A. Rodionov, D.N. Popov, A. S. Sosnin, A. Mokeev, A. Popov
{"title":"Extending Functionality and Application Scope of Synchronised Phasor Measurement Technology","authors":"A. Rodionov, D.N. Popov, A. S. Sosnin, A. Mokeev, A. Popov","doi":"10.1109/RPA.2018.8537229","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537229","url":null,"abstract":"Applied in WAMS, phasor measurement units (PMU) have proved their effectiveness in increasing distributed power systems reliability. In recent years, devices performing synchrophasor measurements have found application in various systems serving to increase reliability and efficiency of power systems, e.g. by means of improving the quality of system state estimation [1]–[4]. Wide Area Control Systems (WACS), Wide Area Protection Systems (WAPS), Wide Area Monitoring, Protection And Control Systems (WAMP ACS) are some promising fields of application for this class of devices.","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"102 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117297812","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Power Systems State Estimation Acceleration on the Basis of the Synchronized Phasor Measurements in the Power System Steady State Control Tasks","authors":"P. Bartolomey, S. Semenenko","doi":"10.1109/RPA.2018.8537205","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537205","url":null,"abstract":"In most of the world's energy systems, in recent years there has been a widespread introduction of synchronized phasor measurements (SPM). They allow both to obtain measurements of the traditional parameters of the established mode (voltage $V$ and current $I$ modules, active $P$ and reactive $Q$ power) with a time stamp, and to measure new parameters, namely, the phase angles of voltage δ and current $varphi$. The focus on SPM in dispatching and emergency control systems is due to a number of factors, the most important of which is a sharp increase in the accuracy of measurements, since measurement non-synchronism is the main source of error in telemetry (TM).","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129826696","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research of the Possibility of Using Synchronized Vector Meter for the Realization of Automatic Reclouser","authors":"D. Stepanov, T. Klimova","doi":"10.1109/RPA.2018.8537226","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537226","url":null,"abstract":"For today one of the actual problems of modern electric power industry are the optimal moments of switching on the line under voltage with automatic reclouser (hereinafter - AR), leading to excessively higher values of current, voltage and network frequency parameters. The main task is still to take into account the transient processes and the characteristic features of the network section during commutations in the automatic reclosure process.","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"105 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124036020","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Method of Creating Diagnostic Stands for Monitoring and Control Tools Using Software and Hardware Modeling","authors":"S. Popov, P.S. Vorona, Gushin M.V","doi":"10.1109/RPA.2018.8537200","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537200","url":null,"abstract":"Software and hardware research technologies are increasingly used in practice and further improvement of research and diagnostic complexes [1]–[3] are precisely associated with them. The combination of digital and analogue and analog-to-digital converters of virtual and physical modeling with the inclusion of real devices in the test circuits (Fig. 1) provides a number of new advantages, for example, automation of testing of relay protection devices, the creation of training simulators for personnel training, testing of flexible controls and regulation under conditions as close to real as possible, etc.","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122959643","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development and Implementation of Distribution Grid Control Automation Algorithms","authors":"D. Bliznyuk","doi":"10.1109/RPA.2018.8537215","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537215","url":null,"abstract":"Reliability of electric power supply to consumers depends on reliability of distribution grids. Phase-to-phase faults (PPF) and line-to-ground faults (LGF), which occur at elements of the 6–20 kV distribution grid, may lead to a temporary loss of loads. Complete restoration of power supply is possible only after the response actions by the field service team (FST). Team personnel need a considerable amount of time (30–80 min) to isolate the fault by performing local sequential switchovers at several substations.","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132845313","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V.D. Lebcdev, A. Yablokov, G. Filatova, N. Lebedeva
{"title":"Specific Features of Digital Current and Voltage Transformers for Relay Protection, Automation and Commercial Electric Power Metering","authors":"V.D. Lebcdev, A. Yablokov, G. Filatova, N. Lebedeva","doi":"10.1109/RPA.2018.8537187","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537187","url":null,"abstract":"At present, active work is under way to develop and introduce digital substations based on modern micro-processing control and relay modules with digital current and voltage instrument (optical) transformers [1]–[3]. Leading relay protection manufacturers have already successfully developed and launched production of microprocessor relay protection modules adapted to work with digital flows, using process buses according to Standard 61850-9-2LE. A somewhat more complicated task is the implementation of current and voltage instrument transformers. The simplest form is to use standard current and voltage transformers provided with measuring merging devices (Stand Alone Merging Units). This approach, however, does not fully resolve the problems of standard current and voltage transformers, such as core saturation. Because of their high price, the use of optical transformers is warranted only at voltages exceeding 110–220 kV. Using digital (unconventional) transformers opens the possibility of operating them in a wide voltage range, from 6 to 220 kV.","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"33 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132811318","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Need for a Digital Substation During The Digitalization of Energy","authors":"A. Gibadullin, V. Pulyaeva, Y. V. Yerygin","doi":"10.1109/RPA.2018.8537223","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537223","url":null,"abstract":"Energy is a branch of the national economy, which in modern times plays an important role in the life of society and man, and serves as the main element of the country's economy. Today, there is a trend of falling technical and economic indicators of the industry. So, the level of depreciation of fixed assets is increasing, fuel consumption in energy production is increasing, there are no effective capacity upgrading programs, etc. There are 321 thermal power plants, 75 hydroelectric power stations, 10 nuclear power plants, 23 solar and 27 wind power stations that produce electricity in the territory of the Russian Federation. Also there are 14 interregional network organization, 29 independent and 3683 territorial grid companies. In this regard, the most relevant is to consider the technical characteristics of power equipment of electric power enterprises.","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124798190","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Perspectives for the Further Development of Monitoring System for System Regulators","authors":"F. N. Gaidamakin, R.P. Teploukhov, R. Kadyrov","doi":"10.1109/RPA.2018.8537194","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537194","url":null,"abstract":"Automatic WAMS Information and Data Acquisition and Processing System operates in «SO UPS» since 2009. Synchronized phasor measurements (SPM), collected by this system, find their application in the tasks of operational dispatching management.","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122056696","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Improving the Accuracy Mathematical Modeling of Transients Emergency Mode Industrial Facilities Distributed Generation","authors":"A. Sokolov, O. Gazizova","doi":"10.1109/RPA.2018.8537190","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537190","url":null,"abstract":"Currently, one of the main trends in the development of industrial power in order to improve power supply reliability and reduce the cost of production is the expansion of large industrial enterprises own sources of distributed generation. Thus a characteristic feature of this process is a significant complication of the configuration of electrical networks, small electric generators distance from the variable load commensurate power sources and power receivers and in some cases - big distance sources distributed electrical generation and bus connection to the power grid. Simultaneously, there is a qualitative change in the composition of energy sources. In the past decade, the industrial powerhouse is basically heat and power plant with turbo-generators with a steam turbine inertia. At the present time there is an intensive introduction of low inertia turbine and gas piston plants. This has a significant impact on the quality of the transition process.","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134273924","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Kupchinov, A. V. Ovechkin, N. Smotrov, Y. Monakov
{"title":"The Application of Supercapacitors for Limitation of Switching Overvoltage in dc Auxiliary Installations of Power Plants and Substations","authors":"A. Kupchinov, A. V. Ovechkin, N. Smotrov, Y. Monakov","doi":"10.1109/RPA.2018.8537195","DOIUrl":"https://doi.org/10.1109/RPA.2018.8537195","url":null,"abstract":"The operation experience of DC auxiliary installations in power plants and substations testifies about periodically occurred failures, [1], [2]. According to statistics, [3], 70% of failures of relay protection operation occur as a result of overvoltage caused by: working of lightning rod, and internal switching in DC circuits, for example, short circuit clearing or switching of circuit breakers electromagnetic drives or DC motors. Previously, relay protection based on electromechanical relays and pole-to-pole overvoltage didn't cause such negative effects. With implementation of microprocessor technics, more sensitive to overvoltage, risk of failures and false tripping of relay protection and supervisory control devices in power plants and substations [4], [5] grew significantly.","PeriodicalId":345204,"journal":{"name":"2018 International Youth Scientific and Technical Conference Relay Protection and Automation (RPA)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115541153","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}