{"title":"Relationship between Brain Natriuretic Peptide and Thromboembolic Events in Elderly Patients with Nonvalvular Atrial Fibrillation","authors":"Hongxia Wang, Jiajun Huang, Wenxi Gu, Xiaojiao Hao, Guiru Li, Yumin Yuan, Yingmin Lu","doi":"10.1155/2024/5594637","DOIUrl":"https://doi.org/10.1155/2024/5594637","url":null,"abstract":"<i>Objective</i>. To investigate the relationship between brain natriuretic peptide (BNP) and thromboembolic events in elderly patients with nonvalvular atrial fibrillation (NVAF). <i>Methods</i>. This is a prospective cohort study, and based on the inclusion and exclusion criteria, 180 elderly patients with NVAF were included. The patients received follow-up appointments in the clinic or by telephone every 6 months after the beginning of the study. The primary follow-up endpoints were thromboembolic and atherosclerotic events, including ischaemic stroke, myocardial infarction, and systemic embolism. The secondary endpoints were adverse events, including cardiovascular death, all-cause death, and hospitalisation for heart failure. Patients were divided into three groups according to their BNP level at admission: group A (BNP ≤334.5 pg/mL), group B (BNP = 334.5–1,288 pg/mL), and group C (BNP ≥1,288 pg/mL). <i>Results</i>. A total of 180 patients were enrolled in this study, with 50 patients in group A, 68 in group B, and 62 in group C. Compared with groups A and B, group C had a higher CHA2DS2-VASc score (<i>Z</i> = 15.142; <span><svg height=\"8.8423pt\" style=\"vertical-align:-0.2064009pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 19.289 8.8423\" width=\"19.289pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"></path></g><g transform=\"matrix(.013,0,0,-0.013,11.658,0)\"></path></g></svg><span></span><span><svg height=\"8.8423pt\" style=\"vertical-align:-0.2064009pt\" version=\"1.1\" viewbox=\"22.8711838 -8.6359 28.182 8.8423\" width=\"28.182pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,22.921,0)\"></path></g><g transform=\"matrix(.013,0,0,-0.013,29.161,0)\"></path></g><g transform=\"matrix(.013,0,0,-0.013,32.125,0)\"><use xlink:href=\"#g113-49\"></use></g><g transform=\"matrix(.013,0,0,-0.013,38.365,0)\"><use xlink:href=\"#g113-49\"></use></g><g transform=\"matrix(.013,0,0,-0.013,44.605,0)\"></path></g></svg>)</span></span> and a lower ejection fraction (EF) value (<i>Z</i> = 119.893; <span><svg height=\"8.8423pt\" style=\"vertical-align:-0.2064009pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 19.289 8.8423\" width=\"19.289pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"><use xlink:href=\"#g113-81\"></use></g><g transform=\"matrix(.013,0,0,-0.013,11.658,0)\"><use xlink:href=\"#g117-34\"></use></g></svg><span></span><span><svg height=\"8.8423pt\" style=\"vertical-align:-0.2064009pt\" version=\"1.1\" viewbox=\"22.8711838 -8.6359 28.182 8.8423\" width=\"28.182pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,22.921,0)\"><use xlink:href=\"#g113-49\"></use></g><g transform=\"matrix(.013,0,0,-0.013,29.161,0)\"><use xlink:href=\"#g113-47\"></use></g><g transform=\"matrix(.013,0,0,-0.013,32.125,0)\"><use xlink:href=\"#g113-49\"","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"11 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2024-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139480921","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mohammad Hossein Nikoo, Mohammad Zarrabi, Alireza Moaref, Iman Razeghian-Jahromi
{"title":"Global Longitudinal Strain May Be the One that Appropriately Identifies Candidates of ICD Implantation","authors":"Mohammad Hossein Nikoo, Mohammad Zarrabi, Alireza Moaref, Iman Razeghian-Jahromi","doi":"10.1155/2024/2214072","DOIUrl":"https://doi.org/10.1155/2024/2214072","url":null,"abstract":"Hypertrophic cardiomyopathy (HCM) significantly contributes to an elevated risk of sudden cardiac death. Primary prevention is implemented by using an implantable cardioverter defibrillator (ICD). However, all of the HCM patients do not really need ICD therapy. Providing a superior index for ICD indication compared with the current indices like ejection fraction is essential to differentiate high-risk patients efficiently. The present study assessed the potential of global longitudinal strain (GLS) for the differentiation of HCM patients based on their need for ICD shocks. Patients with HCM were considered in four defined centers between March and June 2021. Those with previous ICD implantation or current candidates for ICD therapy were included in the study. Participants were subjected to speckle-tracking echocardiography, and GLS as well as some other echocardiographic parameters were recorded. Afterwards, data from implanted ICDs were extracted. Patients who received ICD shocks (appropriate) due to ventricular tachycardia (VT)/ventricular fibrillation (VF) were categorized in group A. The remaining patients were constituted group B who received inappropriate shocks, i.e., other than VT/VF. Overall, 34 patients were found eligible to participate with a mean age of 62 ± 16.1 years including 64.7% of males. Among a variety of echocardiographic parameters, GLS was the sole one that was significantly higher in group A compared with that in group B. Our findings revealed that only GLS could predict fatal arrhythmias. To substantiate, the odds of VT were raised by 43% with a single increase in GLS unit. GLS showed the highest accuracy for ICD indication among HCM patients and, therefore, could be a solid and early criterion to predict the incidence of life-threatening arrhythmias. In this regard, identifying appropriate HCM patients with respect to their need for ICD therapy is feasible.","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"10 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2024-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139474624","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Boyoung Joung, Myung Hwan Bae, Il-Young Oh, Hyung-Seob Park, Jaemin Shim, Min Soo Cho, Jung Myung Lee, Eue-Keun Choi, Young Soo Lee
{"title":"Performance and Physician Experience of INGEVITY+ Active Fixation Leads: Prospective INGEVITY+ Lead Clinical Study in Korea","authors":"Boyoung Joung, Myung Hwan Bae, Il-Young Oh, Hyung-Seob Park, Jaemin Shim, Min Soo Cho, Jung Myung Lee, Eue-Keun Choi, Young Soo Lee","doi":"10.1155/2024/2172306","DOIUrl":"https://doi.org/10.1155/2024/2172306","url":null,"abstract":"<i>Background</i>. Boston Scientific INGEVITY+ pacing lead (Boston Scientific, Marlborough, MA, USA) has been upgraded to INGEVITY. The performance of the INGEVITY+ pacing lead has not yet been reported. This study aimed to evaluate the short- and long-term safety, effectiveness, and handling experience of INGEVITY+ leads. <i>Methods</i>. Consecutive patients were included from 9 institutions in Korea, where 400 leads (200 right ventricular active fixation leads and 200 right atrial active fixation leads) were implanted or attempted in 200 subjects. <i>Results</i>. During the implantation, only one patient required a lead change because of lead screw failure. The handling questionnaires of the lead received very positive feedback with 88% of operators agreeing that it is easy for leads to pass through small vessels or vessels with multiple leads. At the 3-month follow-up, 95.7% of RA leads and 99.5% of RV leads had pacing thresholds less than 1.5 V. A total of 92.4% of atrial leads had amplitudes greater than 1.5 mV, and 96.5% of ventricular leads had sensing amplitudes greater than 5 mV at 3 months. A total of 99.8% had impedances between 300 and 1,300 ohms. The lead-related complication-free rate for all leads during follow-up was 100%, and the overall rates of lead dislodgment, perforation, and pericardial effusion were all 0.0%. <i>Conclusions</i>. The INGEVITY+ pacing lead exhibited exceptional clinical performance, with a high complication-free rate throughout the 3-month follow-up period. In addition, the lead displayed excellent electrical characteristics, and the lead-handling experience was reported to be very good.","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"4 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2024-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139423789","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Fengqi Xuan, Zhongyin Zuo, Jie Zhang, Shibei Zhang, Zichen Liu, Yunfan Meng, Kuo Sun, Yaling Han, Ming Liang, Zulu Wang
{"title":"Guidewire Ablation within the Coronary Venous System for Epicardial or Intramural Ventricular Arrhythmia: A Preclinical Study of Biophysical Characterization","authors":"Fengqi Xuan, Zhongyin Zuo, Jie Zhang, Shibei Zhang, Zichen Liu, Yunfan Meng, Kuo Sun, Yaling Han, Ming Liang, Zulu Wang","doi":"10.1155/2024/4412758","DOIUrl":"https://doi.org/10.1155/2024/4412758","url":null,"abstract":"<i>Background</i>. Catheter ablation failure poses a clinical challenge for epicardial or intramural ventricular arrhythmia (VA); however, guidewire ablation within the coronary venous system (CVS) may be effective and safe for targeting VAs. <i>Methods</i>. The ex vivo phase included four steps. In step 1, the steam pop incidence rates during guidewire ablation at power settings of 5, 10, 15, 20, and 25 W were analyzed using 10 mm- and 20 mm-tip guidewires. In step 2, guidewire ablation was performed for application durations of 10, 20, 30, 40, 50, 60, and 90 s, and the lesion size was measured. In step 3, the effects of saline infusion (0, 1, 2, 3, and 4 mL/min) on lesion dimensions and steam pop formation were examined. In step 4, an orthogonal array was constructed to obtain the optimal guidewire ablation parameters. In the <i>in vivo</i> phase, guidewire ablation within the CVS was performed in three dogs, and the lesion features in 10 days after ablation were observed. <i>Results</i>. In step 1, the steam pop incidence rates at 5, 10, 15, 20, and 25 W were 0%, 0%, 12.5%, 62.5%, and 100% using the 10 mm-tip guidewires and 0%, 0%, 0%, 25%, and 75% using the 20 mm-tip guidewires, respectively. In step 2, we found that the lesion areas increased with an increase in the ablation duration (the maximum lesion diameters at 30, 60, and 90 s were 4.9 ± 0.4, 7.0 ± 0.8, and 9.2 ± 0.7 mm in the 10 mm group and 3.2 ± 0.5, 4.5 ± 0.4, and 5.3 ± 0.7 mm in the 20 mm-tip group, respectively). In step 3, we observed that saline infusion was negatively correlated with ablation lesions but had a lower risk of steam pop. The optimal parameters for the 20 mm-tip guidewire ablation were 15 W, 50 s, and 2 mL/min or 20 W, 70 s, and 2 mL/min. In the <i>in vivo</i> phase, effective ablation lesions with maximum and minimum diameters of 3.2 ± 0.3 and 2.8 ± 0.5 mm, respectively, were created by the guidewires during the 10-day observation period after ablation. <i>Conclusion</i>. This novel radiofrequency guidewire ablation technique can feasibly create effective lesions within the CVS, which may improve the efficacy of catheter ablation for challenging epicardial or intramural VA.","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"9 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2024-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139093738","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Truls Råmunddal, Christian Dworeck, Petronella Torild, Sofie Andréen, Li-Ming Gan, Geir Hirlekar, Dan Ioanes, Anna Myredal, Jacob Odenstedt, Petur Petursson, Tetiana Pylova, Fanny Töpel, Sebastian Völz, Mats Hilmersson, Björn Redfors, Oskar Angerås
{"title":"Safety and Feasibility Using a Fluid-Filled Wire to Avoid Hydrostatic Errors in Physiological Intracoronary Measurements","authors":"Truls Råmunddal, Christian Dworeck, Petronella Torild, Sofie Andréen, Li-Ming Gan, Geir Hirlekar, Dan Ioanes, Anna Myredal, Jacob Odenstedt, Petur Petursson, Tetiana Pylova, Fanny Töpel, Sebastian Völz, Mats Hilmersson, Björn Redfors, Oskar Angerås","doi":"10.1155/2024/6664482","DOIUrl":"https://doi.org/10.1155/2024/6664482","url":null,"abstract":"<i>Background</i>. Using a fluid-filled wire with a pressure sensor outside the patient compared to a conventional pressure wire may avoid the systematic error introduced by the hydrostatic pressure within the coronary circulation. <i>Aims</i>. To assess the safety and effectiveness of the novel fluid-filled wire, Wirecath (Cavis Technologies, Uppsala, Sweden), as well as its ability to avoid the hydrostatic pressure error. <i>Methods and Results</i>. The Wirecath pressure wire was used in 45 eligible patients who underwent invasive coronary angiography and had a clinical indication for invasive coronary pressure measurement at Sahlgrenska University Hospital, Gothenburg, Sweden. In 29 patients, a simultaneous measurement was performed with a conventional coronary pressure wire (PressureWire X, Abbott Medical, Plymouth, MN, USA), and in 19 patients, the vertical height difference between the tip of the guide catheter and the wire measure point was measured in a 90-degree lateral angiographic projection. No adverse events caused by the pressure wires were reported. The mean Pd/Pa and mean FFR using the fluid-filled wire and the sensor-tipped wire differed significantly; however, after correcting for the hydrostatic effect, the sensor-tipped wire pressure correlated well with the fluid-filled wire pressure (<i>R</i> = 0.74 vs. <i>R</i> = 0.89 at rest and <i>R</i> = 0.89 vs. <i>R</i> = 0.98 at hyperemia). <i>Conclusion</i>. Hydrostatic errors in physiologic measurements can be avoided by using the fluid-filled Wirecath wire, which was safe to use in the present study. This trial is registered with NCT04776577 and NCT04802681.","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"38 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2024-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139078834","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Eline Wu, Ali Mahdi, Jannike Nickander, Judith Bruchfeld, Linda Mellbin, Kristina Haugaa, Marcus Ståhlberg, Liyew Desta
{"title":"Enhanced External Counterpulsation for Management of Postacute Sequelae of SARS-CoV-2 Associated Microvascular Angina and Fatigue: An Interventional Pilot Study","authors":"Eline Wu, Ali Mahdi, Jannike Nickander, Judith Bruchfeld, Linda Mellbin, Kristina Haugaa, Marcus Ståhlberg, Liyew Desta","doi":"10.1155/2023/6687803","DOIUrl":"https://doi.org/10.1155/2023/6687803","url":null,"abstract":"<i>Background</i>. Postacute sequelae of SARS-CoV-2 infection (PASC) are a novel clinical syndrome characterized in part by endothelial dysfunction. Enhanced external counterpulsation (EECP) produces pulsatile shear stress, which has been associated with improvements in systemic endothelial function. <i>Objective</i>. To explore the effects of EECP on symptom burden, physical capacity, mental health, and health-related quality of life (HRQoL) in patients with PASC-associated angina and microvascular dysfunction (MVD). <i>Methods</i>. An interventional pilot study was performed, including 10 patients (male = 5, mean age 50.3 years) recruited from a tertiary specialized PASC clinic. Patients with angina and MVD, defined as index of microcirculatory resistance (IMR) ≥25 and/or diagnosed through stress perfusion cardiac magnetic resonance imaging, were included. Patients underwent one modified EECP course (15 one-hour sessions over five weeks). Symptom burden, six-minute walk test, and validated generic self-reported instruments for measuring psychological distress and HRQoL were assessed before and one month after treatment. <i>Results</i>. At baseline, most commonly reported PASC symptoms were angina (100%), fatigue (80%), and dyspnea (80%). Other symptoms included palpitations (50%), concentration impairment (50%), muscle pain (30%), and brain fog (30%). Mean IMR was 63.6. After EECP, 6MWD increased (mean 29.5 m, median 21 m) and angina and fatigue improved. Mean depression scores showed reduced symptoms (−0.8). Mean HRQoL scores improved in seven out of eight subscales (+0.2 to 10.5). <i>Conclusions</i>. Patients with PASC-associated angina and evidence of MVD experienced subjective and objective benefits from EECP. The treatment was well-tolerated. These findings warrant controlled studies in a larger cohort.","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"28 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2023-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139056116","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Relationship between Coronary Artery Calcium Score and Coronary Stenosis","authors":"Xinyan Chen, Jianbin Zhao, Qingqing Cai, Rong Chen, Wenhao Wu, Peng Wang, Gaoxing Zhang, Jinhuan Zhen","doi":"10.1155/2023/5538111","DOIUrl":"https://doi.org/10.1155/2023/5538111","url":null,"abstract":"<i>Background</i>. The coronary artery calcium score (CACS) is commonly employed to quantify the degree of calcification in coronary atherosclerosis. Indeed, increased coronary stenosis severity is associated with a progressive increase in CACS. <i>Objectives</i>. This study sought to explore the association between CACS and coronary stenosis of ≥50% and ≥70%. <i>Methods</i>. We conducted a retrospective analysis of patient data collected between July 1, 2017, and March 3, 2022, at Jiangmen Central Hospital. A total of 208 patients, presenting with both symptomatic and asymptomatic manifestations and suspected coronary artery disease (CAD), were included. Statistical analyses included ROC curve assessments, subgroup analyses based on age, and comparisons of CACS values against the presence of coronary stenosis ≥50% and ≥70%. <i>Results</i>. Ultimately, 208 patients were included, with a median age of 65.0 years and a median CACS of 115.7 (interquartile range: 13.7–369.4). A CACS threshold of ≥1300 demonstrated a specificity of 100% for coronary stenosis of ≥50%. Notably, the percentage of patients with obstructive CAD showing CACS = 0 was significantly higher in those under 65 years (15.1%) compared to patients over 65 years (3.8%) (<span><svg height=\"8.8423pt\" style=\"vertical-align:-0.2064009pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 19.289 8.8423\" width=\"19.289pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"></path></g><g transform=\"matrix(.013,0,0,-0.013,11.658,0)\"></path></g></svg><span></span><span><svg height=\"8.8423pt\" style=\"vertical-align:-0.2064009pt\" version=\"1.1\" viewbox=\"22.8711838 -8.6359 28.182 8.8423\" width=\"28.182pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,22.921,0)\"></path></g><g transform=\"matrix(.013,0,0,-0.013,29.161,0)\"></path></g><g transform=\"matrix(.013,0,0,-0.013,32.125,0)\"><use xlink:href=\"#g113-49\"></use></g><g transform=\"matrix(.013,0,0,-0.013,38.365,0)\"><use xlink:href=\"#g113-49\"></use></g><g transform=\"matrix(.013,0,0,-0.013,44.605,0)\"></path></g></svg>).</span></span> The inflection point, at which the risk probability for coronary stenosis of ≥50% shifted from being a protective factor to a risk factor, was observed when CACS fell within the range of 63.3 to 66.0. <i>Conclusion</i>. CACS demonstrates good performance for the detection of coronary artery stenosis.","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"9 11 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138688293","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yi Wang, Yanxiang Liu, Lu Liu, Liqiong Hong, Huimin Chen
{"title":"Comparative Analysis of Hypertension Guidelines: Unveiling Consensus and Discrepancies in Lifestyle Modifications for Blood Pressure Control","authors":"Yi Wang, Yanxiang Liu, Lu Liu, Liqiong Hong, Huimin Chen","doi":"10.1155/2023/5586403","DOIUrl":"https://doi.org/10.1155/2023/5586403","url":null,"abstract":"<i>Background</i>. Hypertension is a major global health concern, and lifestyle modifications have been recommended as first-line treatment for hypertension in many guidelines. However, different guidelines may recommend different types of lifestyle adjustment, and it is unclear which ones are most effective. In this review, we compared hypertension guidelines to identify any differences and/or consensus in content, efficacy, and timing of initiation of lifestyle modifications. <i>Methods</i>. We conducted a search of databases to identify hypertension guidelines available in English. We extracted and compared information about lifestyle modifications recommended by the guidelines. <i>Results</i>. Five hypertension guidelines from America, Europe, the UK, Canada, and the International Society of Hypertension are included. They all recommend diet adaptation, sodium reduction, alcohol restriction, physical exercise, and weight reduction. Other lifestyle interventions emphasized by some guidelines, such as potassium supplementation, smoking cessation, and stress management, are not recommended by all the five guidelines. Among lifestyle changes, the dietary approaches to stop hypertension (DASH) diet may be considered the most effective treatment for reducing blood pressure. These guidelines recommend that for patients with high-normal blood pressure or grade 1 hypertension without high risk factors, lifestyle medicine should be used first for 3–6 months, if blood pressure is still not controlled, then start medication. For those patients who need drug treatment, lifestyle changes can also enhance the effects of antihypertensive therapy. <i>Conclusion</i>. Lifestyle modifications are crucial in the treatment of hypertension and should be recommended to most hypertensive patients. Among these lifestyle interventions, diet adaptation containing low sodium and alcohol restriction may be the most effective in reducing blood pressure. Physical exercise and weight reduction are also recommended. In some cases, lifestyle modifications should be tried first. They may also enhance the effects of antihypertensive drugs in other patients.","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"1 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2023-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138575701","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Hailan Liu, Lili Chen, Yan Song, Yingying Xu, Chunquan Zhang
{"title":"Evaluation of Left Atrial Function in Patients with Paroxysmal Atrial Fibrillation Using Left Atrial Automatic Myocardial Functional Imaging Ultrasonography.","authors":"Hailan Liu, Lili Chen, Yan Song, Yingying Xu, Chunquan Zhang","doi":"10.1155/2023/6924570","DOIUrl":"https://doi.org/10.1155/2023/6924570","url":null,"abstract":"<p><strong>Aim: </strong>To evaluate volume and strain of the left atrium (LA) in people suffering from paroxysmal atrial fibrillation which is not valvular (NVPAF) using the new technology of left atrial automatic myocardial function imaging (AFILA) and to analyze prognostic factors in patients with NVPAF by follow-up.</p><p><strong>Methods: </strong>Between August 2019 and August 2022, a total of 80 NVPAF patients and 60 normal control patients who were hospitalized in the Department of Cardiology were included in the study. The LA volume and strain parameters of the two groups were analyzed. The differences in LA function (LAF) parameters were compared between the two groups to generate the receiver operating characteristic curve (ROC) and calculate the area under the curve (AUC), sensitivity, and specificity of each parameter. Follow-up was conducted on the 80 NVPAF patients included, their treatment methods after admission and their rehospitalization due to heart events were recorded, and independent risk factors influencing the prognosis of NVPAF were obtained.</p><p><strong>Results: </strong>A total of 140 patients participated in the study, including 80 in the NVPAF group and 60 in the normal control group. There was no statistically significant difference in age and sex between the two groups. Compared to the normal group, the LA minimum volume (LAVmin), LA maximum volume (LAVmax), and volume at onset of LA contraction (LAVpreA) in the NVPAF group were significantly increased. The LA emptying fraction (LAEF) was significantly decreased, and LA reservoir strain (S_R), LA conduit strain (S_CD), and LA contractile strain (S_CT) were significantly compromised (<i>P</i> < 0.05). There was no significant difference in LA evacuation volume (LAEV) reduction (<i>P</i> > 0.05). Logistic regression analysis of LAF parameters in NVPAF patients showed that LAEF and S_R were independently correlated with NVPAF (odds ratio values: 0.883 (0.827-0.943), <i>P</i> < 0.001; 0.916 (0.569-1.474), <i>P</i> = 0.047). The ROC curve results showed that LAEF had a high efficiency in the diagnosis of NVPAF, with <i>P</i> < 0.001, AUC of 0.843, sensitivity of 0.788, and specificity of 0.867. For the LA strain parameters, the S_R test efficiency was higher, with <i>P</i> < 0.001, AUC of 0.762, sensitivity of 0.713, and specificity of 0.783. There was a strong correlation between S_R and LAEF in patients with no end event and those with end event. The ROC curve revealed that the S_R was better than LAEF in predicting prognosis of patients with AF (AUC = 0.914, <i>P</i> < 0.0001 vs. AUC = 0.876, <i>P</i> < 0.0001). S_R of 10.5 and LAEF of 21 were the cut-off values for endpoint events in NVPAF patients, with sensitivity of 0.909 and 0.727 and specificity of 0.904 and 0.901, respectively.</p><p><strong>Conclusions: </strong>AFILA ultrasound technology comprehensively evaluated the LA size and function in patients with NVPAF. The LAEF and S_R were independently correlate","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"2023 ","pages":"6924570"},"PeriodicalIF":2.1,"publicationDate":"2023-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10681773/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138458071","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Complications of Implantable Cardioverter Defibrillator and Their Potential Risk Factors in Patients with Hypertrophic Cardiomyopathy","authors":"Mohammad Taghi Hedayati Goudarzi, Maryam Moradi, Saeed Abrotan, Mehrdad Saravi, Hoda Shirafkan, Rana Irilouzadian, Hossein Salehi Omran","doi":"10.1155/2023/4552100","DOIUrl":"https://doi.org/10.1155/2023/4552100","url":null,"abstract":"Background. Hypertrophic cardiomyopathy (HCM) has different complications such as cardiac arrhythmia and sudden cardiac death (SCD). Insertion of an implantable cardioverter defibrillator (ICD) is recommended for HCM patients who are at high risk of SCD and malignant arrhythmias, despite having their own potential complications. Hypothesis. We aimed to investigate the prevalence of different complications of ICD insertion and the impact of the potential influential baseline characteristics in a one-year follow-up period. Methods. This was a retrospective study with a total of 71 HCM patients with ICD insertion. We evaluated the prevalence of different complications of ICD implantation and the impact of baseline characteristics on the occurrence of ICD complications using multivariate regression analysis in three 4-month periods. Results. In a one-year follow-up, 13 patients (18.3%) experienced at least one of the complications including pneumothorax, lead failure, ICD infection, inappropriate shocks, perforation, and upper limb deep vein thrombosis (DVT) with no mortality. Inappropriate shocks were reported as the most common (11.3%) complication during this period, with a gradual increase in the second (4.2%) and third (5.6%) follow-up sessions. Among all of the baseline characteristics that were investigated in this study, a positive history of hypertension was the only risk factor with significant impact on the occurrence of complications ( <math xmlns=\"http://www.w3.org/1998/Math/MathML\" id=\"M1\"> <mi>P</mi> </math> = 0.01). Conclusion. We demonstrated the occurrence of complications during a one-year follow-up as 18.3% in HCM patients with ICD insertion. A positive history of hypertension was the only baseline characteristic affecting the occurrence of complications, and inappropriate shocks were the most common complication.","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"68 20","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136281842","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}