2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)最新文献

筛选
英文 中文
Nanostructure-enabled significant thermal transport enhancement across solid interfaces 纳米结构显著增强了固体界面间的热输运
T. Jiang, Eungkyu Lee, M. Young, T. Luo
{"title":"Nanostructure-enabled significant thermal transport enhancement across solid interfaces","authors":"T. Jiang, Eungkyu Lee, M. Young, T. Luo","doi":"10.1109/ITHERM.2016.7517610","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517610","url":null,"abstract":"The efficiency of thermal transport across the interfaces presents large challenges for modern technologies such as thermal management of electronics. In this paper, we report significant enhancement of thermal transport across solid interfaces by nanopatterning the surface. We utilized nanopillars as the analogy of fins that have been used for macroscopic heat transfer enhancement in heat exchangers. We found that the major benefit sterns from the enlarged effective contact area due to the increased surface area of the nanopatterned surface. The finding from this work should be universal and can benefit the thermal management of electronics, especially high power electronics where self-heating has been a bottleneck for their further advancement.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"135 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123650081","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Numerical modeling and thermal enhancement of finned tube heat exchanger with guiding channel and fusiform configurations 导向通道和梭形翅片管换热器的数值模拟及热强化
Chuan Sun, Nuttawut Lewpiriyawong, Kent Loong Khoo, P. Lee, S. Chou
{"title":"Numerical modeling and thermal enhancement of finned tube heat exchanger with guiding channel and fusiform configurations","authors":"Chuan Sun, Nuttawut Lewpiriyawong, Kent Loong Khoo, P. Lee, S. Chou","doi":"10.1109/ITHERM.2016.7517670","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517670","url":null,"abstract":"As the air-side heat transfer is controlling the efficiency of finned tube heat exchanger (FTHX), this makes its enhancement important. After analyzing the thermal hydraulic performance of conventional plain plate fin, two novel air-side fin configurations are proposed. The first design guides more airflow into the back of the tubes and eliminates wake zones. The second design significantly enlarges the heat transfer area of air-side with little pressure drop penalty. Numerical investigations of conventional and novel fin designs are conducted. Based on the temperature and velocity flow fields and Nusselt number (Nu), the two novel designs are repeatedly improved. Comparing Nu and friction factor (f) with the plain plate fin, the two novel fin designs enhance the overall thermal performance by 103.1-109.0% and 64.5-78.4% respectively, while incurring pressure drop penalty of 312.8-419.6% and (- 1.5)-6.0% respectively. As such, the proposed enhanced air-side fin designs are promising candidates for improving the efficiency for FTHXs.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124939911","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Reliability of a CBGA miroproessor package incorpoating a decoupling capacitor array 采用去耦电容阵列的CBGA微处理器封装的可靠性
J. Roberts, C. Bhat, J. Suhling, R. Jaeger, P. Lall
{"title":"Reliability of a CBGA miroproessor package incorpoating a decoupling capacitor array","authors":"J. Roberts, C. Bhat, J. Suhling, R. Jaeger, P. Lall","doi":"10.1109/ITHERM.2016.7517561","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517561","url":null,"abstract":"In this work, the reliability of a novel advanced packaging design for microprocessors has been explored. The new architecture consists of a Ceramic Ball Grid Array (CBGA) package with a flip chip die on a high CTE ceramic substrate, and an array of decoupling capacitors used within the second level interconnects. The capacitors are modified chip capacitors that are soldered immediately beneath the CBGA substrate in a square array that replaces some or all of the ball grid array solder joints. This location for the capacitors improves electrical performance of the microprocessor package (reduces noise/crosstalk and increases speed), and also provides resistance to solder joint collapse. The value of the designs in this investigation is in moving the decoupling capacitive elements of the package closer to the die while having a comparable mechanical reliability to an analogous BGA package. Test assemblies of the new packaging concept containing daisy chain test die have been prepared and subjected to thermal cycling reliability testing. Both lead free and Sn-Pb solder joint options have been examined. Weibull failure plots of the recorded failure data have been created, and failure analysis has been performed to identify failure locations and failure modes.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"217 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127960116","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Flow boiling of R245fa in a microgap with integrated staggered pin fins R245fa在集成交错针翅微隙中的流动沸腾
Pouya Asrar, Xuchen Zhang, Casey D. Woodrum, C. Green, P. Kottke, Thomas E. Sarvey, S. Sitaraman, A. Fedorov, M. Bakir, Y. Joshi
{"title":"Flow boiling of R245fa in a microgap with integrated staggered pin fins","authors":"Pouya Asrar, Xuchen Zhang, Casey D. Woodrum, C. Green, P. Kottke, Thomas E. Sarvey, S. Sitaraman, A. Fedorov, M. Bakir, Y. Joshi","doi":"10.1109/ITHERM.2016.7517656","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517656","url":null,"abstract":"We present an experimental study of two phase flow of refrigerant R245fa in a pin fin enhanced microgap for a range of heat fluxes between 151 W/cm2 to 326 W/cm2. The gap has a base surface area of 1cm × 1cm and height of 200 μm. An array of hydrofoil shaped pin fins covers from bottom to top of the microgap. The pin fins have chord length, longitudinal pitch, and transversal pitch of 75μm, 450μm and 225μm, respectively. On the back side of the chip, four platinum heaters are fabricated and electrically powered in series to enable two phase flow in the microgap, which was part of a pumped flow loop. Heater and surface temperature data were obtained versus heat flux dissipated. Flow visualization was performed using a high speed camera in the heat flux range from 151 W/cm2 to 326 W/cm2. The amount of heat loss across the test section is also provided.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126968113","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Temperature distribution in a circular flux tube with arbitrary specified contact temperatures 具有任意指定接触温度的圆形磁通管内的温度分布
M. Razavi, Y. Muzychka, S. Kocabiyik
{"title":"Temperature distribution in a circular flux tube with arbitrary specified contact temperatures","authors":"M. Razavi, Y. Muzychka, S. Kocabiyik","doi":"10.1109/ITHERM.2016.7517648","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517648","url":null,"abstract":"Temperature profile of electronic devices is one of the key factors that should be considered for designing an effective thermal management system. In this paper, an analytical solution for temperature distribution of a circular flux tube is presented. The boundary conditions along the source plane are specified as arbitrary temperatures and adiabatic. The boundary condition along the sink plane is convective cooling and the boundary condition along the walls is adiabatic. For solving the governing equation, the method of separation of variables and the least squares method are used. A case study is presented and the results are compared with the Finite Element Method (FEM). This analytical solution helps thermal engineers to have a better understanding of the thermal behavior of electronic devices.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"72 1-2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114008966","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Correlation for single phase liquid jet impingement with an angled confining wall for power electronics cooling 电力电子冷却中单相液体射流冲击与倾斜围壁的关系
J. Maddox, R. Knight, S. Bhavnani, James Pool
{"title":"Correlation for single phase liquid jet impingement with an angled confining wall for power electronics cooling","authors":"J. Maddox, R. Knight, S. Bhavnani, James Pool","doi":"10.1109/ITHERM.2016.7517642","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517642","url":null,"abstract":"An apparatus was developed to measure the local surface temperature, local heat flux, and local heat transfer coefficient for a 3 × 3 array of circular, normal, single-phase liquid water jets impinging on a copper surface. The local thermal measurements were used to obtain the average Nusselt number for the central jet. An angled confining wall was used to manage the spent fluid by maintaining a consistent crossflow momentum ratio with downstream position, which prevents degradation in the thermal performance of downstream jets. A correlation describing the average Nusselt number as a function of jet Reynolds number, Prandtl number, confining wall angle, nozzle to plate spacing, and nozzle pitch for single phase circular water jets is presented.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129059997","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A numerical study of the effect of thermal radiation on the forced air cooling of low heat flux electronic chips mounted on one side of a vertical channel 热辐射对安装在垂直通道一侧的低热流密度电子芯片强制空气冷却影响的数值研究
R. Dhingra, P. Ghoshdastidar
{"title":"A numerical study of the effect of thermal radiation on the forced air cooling of low heat flux electronic chips mounted on one side of a vertical channel","authors":"R. Dhingra, P. Ghoshdastidar","doi":"10.1109/ITHERM.2016.7517671","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517671","url":null,"abstract":"A numerical study of steady, laminar, two-dimensional combined convection and radiation air cooling of four identical rectangular electronic chips (made of silicon) mounted on the left side of a vertical channel is presented in this paper. The conduction in the walls (composed of copper-epoxy) as well as in the chips in which energy is generated due to joule heating is also taken into account. The outside walls are treated as insulated. At the channel inlet the velocity is uniform. The stream function-vorticity-temperature approach with the finite-difference-based methodology has been applied to obtain flow and thermal fields in the fluid, temperature distributions in the chips and the walls, and pressure distribution in the fluid. The parameters varied to study the effect of radiation on the cooling of the silicon chips are: Reynolds number, Grashof number, emissivity of the chips and of the inside wall surfaces, chip height, chip width, and the gap between the successive chips. The energy generation rate is such that it gives rise to average heat flux in the chips in the range of 281.25 W/m2 to 1.875×103 W/m2, which is relatively low. The results reveal that there is a 14.28% drop in the dimensionless maximum temperature of the chips at Re = 500, Gr = 8.65 × 105 as compared to the case when the radiation effect is not considered. The increase in emissivity of the chips from 0.1 to 0.9 results in considerable rise in the temperature of the wall opposite to the chips accompanied by a small drop in the chip temperature. The pumping power increases by 82.69% when the chip height is increased from 0.3 to 0.6. However, increasing the chip width results in rise in pumping power by 30%. There is only a marginal drop in pumping power requirement when radiation is considered in the modeling. The novelty of this work lies in the use of realistic chip and wall materials, investigation of the effect of various geometrical parameters, calculation of pressure distribution and pumping power, and reporting of radiation effect on the walls opposite to the chips. This is only work so far which solves the flow, thermal and pressure fields in electronics cooling using stream function-vorticity-temperature approach and applies Gebhart's absorption factor method for calculation of radiation exchange.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131414882","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A novel Micro-CT data based Finite Element Modeling technique to study reliability of densely packed fuze assemblies 一种新的基于微ct数据的有限元建模技术来研究密装引信组件的可靠性
P. Lall, Nakul Kothari, J. Foley, John Deep, Ryan Lowe
{"title":"A novel Micro-CT data based Finite Element Modeling technique to study reliability of densely packed fuze assemblies","authors":"P. Lall, Nakul Kothari, J. Foley, John Deep, Ryan Lowe","doi":"10.1109/ITHERM.2016.7517584","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517584","url":null,"abstract":"Densely packed electrical assemblies like fuze, contain large number of components, potted in protective adhesives. The number of components, varying material types, irregular geometry of the components and the geometric details of the assembly makes conventional CAD modeling, meshing and Finite Element(FE) modeling of these large assemblies extremely time consuming, often, to the extent of being impractical. CAD geometries compatible with modern Finite Element (FE) platforms may not be available for several legacy systems. Furthermore, conventional CAD modeling may not account for the real geometry realized after the manufacturing process and this can often affect the fidelity of the FE model. There is no method for capturing the actual assembly geometry and its embedded components. Assessment of survivability of fuzes requires assessment of stresses and strains under operational loads. Previously, researchers have studied the reliability of key components in a fuze device subjected to high temperature and high g mechanical shocks [1]. Researchers have measured redundancy and reliability of fuze electronics using failure rates and mean time to failure as per MIL-HDBK-217F standard [2]. There is little to no literature on FE modeling of a comprehensive fuze assembly. In this paper, a methodology for the creation of an FE model based on Micro-CT (Computed Tomography) data is presented. The method has been applied to an actual fuze subjected to mechanical shock. This method involves usage of advanced 3D imaging, image segmentation, image filtering and meshing techniques to directly convert CT scanned electrical assemblies into a FE mesh. This method successfully bypasses the time consuming CAD modeling step of conventional FE modeling. The as-is geometry of each component, positioned accurately in a 3D space, as per the original assembly, has been realized in this process by usage of micro-CT scanning technique. The submicron scale tolerances of the CT scanned data ensure true representation of the fuze assembly, in this case. The FE model thus realized, allows for measurement of all the field variables, anywhere over its meshed domain. Stress and strain histories have been extracted for embedded components of the fuze assembly using explicit finite element models.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121361913","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Thermal raman and IR measurement of heterogeneous integration stacks 异质集成电路的热拉曼和红外测量
T. R. Harris, G. Pavlidis, Eric J. Wyers, D. Marshal Newberry, S. Graham, P. Franzon, W. R. Davis
{"title":"Thermal raman and IR measurement of heterogeneous integration stacks","authors":"T. R. Harris, G. Pavlidis, Eric J. Wyers, D. Marshal Newberry, S. Graham, P. Franzon, W. R. Davis","doi":"10.1109/ITHERM.2016.7517727","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517727","url":null,"abstract":"Thermal management and planning is important for heterogeneous integration due to the introduction of a complex thermal path. Thermal measurement of operating devices provides necessary data points for future design as well as validation of models. In this paper, two methods for measuring thermal performance of DAHI (Diverse Accessible Heterogeneous Integration) GaN HEMTs are presented and contrasted: IR microscopy and micro Raman spectroscopy. The QFI IR system uses a per-pixel material emissivity flat temperature calibration when the device is in an off-state, and then calculates operating temperatures by CCD exposure. Two separate QFI systems with differing CCD resolutions were used to collect thermal data and are compared. Raman Thermometry by contrast, is a laser point measurement of the frequency shift in scattered photons due to phonon vibrational modes whose frequencies are temperature dependent. Differences in measurements between the two methods arising from the stack of materials used in the DAHI process and their transparency are discussed. A method for measuring the surface temperature of the devices through Raman by the use of TiO2 nanoparticles is also presented in conjunction with a profile of the HEMT. Measurements are presented alongside thermal simulation results using prototype software Mentor Graphics™ Calibre®.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116026207","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Two-phase mini-thermosyphon electronics cooling, Part 2: Model and steady-state validations 两相微型热虹吸电子冷却,第2部分:模型和稳态验证
J. Marcinichen, N. Lamaison, C. L. Ong, J. Thome
{"title":"Two-phase mini-thermosyphon electronics cooling, Part 2: Model and steady-state validations","authors":"J. Marcinichen, N. Lamaison, C. L. Ong, J. Thome","doi":"10.1109/ITHERM.2016.7517600","DOIUrl":"https://doi.org/10.1109/ITHERM.2016.7517600","url":null,"abstract":"In the present study, a simulation code specifically developed to evaluate the thermal-hydraulic performance of thermosyphon cooling loops is validated through the experimental results obtained in the Part 1. It considers levels of heat load conventionally observed in real servers of datacenters, which means idle, normal and maximum clock speed of actual microprocessors. The thermosyphon is a very compact unit with a height of 15 cm and capable of safely operating up to a heat flux of 80 W cm-2. The loop basically is comprised of a riser, a downcomer, a micro-evaporator and a counter flow tube-in-tube condenser. The latter is cooled by cold water whose mass flow rate can be controlled through an external pump (speed control), so that parameters such as saturation temperature and/or condenser outlet subcooling can be adjusted for a pre-defined set point, and thus increasing the range of operability of the cooling loop. Other parameters were also explored experimentally, cooling looping overall performance, chip (junction) temperature, whilst the critical heat flux was estimated from a leading CHF method. Finally, the study showed that the passive two-phase closed loop thermosyphon cooling system is a safe and energetically viable technology solution for the next generation of datacenters.","PeriodicalId":426908,"journal":{"name":"2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"143 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116950256","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信