Arquivos brasileiros de oftalmologia最新文献

筛选
英文 中文
Modified suture-less flanged intrascleral intraocular lens fixation approach accessible for novice retinal surgeons. 改良无缝合线法兰巩膜内人工晶状体固定入路,适用于视网膜外科新手。
IF 1.2 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-11-21 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2025-0052
Bo-Een Hwang, Woong-Joo Whang, Young-Hoon Park
{"title":"Modified suture-less flanged intrascleral intraocular lens fixation approach accessible for novice retinal surgeons.","authors":"Bo-Een Hwang, Woong-Joo Whang, Young-Hoon Park","doi":"10.5935/0004-2749.2025-0052","DOIUrl":"10.5935/0004-2749.2025-0052","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate whether two simplified mo-difications of flanged intrascleral fixation techniques (Yamane and Canabrava) provide comparable refractive outcomes and complication rates while reducing surgical complexity in tro-car-assisted vitrectomy.</p><p><strong>Methods: </strong>This retrospective observational study included 88 patients who underwent flanged fixation surgery with vitrectomy. In the modified Yamane technique, a single-path sclerotomy with bilateral symmetry was performed instead of an angled sclerotomy. In the modified Canabrava technique, the intraocular lens was inserted first, followed by the creation of a circular polypropylene loop with 2-mm flange spacing. Postoperative refractive parameters, including intraocular lens astigmatism, and complications such as intraocular lens iris capture were analyzed.</p><p><strong>Results: </strong>Of the 88 patients, 70 underwent the modified Yamane technique, and 18 underwent the modified Canabrava technique. No significant differences were observed between the two techniques regarding refractive outcomes or postoperative complications, except for surgical duration, which was significantly shorter (p<0.001) in one technique. Mean intraocular lens astigmatism was -0.675 D for Yamane and -0.666 D for Canabrava.</p><p><strong>Conclusion: </strong>Optimizing needle engagement for symmetry in the Yamane technique and narrowing flange spacing while ensuring a circular polypropylene configuration in the Canabrava technique may reduce surgical complexity and improve postoperative outcomes.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"89 1","pages":"e20250052"},"PeriodicalIF":1.2,"publicationDate":"2025-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145601934","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Real-world evidence of the use of Cloudscaper optotypes versus LEA symbols for virtual or digital visual acuity measurement in children aged 3 to 16 years. 使用Cloudscaper视型与LEA符号进行3至16岁儿童虚拟或数字视力测量的真实证据
IF 1.2 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-11-21 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2025-0049
Cristiana Soares Ronconi, Julia Dutra Rossetto, Luisa Moreira Hopker, Ana Carolina Sarmento Barros Carneiro, Bárbara Stofel Ventorin, Paulo Schor
{"title":"Real-world evidence of the use of Cloudscaper optotypes versus LEA symbols for virtual or digital visual acuity measurement in children aged 3 to 16 years.","authors":"Cristiana Soares Ronconi, Julia Dutra Rossetto, Luisa Moreira Hopker, Ana Carolina Sarmento Barros Carneiro, Bárbara Stofel Ventorin, Paulo Schor","doi":"10.5935/0004-2749.2025-0049","DOIUrl":"10.5935/0004-2749.2025-0049","url":null,"abstract":"<p><strong>Purpose: </strong>This cross-sectional study compared best-corrected visual acuity obtained using Cloudscaper symbols, a novel optotype developed according to ETDRS specifications for children's virtual screening, with that obtained using LEA symbols.</p><p><strong>Methods: </strong>A total of 560 children aged 3-16 yr underwent visual acuity test with both Cloudscaper symbols and LS. The test application was standardized using the EyeSpy algorithm. Additionally, 147 participants were tested with the standard Snellen E paper chart. Paired t tests were performed to assess the clinical significance of logMAR visual acuity differences.</p><p><strong>Results: </strong>The mean logMAR visual acuity with LEA symbols was 0.12 (standard deviation [SD]=0.18; range, -0.10 to 0.80), while with Cloudscaper symbols it was 0.18 (SD=0.19; range, -0.10 to 0.80). The mean difference between Cloudscaper symbols and LEA symbols was 0.099 logMAR (approximately 0.5 optotypes; SD=0.08; range, 0.0-0.14; p<0.0001). Cloudscaper symbols slightly underestimated visual acuity compared to LEA symbols. Visual acuity measured by both methods was highly correlated (Spearman's r=0.74, p<0.0001). The mean visual acuity difference between Cloudscaper symbols and the Snellen E chart was 0.0045 (p=0.805; 95% confidence interval [95% CI]), whereas the difference between LEA symbols and Snellen E was 0.0883 (p<0.001; 95% CI).</p><p><strong>Conclusions: </strong>Cloudscaper symbols provide a reliable tool for visual screening in children. Although they slightly underestimate visual acuity compared to LEA symbols - a finding also reported when comparing ETDRS letters with LEA symbols - Cloudscaper symbols show strong agreement with Snellen E chart measurements. This suggests that Cloudscaper symbols allow precise visual acuity assessment comparable to the gold standard.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"89 1","pages":"e20250049"},"PeriodicalIF":1.2,"publicationDate":"2025-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145602008","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Ongoing reepithelialization after keratopigmentation. 角膜色素沉着后持续的再上皮化。
IF 1.2 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-11-17 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2025-0193
Giovanni Garottii, Nicole Bulgarão Maricondi de Almeida, Newton Kara-Junior
{"title":"Ongoing reepithelialization after keratopigmentation.","authors":"Giovanni Garottii, Nicole Bulgarão Maricondi de Almeida, Newton Kara-Junior","doi":"10.5935/0004-2749.2025-0193","DOIUrl":"10.5935/0004-2749.2025-0193","url":null,"abstract":"","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 6","pages":"e20250193"},"PeriodicalIF":1.2,"publicationDate":"2025-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12818040/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145556148","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Should each university department have only one postgraduate program? 每个大学系里应该只有一个研究生项目吗?
IF 1.2 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-11-17 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2025-0019
Newton Kara-Junior, Marcony R Santhiago, Luiz Ubirajara Sennes, Mário Luiz Ribeiro-Monteiro
{"title":"Should each university department have only one postgraduate program?","authors":"Newton Kara-Junior, Marcony R Santhiago, Luiz Ubirajara Sennes, Mário Luiz Ribeiro-Monteiro","doi":"10.5935/0004-2749.2025-0019","DOIUrl":"10.5935/0004-2749.2025-0019","url":null,"abstract":"","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 6","pages":"e20250019"},"PeriodicalIF":1.2,"publicationDate":"2025-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12818041/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145556179","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Association between axial length and perfluoropropane gas duration after pars plana vitrectomy with fixed-volume pure gas injection. 固定体积纯气体注入平面体玻璃体切除术后轴长与全氟丙烷气体持续时间的关系。
IF 1.2 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-11-17 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2025-0238
Rodrigo Pessoa Cavalcanti Lira, Ana Paula Teles Silveira, Gabriel Rocha Lira, Maria Isabel Lynch Gaete
{"title":"Association between axial length and perfluoropropane gas duration after pars plana vitrectomy with fixed-volume pure gas injection.","authors":"Rodrigo Pessoa Cavalcanti Lira, Ana Paula Teles Silveira, Gabriel Rocha Lira, Maria Isabel Lynch Gaete","doi":"10.5935/0004-2749.2025-0238","DOIUrl":"10.5935/0004-2749.2025-0238","url":null,"abstract":"","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 6","pages":"e20250238"},"PeriodicalIF":1.2,"publicationDate":"2025-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12818039/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145556182","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Diagnostic accuracy of a deep learning model for pterygium detection in Barcelos, Brazilian Amazon. 巴西亚马逊地区巴塞罗斯地区翼状胬肉检测深度学习模型的诊断准确性。
IF 1 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-10-24 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2025-0053
Diego Casagrande, Mauro Gobira, Arthur G Fernandes, Marcos Jacob Cohen, Paula Marques Marinho, Kevin Waquim Pessoa Carvalho, Ariane Luttecke-Anders, Beatriz Araujo Stauber, Nívea Nunes Ferraz, Jacob Moysés Cohen, Adriana Berezovsky, Solange Rios Salomão, Rubens Belfort
{"title":"Diagnostic accuracy of a deep learning model for pterygium detection in Barcelos, Brazilian Amazon.","authors":"Diego Casagrande, Mauro Gobira, Arthur G Fernandes, Marcos Jacob Cohen, Paula Marques Marinho, Kevin Waquim Pessoa Carvalho, Ariane Luttecke-Anders, Beatriz Araujo Stauber, Nívea Nunes Ferraz, Jacob Moysés Cohen, Adriana Berezovsky, Solange Rios Salomão, Rubens Belfort","doi":"10.5935/0004-2749.2025-0053","DOIUrl":"10.5935/0004-2749.2025-0053","url":null,"abstract":"<p><strong>Purpose: </strong>This pilot study evaluated the diagnostic accuracy of a deep learning model for detecting pterygium in anterior segment photographs taken using smartphones in the Brazilian Amazon. The model's performance was benchmarked against assessments made by experienced ophthalmologists, considered the clinical gold standard.</p><p><strong>Methods: </strong>In this cross-sectional study, 38 participants (76 eyes) from Barcelos, Brazil, were enrolled. Trained nonmedical health workers captured high-resolution anterior segment images using smartphones. These images were analyzed using a deep learning model based on the MobileNet-V2 convolutional neural network. Diagnostic metrics-including sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve-were calculated and compared with the ophthalmologists' evaluations.</p><p><strong>Results: </strong>The deep learning model achieved a sensitivity of 91.43%, specificity of 90.24%, positive predictive value of 88.46%, negative predictive value of 92.79%, and an area under the curve of 0.91. Logistic regression revealed no statistically significant association between pterygium and demographic variables such as age or gender.</p><p><strong>Conclusions: </strong>The deep learning model demonstrated high diagnostic performance in identifying pterygium in a remote Amazonian population. These preliminary findings support the potential use of artificial intelligence-based tools to facilitate early detection and screening in underserved regions, thereby enhancing access to ophthalmic care.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 6","pages":"e20250053"},"PeriodicalIF":1.0,"publicationDate":"2025-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12997579/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145421053","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Perioperative subconjunctival steroid injection in dropless cataract surgery: a systematic review and meta-analysis. 无滴白内障手术围手术期结膜下类固醇注射:系统回顾和荟萃分析。
IF 1 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-10-10 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2024-0394
Laura Goldfarb Cyrino, Dillan Amaral, Alexandre Yamada Fujimura Júnior, Bela J Parekh, Marcela Marino de Azeredo Bastos, Giovana de Souza Gaio, Maria Antônia Torres Arteche, Amanda Souza do Nascimento, Vitor Expedito Alves Ribeiro, Jaime Guedes, Marianna Almeida Hollaender
{"title":"Perioperative subconjunctival steroid injection in dropless cataract surgery: a systematic review and meta-analysis.","authors":"Laura Goldfarb Cyrino, Dillan Amaral, Alexandre Yamada Fujimura Júnior, Bela J Parekh, Marcela Marino de Azeredo Bastos, Giovana de Souza Gaio, Maria Antônia Torres Arteche, Amanda Souza do Nascimento, Vitor Expedito Alves Ribeiro, Jaime Guedes, Marianna Almeida Hollaender","doi":"10.5935/0004-2749.2024-0394","DOIUrl":"10.5935/0004-2749.2024-0394","url":null,"abstract":"<p><p>The advantages and disadvantages of using perioperative subconjunctival steroid injections in dropless cataract surgery continue to be debated. A systematic review of PubMed, EMBASE, and the Cochrane Central database identified five studies-two randomized controlled trials and three non-randomized studies-encompassing 70,751 eyes. Among these, 12,319 eyes (17.4%) received subconjunctival steroid injections, while 58,432 eyes (82.6%) were managed with topical steroids. The Cochrane Collaboration's RoB 2 tool was applied for bias assessments in randomized controlled trials, and heterogeneity was assessed using the I² statistics. No statistically significant differences were found between the two groups regarding macular edema (p=0.249), visual acuity (p=0.73), or laser flare count (p=0.45). Both subconjunctival injections and topical steroids demonstrated comparable efficacy and safety in controlling postoperative inflammation after cataract surgery. Additional research is warranted to validate these conclusions.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 6","pages":"e20240394"},"PeriodicalIF":1.0,"publicationDate":"2025-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12997625/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145298203","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Longitudinal evaluation of corneal stability and tear film changes in first-time soft-contact lens wearers. 首次配戴软性隐形眼镜者角膜稳定性及泪膜变化的纵向评价。
IF 1 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-10-10 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2025-0118
Neşe Arslan, Şule Barman Kakil, Bahar Aydoğdu, Hande Hüsniye Telek
{"title":"Longitudinal evaluation of corneal stability and tear film changes in first-time soft-contact lens wearers.","authors":"Neşe Arslan, Şule Barman Kakil, Bahar Aydoğdu, Hande Hüsniye Telek","doi":"10.5935/0004-2749.2025-0118","DOIUrl":"10.5935/0004-2749.2025-0118","url":null,"abstract":"<p><strong>Purpose: </strong>Using advanced imaging techniques, this study aimed to evaluate corneal stability, epithelial remodeling, and tear film changes over a one-year period in first-time soft-contact lens wearers.</p><p><strong>Methods: </strong>A retrospective study was conducted on 100 eyes of 50 first-time daily soft-contact lens users aged 21-65 years with no prior rigid gas-permeable lens wear. The Sirius Scheimpflug imaging system was used to assess corneal topography, epithelial thickness, and non-invasive tear break-up time at baseline, 3, 6, and 12 months. Corneal warpage was evaluated using symmetry indices and Baiocchi Calossi Versaci indices. We performed statistical analysis using repeated-measures analyses of variance with Greenhouse-Geisser correction.</p><p><strong>Results: </strong>The mean baseline central corneal thickness was 537.83 (±7.92) µm, with no significant thinning after one year. The average simulated keratometry values remained stable, indicating no progressive corneal steepening or flattening. There were no significant changes in warpage indices over time, suggesting corneal shape preservation. Higher-order aberrations (coma, trefoil, and spherical aberrations) and non-invasive tear break-up time remained unchanged throughout the study period.</p><p><strong>Conclusions: </strong>Modern silicone hydrogel soft-contact lenses do not induce significant corneal warpage, epithelial remodeling, or optical aberrations over a one-year period. We found that corneal morphology and tear film stability were preserved, supporting the safety of soft-contact lens use. These findings provide clinically relevant insights into the long-term impact of contact lens wear. They may facilitate improved lens fitting strategies and preope rative refractive surgery assessments.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 6","pages":"e20250118"},"PeriodicalIF":1.0,"publicationDate":"2025-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12997644/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145298219","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Impact of screen use on tear breakup time: associations with ophthalmological factors and break frequency in office workers. 屏幕使用对泪液破裂时间的影响:与眼科因素和办公室工作人员泪液破裂频率的关系。
IF 1 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-10-10 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2025-0083
Berire Şeyma Durmuş Ece, İremnur Altındaş
{"title":"Impact of screen use on tear breakup time: associations with ophthalmological factors and break frequency in office workers.","authors":"Berire Şeyma Durmuş Ece, İremnur Altındaş","doi":"10.5935/0004-2749.2025-0083","DOIUrl":"10.5935/0004-2749.2025-0083","url":null,"abstract":"<p><strong>Purpose: </strong>To examine how ophthalmological features, screen exposure duration, and break habits among office employees affect ocular surface parameters.</p><p><strong>Methods: </strong>This single-center cross-sectional study involved two assessments on the same day: one before and one after a visual display terminal task. During the initial assessment, information on screen use was gathered, and refractive error, anterior segment examination, tear breakup time, and Schirmer test measurements were conducted. Participants tracked their screen usage and break durations throughout the day. At the end of the workday, tear breakup time and Schirmer I tests were repeated. Baseline and follow-up results were compared, and regression analysis was performed to identify factors linked to tear breakup time reduction.</p><p><strong>Results: </strong>The study enrolled 60 female office employees. Their mean screen time was 269.26 ± 70.21 min, with an average break duration of 151.93 ± 46.24 min. Tear breakup time at the second assessment (6.38 ± 2.70) was significantly lower than at baseline (8.62 ± 2.73) (p<0.001), whereas Schirmer test scores showed no significant change (p>0.05). Tear breakup time reduction was noted in 54 participants (90.0%), with a significant association between tear breakup time decrease percentage and screen exposure (p=0.001, r=0.463). Regression analysis showed that uncorrected or undercorrected refractive error was an independent risk factor for a ≥30% tear breakup time reduction, while taking more frequent short breaks (<15 min) acted as a protective factor.</p><p><strong>Conclusions: </strong>Taking more frequent short breaks (<15 min) and correcting refractive errors help prevent intra-day tear breakup time decline during visual display terminal use. Structuring breaks to support tear film stability is advisable for occupations that require regular visual display terminal tasks.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 6","pages":"e20250083"},"PeriodicalIF":1.0,"publicationDate":"2025-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12997607/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145298110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
24-Month outcomes of gonioscopy-assisted transluminal trabeculotomy for congenital glaucoma. 镜检辅助腔内小梁切开术治疗先天性青光眼的24个月疗效。
IF 1 4区 医学
Arquivos brasileiros de oftalmologia Pub Date : 2025-10-10 eCollection Date: 2025-01-01 DOI: 10.5935/0004-2749.2024-0309
Maria Betânia Calzavara Lemos, Bruno Mendes de Faria, Mariana Botrel Cunha, Frederico de Miranda Cordeiro, Pedro Hélio Estevam Ribeiro Júnior, Ana Luiza Bassoli Scoralick, Fábio Bernardi Daga, Fabio Nishimura Kanadani, Tiago Santos Prata
{"title":"24-Month outcomes of gonioscopy-assisted transluminal trabeculotomy for congenital glaucoma.","authors":"Maria Betânia Calzavara Lemos, Bruno Mendes de Faria, Mariana Botrel Cunha, Frederico de Miranda Cordeiro, Pedro Hélio Estevam Ribeiro Júnior, Ana Luiza Bassoli Scoralick, Fábio Bernardi Daga, Fabio Nishimura Kanadani, Tiago Santos Prata","doi":"10.5935/0004-2749.2024-0309","DOIUrl":"10.5935/0004-2749.2024-0309","url":null,"abstract":"<p><strong>Purpose: </strong>To report the surgical outcomes of patients with primary congenital glaucoma who underwent gonioscopy-assisted transluminal trabeculotomy.</p><p><strong>Methods: </strong>This retrospective, noncomparative, interventional study included consecutive patients with primary congenital glaucoma with uncontrolled intraocular pressure undergoing gonioscopy-assisted transluminal trabeculotomy between January 2017 and January 2020. The included participants were followed up for at least 24 months, and only one surgeon performed all the procedures. The number of glaucoma medications, pre- and postoperative intraocular pressure, treatment extension (in quadrants), surgical complications, and any associated events or interventions were documented.</p><p><strong>Results: </strong>This study included 13 eyes from 10 patients (mean age, 4.5 ± 3.2 years; range, 3 months to 10 years). After a 24-month follow-up, the mean intraocular pressure significantly decreased from 26.1 ± 3.7 to 11.8 ± 2.5 mmHg (p<0.001). The mean number of glaucoma medications was reduced from 3.3 ± 0.5 to 0.85 ± 1.0 (p<0.001). At the end of the follow-up interval, all eyes (13 out of 13) had an intraocular pressure between 7 and 15 mmHg. In 11 of 13 eyes (84.6%), gonioscopy-assisted transluminal trabeculotomy was performed in all quadrants (360º). The most frequent postoperative complication was transitory (self-limited) hyphema (7 out of 13 eyes [53.8%]). No sight-threatening adverse events occurred during the entire follow-up period.</p><p><strong>Conclusions: </strong>The 2-year follow-up results indicated gonioscopy-assisted transluminal trabeculotomy as an efficient and safe option for primary congenital glaucoma treatment with minimal postoperative complications.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 6","pages":"e20240309"},"PeriodicalIF":1.0,"publicationDate":"2025-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13107970/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145298541","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书