Efficacy of orthokeratology lens with the modified small treatment zone on myopia progression and visual quality: a randomized clinical trial.

IF 4.1 1区 医学 Q1 OPHTHALMOLOGY
Ganyu Gong, Bi Ning Zhang, Tengyou Guo, Guoying Liu, Ju Zhang, Xiu Juan Zhang, Xianli Du
{"title":"Efficacy of orthokeratology lens with the modified small treatment zone on myopia progression and visual quality: a randomized clinical trial.","authors":"Ganyu Gong, Bi Ning Zhang, Tengyou Guo, Guoying Liu, Ju Zhang, Xiu Juan Zhang, Xianli Du","doi":"10.1186/s40662-024-00403-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To evaluate the long-term effectiveness of orthokeratology (ortho-K) lenses with small treatment zone (STZ) or conventional treatment zone (CTZ) in controlling axial elongation in children with myopia as well as the impact on visual quality. We also sought to determine the effect of retinal visual signal quality on axial elongation.</p><p><strong>Methods: </strong>This is a prospective randomized controlled study. A total of 140 participants (age ranging from 8 to 12 years) were randomly assigned to wear either STZ or CTZ ortho-K lenses. STZ ortho-K lenses design was achieved by changing the depth of reverse zone and the sagitta height of the optical zone. Using the IOL-Master 500, axial length (AL) was measured at baseline and after 6, 12 and 18 months of ortho-K treatment. Spherical aberration (SA) and corneal topographic parameters were obtained by the Pentacam anterior segment analyzer at baseline and the 1-month follow-up visit, and optical qualities were assessed by optical quality analysis system-II (OQAS-II) at baseline and after 1 month of lens wearing. Optical quality parameters mainly included the modulation transfer function (MTF) cutoff, Strehl ratio (SR), objective scattering index (OSI), and predicted visual acuity (PVA).</p><p><strong>Results: </strong>A total of 131 participants completed the study, including 68 in the STZ group and 63 in the CTZ group. The STZ group had significantly reduced AL elongation compared to the CTZ group after treatment (12 months: 0.07 ± 0.11 mm vs. 0.14 ± 0.12 mm, P = 0.002; 18 months: 0.17 ± 0.15 mm vs. 0.26 ± 0.16 mm, P = 0.002). The topography in the STZ group showed a smaller treatment zone (TZ) diameter (2.50 ± 0.23 mm vs. 2.77 ± 0.18 mm, P < 0.001), a wider defocus ring width (2.45 ± 0.28 mm vs. 2.30 ± 0.30 mm, P = 0.006), and larger values of total amount of defocus (119.38 ± 63.71 D·mm<sup>2</sup> vs. 91.40 ± 40.83 D·mm<sup>2</sup>, P = 0.003) and total SA (0.37 ± 0.25 μm vs. 0.25 ± 0.29 μm, P = 0.015), compared with the CTZ group. Objective visual quality decreased in both groups (P < 0.001). This was evidenced by a greater decrease in MTF cutoff (- 14.24 ± 10.48 vs. - 10.74 ± 9.46, P = 0.047) and SR values (- 0.09 ± 0.07 vs. - 0.06 ± 0.07, P = 0.026), and an increase in OSI value (0.84 ± 0.72 vs. 0.58 ± 0.53, P = 0.019). PVA9% decreased significantly in the STZ group but not the CTZ group. A statistically significant negative correlation was found between the changes in total SA and MTF cutoff values (r =  - 0.202, P = 0.025). AL changes were associated with sex, change of MTF cutoff value, increment of total SA and TZ area.</p><p><strong>Conclusions: </strong>Compared with CTZ ortho-K lenses, STZ ortho-K lenses significantly inhibited axial elongation in children with myopia while moderately reducing their objective visual quality. Axial elongation was affected by retinal visual quality, and it may be a possible mechanism for ortho-K slowing myopia progression. Trial registration This trial is registered at Chinese Clinical Trial Registry on November 5, 2019 with trial registration number: ChiCTR1900027218. https://www.chictr.org.cn/showproj.html?proj=45380.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"35"},"PeriodicalIF":4.1000,"publicationDate":"2024-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11367740/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Vision","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-024-00403-3","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To evaluate the long-term effectiveness of orthokeratology (ortho-K) lenses with small treatment zone (STZ) or conventional treatment zone (CTZ) in controlling axial elongation in children with myopia as well as the impact on visual quality. We also sought to determine the effect of retinal visual signal quality on axial elongation.

Methods: This is a prospective randomized controlled study. A total of 140 participants (age ranging from 8 to 12 years) were randomly assigned to wear either STZ or CTZ ortho-K lenses. STZ ortho-K lenses design was achieved by changing the depth of reverse zone and the sagitta height of the optical zone. Using the IOL-Master 500, axial length (AL) was measured at baseline and after 6, 12 and 18 months of ortho-K treatment. Spherical aberration (SA) and corneal topographic parameters were obtained by the Pentacam anterior segment analyzer at baseline and the 1-month follow-up visit, and optical qualities were assessed by optical quality analysis system-II (OQAS-II) at baseline and after 1 month of lens wearing. Optical quality parameters mainly included the modulation transfer function (MTF) cutoff, Strehl ratio (SR), objective scattering index (OSI), and predicted visual acuity (PVA).

Results: A total of 131 participants completed the study, including 68 in the STZ group and 63 in the CTZ group. The STZ group had significantly reduced AL elongation compared to the CTZ group after treatment (12 months: 0.07 ± 0.11 mm vs. 0.14 ± 0.12 mm, P = 0.002; 18 months: 0.17 ± 0.15 mm vs. 0.26 ± 0.16 mm, P = 0.002). The topography in the STZ group showed a smaller treatment zone (TZ) diameter (2.50 ± 0.23 mm vs. 2.77 ± 0.18 mm, P < 0.001), a wider defocus ring width (2.45 ± 0.28 mm vs. 2.30 ± 0.30 mm, P = 0.006), and larger values of total amount of defocus (119.38 ± 63.71 D·mm2 vs. 91.40 ± 40.83 D·mm2, P = 0.003) and total SA (0.37 ± 0.25 μm vs. 0.25 ± 0.29 μm, P = 0.015), compared with the CTZ group. Objective visual quality decreased in both groups (P < 0.001). This was evidenced by a greater decrease in MTF cutoff (- 14.24 ± 10.48 vs. - 10.74 ± 9.46, P = 0.047) and SR values (- 0.09 ± 0.07 vs. - 0.06 ± 0.07, P = 0.026), and an increase in OSI value (0.84 ± 0.72 vs. 0.58 ± 0.53, P = 0.019). PVA9% decreased significantly in the STZ group but not the CTZ group. A statistically significant negative correlation was found between the changes in total SA and MTF cutoff values (r =  - 0.202, P = 0.025). AL changes were associated with sex, change of MTF cutoff value, increment of total SA and TZ area.

Conclusions: Compared with CTZ ortho-K lenses, STZ ortho-K lenses significantly inhibited axial elongation in children with myopia while moderately reducing their objective visual quality. Axial elongation was affected by retinal visual quality, and it may be a possible mechanism for ortho-K slowing myopia progression. Trial registration This trial is registered at Chinese Clinical Trial Registry on November 5, 2019 with trial registration number: ChiCTR1900027218. https://www.chictr.org.cn/showproj.html?proj=45380.

改良小治疗区角膜塑形镜对近视发展和视觉质量的影响:随机临床试验。
背景:目的:评估小治疗区(STZ)或传统治疗区(CTZ)角膜塑形镜(ortho-K)在控制近视儿童轴伸长方面的长期有效性,以及对视觉质量的影响。我们还试图确定视网膜视觉信号质量对轴伸长的影响:这是一项前瞻性随机对照研究。共有 140 名参与者(年龄在 8 至 12 岁之间)被随机分配配戴 STZ 或 CTZ 角膜矫形镜。STZ 角膜塑形镜的设计是通过改变反向区的深度和光学区的矢状高度来实现的。使用 IOL-Master 500 测量基线时以及瘢痕矫形治疗 6、12 和 18 个月后的轴向长度(AL)。球差(SA)和角膜地形图参数由 Pentacam 前节分析仪在基线和 1 个月随访时获得,光学质量由光学质量分析系统-II(OQAS-II)在基线和戴镜 1 个月后进行评估。光学质量参数主要包括调制传递函数(MTF)截止值、斯特雷尔比(SR)、客观散射指数(OSI)和预测视力(PVA):共有 131 人完成了研究,其中 STZ 组 68 人,CTZ 组 63 人。与 CTZ 组相比,STZ 组在治疗后 AL 伸长明显减少(12 个月:0.07 ± 0.11 mm):0.07 ± 0.11 mm vs. 0.14 ± 0.12 mm,P = 0.002;18 个月:18个月:0.17 ± 0.15 mm vs. 0.26 ± 0.16 mm,P = 0.002)。与 CTZ 组相比,STZ 组的地形图显示治疗区 (TZ) 直径(2.50 ± 0.23 mm vs. 2.77 ± 0.18 mm,P 2 vs. 91.40 ± 40.83 D-mm2,P = 0.003)和总 SA(0.37 ± 0.25 μm vs. 0.25 ± 0.29 μm,P = 0.015)更小。两组的客观视觉质量都有所下降(P 结论:两组的客观视觉质量都有所下降:与 CTZ 角膜矫形镜相比,STZ 角膜矫形镜能显著抑制近视儿童的轴伸长,同时适度降低其客观视觉质量。轴伸长受视网膜视觉质量的影响,这可能是ok镜延缓近视发展的一个机制。试验注册 本试验于2019年11月5日在中国临床试验注册中心注册,试验注册号为:ChiCTR1900027218:https://www.chictr.org.cn/showproj.html?proj=45380。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Eye and Vision
Eye and Vision OPHTHALMOLOGY-
CiteScore
8.60
自引率
2.40%
发文量
89
审稿时长
15 weeks
期刊介绍: Eye and Vision is an open access, peer-reviewed journal for ophthalmologists and visual science specialists. It welcomes research articles, reviews, methodologies, commentaries, case reports, perspectives and short reports encompassing all aspects of eye and vision. Topics of interest include but are not limited to: current developments of theoretical, experimental and clinical investigations in ophthalmology, optometry and vision science which focus on novel and high-impact findings on central issues pertaining to biology, pathophysiology and etiology of eye diseases as well as advances in diagnostic techniques, surgical treatment, instrument updates, the latest drug findings, results of clinical trials and research findings. It aims to provide ophthalmologists and visual science specialists with the latest developments in theoretical, experimental and clinical investigations in eye and vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信