Journal of Advanced Prosthodontics最新文献

筛选
英文 中文
Influence of size-anatomy of the maxillary central incisor on the biomechanical performance of post-and-core restoration with different ferrule heights. 上颌中切牙的大小解剖对不同卡环高度的桩核修复生物力学性能的影响
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-04-01 Epub Date: 2024-04-24 DOI: 10.4047/jap.2024.16.2.77
Domingo Santos Pantaleón, João Paulo Mendes Tribst, Franklin García-Godoy
{"title":"Influence of size-anatomy of the maxillary central incisor on the biomechanical performance of post-and-core restoration with different ferrule heights.","authors":"Domingo Santos Pantaleón, João Paulo Mendes Tribst, Franklin García-Godoy","doi":"10.4047/jap.2024.16.2.77","DOIUrl":"https://doi.org/10.4047/jap.2024.16.2.77","url":null,"abstract":"<p><strong>Purpose: </strong>The study aims to investigate the influence of the ferrule effect and types of posts on the stress distribution in three morphological types of the maxillary central incisor.</p><p><strong>Materials and methods: </strong>Nine models were created for 3 maxillary central incisor morphology types: \"Fat\" type - crown 12.5 mm, root 13 mm, and buccolingual cervical diameter 7.5 mm, \"Medium\" type - crown 11 mm, root 14 mm, and buccolingual cervical diameter 6.5 mm, and \"Slim\" type - crown 9.5 mm, root 15 mm, and buccolingual cervical diameter 5.5 mm. Each model received an anatomical castable post-and-core or glass-fiber post with resin composite core and three ferrule heights (nonexistent, 1 mm, and 2 mm). Then, a load of 14 N was applied at the cingulum with a 45° slope to the long axis of the tooth. The Maximum Principal Stress and the Minimum Principal Stress were calculated in the root dentin, crown, and core.</p><p><strong>Results: </strong>Higher tensile and compression stress values were observed in root dentin using the metallic post compared to the fiber post, being higher in the slim type maxillary central incisor than in the medium and fat types. Concerning the three anatomical types of maxillary central incisors, the slim type without ferrule height in mm presented the highest tensile stress in the dentin, for both types of metal and fiber posts.</p><p><strong>Conclusion: </strong>Post system and tooth morphology were able to modify the biomechanical response of restored endodontically-treated incisors, showing the importance of personalized dental treatment for each case.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 2","pages":"77-90"},"PeriodicalIF":2.6,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11058349/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140860158","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The role of internal architecture in producing high-strength 3D printed cobalt-chromium objects. 内部结构在生产高强度 3D 打印钴铬物体中的作用。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-04-01 Epub Date: 2024-04-24 DOI: 10.4047/jap.2024.16.2.91
Abdullah Jasim Mohammed, Ahmed Asim Al-Ali
{"title":"The role of internal architecture in producing high-strength 3D printed cobalt-chromium objects.","authors":"Abdullah Jasim Mohammed, Ahmed Asim Al-Ali","doi":"10.4047/jap.2024.16.2.91","DOIUrl":"https://doi.org/10.4047/jap.2024.16.2.91","url":null,"abstract":"<p><strong>Purpose: </strong>The objectives of the current study were to estimate the influence of self-reinforced hollow structures with a graded density on the dimensional accuracy, weight, and mechanical properties of Co-Cr objects printed with the direct metal laser sintering (DMLS) technique.</p><p><strong>Materials and methods: </strong>Sixty-five dog-bone samples were manufactured to evaluate the dimensional accuracy of printing, weight, and tensile properties of DMLS printed Co-Cr. They were divided into Group 1 (control) (n = 5), Group 2, 3, and 4 with incorporated hollow structures based on (spherical, elliptical, and diamond) shapes; they were subdivided into subgroups (n = 5) according to the volumetric reduction (10%, 15%, 20% and 25%). Radiographic imaging and microscopic analysis of the fractographs were conducted to validate the created geometries; the dimensional accuracy, weight, yield tensile strength, and modulus of elasticity were calculated. The data were estimated by one-way ANOVA and Duncan's tests at <i>P</i> < .05.</p><p><strong>Results: </strong>The accuracy test showed an insignificant difference in the x, y, z directions in all printed groups. The weight was significantly reduced proportionally to the reduced volume fraction. The yield strength and elastic modulus of the control group and Group 2 at 10% volume reduction were comparable and significantly higher than the other subgroups.</p><p><strong>Conclusion: </strong>The printing accuracy was not affected by the presence or type of the hollow geometry. The weight of Group 2 at 10% reduction was significantly lower than that of the control group. The yield strength and elastic modulus of the Group 2 at a 10% reduction showed means equivalent to the compact objects and were significantly higher than other subgroups.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 2","pages":"91-104"},"PeriodicalIF":2.6,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11058351/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140872874","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of universal adhesive pretreatments on the bond strength durability of conventional and adhesive resin cements to zirconia ceramic. 通用粘合剂预处理对氧化锆陶瓷传统粘合剂和粘合剂树脂水门汀粘合强度耐久性的影响。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-04-01 Epub Date: 2024-04-24 DOI: 10.4047/jap.2024.16.2.105
Tae-Yub Kwon, Seung-Hee Han, Du-Hyeong Lee, Jin-Woo Park, Young Kyung Kim
{"title":"Effect of universal adhesive pretreatments on the bond strength durability of conventional and adhesive resin cements to zirconia ceramic.","authors":"Tae-Yub Kwon, Seung-Hee Han, Du-Hyeong Lee, Jin-Woo Park, Young Kyung Kim","doi":"10.4047/jap.2024.16.2.105","DOIUrl":"https://doi.org/10.4047/jap.2024.16.2.105","url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the effect of pretreatment of three different universal adhesives (Single Bond Universal [SBU], All-Bond Universal [ABU], and Prime&Bond universal [PBU]) on the bonding durability of an adhesive (Panavia F 2.0, PF) and a conventional (Duo-Link, DL) resin cements to air-abraded zirconia.</p><p><strong>Materials and methods: </strong>Rectangular-shaped zirconia specimens were prepared. The chemical composition and surface energy parameters of the materials were studied by Fourier transform infrared spectroscopy and contact angle measurement, respectively. To evaluate resin bonding to the zirconia, all the bonding specimens were immersed in water for 24 h and the specimens to be aged were additionally thermocycled 10000 times before the shear bond strength (SBS) test.</p><p><strong>Results: </strong>The materials showed different surface energy parameters, including the degree of hydrophilicity/hydrophobicity. While the DL/CON (no pretreatment) showed the lowest SBS and a significant decrease in the value after thermocycling (<i>P</i> < .001), the PF/CON obtained a higher SBS value than the DL/CON (<i>P</i> < .001) and no decrease even after thermocycling (<i>P</i> = .839). When the universal adhesives were used with DL, their SBS values were higher than the CON (<i>P</i> < .05), but the trend was adhesive-specific. In conjunction with PF, the PF/SBU produced the highest SBS followed by the PF/ABU (<i>P</i> = .002), showing no significant decrease after thermocycling (<i>P</i> > .05). The initial SBS of the PF/PBU was similar to the PF/CON (<i>P</i> = .999), but the value decreased after thermocycling (<i>P</i> < .001).</p><p><strong>Conclusion: </strong>The universal adhesive pretreatment did not necessarily show a synergistic effect on the bonding performance of an adhesive resin cement, whereas the pretreatment was beneficial to bond strength and durability of a conventional resin cement.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 2","pages":"105-114"},"PeriodicalIF":2.6,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11058350/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140873336","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling. 传统制造、三维打印和 CAD-CAM 研磨的临时义齿材料在热循环后的断裂强度、表面硬度和色斑比较。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-04-01 Epub Date: 2024-04-24 DOI: 10.4047/jap.2024.16.2.115
Mesut Yıldırım, Filiz Aykent, Mahmut Sertaç Özdoğan
{"title":"Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling.","authors":"Mesut Yıldırım, Filiz Aykent, Mahmut Sertaç Özdoğan","doi":"10.4047/jap.2024.16.2.115","DOIUrl":"https://doi.org/10.4047/jap.2024.16.2.115","url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this <i>in vitro</i> study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials.</p><p><strong>Materials and methods: </strong>A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE<sub>00</sub>]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (<i>P</i> < .05).</p><p><strong>Results: </strong>The highest crown fracture resistance values were determined for the 3D printed composite resin (<i>P</i> < .05), and the lowest were observed in the bis-acryl composite resin (<i>P</i> < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (<i>P</i> < .05) and the highest ΔE<sub>00</sub> value were observed in PMMA resin for all materials (<i>P</i> < .05).</p><p><strong>Conclusion: </strong>3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 2","pages":"115-125"},"PeriodicalIF":2.6,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11058348/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140868850","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of sintering programs and surface treatments on monolithic zirconia. 烧结程序和表面处理对整体氧化锆的影响
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-02-01 Epub Date: 2024-02-23 DOI: 10.4047/jap.2024.16.1.25
Seren Nur Dokuzlu, Meryem Gülce Subaşı
{"title":"Effect of sintering programs and surface treatments on monolithic zirconia.","authors":"Seren Nur Dokuzlu, Meryem Gülce Subaşı","doi":"10.4047/jap.2024.16.1.25","DOIUrl":"10.4047/jap.2024.16.1.25","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the effect of sintering programs and surface treatments on surface properties, phase transformation and flexural strength of monolithic zirconia.</p><p><strong>Materials and methods: </strong>Zirconia specimens were sintered using three distinct sintering programs [classic (C), speed (S), and superspeed (SS)] (n = 56, each). One sample from each group underwent scanning electron microscopy (SEM) and grain size analysis following sintering. Remaining samples were divided into five subgroups (n = 11) based on the surface treatments: control (CL), polish (P), glaze (G), grind + polish (GP), and grind + glaze (GG). One sample from each subgroup underwent SEM analysis. Remaining samples were thermally aged. Monoclinic phase volume, surface roughness, and three-point flexural strength were measured. Monoclinic phase volume and surface roughness were analyzed by Kruskal-Wallis and Dunn tests. Flexural strength was analyzed by two-way ANOVA and Weibull analysis. The relationships among the groups were analyzed using Spearman's correlation analysis.</p><p><strong>Results: </strong>Sintering program, surface treatment, and sintering × surface treatment (<i>P</i> ≤ .010) affected the monoclinic phase volume, whereas the type of surface treatment and sintering × surface treatment affected the surface roughness (<i>P</i> < .001). Type of sintering program or surface treatment did not affect the flexural strength. Weibull analysis revealed no significant differences between the m and σ<sub>o</sub> values. Monoclinic phase volume was positively correlated with surface roughness in the SGG and SSP groups.</p><p><strong>Conclusion: </strong>After sintering monolithic zirconia in each of the three sintering programs, each of the surface treatments can be used. However, for surface quality and aging resistance, G or GG can be recommended as a surface finishing method.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 1","pages":"25-37"},"PeriodicalIF":2.6,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10917628/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140061209","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study. 改良手术方案对在部分无牙颌后嵴及远端扩展的全引导种植手术中种植牙位置准确性的影响:牙形模型研究。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-02-01 Epub Date: 2024-02-23 DOI: 10.4047/jap.2024.16.1.1
Young Woo Song, Seung Ha Yoo, Ui-Won Jung
{"title":"Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study.","authors":"Young Woo Song, Seung Ha Yoo, Ui-Won Jung","doi":"10.4047/jap.2024.16.1.1","DOIUrl":"10.4047/jap.2024.16.1.1","url":null,"abstract":"<p><strong>Purpose: </strong>The present experiment aimed to evaluate the placement accuracy of fully guided implant surgery using a mucosa-supported surgical guide when the protocol of osteotomy and installation was modified (MP) compared to when the protocol was sequentially and conventionally carried out (CP).</p><p><strong>Materials and methods: </strong>For 24 mandibular dentiform models, 12 dentists (6 experts and 6 beginners) performed fully guided implant placements two times at the right first and second molar sites using a mucosa-supported surgical guide, once by the CP (CP group) and at the other time by the MP (MP group). The presurgical and postsurgical stereolithographic images were superimposed, and the deviations between the virtually planned and actually placed implant positions and the procedure time were compared statistically (<i>P</i> < .05).</p><p><strong>Results: </strong>The accuracies were similar in the CP and MP groups. In the CP group, the mean platform and apex deviations at the second molar site for the beginners were +0.75 mm and +1.14 mm, respectively, which were significantly larger than those for the experts (<i>P</i> < .05). In the MP group, only the mean vertical deviation at the second molar site for the beginners (+0.53 mm) was significantly larger than that for the experts (<i>P</i> < .05). The procedure time was significantly longer for the MP group (+94.0 sec) than for the CP group (<i>P</i> < .05).</p><p><strong>Conclusion: </strong>In fully guided implant surgery using a mucosa-supported guide, the MP may improve the placement accuracy when compared to the CP, especially at sites farther from the most-posterior natural tooth.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 1","pages":"1-11"},"PeriodicalIF":2.6,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10917626/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140061210","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Erratum - Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study. 勘误 - 采用激光处理表面的即刻植入和早期植入种植体的临床效果:一项为期 3 年的回顾性研究。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-02-01 Epub Date: 2024-02-23 DOI: 10.4047/jap.2024.16.1.66
{"title":"Erratum - Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study.","authors":"","doi":"10.4047/jap.2024.16.1.66","DOIUrl":"https://doi.org/10.4047/jap.2024.16.1.66","url":null,"abstract":"<p><p>[This corrects the article on p. 163 in vol. 10, PMID: 29713438.].</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 1","pages":"66"},"PeriodicalIF":2.6,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10917627/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140061211","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The metameric effect of monolithic zirconias with varying yttrium ratios. 不同钇比的整体氧化锆的偏聚效应。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-02-01 Epub Date: 2024-02-23 DOI: 10.4047/jap.2024.16.1.48
Mehmet Ejder Güven, Özlem Kara
{"title":"The metameric effect of monolithic zirconias with varying yttrium ratios.","authors":"Mehmet Ejder Güven, Özlem Kara","doi":"10.4047/jap.2024.16.1.48","DOIUrl":"10.4047/jap.2024.16.1.48","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the metameric disparities among monolithic zirconia materials with differing yttrium compositions across various lighting conditions.</p><p><strong>Materials and methods: </strong>Thirty-six square-shaped zirconia samples measuring 10 × 10 × 0.5 mm were prepared from monolithic zirconia materials with three different yttrium contents. A 0.2 mm thick layer of polymerized dual-polymerizable self-adhesive resin cement was created using a silicone mold with the same dimensions as the prepared zirconia specimens. To evaluate metamerism, color measurements were conducted using a spectrophotometer device on a neutral gray background in a color measurement cabinet that offers four different illumination environments. All samples underwent aging by subjecting them to 10000 thermal cycles using a thermal cycle tester. Following thermal aging, color measurements were taken once more, and the data were recorded using the CIE L<sup>*</sup>, a<sup>*</sup>, b<sup>*</sup> color system. Two-way ANOVA and Post-hoc Bonferroni tests were employed to analyze the data.</p><p><strong>Results: </strong>It was observed that there was no statistical difference among the color measurements made in different illumination environments of the monolithic zirconia ceramics used to evaluate metamerism (<i>P</i> > .05). This observation remained consistent both before and after thermal aging. After thermal aging, the color of monolithic zirconia materials exhibited a tendency towards red and yellow hues, accompanied by a decrease in brightness levels.</p><p><strong>Conclusion: </strong>It can be stated that different illumination conditions did not affect the metamerism of monolithic zirconia materials, but there was a color change in monolithic zirconia materials after a thermal aging period equivalent to one year.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 1","pages":"48-56"},"PeriodicalIF":2.6,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10917625/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140061212","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions. 数码印模与传统印模在陶瓷嵌体边缘贴合度方面的临床比较。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-02-01 Epub Date: 2024-02-23 DOI: 10.4047/jap.2024.16.1.57
Franklin Guillermo Vargas-Corral, Américo Ernesto Vargas-Corral, Miguel Angel Rodríguez-Valverde, Manuel Bravo, Juan Ignacio Rosales-Leal
{"title":"Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions.","authors":"Franklin Guillermo Vargas-Corral, Américo Ernesto Vargas-Corral, Miguel Angel Rodríguez-Valverde, Manuel Bravo, Juan Ignacio Rosales-Leal","doi":"10.4047/jap.2024.16.1.57","DOIUrl":"10.4047/jap.2024.16.1.57","url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this stuldy was to compare the clinical marginal fit of CAD-CAM inlays obtained from intraoral digital impression or addition silicone impression techniques.</p><p><strong>Materials and methods: </strong>The study included 31 inlays for prosthodontics purposes of 31 patients: 15 based on intraoral digital impressions (DI group); and 16 based on a conventional impression technique (CI group). Inlays included occlusal and a non-occlusal surface. Inlays were milled in ceramic. The inlay-teeth interface was replicated by placing each inlay in its corresponding uncemented clinical preparation and taking interface impressions with silicone material from occlusal and free surfaces. Interface analysis was made using white light confocal microscopy (WLCM) (scanning area: 694 × 510 µm<sup>2</sup>) from the impression samples. The gap size and the inlay overextension were measured from the microscopy topographies. For analytical purposes (i.e., 95-%-confidence intervals calculations and <i>P</i>-value calculations), the procedure REGRESS in SUDAAN was used to account for clustering (i.e., multiple measurements). For p-value calculation, the log transformation of the dependent variables was used to normalize the distributions.</p><p><strong>Results: </strong>Marginal fit values for occlusal and free surfaces were affected by the type of impression. There were no differences between surfaces (occlusal vs. free). Gap obtained for DI group was 164 ± 84 µm and that for CI group was 209 ± 104 µm, and there were statistical differences between them (<i>p</i> = .041). Mean overextension values were 60 ± 59 µm for DI group and 67 ± 73 µm for CI group, and there were no differences between then (<i>p</i> = .553).</p><p><strong>Conclusion: </strong>Digital impression achieved inlays with higher clinical marginal fit and performed better than the conventional silicone materials.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 1","pages":"57-65"},"PeriodicalIF":2.6,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10917630/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140061207","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of different digital shade selection methodologies in terms of accuracy. 比较不同数字阴影选择方法的准确性。
IF 2.6 3区 医学
Journal of Advanced Prosthodontics Pub Date : 2024-02-01 Epub Date: 2024-02-23 DOI: 10.4047/jap.2024.16.1.38
Nurşen Şahin, Çağrı Ural
{"title":"Comparison of different digital shade selection methodologies in terms of accuracy.","authors":"Nurşen Şahin, Çağrı Ural","doi":"10.4047/jap.2024.16.1.38","DOIUrl":"10.4047/jap.2024.16.1.38","url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to evaluate the accuracy of different shade selection techniques and determine the matching success of crown restorations fabricated using digital shade selection techniques.</p><p><strong>Materials and methods: </strong>Teeth numbers 11 and 21 were prepared on a typodont model. For the #11 tooth, six different crowns were fabricated with randomly selected colors and set as the target crowns. The following four test groups were established: Group C, where the visual shade selection was performed using the Vita 3D Master Shade Guide and the group served as the control; Group Ph, where the shade selection was performed under the guidance of dental photography; Group S, where the shade selection was performed by measuring the target tooth color using a spectrophotometer; and Group I, where the shade selection was performed by scanning the test specimens and target crowns using an intraoral scanner. Based on the test groups, 24 crowns were fabricated using different shade selection techniques. The ΔE values were calculated according to the CIEDE2000 (2:1:1) formula. The collected data were analyzed by means of a one-way analysis of variance.</p><p><strong>Results: </strong>For the four test groups (Groups C, Ph, S, and I), the following mean ΔE values were obtained: 2.74, 3.62, 2.13, and 3.5, respectively. No significant differences were found among the test groups.</p><p><strong>Conclusion: </strong>Although there was no statistically significant difference among the shade selection techniques, Group S had relatively lower ΔE values. Moreover, according to the test results, the spectrophotometer shade selection technique may provide more successful clinical results.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 1","pages":"38-47"},"PeriodicalIF":2.6,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10917631/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140061208","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信