Fuzzy Logic Based Protective Relaying Scheme for IEEE-39 Bus Transmission System 基于模糊逻辑的IEEE-39总线传输保护继电保护方案
S. Sahu, Anamika Yadav
{"title":"Fuzzy Logic Based Protective Relaying Scheme for IEEE-39 Bus Transmission System","authors":"S. Sahu, Anamika Yadav","doi":"10.1109/EPETSG.2018.8658630","DOIUrl":"https://doi.org/10.1109/EPETSG.2018.8658630","url":null,"abstract":"Nowadays electricity becomes the most important and necessary things for human beings. So for proper operation, reliable power supply is needed. In this paper fuzzy logic method is used for detection of fault and its classification. In this method, voltage and current at one end of the transmission line is used for fault detection and classification. This fault detection method is tested on IEEE-39 bus transmission system using MATLAB software. This protection scheme detects all symmetrical and unsymmetrical faults accurately.","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132707569","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Multi Sensitivity Factors and FPA for Loss Reduction and Voltage Profile Improvement by Optimal Placement and Sizing of Capacitor in Mesh Network 网状网络中电容器优化布局和尺寸的多灵敏度因子和FPA降低损耗和改善电压分布
Ankita, Prem Prakash
{"title":"Multi Sensitivity Factors and FPA for Loss Reduction and Voltage Profile Improvement by Optimal Placement and Sizing of Capacitor in Mesh Network","authors":"Ankita, Prem Prakash","doi":"10.1109/EPETSG.2018.8659003","DOIUrl":"https://doi.org/10.1109/EPETSG.2018.8659003","url":null,"abstract":"In the present scenario, the demand for electricity has increased drastically. To meet the increased demand transmission line operates near their operating limit. Power system is unable to meet the increased load demand, and this causes deficiency of both active and reactive power. Reactive power compensation is used to improve the voltage profile of the system; it is one of the most effective ways of enhancing the working situation of transmission. The main apprehension in the effective reactive power compensation is location and size of VAR supporting devices in the transmission network. In the present work to achieve effective management of reactive power three sensitivity factors i.e. Voltage Sensitivity Factor (VSF), Voltage Stability Index (VSI), and Loss Sensitivity Factor (LSF)have been used for finding the suitable candidate bus for reactive power support and thereafter Flower Pollination Algorithm (FPA)have been used for finding the optimal quantity of the reactive power support. The obtained results are compared with the general case when only one of the sensitivity factors is used. The complete technique is tested on the IEEE-24 bus system.","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133719565","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
[Copyright notice] (版权)
{"title":"[Copyright notice]","authors":"","doi":"10.1109/epetsg.2018.8658523","DOIUrl":"https://doi.org/10.1109/epetsg.2018.8658523","url":null,"abstract":"","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"96 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132369325","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fuzzy Logic Based Control Algorithm for DSTATCOM Connected to Weak AC Grid DSTATCOM接入弱交流电网的模糊控制算法
Gajendra Singh Chawda, Abdul Gafoor Shaik
{"title":"Fuzzy Logic Based Control Algorithm for DSTATCOM Connected to Weak AC Grid","authors":"Gajendra Singh Chawda, Abdul Gafoor Shaik","doi":"10.1109/EPETSG.2018.8659093","DOIUrl":"https://doi.org/10.1109/EPETSG.2018.8659093","url":null,"abstract":"This paper presents a fuzzy logic based synchronous reference frame algorithm for distribution static compensator to enhance the power quality of a weak AC grid. The proposed algorithm maintains constant DC-link voltage and extracts fundamental weighted values of load currents to es timate reference current. Thes e reference currents are utilized by DSTATCOM to mitigate the power quality. This control algorithm has been tested success fully in regulating the vol tage, mi tigating the harmonics, and load balancing for different types of loads at the point of common coupling.","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130272033","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
The Torque Simulation of Synchronous Generator Under Loaded Condition for Different Types of Electrical Disturbances 不同类型电干扰下同步发电机负载状态转矩仿真
T. Kumar, Abhishek Bangunde, Rajeev Kumar, Prof. Satish Chandra Jain
{"title":"The Torque Simulation of Synchronous Generator Under Loaded Condition for Different Types of Electrical Disturbances","authors":"T. Kumar, Abhishek Bangunde, Rajeev Kumar, Prof. Satish Chandra Jain","doi":"10.1109/EPETSG.2018.8659271","DOIUrl":"https://doi.org/10.1109/EPETSG.2018.8659271","url":null,"abstract":"In this paper, the torque developed in the synchronous generator under the loaded condition is numerically simulated for various types of electrical faults. The dq0 approach is used to model synchronous generator connected to an infinite bus. The Adams fourth order predictor-corrector method with starter as fourth order Runge-Kutta method is used to numerically simulate the torque developed by the synchronous generator connected to load using MATLAB. The numerical results revealed that electromagnetic torque is most severe in synchronization fault followed by three phase fault, line to ground fault and line to line fault.","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114306423","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Optimal Selection of Voltage Sag Mitigating Devices Using Whale Optimization Algorithm for Small and Medium Sized Customers in Distribution System 基于鲸鱼优化算法的配电系统中小用户电压暂降缓解装置的优化选择
Rituparna Mitra, Sadhan Gope, A. Goswami, P. Tiwari
{"title":"Optimal Selection of Voltage Sag Mitigating Devices Using Whale Optimization Algorithm for Small and Medium Sized Customers in Distribution System","authors":"Rituparna Mitra, Sadhan Gope, A. Goswami, P. Tiwari","doi":"10.1109/EPETSG.2018.8658703","DOIUrl":"https://doi.org/10.1109/EPETSG.2018.8658703","url":null,"abstract":"Small and medium sized customers emerge and plays a pivotal role in modern times due to rapid urbanization. Small and medium customers are constituted by domestic user, big malls, hospitals, educational institutions, medium and small sized traders. This medium and tiny sector deserves uninterrupted hassle free and quality power for their daily run. Interruption in power distribution affects distributors' image, revenue lost (cost incurred for production of power is not recovered from clientele) can be eradicated by using the concept of placing voltage sag mitigating devices. Optimal selection of voltage sag mitigating devices is based on the parameters like capacity, size, cost and load factors (for specific placement of devices). Whale optimization algorithm has been applied as tool. Loss of energy/power is avoided culminating save of energy and economic gain.","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116713624","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Water Hyacinth Derived Mixed-Oxide Heterogeneous Catalyst for Biodiesel Production 水葫芦衍生的混合氧化物多相催化剂用于生物柴油生产
Minakshi Gohain, D. Deka
{"title":"Water Hyacinth Derived Mixed-Oxide Heterogeneous Catalyst for Biodiesel Production","authors":"Minakshi Gohain, D. Deka","doi":"10.1109/EPETSG.2018.8658926","DOIUrl":"https://doi.org/10.1109/EPETSG.2018.8658926","url":null,"abstract":"Homogeneous catalytic system for biodiesel synthesis is no longer justifiable by industries in the near future; mainly due to ecological issues related to the conventional homogeneous catalytic system like problems associated with separation of the catalyst from the product, reusability, and its release into the environment after washing the catalyst from the product. The present study is focused on the viability of environmentally benign heterogeneous catalyst synthesis from water hyacinth (WH) a renewable aquatic plant considered hazard for other useful aquatic crops. The synthesized catalyst was characterized by fourier transform infrared spectroscopy (FTIR), powder X-ray diffractograms (XRD), energy dispersive analysis of X-ray (EDAX), brunauer-emmett-teller (BET), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and hammett indicator analysis. The catalyst demonstrated a superior catalytic performance achieving fatty acid methyl esters (FAME) conversion of 97.1 % in 3 h. The catalyst could be reused efficiently with FAME conversion of more than 80 % after the third cycles. The present work reveals the possibility of developing heterogeneous catalyst from an aquatic weed for FAME synthesis, reducing the total production cost of biodiesel synthesis.","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133001250","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Soft Computational Technique to Estimate Inflow for Fault Detection in Control Valve 用于控制阀故障检测的流量估计软计算技术
K. Santhosh, Bhagya R. Navada
{"title":"Soft Computational Technique to Estimate Inflow for Fault Detection in Control Valve","authors":"K. Santhosh, Bhagya R. Navada","doi":"10.1109/EPETSG.2018.8658834","DOIUrl":"https://doi.org/10.1109/EPETSG.2018.8658834","url":null,"abstract":"A sensor less flow measurement technique is proposed in this paper. The objective of the proposed work is to design an observer which can estimate the inflow to the control valve by soft computation techniques, so as to detect the faults in the control valve. Orifice flow meter is placed at the outlet of the control valve for measurement of outflow. By analyzing the behavior of control valve for different input signal, in flow to the control valve is estimated. Control valve works on the principle of regulating the inflow based on the control signal. Performance of the control valve can be established by measuring outflow, by knowing input signal and estimation of inflow to the control valve. To estimate the inflow, neural network based model is incorporated in the proposed work. Designed estimator is compared with the standard signal to evaluate the performance. The root mean square of percentage error of 0.91 shows successful design of estimator.","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122120963","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Full Bridge Based Level Doubling Network for Reduced Capacitance 降低电容的全桥式电平加倍网络
Rajesh Vasu, S. Chattopadhyay, C. Chakraborty
{"title":"Full Bridge Based Level Doubling Network for Reduced Capacitance","authors":"Rajesh Vasu, S. Chattopadhyay, C. Chakraborty","doi":"10.1109/EPETSG.2018.8658718","DOIUrl":"https://doi.org/10.1109/EPETSG.2018.8658718","url":null,"abstract":"A capacitor-fed half-bridge can be used as a Level Doubling Network (LDN) and when connected to any multilevel inverter unit, it can double the number of levels. Closed loop voltage balancing techniques are not required for maintaining the desired capacitor voltage. The capacitor of the half bridge based LDN, has to be in charging operation for half-a-cycle and discharging for the rest half. This results in a large voltage ripple across the capacitor, during low frequency operation of the inverter. A large value of capacitance is required to suppress the ripple voltage. This paper presents a method to reduce the size of LDN capacitor keeping the voltage ripple within limits by extending the half-bridge LDN to full-bridge. Working principle of the proposed method is validated by simulation in MATLABI Simulink and experimentation on a laboratory prototype.","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124852919","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
GCD Based Blind Super-Resolution for Remote Sensing Applications 基于GCD的盲超分辨率遥感应用
Neerav Sharma, P. P. Dash, Priyanka Saxena
{"title":"GCD Based Blind Super-Resolution for Remote Sensing Applications","authors":"Neerav Sharma, P. P. Dash, Priyanka Saxena","doi":"10.1109/EPETSG.2018.8658528","DOIUrl":"https://doi.org/10.1109/EPETSG.2018.8658528","url":null,"abstract":"The importance of remote sensing imageries is growing day by day. Extraction of fine details of desired regions worth for further processing and decision making. Usually the data bases of remote sensing imageries are very huge that overburden the processor. Super-Resolution overcomes this problem and yields a high-quality output in less time consumption. This paper aims to give a brief idea about one of the approaches of super-resolution known as blind super-resolution reconstruction approach. In this approach, Greatest Common Divisor (GCD) algorithm is embedded into the blind reconstruction technique. The HR images obtained from this method is compared with the interpolated images. The results shows the efficacy of the proposed method. The paper tries to overcome the limitations of the super resolution approach and a conclusive discussion of the whole method has been discussed.","PeriodicalId":385912,"journal":{"name":"2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology (ICEPE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126123345","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信