{"title":"Mobile earth fault localization by tracing current injection","authors":"C. Raunig, L. Fickert, C. Obkircher, G. Achleitner","doi":"10.1109/PQ.2010.5549991","DOIUrl":null,"url":null,"abstract":"In this paper the authors present an interesting method for mobile earth fault localization in resonant grounded grids. The method is based on an additional current injection with a non-grid-frequency current and detection with magnetic-field sensors in close vicinity of the line. The advantage of the presented method is that a mobile earth fault localization-unit for the operation personal is provided. Especially in medium voltage grids this method provides an interesting method for earth fault localization.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQ.2010.5549991","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

In this paper the authors present an interesting method for mobile earth fault localization in resonant grounded grids. The method is based on an additional current injection with a non-grid-frequency current and detection with magnetic-field sensors in close vicinity of the line. The advantage of the presented method is that a mobile earth fault localization-unit for the operation personal is provided. Especially in medium voltage grids this method provides an interesting method for earth fault localization.
电流注入跟踪法定位活动接地故障
本文提出了一种在谐振接地网中进行活动接地故障定位的方法。该方法基于非电网频率电流的额外电流注入,并在线路附近使用磁场传感器进行检测。该方法的优点是为操作人员提供了移动式接地故障定位装置。特别是在中压电网中,该方法为接地故障定位提供了一种有趣的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信