Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems最新文献

筛选
英文 中文
Parametric study of 3D printed microneedle (MN) holders for interstitial fluid (ISF) extraction. 3D打印间质液提取微针支架的参数化研究。
IF 1.6 4区 工程技术
Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems Pub Date : 2020-01-01 Epub Date: 2020-02-01 DOI: 10.1007/s00542-020-04758-0
Robert M Taylor, Dilendra Maharjan, Fernando Moreu, Justin T Baca
{"title":"Parametric study of 3D printed microneedle (MN) holders for interstitial fluid (ISF) extraction.","authors":"Robert M Taylor, Dilendra Maharjan, Fernando Moreu, Justin T Baca","doi":"10.1007/s00542-020-04758-0","DOIUrl":"10.1007/s00542-020-04758-0","url":null,"abstract":"<p><p>The need for novel, minimally invasive diagnostic, prognostic, and therapeutic biomedical devices has garnered increased interest in recent years. Microneedle (MN) technology has stood out as a promising new method for drug delivery, as well as extraction of interstitial fluid (ISF). ISF comprises a large portion of the extracellular fluid in living organisms yet remains inadequately characterized for clinical applications. Current MN research has focused on the fabrication of needles with different materials like silicone, carbon, and metals. However, little effort has been put forth into improving MN holders and patches that can be used with low cost MNs, which could effectively change how MNs are attached to the human body. Here, we describe different 3D-printed MN holders, printed using an MJP Pro 2500 3D printer, and compare the ISF extraction efficiencies in CD Hairless rats. We varied design parameters that may affect the skin-holder interface, such as throat thickness, tip curvature, and throat diameter. MN arrays, with insertion depths of 1500 μm, had extraction efficiencies of 0.44 ± 0.35, 0.85 ± 0.64, 0.32 ± 0.21, or 0.44 ± 0.46 µl/min when designed with flat, concave, convex, or bevel profile geometries, respectively. Our results suggest ISF extraction is influenced by MN holder design parameters and that a concave tip design is optimal for extracting ISF from animals. The future direction of this research aims to enable a paradigm in MN design that maximizes its efficiency and engineering performance in terms of volume, pressure, and wearability, thereby automatizing usage and reducing patient intervention to ultimately benefit remote telemedicine.</p>","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"26 6","pages":"2067-2073"},"PeriodicalIF":1.6,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7238769/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9091841","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
High Density Interconnect Microstrip Patch Antenna for 5G Base Stations with Integrated Filtering Performance 集成滤波性能的5G基站高密度互连微带贴片天线
IF 2.1 4区 工程技术
M. Salucci, C. Castlunger, D. Marcantonio, G. Oliveri, F. Robol, P. Rosatti, L. Tosato, F. Zardi, A. Massa
{"title":"High Density Interconnect Microstrip Patch Antenna for 5G Base Stations with Integrated Filtering Performance","authors":"M. Salucci, C. Castlunger, D. Marcantonio, G. Oliveri, F. Robol, P. Rosatti, L. Tosato, F. Zardi, A. Massa","doi":"10.3390/TECHNOLOGIES6020045","DOIUrl":"https://doi.org/10.3390/TECHNOLOGIES6020045","url":null,"abstract":"The elementary radiator of a planar array for next generation millimeter-wave (mm-wave) 5G base stations is described. The antenna is designed for high density interconnect (HDI) manufacturing for yielding a compact, densely-interconnected, and highly-integrable stacked structure. The layout of the single element is determined by directly optimizing key radiation features of the whole planar arrangement according to specific application-driven requirements. In addition, thanks to the exploitation of a spline-shaped modelling of the radiator, suitable performance in terms of impedance matching, realized gain, half-power beamwidth (HPBW), polarization purity, and inter-element isolation are achieved within the 28-GHz pass-band. Moreover, integrated out-of-band filtering capabilities are obtained in selected and wide non-contiguous stop-bands without additional circuitry","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"14 1","pages":"45"},"PeriodicalIF":2.1,"publicationDate":"2018-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87848823","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Scale factor model analysis of MEMS gyroscopes MEMS陀螺仪的比例因子模型分析
IF 2.1 4区 工程技术
TangQijian, WangXiangjun, YangQingping
{"title":"Scale factor model analysis of MEMS gyroscopes","authors":"TangQijian, WangXiangjun, YangQingping","doi":"10.5555/3086312.3086386","DOIUrl":"https://doi.org/10.5555/3086312.3086386","url":null,"abstract":"Scale factor nonlinearity is one of the main errors of MEMS gyroscopes. The paper firstly analyzes the operating principle of MEMS gyroscopes, and presents the commonly used model in calibration pr...","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"1 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74249559","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An optimised silicon piezoresistive microcantilever sensor for surface stress studies. 一种用于表面应力研究的优化硅压阻微悬臂传感器。
IF 2.1 4区 工程技术
Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems Pub Date : 2016-01-01 Epub Date: 2015-07-11 DOI: 10.1007/s00542-015-2615-3
Mohd Zahid Ansari, Chongdu Cho
{"title":"An optimised silicon piezoresistive microcantilever sensor for surface stress studies.","authors":"Mohd Zahid Ansari, Chongdu Cho","doi":"10.1007/s00542-015-2615-3","DOIUrl":"10.1007/s00542-015-2615-3","url":null,"abstract":"<p><p>Surface stress is a versatile and efficient means to study various physical, chemical, biochemical and biological processes. This work focuses on developing high sensitive piezoresistive microcantilever designs to study surface stress. The cantilevers are made of silicon with rectangular holes at their base that also circumscribe a piezoresistor sensing element. To find the optimum design, the effects of change in cantilever width, rectangular hole length and type of dopant on mechanical properties like deflection, frequency and maximum stress are characterised using finite element analysis software. The surface stress sensitivity characteristics of the different cantilever designs is ascertained by applying a surface stress on their top surfaces. Results show that the sensitivity is increased by increasing the cantilever width as well as the length of the hole and the sensitivity of p-type designs is more than two times the n-type.</p>","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"22 9","pages":"2279-2285"},"PeriodicalIF":2.1,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s00542-015-2615-3","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"37773095","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Arrays of High-Aspect Ratio Microchannels for High-Throughput Isolation of Circulating Tumor Cells (CTCs). 用于高通量分离循环肿瘤细胞 (CTC) 的高宽比微通道阵列。
IF 2.1 4区 工程技术
Mateusz L Hupert, Joshua M Jackson, Hong Wang, Małgorzata A Witek, Joyce Kamande, Matthew I Milowsky, Young E Whang, Steven A Soper
{"title":"Arrays of High-Aspect Ratio Microchannels for High-Throughput Isolation of Circulating Tumor Cells (CTCs).","authors":"Mateusz L Hupert, Joshua M Jackson, Hong Wang, Małgorzata A Witek, Joyce Kamande, Matthew I Milowsky, Young E Whang, Steven A Soper","doi":"10.1007/s00542-013-1941-6","DOIUrl":"10.1007/s00542-013-1941-6","url":null,"abstract":"<p><p>Microsystem-based technologies are providing new opportunities in the area of in vitro diagnostics due to their ability to provide process automation enabling point-of-care operation. As an example, microsystems used for the isolation and analysis of circulating tumor cells (CTCs) from complex, heterogeneous samples in an automated fashion with improved recoveries and selectivity are providing new opportunities for this important biomarker. Unfortunately, many of the existing microfluidic systems lack the throughput capabilities and/or are too expensive to manufacture to warrant their widespread use in clinical testing scenarios. Here, we describe a disposable, all-polymer, microfluidic system for the high-throughput (HT) isolation of CTCs directly from whole blood inputs. The device employs an array of high aspect ratio (HAR), parallel, sinusoidal microchannels (25 µm × 150 µm; W × D; AR = 6.0) with walls covalently decorated with anti-EpCAM antibodies to provide affinity-based isolation of CTCs. Channel width, which is similar to an average CTC diameter (12-25 µm), plays a critical role in maximizing the probability of cell/wall interactions and allows for achieving high CTC recovery. The extended channel depth allows for increased throughput at the optimized flow velocity (2 mm/s in a microchannel); maximizes cell recovery, and prevents clogging of the microfluidic channels during blood processing. Fluidic addressing of the microchannel array with a minimal device footprint is provided by large cross-sectional area feed and exit channels poised orthogonal to the network of the sinusoidal capillary channels (so-called Z-geometry). Computational modeling was used to confirm uniform addressing of the channels in the isolation bed. Devices with various numbers of parallel microchannels ranging from 50 to 320 have been successfully constructed. Cyclic olefin copolymer (COC) was chosen as the substrate material due to its superior properties during UV-activation of the HAR microchannels surfaces prior to antibody attachment. Operation of the HT-CTC device has been validated by isolation of CTCs directly from blood secured from patients with metastatic prostate cancer. High CTC sample purities (low number of contaminating white blood cells, WBCs) allowed for direct lysis and molecular profiling of isolated CTCs.</p>","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"20 10-11","pages":"1815-1825"},"PeriodicalIF":2.1,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4207852/pdf/nihms536593.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"32775682","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A novel microneedle array for the treatment of hydrocephalus. 一种治疗脑积水的新型微针阵列。
IF 2.1 4区 工程技术
Jonghyun Oh, Kewei Liu, Tim Medina, Francis Kralick, Hongseok Moses Noh
{"title":"A novel microneedle array for the treatment of hydrocephalus.","authors":"Jonghyun Oh,&nbsp;Kewei Liu,&nbsp;Tim Medina,&nbsp;Francis Kralick,&nbsp;Hongseok Moses Noh","doi":"10.1007/s00542-013-1988-4","DOIUrl":"https://doi.org/10.1007/s00542-013-1988-4","url":null,"abstract":"<p><p>We present a microfabricated 10 by 10 array of microneedles for the treatment of a neurological disease called communicating hydrocephalus. Together with the previously reported microvalve array, the current implantable microneedle array completes the microfabricated arachnoid granulations (MAGs) that mimic the function of normal arachnoid granulations (AGs). The microneedle array was designed to enable the fixation of the MAGs through dura mater membrane in the brain and thus provide a conduit for the flow of cerebrospinal fluid (CSF). Cone-shaped microneedles with hollow channels were fabricated using a series of microfabrication techniques: SU-8 photolithography for tapered geometry, reactive ion etching for sharpening the microneedles, 248 nm deep UV excimer laser machining for creating through-hole inside the microneedles, and metal sputtering for improved rigidity. Puncture tests were conducted using porcine dura mater and the results showed that the fabricated microneedle array is strong enough to pierce the dura mater. The <i>in-vitro</i> biocompatibility test result showed that none of the 100 outlets of the microneedles exposed to the bloodstream were clogged significantly by blood cells. We believe that these test results demonstrate the potential use of the microneedle array as a new treatment of hydrocephalus.</p>","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"20 6","pages":"1169-1179"},"PeriodicalIF":2.1,"publicationDate":"2014-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s00542-013-1988-4","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"32497553","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
A microacoustic analysis including viscosity and thermal conductivity to model the effect of the protective cap on the acoustic response of a MEMS microphone. 微声分析包括粘度和热导率,以模拟保护帽对MEMS麦克风声响应的影响。
IF 2.1 4区 工程技术
D Homentcovschi, R N Miles, P V Loeppert, A J Zuckerwar
{"title":"A microacoustic analysis including viscosity and thermal conductivity to model the effect of the protective cap on the acoustic response of a MEMS microphone.","authors":"D Homentcovschi,&nbsp;R N Miles,&nbsp;P V Loeppert,&nbsp;A J Zuckerwar","doi":"10.1007/s00542-013-1800-5","DOIUrl":"https://doi.org/10.1007/s00542-013-1800-5","url":null,"abstract":"<p><p>An analysis is presented of the effect of the protective cover on the acoustic response of a miniature silicon microphone. The microphone diaphragm is contained within a small rectangular enclosure and the sound enters through a small hole in the enclosure's top surface. A numerical model is presented to predict the variation in the sound field with position within the enclosure. An objective of this study is to determine up to which frequency the pressure distribution remains sufficiently uniform so that a pressure calibration can be made in free space. The secondary motivation for this effort is to facilitate microphone design by providing a means of predicting how the placement of the microphone diaphragm in the package affects the sensitivity and frequency response. While the size of the package is typically small relative to the wavelength of the sounds of interest, because the dimensions of the package are on the order of the thickness of the viscous boundary layer, viscosity can significantly affect the distribution of sound pressure around the diaphragm. In addition to the need to consider viscous effects, it is shown here that one must also carefully account for thermal conductivity to properly represent energy dissipation at the system's primary acoustic resonance frequency. The sound field is calculated using a solution of the linearized system consisting of continuity equation, Navier-Stokes equations, the state equation and the energy equation using a finite element approach. The predicted spatial variation of both the amplitude and phase of the sound pressure is shown over the range of audible frequencies. Excellent agreement is shown between the predicted and measured effects of the package on the microphone's sensitivity.</p>","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"20 2","pages":"265-272"},"PeriodicalIF":2.1,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s00542-013-1800-5","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"32236463","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
A water-immersible 2-axis scanning mirror microsystem for ultrasound andha photoacoustic microscopic imaging applications. 用于超声和光声显微成像应用的水浸式两轴扫描镜微系统。
IF 2.1 4区 工程技术
Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems Pub Date : 2013-01-01 Epub Date: 2012-09-13 DOI: 10.1007/s00542-012-1660-4
Chih-Hsien Huang, Junjie Yao, Lihong V Wang, Jun Zou
{"title":"A water-immersible 2-axis scanning mirror microsystem for ultrasound andha photoacoustic microscopic imaging applications.","authors":"Chih-Hsien Huang,&nbsp;Junjie Yao,&nbsp;Lihong V Wang,&nbsp;Jun Zou","doi":"10.1007/s00542-012-1660-4","DOIUrl":"https://doi.org/10.1007/s00542-012-1660-4","url":null,"abstract":"<p><p>Fast scanning is highly desired for both ultrasound and photoacoustic microscopic imaging, whereas the liquid environment required for acoustic propagation limits the usage of traditional microelectromechanical systems (MEMS) scanning mirrors. Here, a new water-immersible scanning mirror microsystem has been designed, fabricated and tested. To achieve reliable underwater scanning, flexible polymer torsion hinges fabricated by laser micromachining were used to support the reflective silicon mirror plate. Two efficient electromagnetic microactuators consisting of compact RF choke inductors and high-strength neodymium magnet disc were constructed to drive the silicon mirror plate around a fast axis and a slow axis. The performance of this water-immersible scanning mirror microsystem in both air and water were tested using the laser tracing method. For the fast axis, the resonance frequency reached 224 Hz in air and 164 Hz in water, respectively. The scanning angles in both air and water under ±16 V DC driving were ±12°. The scanning angles in air and water under ±10 V AC driving (at the resonance frequencies) were ±13.6° and ±10°. For the slow axis, the resonance frequency reached 55 Hz in air and 38 Hz in water, respectively. The scanning angles in both air and water under ±10 V DC driving were ±6.5°. The scanning angles in air and water under ±10 V AC driving (at the resonance frequencies) were ±8.5° and ±6°. The feasibility of using such a water-immersible scanning mirror microsystem for scanning ultrasound microscopic imaging has been demonstrated with a 25-MHz ultrasound pulse/echo system and a target consisting of three optical fibers.</p>","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"19 4","pages":"577-582"},"PeriodicalIF":2.1,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s00542-012-1660-4","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38883993","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 26
Design, modeling and characterization of stable, high Q-factor curved Fabry---Pérot cavities 稳定、高q因子弯曲法布里-帕氏腔的设计、建模和表征
IF 2.1 4区 工程技术
MalakMaurine, PavyNicolas, MartyFrédéric, RichalotElodie, LiuAi-Qun, BourouinaTarik
{"title":"Design, modeling and characterization of stable, high Q-factor curved Fabry---Pérot cavities","authors":"MalakMaurine, PavyNicolas, MartyFrédéric, RichalotElodie, LiuAi-Qun, BourouinaTarik","doi":"10.5555/3112039.3112372","DOIUrl":"https://doi.org/10.5555/3112039.3112372","url":null,"abstract":"In this paper, we introduce a novel design for high performance silicon-based Fabry---Perot cavities and their corresponding design model. According to the design model, the new design shows higher...","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"24 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2011-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83237124","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Novel interconnection technology for heterogeneous integration of MEMS–LSI multi-chip module MEMS-LSI多芯片模块异构集成互连新技术
IF 2.1 4区 工程技术
LeeKang-Wook, KoyanagiMitsumasa
{"title":"Novel interconnection technology for heterogeneous integration of MEMS–LSI multi-chip module","authors":"LeeKang-Wook, KoyanagiMitsumasa","doi":"10.5555/1712972.1712984","DOIUrl":"https://doi.org/10.5555/1712972.1712984","url":null,"abstract":"We developed novel interconnection technology for heterogeneous integration of MEMS and LSI multi-chip module, in which MEMS and LSI chips would be horizontally integrated on substrate and vertical...","PeriodicalId":49813,"journal":{"name":"Microsystem Technologies-Micro-And Nanosystems-Information Storage and Processing Systems","volume":"7 1","pages":""},"PeriodicalIF":2.1,"publicationDate":"2009-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"78989395","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信