J. Dong, Y. Schwartz, A. Mavrogianni, I. Korolija, D. Mumovic
{"title":"A review of approaches and applications in building stock energy and indoor environment modelling","authors":"J. Dong, Y. Schwartz, A. Mavrogianni, I. Korolija, D. Mumovic","doi":"10.1177/01436244231163084","DOIUrl":"https://doi.org/10.1177/01436244231163084","url":null,"abstract":"Current energy and climate policies are formulated and implemented to mitigate and adapt to climate change. To inform relevant building policies, two bottom-up building stock modelling approach: 1) archetype-based and 2) Building-by-building have been developed. This paper presents the main characteristics and applications of these two approaches and evaluates and compares their ability to support policy making. Because of lower data requirements and computational cost, archetype-based modelling approaches are still the mainstream approach to stock-level energy modelling, life cycle assessment, and indoor environmental quality assessment. Building-by-building approaches can better capture the heterogeneous characteristics of each building and are emerging due to the development of data acquisition and computational techniques. The model uncertainties exist in both models which may affect the reliability of outputs, while stochastic archetype models and timeless digital twin model have the potential to address the issue. System dynamics modelling approach can describe and address the dynamics and complexity of often-conflicting policies and achieve co-benefit of multiple policy objectives. \u0000 Practical applications\u0000 This paper aims to provide comprehensive knowledge on building stock modelling for modellers and policymakers, so they could use a building stock model with an appropriate user interface without having to fully understand the underlying algorithms or complexities.","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47506581","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Fatima Zahra Benaddi, L. Boukhattem, F. Ait Nouh, Paulo Cesar Tabares-Velasco, B. Benhamou
{"title":"Energy-saving potential assessment of a classroom building envelope through sensitivity analysis and multi-objective optimization under different climate types","authors":"Fatima Zahra Benaddi, L. Boukhattem, F. Ait Nouh, Paulo Cesar Tabares-Velasco, B. Benhamou","doi":"10.1177/01436244231161944","DOIUrl":"https://doi.org/10.1177/01436244231161944","url":null,"abstract":"The present work aims to optimize the thermal behavior of a building envelope by combining sensitivity analysis (SA) and multi-objective optimization (MOO). An existing classroom located in Marrakech city was considered a case study building. The building model was analyzed under six Moroccan climate zones. The SA was applied on 16 design variables and performed using the Morris method implemented in the tool Simlab to rank each design variable based on its influence on the objective function (overall energy demand). The SA results showed that the solar absorptance of the internal roof, wall, and ground floor and the ground hollow core slab thickness impacted less the overall energy demand. Therefore, the only remaining variables showing the most relevant effect will be optimized afterward. The optimization phase was conducted by coupling the generic optimization tool GenOpt with TRNSYS. The optimum solution was selected based on the Pareto front approach. The obtained results assessed the effectiveness of the adopted methodological approach in significant minimization of the required thermal loads. Furthermore, the values of each optimum design variables set differ from one climate zone to another; leading to energy demand reduction varying from 30 to 42%, in comparison with the original design building.","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41975455","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Zhao, Ziyi Qu, Han Xing, Liangdong Ma, Xiuming Li
{"title":"Optimal control of critical fresh air volume based on sectional adjustment of fresh air and return air dampers","authors":"T. Zhao, Ziyi Qu, Han Xing, Liangdong Ma, Xiuming Li","doi":"10.1177/01436244231161949","DOIUrl":"https://doi.org/10.1177/01436244231161949","url":null,"abstract":"During the regulation process of VAV systems, the supply air volume changes with the real time load changes, which will cause the fresh air volume to deviate from its set value. Insufficient fresh air results in poor IAQ, whereas an excessive fresh air increases energy consumption. Therefore, an effective method to control the fresh air volume is essential for VAV systems. Based on the differential pressure control theory, two improved control methods—the fresh air section static pressure control method and the critical air volume control method—are proposed herein. Three control methods were compared through experimental study. The results indicate that differential pressure in the first improved method is higher than that in the differential pressure control method, which increases the ease of measurement. However, both these methods have approximately 15% to 25% errors when the supply air volume is small. The critical air volume control method provides more precise control of the fresh air volume, and eliminates deviations at small supply air volumes. Furthermore, the fan power is reduced as well. Investigation has demonstrated that the critical air volume control method is energy-efficient, and can provide new insights into optimized energy-saving control methods for VAV systems. \u0000 Practical application\u0000 This work proposed a fresh air volume control method of VAV system, the critical air volume control method. This method improves the control accuracy and the convenience of differential pressure measurement of VAV system. The reliability of the method was verified on the test rig, and it is similar to the engineering situation. Therefore, this method has practical application value. Also this method reduces the fan energy consumption of VAV system, thereby improving energy efficiency and reducing operating costs.","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43616455","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Golnaz Mohebbi, A. Hasan, Augustine Blay-Armah, Ali Bahadori-Jahromi, A. Mylona, Mark Barthorpe
{"title":"Comparative analysis of the whole life carbon of three construction methods of a UK-based supermarket","authors":"Golnaz Mohebbi, A. Hasan, Augustine Blay-Armah, Ali Bahadori-Jahromi, A. Mylona, Mark Barthorpe","doi":"10.1177/01436244231161070","DOIUrl":"https://doi.org/10.1177/01436244231161070","url":null,"abstract":"The built environment has been a significant contributor to global carbon emissions. It, therefore, has a vital role to play in the reduction efforts of future climate change. While the design of buildings may determine future energy use for cooling, heating, and lighting during the operational stage of the building, this study aims to observe the effect of the building design on the operational as well as the whole-life carbon emissions. Past studies have focused on either the operational carbon or the embodied carbon of a building. Using a cradle-to-grave assessment of a typical UK supermarket, this study explores the relationship between embodied carbon and operational carbon. Additionally, it examines the effects of the variables between three approved construction methods of the same design on the whole life of carbon. These methods are a steel structural frame and cladding panel external wall, steel frame and poroton walls, precast concrete and glulam frame and precast concrete walls. The findings of this research will contribute to mitigation strategies for the environmental impacts of supermarket building construction whilst providing a framework for future assessment of the whole-life carbon of supermarket buildings. \u0000 Practical Application\u0000 Employing the life cycle assessment methodology, this paper examines the potential of minimising both embodied and operational carbon by observing the whole life carbon. Highlighting the influence of the GHG emission contributing factors in each stage on each other. Additionally, the recommended methodology for the supermarket building types of this case study, could be adapted for other types of buildings. The findings could also augment carbon emission research and guide the development of supermarket buildings to low carbon intensive. Furthermore, collaboration with the industry in carrying out this research aids in adopting the findings as practical and theoretical guides for engineers and designers in reducing the building sector’s harmful environmental impact.","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49090821","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Liora Malki-Epshtein, Filipa Adzic, Ben M Roberts, Elizabeth Abigail Hathway, Christopher Iddon, Murat Mustafa, Malcolm Cook
{"title":"Measurement and rapid assessment of indoor air quality at mass gathering events to assess ventilation performance and reduce aerosol transmission of SARS-CoV-2.","authors":"Liora Malki-Epshtein, Filipa Adzic, Ben M Roberts, Elizabeth Abigail Hathway, Christopher Iddon, Murat Mustafa, Malcolm Cook","doi":"10.1177/01436244221137995","DOIUrl":"10.1177/01436244221137995","url":null,"abstract":"<p><p>To assess risk factors for COVID-19 transmission and address the closure of mass gathering events since March 2020, the UK Government ran the Events Research Programme (ERP), following which it reopened live events in sports, music, and culture in July 2021. We report the rapid post-occupancy evaluation of Indoor Air Quality (IAQ) and associated long-range airborne transmission risk conducted in the Environmental Study of the ERP. Ten large venues around the UK were monitored with CO<sub>2</sub> sensors at a high spatial and temporal resolution during 90 events. An IAQ Index based on CO<sub>2</sub> concentration was developed, and all monitored spaces were classified in bands from A to G based on their average and maximum CO<sub>2</sub> concentrations from all events. High resolution monitoring and the IAQ Index depicted the overall state of ventilation at live events, and allowed identification of issues with ventilation effectiveness and distribution, and of spaces with poor ventilation and the settings in which long-range airborne transmission risk may be increased. In numerous settings, CO<sub>2</sub> concentrations were found to follow patterns relating to event management and specific occupancy of spaces around the venues. Good ventilation was observed in 90% of spaces monitored for given occupancies. <b><i>Practical applications:</i></b> High-resolution monitoring of indoor CO<sub>2</sub> concentrations is necessary to detect the spatial variation of indoor air quality (IAQ) in large mass gathering event venues. The paper summarises COVID-19 ventilation guidance for buildings and defines a methodology for measurement and rapid assessment of IAQ during occupancy at live events that can be implemented by venue managers. Comparisons of the CO<sub>2</sub> concentrations measured during the events identified the spaces at high risk of long-range transmission of airborne pathogens. Building operators should be mindful of the ventilation strategies used relative to the total occupancy in different spaces and the occupant's activities.</p>","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9760526/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42540271","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Demand response with heat pumps: Practical implementation of three different control options.","authors":"Jenny Crawley, Adria Martin-Vilaseca, Jez Wingfield, Zachary Gill, Michelle Shipworth, Clifford Elwell","doi":"10.1177/01436244221145871","DOIUrl":"https://doi.org/10.1177/01436244221145871","url":null,"abstract":"<p><p>The electrification of heating and transport and decarbonisation of supply creates a need for demand side flexibility to balance the grid. Heat pumps are expected to form a major part of heat delivery, and many modelling studies have investigated the technical potential of heat pump demand response. However, little empirical work has been reported on the practical implementation of such demand response in occupied homes. This paper presents a cross-case comparison of three early adopters of heat pump demand response in the UK. The aim was to reduce heat pump electricity consumption during the same peak period, but each employed a different control strategy: lowered air temperature setpoints, lowered flow temperature and blocked heat pump compressor. A 56-90% electricity reduction during the peak period was observed; the success of the demand response depended on how the control strategy affected the heat pump and the rest of the heating system. However, no one stakeholder is responsible for all these system components. The fabric, heating distribution and control system and heat pumps installed are highly heterogeneous across the stock, highlighting that flexibility mechanisms must be developed that can be tailored to or work across their range.</p><p><strong>Practical application: </strong>Three case studies of different heat pump demand response control strategies in real homes are presented. All three households reduced their electricity consumption during a peak period but delivered unintended consequences where the heat pump's logic did not correspond to the demand response requirements. This study highlights that the implementation of heat pump demand response to support electricity system operation requires a clear definition of electricity system need as well as practical demand response mechanisms to be integrated into heating system design.</p>","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9976642/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10849197","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Building services engineering research and technology","authors":"","doi":"10.1177/01436244231158897","DOIUrl":"https://doi.org/10.1177/01436244231158897","url":null,"abstract":"","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46658347","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yongming Zhang, Yicheng Zhao, Zhe Yan, Shuangchang Feng, Jie Chen
{"title":"An image recognition measurement approach and uncertainty for overspeed governors employed in elevator safety","authors":"Yongming Zhang, Yicheng Zhao, Zhe Yan, Shuangchang Feng, Jie Chen","doi":"10.1177/01436244231159022","DOIUrl":"https://doi.org/10.1177/01436244231159022","url":null,"abstract":"Elevator safety is closely related to public safety. Overspeed governor is a crucial part of the elevator safety system. Its inspection and calibration involve the measurement of tripping velocity. The frequently-used contact-type measurement method has risks. This paper proposes a non-contact image-recognizing measurement method by the camera, which includes the processes of rotor centre recognition, feature points matching, and tripping switches recognition. The velocity curve can be obtained by feature points displacement based on the rotor centre. Tripping switches recognition can determine the electrical and mechanical tripping velocities in the speed curve. The experimental results demonstrate that the proposed method has no significant difference from the common contact-type measurement method, while it significantly eliminates the risks of physical damage and improves measurement safety. Moreover, this paper proposes the deduction and calculation of measurement uncertainty decided by camera performance. Due to the enhancement of measuring safety, the proposed method will have further application in the field of elevator inspection. Practical application: The research on tripping velocity measurement for overspeed governor in this paper is principally based on image recognition with the help of a camera. The experiment result indicates that the proposed method is capable of completing the speed measurement for the overspeed governor without contact. The proposed method significantly mitigates the risks of physical damage and improves measurement safety rather than the contact-type measurement method. The proposed non-contact image-recognizing method can substitute for the existing contact-type method and contributes to the inspection, maintenance, and management of elevators, which will have further application prospects.","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49013777","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Validation of computational fluid dynamics simulations for determining pressure loss coefficients of ventilation components","authors":"K. Tawackolian, M. Kriegel","doi":"10.1177/01436244231159537","DOIUrl":"https://doi.org/10.1177/01436244231159537","url":null,"abstract":"Ventilation systems include a variety of components for which necessary pressure loss data is often unavailable. Computational fluid dynamics simulations could substitute for expensive measurements, but validation simulations with suitable data are crucial to assess model uncertainties. Existing CFD validation studies either did not focus specifically on pressure losses, only covered few components, or did not include recent developments in turbulence modelling. In the present work, 33 bends, 4 gates and 2 tees were simulated using a consistent approach. Computational fluid dynamics simulations were validated with published data: rectangular high-edge and wide-edge bends from the experimental dataset of Sprenger, gates and diverging tees from the SMACMA guide. The considered flows cover important basic flow phenomena: deflection, splitting and flow separation. The 39 components were simulated with three turbulence models at 14 Reynolds numbers. The simulations predicted pressure loss coefficients accurately for various components. Cases with strong flow separation regions were most challenging. The model prediction uncertainty was assessed by carrying out simulations with three selected turbulence models. As in the experimental data from Sprenger, the simulations showed a distinct dependence of pressure loss coefficients on the Reynolds number for bends. In contrast, for abrupt deflections and flow separation at sharp edges, the Reynolds number dependency was minor. \u0000 Practical Application\u0000 Technical pressure loss data of ductwork components is needed for the dimensioning, optimisation, and energy assessment of ventilation systems. The present validation study assesses the present state of the art of CFD simulations to determine pressure loss coefficients and the resulting prediction uncertainties.","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45237628","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Bahareh Salehi, D. Andrews, I. Chaer, A. Gillich, Elizabeth J. Newton
{"title":"Assessing the performance gap of two dynamic thermal modelling software tools when comparing with real-time data in relation to thermal loss","authors":"Bahareh Salehi, D. Andrews, I. Chaer, A. Gillich, Elizabeth J. Newton","doi":"10.1177/01436244231153839","DOIUrl":"https://doi.org/10.1177/01436244231153839","url":null,"abstract":"Managing thermal loss is a key topic that needs further investigation as it has a direct link to reducing the energy load in buildings. One of these thermal loss management methods can be the use of shading devices. Dynamic thermal models normally used at the early stages of the building design can play an important role in the decision-making process regarding the use of shading devices. This paper presents the results of a real-world study assessing the potential of using a sealed cellular blind as a passive energy conservation method, where the real-world results are compared with the simulated results generated with environmental design solutions limited thermal analysis software (EDSL Tas) and integrated environmental solutions virtual environment (IES VE). During the real-world study, a positive impact of having blinds was seen whereby the window surface temperature increased and office heating energy consumption was lowered. Both software tools were able to predict a similar trend of results for the window surface temperature in with and without blind scenarios whereas for energy consumption although in the presence of a blind a consistent correlation is seen between measured and calculated values but not without a blind. This can be attributed to the inability of the software tools in demonstrating the effect of infiltration in the absence of a blind or shading device i.e., a clear window scenario. \u0000 Practical Application\u0000 The performance gap analysis regarding thermal loss between dynamic thermal models and real-world settings within buildings can enhance the predictability of the building energy software tools used by designers. Early design inputs within buildings can prevent costly building re-work to improve the building’s energy performance. This can also improve the understanding within the building industry of the importance of reducing thermal loss through the use of shading devices and ensuring the software tools used to model these devices are as close to real-world settings as possible.","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":null,"pages":null},"PeriodicalIF":1.7,"publicationDate":"2023-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44392658","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}