Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference最新文献

筛选
英文 中文
Power Quality Park - Idea and feasibility study 电能质量园区——构想与可行性研究
G. Błajszczak, P. Antos
{"title":"Power Quality Park - Idea and feasibility study","authors":"G. Błajszczak, P. Antos","doi":"10.1109/PQ.2010.5550026","DOIUrl":"https://doi.org/10.1109/PQ.2010.5550026","url":null,"abstract":"A new industrial area will be established in the north of Poland. This area is dedicated to factories and businesses that require extremely high quality of power supply. For this reason it is called the “Power Quality Park”. This paper describes important designing and organizational aspects of ensuring necessary level of power quality. The project is implemented by a group of companies including the Polish transmission system operator and the owner of Polish transmission network: PSE Operator S.A.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114802702","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Tariffs for reactive power supplied from distribution networks 配电网无功供电电价
M. Loonurm, P. Raesaar, E. Tiigimagi
{"title":"Tariffs for reactive power supplied from distribution networks","authors":"M. Loonurm, P. Raesaar, E. Tiigimagi","doi":"10.1109/PQ.2010.5550024","DOIUrl":"https://doi.org/10.1109/PQ.2010.5550024","url":null,"abstract":"This paper disserts the reactive power pricing for customers of distribution utility which provides sufficient revenue for reactive power transfer service and encourage customers compensate reactive power adequately. The price for reactive energy supplied from a distribution network is expressed as sum of the price of it supplied by the transmission network and the price of reactive power transfer service by the distribution network. The profit margin, the excise on electricity and VAT will be added. A practical methodology of calculating the variable and fixed components of the reactive power transfer service price under uncertainty is presented. The structures of tariffs on medium and low voltage levels are assessed.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"111 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124103680","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Matrix frequency converter conducted and radiated emissions 矩阵变频器传导和辐射发射
G. Asmanis, L. Ribickis, V. Novikovs, A. Ruško
{"title":"Matrix frequency converter conducted and radiated emissions","authors":"G. Asmanis, L. Ribickis, V. Novikovs, A. Ruško","doi":"10.1109/PQ.2010.5550008","DOIUrl":"https://doi.org/10.1109/PQ.2010.5550008","url":null,"abstract":"Matrix converter inherently exhibits sinusoidal input current waveforms and has less stressful output voltage waveforms, but it is causing problems with conducted and radiated emissions. This paper deals with matrix converter emitted disturbances from point of view of electromagnetic compatibility (EMC) standard EN61800-3 and allocates the sources of undesirable emissions.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115832072","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Overvoltage spikes transmitted through distribution transformers due to MV spark-gap operation 由于中压火花隙操作而通过配电变压器传输的过电压尖峰
N. Sabiha, M. Lehtonen
{"title":"Overvoltage spikes transmitted through distribution transformers due to MV spark-gap operation","authors":"N. Sabiha, M. Lehtonen","doi":"10.1109/PQ.2010.5549996","DOIUrl":"https://doi.org/10.1109/PQ.2010.5549996","url":null,"abstract":"Small distribution transformers are often protected with spark gaps. As the spark-gap ignites, an overvoltage is coupled to the secondary side due to the steep voltage change. This overvoltage can reach to the customer socket. In this paper, the breakdown of MV spark-gaps is first modeled under an impulse voltage superimposed on AC voltage. To study the overvoltage propagation to the low voltage side, an accurate and simplified high frequency transformer model is used. The model, MV spark-gap and LV network are combined in ATP/EMTP to study the overvoltage spike propagation. Finally, the low voltage surge arrester at the secondary terminals of the distribution transformer is investigated for overvoltage mitigation.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"123 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129536512","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Experimental investigations and calculations in 6–35 kV networks with various neutral conditions 6 - 35kv各种中性点条件下网络的实验研究与计算
A. Shirkovets, A. Vasilyeva, A. Telegin
{"title":"Experimental investigations and calculations in 6–35 kV networks with various neutral conditions","authors":"A. Shirkovets, A. Vasilyeva, A. Telegin","doi":"10.1109/PQ.2010.5549997","DOIUrl":"https://doi.org/10.1109/PQ.2010.5549997","url":null,"abstract":"Resonant grounded or ungrounded neutral system produces specific overvoltages, e.g. overvoltages at single line-to-ground arcing faults. Theoretical research and field experience show that reducing overvoltage levels at arcing ground faults and decreasing the number of ground faults without increasing of ground-fault currents can be reached by connecting the neutral of the transformer to ground through a high-value resistor. Determination of real capacitance current value in 6-35 kV network is urgent and needs accurate solution.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125774900","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Customer-based reliability monitoring criteria for finnish distribution companies 芬兰配电公司基于客户的可靠性监控标准
J. Lassila, T. Kaipia, J. Haakana, J. Partanen
{"title":"Customer-based reliability monitoring criteria for finnish distribution companies","authors":"J. Lassila, T. Kaipia, J. Haakana, J. Partanen","doi":"10.1109/PQ.2010.5550001","DOIUrl":"https://doi.org/10.1109/PQ.2010.5550001","url":null,"abstract":"In Finland, new reliability criteria for electricity distribution companies have been analysed, and now, the implementation of the criteria is being discussed. The criteria cover the customer-based cumulative sum of durations of long interruptions and the cumulative number of short interruptions. The criteria are established by the Finnish Energy Industries (ET) together with electricity distribution companies and technical universities.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127550382","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Energy saving effect due to the voltage reduction in industrial electrical networks 工业电网电压降低的节能效果
A. Novitskiy, H. Schau
{"title":"Energy saving effect due to the voltage reduction in industrial electrical networks","authors":"A. Novitskiy, H. Schau","doi":"10.1109/PQ.2010.5550018","DOIUrl":"https://doi.org/10.1109/PQ.2010.5550018","url":null,"abstract":"The power consumption is depending on the voltage level at the load bus. For many enterprises, especially for the enterprises making small series of various products the production conditions and, respectively, the power consumption by different consumers can be significantly different from day to day. It is difficult to assess the real effect of optimizing the voltage level over a short-time. The method of the express-estimation of the power reduction effect caused by the reducing of the voltage level is discussed in the paper. A row of LV networks were investigated with the purpose to develop and to verify practical measures for the reduction of power consumption without affecting the production processes in the enterprises. The practical results of the carried out voltage optimization are discussed in the paper.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"248 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121428803","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
The generation of symmetrical space phasors compared with the selective harmonic elimination method of multilevel converters 对称空间相量的产生与多电平变换器的选择性谐波消除方法的比较
G. Mehlmann, G. Herold
{"title":"The generation of symmetrical space phasors compared with the selective harmonic elimination method of multilevel converters","authors":"G. Mehlmann, G. Herold","doi":"10.1109/PQ.2010.5550007","DOIUrl":"https://doi.org/10.1109/PQ.2010.5550007","url":null,"abstract":"The basic concept of a multilevel converter is to synthesize a staircase voltage wave-form by the use of several lower voltage DC sources. Capacitors, batteries, fuel cells and photovoltaic modules can be used as DC sources. A multilevel converter has several advantages, like a high voltage quality and low electromagnetic compatibility problems. Two different modulation schemes for multilevel inverters will be analyzed and compared in this paper: The well known selective harmonic elimination method and the generation of highly pulsating space phasors.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130986115","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Mobile earth fault localization by tracing current injection 电流注入跟踪法定位活动接地故障
C. Raunig, L. Fickert, C. Obkircher, G. Achleitner
{"title":"Mobile earth fault localization by tracing current injection","authors":"C. Raunig, L. Fickert, C. Obkircher, G. Achleitner","doi":"10.1109/PQ.2010.5549991","DOIUrl":"https://doi.org/10.1109/PQ.2010.5549991","url":null,"abstract":"In this paper the authors present an interesting method for mobile earth fault localization in resonant grounded grids. The method is based on an additional current injection with a non-grid-frequency current and detection with magnetic-field sensors in close vicinity of the line. The advantage of the presented method is that a mobile earth fault localization-unit for the operation personal is provided. Especially in medium voltage grids this method provides an interesting method for earth fault localization.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121171937","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Residential electricity consumption and loads pattern analysis 居民用电负荷模式分析
A. Rosin, H. Hoimoja, T. Moller, M. Lehtla
{"title":"Residential electricity consumption and loads pattern analysis","authors":"A. Rosin, H. Hoimoja, T. Moller, M. Lehtla","doi":"10.1109/PQ.2010.5550009","DOIUrl":"https://doi.org/10.1109/PQ.2010.5550009","url":null,"abstract":"This article analyses household electricity consumption in Estonia. Energy consumption of workday and holiday by loads is discussed. The final part describes the evaluation of feasibility of common investments","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122859884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 24
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信