International Journal of Power Electronics and Drive Systems最新文献

筛选
英文 中文
Design of a continuously and linearly controlled VSI-based STATCOM for load current balancing purposes 用于负载电流平衡的基于vsi的连续线性控制STATCOM的设计
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP183-198
Faris Asaad Abdulmunem, Abdulkareem Mokif Obais
{"title":"Design of a continuously and linearly controlled VSI-based STATCOM for load current balancing purposes","authors":"Faris Asaad Abdulmunem, Abdulkareem Mokif Obais","doi":"10.11591/IJPEDS.V12.I1.PP183-198","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP183-198","url":null,"abstract":"In this paper, load current balancing are reviewed in both three-wire and 4-wire systems taking into account linearity, harmonics injection, and control schemes. A linearized static compensator (STATCOM) based on H-bridge voltage source inverter (VSI). The proposed STATCOM is controlled in closed loop mode via equipping it with a new current controller. The DC capacitor voltage of the STATCOM is kept constant without using external energy injection or storage devices via shunting the DC capacitor with a suitable series filter. The simulation results of the current responses of the 220V, 50Hz STATCOM reveal continuous and linear performance during responding to reactive current demands from 123A inductive current to 227A capacitive current. The transition time required for the proposed STATCOM during treatment of a sudden change in reactive current demand from maximum inductive current to maximum capacitive current is less than 40ms. The steady state portions of the STATCOM current responses show pure sinusoids, thus the proposed STATCOM can be promoted as harmonic free static Var compensator. The closed loop continuous mode control and the considerable linearity of the proposed STATCOM promot it as a bipolar susceptance (capacitive and inductive) in applications of load current balancing systems in both three and four wire power systems.","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"12 1","pages":"183-198"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44341545","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Experimentally evaluating electrical outputs of a PV-T system in Jordan 约旦PV-T系统电输出的实验评估
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP421-430
I. Etier, S. Nijmeh, Mohammed Shdiefat, O. Al-Obaidy
{"title":"Experimentally evaluating electrical outputs of a PV-T system in Jordan","authors":"I. Etier, S. Nijmeh, Mohammed Shdiefat, O. Al-Obaidy","doi":"10.11591/IJPEDS.V12.I1.PP421-430","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP421-430","url":null,"abstract":"This experimental work is looking at the properties of photovoltaic/thermal (PV-T) system, which had designed to increase the output power of the PV panel for the climate of Zarqa, Jordan. Operating temperature of the PV module has a significant impact on the performance of the PV module. However, most of the radiation energy absorbed by the PV panel is converted into heat, which is normally lost and provides no value. In order to decrease the operating temperature of the PV panel, a water cooling system with a control system had designed. Experimentally, when the PV module was operating under active water-cooling condition using the backside cooling technique, the temperature dropped significantly, which led to an increase in the electrical efficiency of solar cells by 6.86%.","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"12 1","pages":"421-430"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45075202","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Adaptive dynamic programming algorithm for uncertain nonlinear switched systems 不确定非线性切换系统的自适应动态规划算法
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP551-557
Dao Phuong Nam, N. Quang, Nguyen Nhat Tung, T. P. H. Yen
{"title":"Adaptive dynamic programming algorithm for uncertain nonlinear switched systems","authors":"Dao Phuong Nam, N. Quang, Nguyen Nhat Tung, T. P. H. Yen","doi":"10.11591/IJPEDS.V12.I1.PP551-557","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP551-557","url":null,"abstract":"This paper studies an approximate dynamic programming (ADP) strategy of a group of nonlinear switched systems, where the external disturbances are considered. The neural network (NN) technique is regarded to estimate the unknown part of actor as well as critic to deal with the corresponding nominal system. The training technique is simul-taneously carried out based on the solution of minimizing the square error Hamilton function. The closed system’s tracking error is analyzed to converge to an attraction region of origin point with the uniformly ultimately bounded (UUB) description. The simulation results are implemented to determine the effectiveness of the ADP based controller.","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"12 1","pages":"551-557"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41794495","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Faults diagnosis in stator windings of high speed solid rotor induction motors using fuzzy neural network 基于模糊神经网络的高速固体转子异步电动机定子绕组故障诊断
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP597-611
A. Radhi, W. Zayer
{"title":"Faults diagnosis in stator windings of high speed solid rotor induction motors using fuzzy neural network","authors":"A. Radhi, W. Zayer","doi":"10.11591/IJPEDS.V12.I1.PP597-611","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP597-611","url":null,"abstract":"The paper deals with faults diagnosis method proposed to detect the inter-turn and turn to earth short circuit in stator winding of three-phase high-speed solid rotor induction motors. This method based on negative sequence current of motor and fuzzy neural network algorithm. On the basis of analysis of 2-D electromagnet field in the solid rotor the rotor impedance has been derived to develop the solid rotor induction motor equivalent circuit. The motor equivalent circuit is simulated by MATLAB software to study and record the data for training and testing the proposed diagnosis method. The numerical results of proposed approach are evaluated using simulation of a three-phase high-speed solid-rotor induction motor of two-pole, 140 Hz. The results of simulation shows that the proposed diagnosis method is fast and efficient for detecting inter-turn and turn to earth faults in stator winding of high-speed solid-rotor induction motors with different faults conditions","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"64369241","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Improving output current of inductor-cell based five-level CSI using hysteresis current controller 利用磁滞电流控制器改善电感电池型五电平CSI的输出电流
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP249-257
S. Suroso, Winasis Winasis, Priswanto Priswanto, Sholikhah Sholikhah
{"title":"Improving output current of inductor-cell based five-level CSI using hysteresis current controller","authors":"S. Suroso, Winasis Winasis, Priswanto Priswanto, Sholikhah Sholikhah","doi":"10.11591/IJPEDS.V12.I1.PP249-257","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP249-257","url":null,"abstract":"Current source inverter (CSI) operates to output a specified ac current waveform from dc current sources. Talking about power quality, harmonics distortion of ac waveform is a problem of an inverter circuit. Generating a multilevel current waveform will have less harmonics content than a traditional three-level current waveform. In addition to non-ideal conditions of power switches, i.e. voltage drop in diodes, conductors or controlled switches, the performance of current controller applied in an inverter circuit will considerably affect the ac waveform quality produced by inverter circuit. This paper presents and discusses application of hysteresis current controller in the five-level H-bridge with inductor-cell current source inverter. The current controller performance was compared with the proportional integral current controller. Some test results are presented and discussed to explore the advantages of hysteresis controller in reducing the current ripple and harmonics distortion of output current.","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"64368403","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study of the operation of the output filter of a single-phase series active power filter 单相串联有源电力滤波器输出滤波器的工作原理研究
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP304-313
M. Antchev, Vanjo Gourgoulitsov, H. Antchev
{"title":"Study of the operation of the output filter of a single-phase series active power filter","authors":"M. Antchev, Vanjo Gourgoulitsov, H. Antchev","doi":"10.11591/IJPEDS.V12.I1.PP304-313","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP304-313","url":null,"abstract":"In the article is presented a single-phase series active power filter (SFSAPF) designed to compensate the total harmonic distortion (THD) factor of the supply network voltage. Particular attention is paid to the work of the output capacitor of the passive filter, and dependencies for the design of the filter at hysteresis voltage control are presented. The value of the higher harmonics of the current through the filter capacitor is determined. A mathematical relationship between the voltage ripple of the capacitor, its value and the switching frequency is derived. As a result of the advanced research a methodology for designing the output filter of a single-phase serial active power filter has been proposed. The results from computer simulation and experiment are also given.","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"12 1","pages":"304-313"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"64368471","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Finite frequency H∞control design for nonlinear systems 非线性系统的有限频率H∞控制设计
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP567-575
Zineb Lahlou, A. El‐Amrani, I. Boumhidi
{"title":"Finite frequency H∞control design for nonlinear systems","authors":"Zineb Lahlou, A. El‐Amrani, I. Boumhidi","doi":"10.11591/IJPEDS.V12.I1.PP567-575","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP567-575","url":null,"abstract":"The work deals finite frequency H ∞ control design for continuous time nonlinear systems, we provide sufficient conditions, ensuring that the closed-loop model is stable. Simulations will be gifted to show level of attenuation that a H ∞ lower can be by our method obtained developed where further comparison.","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"12 1","pages":"567-575"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46295828","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Current mode control of single phase grid tie inverter with anti-islanding 抗孤岛单相并网逆变器的电流模式控制
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP241-248
S. Lakshminarayanan, Kiran Kumar B M, S. N. Rao, P. S.
{"title":"Current mode control of single phase grid tie inverter with anti-islanding","authors":"S. Lakshminarayanan, Kiran Kumar B M, S. N. Rao, P. S.","doi":"10.11591/IJPEDS.V12.I1.PP241-248","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP241-248","url":null,"abstract":"The aim of this paper is to explore the use of various current mode control (CMC) techniques to design a single phase grid tie inverter integrated with anti-islanding protection. Three types of CMC techniques have been discussed, namely current hysteresis control (CHC), constant frequency control (CFC) and average current mode control (ACMC). The performance of the grid tie inverter in the event of grid voltage failure is also studied to help install an anti-islanding mechanism. The proposed control techniques shall eliminate the use of Phase locked loop (PLL) control as the current reference is generated from the grid voltage itself. All three current mode control techniques of an inverter have been simulated in MATLAB/Simulink to evaluate the performance of the designed inverter. The simulated results show a current THD of less than 5% in all three methods and a good anti-islanding response.","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"12 1","pages":"241-248"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46019959","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Performance analysis of 30 MW wind power plant in an operation mode in Nouakchott, Mauritania 毛里塔尼亚努瓦克肖特30MW风电场运行模式下的性能分析
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP532-541
Bamba Heiba, A. Yahya, M. Taha, Nadhira Khezam, A. Mahmoud
{"title":"Performance analysis of 30 MW wind power plant in an operation mode in Nouakchott, Mauritania","authors":"Bamba Heiba, A. Yahya, M. Taha, Nadhira Khezam, A. Mahmoud","doi":"10.11591/IJPEDS.V12.I1.PP532-541","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP532-541","url":null,"abstract":"In this paper, the performance analysis of a 30 MW wind power plant is performed. The farm consists of fifteen (T1-T15) G9 7/2000/GAMESA 2 MW grid-connected turbines. The farm is in operation mode installed 28 km south of Nouakchott city in Mauritania. The analyzed data are monitored from July 1st, 2015 (the first operation day of the power plant) to December 31st, 2019. The parameters of performance evaluation are power generation, capacity factor, machine availability, grid availability, and system availability. It is observed from data analysis, the wind farm supplies a total energy of 507.39 GWh to the power grid and have a high average capacity factor of 42.55%. T1 produces the highest amount of electrical energy among the other turbines with a total energy output of 35.46 GWh, an average capacity factor of 44.97%, and operating hours of 33,814 hours. While T12 produced the minimum amount of energy in this period, the difference in energy compared to T1 is 4.563 GWh. It is observed that the availability of the network is unstable and needs improvement, varying between 90.86% in 2016 and 93.16% in 2018. In the first year of operation, 97.06% of the turbines were available. However, the average availability of the wind farm is approximately 94% during the total study period.","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"12 1","pages":"532-541"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45431682","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Augmented robust T-S fuzzy control based PMSG wind turbine improved with H∞ performance 基于增强鲁棒T-S模糊控制的PMSG风力机H∞性能改进
International Journal of Power Electronics and Drive Systems Pub Date : 2021-03-01 DOI: 10.11591/IJPEDS.V12.I1.PP585-596
Naoual Tidjani, A. Guessoum
{"title":"Augmented robust T-S fuzzy control based PMSG wind turbine improved with H∞ performance","authors":"Naoual Tidjani, A. Guessoum","doi":"10.11591/IJPEDS.V12.I1.PP585-596","DOIUrl":"https://doi.org/10.11591/IJPEDS.V12.I1.PP585-596","url":null,"abstract":"In this paper, an improved augmented Takagi-Sugeno fuzzy control design applied to the system of converting wind turbine energy was proposed. The wind generator used is based on a permanent magnet synchronous wind power generator (PMSG) under varying operation of the wind speed. The proposed T-S fuzzy control strategy aims to maximize wind energy in low wind speed. A part of our contribution lies in the limitation of the power output of the wind generator in high wind speed. Through the concept of the virtual desired variables, the design of the output tracking controller is achieved. In light of this concept, the developed T-S fuzzy control was designed via parallel-distributed compensation (PDC) approach with H ∞ performance. Sufficient conditions for the stability of the closed-loop system affected by external disturbances are proved from Lyapunov’s direct method and the feedback gains of the controller strategy are determined by linear matrix inequalities (LMIs) tools. Another contribution is in showing the robustness of the Takagi-Sugeno based control strategy, with a focus on a set of system parameters with model uncertainties. The simulation results show the high performance of the proposed controller strategy for a 5MW (PMSG) obtained through simulation.","PeriodicalId":38280,"journal":{"name":"International Journal of Power Electronics and Drive Systems","volume":"12 1","pages":"585-596"},"PeriodicalIF":0.0,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45169556","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信