography imaging in myopic adults.","authors":"Zhi Wei Lim, Jonathan Li, Damon Wong, Joey Chung, Angeline Toh, Jia Ling Lee, Crystal Lam, Maithily Balakrishnan, Audrey Chia, Jacqueline Chua, Michael Girard, Quan V Hoang, Rachel Chong, Chee Wai Wong, Seang Mei Saw, Leopold Schmetterer, Noel Brennan, Marcus Ang","doi":"10.1186/s40662-024-00385-2","DOIUrl":"10.1186/s40662-024-00385-2","url":null,"abstract":"<p><strong>Background: </strong>Myopia affects 1.4 billion individuals worldwide. Notably, there is increasing evidence that choroidal thickness plays an important role in myopia and risk of developing myopia-related conditions. With the advancements in artificial intelligence (AI), choroidal thickness segmentation can now be automated, offering inherent advantages such as better repeatability, reduced grader variability, and less reliance for manpower. Hence, we aimed to evaluate the agreement between AI-automated and manual segmented measurements of subfoveal choroidal thickness (SFCT) using two swept-source optical coherence tomography (OCT) systems.</p><p><strong>Methods: </strong>Subjects aged ≥ 16 years, with myopia of ≥ 0.50 diopters in both eyes, were recruited from the Prospective Myopia Cohort Study in Singapore (PROMYSE). OCT scans were acquired using Triton DRI-OCT and PLEX Elite 9000. OCT images were segmented both automatically with an established SA-Net architecture and manually using a standard technique with adjudication by two independent graders. SFCT was subsequently determined based on the segmentation. The Bland-Altman plot and intraclass correlation coefficient (ICC) were used to evaluate the agreement.</p><p><strong>Results: </strong>A total of 229 subjects (456 eyes) with mean [± standard deviation (SD)] age of 34.1 (10.4) years were included. The overall SFCT (mean ± SD) based on manual segmentation was 216.9 ± 82.7 µm with Triton DRI-OCT and 239.3 ± 84.3 µm with PLEX Elite 9000. ICC values demonstrated excellent agreement between AI-automated and manual segmented SFCT measurements (PLEX Elite 9000: ICC = 0.937, 95% CI: 0.922 to 0.949, P < 0.001; Triton DRI-OCT: ICC = 0.887, 95% CI: 0.608 to 0.950, P < 0.001). For PLEX Elite 9000, manual segmented measurements were generally thicker when compared to AI-automated segmented measurements, with a fixed bias of 6.3 µm (95% CI: 3.8 to 8.9, P < 0.001) and proportional bias of 0.120 (P < 0.001). On the other hand, manual segmented measurements were comparatively thinner than AI-automated segmented measurements for Triton DRI-OCT, with a fixed bias of - 26.7 µm (95% CI: - 29.7 to - 23.7, P < 0.001) and proportional bias of - 0.090 (P < 0.001).</p><p><strong>Conclusion: </strong>We observed an excellent agreement in choroidal segmentation measurements when comparing manual with AI-automated techniques, using images from two SS-OCT systems. Given its edge over manual segmentation, automated segmentation may potentially emerge as the primary method of choroidal thickness measurement in the future.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"21"},"PeriodicalIF":4.2,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11145894/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141237149","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Corneal injury repair and the potential involvement of ZEB1. 角膜损伤修复和 ZEB1 的潜在参与。
IF 4.2 1区 医学
Eye and Vision Pub Date : 2024-06-01 DOI: 10.1186/s40662-024-00387-0
Lin Jin, Lijun Zhang, Chunxiao Yan, Mengxin Liu, Douglas C Dean, Yongqing Liu
{"title":"Corneal injury repair and the potential involvement of ZEB1.","authors":"Lin Jin, Lijun Zhang, Chunxiao Yan, Mengxin Liu, Douglas C Dean, Yongqing Liu","doi":"10.1186/s40662-024-00387-0","DOIUrl":"10.1186/s40662-024-00387-0","url":null,"abstract":"<p><p>The cornea, consisting of three cellular and two non-cellular layers, is the outermost part of the eyeball and frequently injured by external physical, chemical, and microbial insults. The epithelial-to-mesenchymal transition (EMT) plays a crucial role in the repair of corneal injuries. Zinc finger E-box binding homeobox 1 (ZEB1), an important transcription factor involved in EMT, is expressed in the corneal tissues. It regulates cell activities like migration, transformation, and proliferation, and thereby affects tissue inflammation, fibrosis, tumor metastasis, and necrosis by mediating various major signaling pathways, including transforming growth factor (TGF)-β. Dysfunction of ZEB1 would impair corneal tissue repair leading to epithelial healing delay, interstitial fibrosis, neovascularization, and squamous cell metaplasia. Understanding the mechanism underlying ZEB1 regulation of corneal injury repair will help us to formulate a therapeutic approach to enhance corneal injury repair.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"20"},"PeriodicalIF":4.2,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11143703/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141186240","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Efficacy of RCI001 as a therapeutic candidate of dry eye disease in a modified mixed dry eye model. RCI001 作为干眼症候选疗法在改良混合干眼症模型中的疗效。
IF 4.2 1区 医学
Eye and Vision Pub Date : 2024-06-01 DOI: 10.1186/s40662-024-00388-z
Young-Ho Jung, Young Ah Ku, Jayoon Moon, Seunghoon Kim, Jin Suk Ryu, Chang Ho Yoon, Myung Hee Chung, Yong Ho Kim, Mee Kum Kim, Dong Hyun Kim
{"title":"Efficacy of RCI001 as a therapeutic candidate of dry eye disease in a modified mixed dry eye model.","authors":"Young-Ho Jung, Young Ah Ku, Jayoon Moon, Seunghoon Kim, Jin Suk Ryu, Chang Ho Yoon, Myung Hee Chung, Yong Ho Kim, Mee Kum Kim, Dong Hyun Kim","doi":"10.1186/s40662-024-00388-z","DOIUrl":"10.1186/s40662-024-00388-z","url":null,"abstract":"<p><strong>Background: </strong>To evaluate the therapeutic effects of topical RCI001 (RCI) and compare its efficacy with that of 1% prednisolone acetate (PDE) and 5% Lifitegrast in a modified mixed dry eye disease (DED) model.</p><p><strong>Methods: </strong>The environmental DED model was induced in BALB/c mice in a dry chamber with scopolamine. The eyes of the mice were treated topically with phosphate buffered saline (PBS), PDE, Lifitegrast or RCI twice daily for 1 week. Ocular surface staining (OSS), tear secretion, inflammatory cytokines in the ocular surface and lacrimal gland, and immunofluorescence staining in the conjunctiva and cornea(CC) were assessed.</p><p><strong>Results: </strong>The RCI group demonstrated better improvement of OSS and tear secretion than the PBS group (OSS, PBS: 13.0 ± 1.6, RCI: 9.4 ± 3.0; tear secretion, PBS: 5.0 ± 0.4 mm, RCI: 7.0 ± 0.3 mm, each P < 0.001) and better clinical efficacy than PDE and Lifitegrast groups on Day 7 (improvement rate of OSS, RCI: 32.45%, Lifitegrast: 13.13%, PDE: 12.25%). The RCI group resulted in significantly lower expression of oxidative stress markers in the CC than the PBS group (4-HNE, NOX2, and NOX4 in the conjunctiva; NOX2 in the cornea, each P < 0.05). However, the PDE and Lifitegrast groups did not show significant differences compared with the PBS group. There were no significant differences of inflammatory cytokines in the ocular surface and lacrimal gland between all groups.</p><p><strong>Conclusion: </strong>Topical RCI001 showed excellent therapeutic effects in environmental DED models by stimulating tear secretion, modulating oxidative stress and improving corneal epithelial healing compared to 1% PDE and 5% Lifitegrast.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"19"},"PeriodicalIF":4.2,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11143567/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141186241","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Multi-modal imaging for the detection of early keratoconus: a narrative review. 用于检测早期角膜炎的多模态成像:综述。
IF 4.2 1区 医学
Eye and Vision Pub Date : 2024-05-11 DOI: 10.1186/s40662-024-00386-1
Muawyah Al Bdour, Hashem M Sabbagh, Hisham M Jammal
{"title":"Multi-modal imaging for the detection of early keratoconus: a narrative review.","authors":"Muawyah Al Bdour, Hashem M Sabbagh, Hisham M Jammal","doi":"10.1186/s40662-024-00386-1","DOIUrl":"10.1186/s40662-024-00386-1","url":null,"abstract":"<p><p>Keratoconus is a common progressive corneal disorder that can be associated with significant ocular morbidity. Various corneal imaging techniques have been used for the diagnosis of established cases. However, in the early stages of the disease, which include subclinical keratoconus and forme fruste keratoconus, detection of such cases can be challenging. The importance of detecting such cases is very important because early intervention can halt disease progression, improve visual outcomes and prevent postrefractive surgery ectasia associated with performing corneal refractive procedures in such patients. This narrative review aimed to examine several established and evolving imaging techniques for the detection of early cases of keratoconus. The utilization of combinations of these techniques may further increase their diagnostic ability.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"18"},"PeriodicalIF":4.2,"publicationDate":"2024-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11088107/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140904322","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信