2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)最新文献

筛选
英文 中文
3D printed antennas for Mm-wave sensing applications 用于毫米波传感应用的3D打印天线
A. Vorobyov, J. Farserotu, J. Decotignie
{"title":"3D printed antennas for Mm-wave sensing applications","authors":"A. Vorobyov, J. Farserotu, J. Decotignie","doi":"10.1109/ISMICT.2017.7891759","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891759","url":null,"abstract":"This paper presents three low cost 3D printed antenna concepts for integration with a miniature mm-wave platform. The proposed solutions are optimized to operate in mm-wave ISM band (122GHz-123GHz). Different, inexpensive, detachable antennas can be used with the same platform for various RF sensing applications such as food safety, health and industrial.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123518592","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
A MAC protocol with slot prediction algorithm for wireless body area network 一种带槽预测算法的无线体域网络MAC协议
Toshikuni Miyazaki, Tomohiro Fukuya, R. Kohno
{"title":"A MAC protocol with slot prediction algorithm for wireless body area network","authors":"Toshikuni Miyazaki, Tomohiro Fukuya, R. Kohno","doi":"10.1109/ISMICT.2017.7891756","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891756","url":null,"abstract":"In this paper, we design a Medium Access Control (MAC) protocol for Wireless Body Area Network (WBAN) to allocate slot to packets of each medical and non-medical node. Although a hybrid MAC protocol is defined in IEEE 802.15.6 as the international standard of WBAN, the detail specification depends on the implementation. It is important to consider the Quality of Service (QoS) requirements of each node and packet in WBAN, because different sensor nodes generate time varying packets which generate depending on human behavior. Besides, permissible delay time of each medical and non-medical node is different. To improve both priority control for QoS and dependability, we propose a MAC protocol with slot prediction algorithm. Simulation results show that our protocol outperforms IEEE 802.15.6 in terms of transmission success rate and worst delay time.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124091680","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Variation of impedance in transmission channel of human body communication 人体通信传输通道阻抗的变化
N. Arai, K. Sasaki, D. Muramatsu, Y. Nishida
{"title":"Variation of impedance in transmission channel of human body communication","authors":"N. Arai, K. Sasaki, D. Muramatsu, Y. Nishida","doi":"10.1109/ISMICT.2017.7891765","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891765","url":null,"abstract":"Human body communication (HBC) is a wireless communication method that uses human body as part of the transmission medium. It uses electrodes instead of antennas to generate electric field around the human body. This electric field forms capacitive couplings between transmitter, receiver, human body, and surrounding environment. Transmission from a transmitter on user's wrist to an off-body receiver touched by the user was investigated. The human body wearing a transmitter was modeled as a signal source connected to the receiver input. The equivalent output impedance is composed of impedance of the human body and the capacitance of the capacitive coupling that is affected by the surrounding environment and the transmitter arrangement. Equivalent output impedance was estimated by maximizing the received signal power by adjusting input resistance of the receiver and by inserting inductance. Three types of transmitter electrodes and two types of receiver stands (wood and steel) were used to evaluate influences on the equivalent output impedance.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127789701","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Proposal methods for performance analysis of WBANs based on CSMA/CA 提出了基于CSMA/CA的无线宽带性能分析方法
Do Thanh Quan, Pham Thanh Hiep, Takumi Kobayashi, Kento Takabayashi, R. Kohno
{"title":"Proposal methods for performance analysis of WBANs based on CSMA/CA","authors":"Do Thanh Quan, Pham Thanh Hiep, Takumi Kobayashi, Kento Takabayashi, R. Kohno","doi":"10.1109/ISMICT.2017.7891758","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891758","url":null,"abstract":"There have been burning issues on Wireless Body Area Networks (WBANs) in which performance analysis for media access layer (MAC) protocol is essential and has been discussed in many literatures. By using Markov chain model, saturation and non-saturation conditions, many works can calculate access probability and throughput of system. However, previous works usually assumed that channel is ideal and with both saturation and non-saturation conditions effect of remained packets, which were transmitted unsuccessfully due to collision or busy channel, was not considered adequately. The target of this paper is to evaluate system performance more accurately and flexibly, considering channel is non-ideal, taking into account the remained packets and using statistical mathematics instead of saturation and non-saturation condition and then to optimize parameters to achieve higher performance.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121628158","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Integrated electromyography visualization with multi temporal resolution 综合肌电图可视化与多时间分辨率
Pedro Cardoso, N. Datia, Matilde Pato
{"title":"Integrated electromyography visualization with multi temporal resolution","authors":"Pedro Cardoso, N. Datia, Matilde Pato","doi":"10.1109/ISMICT.2017.7891775","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891775","url":null,"abstract":"For the analysis and comparison of electromyography (EMG) signals from different patients, standardization techniques are used to calculate the integrated EMG signal (iEMG), useful to evaluate the level of activity of different muscles. The iEMG corresponds to the area under the rectified curve (AUC). Currently, monitoring and follow-up of these patients is done in regular health exams where the evolution of patients is assessed. The monitoring includes performing multiple clinical trials. The goal of this paper is to help medical staff assessing the evolution of amyotrophic lateral sclerosis (ALS) disease by analyzing the collected data. The signal, described by the electromyogram, can be measured applying conductive elements or electrodes to the skin surface. The electrical activity of skeletal muscles is continuously measured for at least 24 hours. In this work we used an appropriate data model to store data generated by EMGs, optimized for analytical processing. We implemented aWeb API in order to provide access to the model data in an agnostic way, both to database management systems and data consumers. We implemented a web application to visualize data through the use of several interactive charts. Usability testing helped to validate the solution, confirming the ease of use of the web application and the fulfillment of all the proposed goals. The telemonitoring ALS patients doesn't change mortality but reduces the need for hospitalization and costs for patient.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126316244","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Parameter optimization of motion artifact canceling PPG-based heart rate sensor by means of cross validation 基于交叉验证的运动伪影消除ppg心率传感器参数优化
S. Hara, Takunori Shimazaki, H. Okuhata, Hajime Nakamura, Takashi Kawabata, Kai Cai, T. Takubo
{"title":"Parameter optimization of motion artifact canceling PPG-based heart rate sensor by means of cross validation","authors":"S. Hara, Takunori Shimazaki, H. Okuhata, Hajime Nakamura, Takashi Kawabata, Kai Cai, T. Takubo","doi":"10.1109/ISMICT.2017.7891771","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891771","url":null,"abstract":"Photoplethysmography (PPG) is one of the simple and non-invasive heart rate (HR) sensing methods, but when applying it to a person during exercise, the output is contaminated with motion artifact (MA). Furthermore, when the pressure to stabilize the sensor on the skin surface is lower, extremely large values referred to as \"outliers\" are often observed in the sensed heart rate. To cancel the MA and reject the outliers, we have proposed an MA canceling PPG-based HR sensor, and have confirmed its effectivity for persons during vigorous exercises. However, the HR sensor contains several parameters to be adjusted to obtain better performance, although the number of experiments using subjects is limited due to its complexity. In this paper, we discuss a parameter optimization method for the MA canceling PPG-based HR sensor by means of cross validation. We apply the leave-one-out cross validation (LOOCV) to experimental data changing the values of the parameters, and then determine the ones which can minimize the root mean square error (RMSE). Finally, we show that the proposed HR sensor can achieve the RMSE of less than 7.1 beats per minute (bpm) for exercises of walking, running and jumping.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123714817","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Accurate broadband measurement of electromagnetic tissue phantoms using open-ended coaxial systems 使用开放式同轴系统的电磁组织幻象的精确宽带测量
A. Fornés-Leal, C. García-Pardo, N. Cardona, Sergio Castelló-Palacios, A. Vallés-Lluch
{"title":"Accurate broadband measurement of electromagnetic tissue phantoms using open-ended coaxial systems","authors":"A. Fornés-Leal, C. García-Pardo, N. Cardona, Sergio Castelló-Palacios, A. Vallés-Lluch","doi":"10.1109/ISMICT.2017.7891761","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891761","url":null,"abstract":"New technologies and devices for wireless communication networks are continually developed. In order to assess their performance, they have to be tested in realistic environments taking into account the influence of the body in wireless communications. Thus, the development of phantoms, which are synthetic materials that can emulate accurately the electromagnetic behaviour of different tissues, is mandatory. An accurate dielectric measurement of these phantoms requires using a measurement method with a low uncertainty. The openended coaxial technique is the most spread technique but its accuracy is strongly conditioned by the calibration procedure. A typical calibration is performed using an open circuit, a short circuit and water. However, this basic calibration is not the most accurate approach for measuring all kinds of materials. In this paper, an uncertainty analysis of the calibration process of openended coaxial characterization systems when a polar liquid is added to the typical calibration is provided. Measurements are performed on electromagnetically well-known liquids in the 0.5 - 8.5 GHz band. Results show that adding methanol improves the accuracy in the whole solution domain of the system, mainly when measuring phantoms that mimic high water content tissues, whereas ethanol is more suitable for measuring low water content tissue phantoms.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115265554","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
An adaptive scheme of controlling dosage and dosing interval in general anesthesia by model predictive control using anesthetic depth model 一种基于麻醉深度模型的模型预测控制全身麻醉剂量和给药间隔的自适应方案
Yoshitomo Sakuma, Keiko Sameshima, R. Kohno
{"title":"An adaptive scheme of controlling dosage and dosing interval in general anesthesia by model predictive control using anesthetic depth model","authors":"Yoshitomo Sakuma, Keiko Sameshima, R. Kohno","doi":"10.1109/ISMICT.2017.7891772","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891772","url":null,"abstract":"In this paper, we proposed a dosage control system for total intravenous anesthesia (TIVA) in order to help anesthe- siologists and enable to manage multiple operations remotely by one anesthesiologist. In the general anesthesia, constraints of a drug dosage and the value of biological information indicating anesthetic depth must be taken into account. Also, introduction time of anesthesia and time to awake after surgery is required to be short with satisfying above restrictions. Furthermore, if surgery periods are extended, anesthetic effect should be maintained during surgery. From this point of view, we proposed an adaptive scheme of controlling the dosage and the dosing interval by model predictive control in order to satisfy such complicated requirements.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124326648","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Formulas for easy-to-prepare tailored phantoms at 2.4 GHz ISM band 在2.4 GHz ISM波段易于准备的定制幻影的公式
Sergio Castelló-Palacios, A. Vallés-Lluch, C. García-Pardo, A. Fornés-Leal, N. Cardona
{"title":"Formulas for easy-to-prepare tailored phantoms at 2.4 GHz ISM band","authors":"Sergio Castelló-Palacios, A. Vallés-Lluch, C. García-Pardo, A. Fornés-Leal, N. Cardona","doi":"10.1109/ISMICT.2017.7891760","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891760","url":null,"abstract":"Emerging integration of communication networks into wearable or implantable body devices involves a challenge due to the transmitting medium, the body itself. This medium is heterogeneous and lossier than air, so devices that are supposed to work on it should be tested in tissue-equivalent materials. A number of materials with the electromagnetic response of body tissues have been proposed. Most of them are sucrose aqueous solutions that are supposed to simulate human's muscle tissue mainly within medical frequency bands. However, these recipes are restricted to a single tissue and it is difficult to adapt them to fit the permittivity values of different body tissues. The significance of this study lies in the development of a mathematical relationship that models the dielectric properties of an aqueous solution according to the concentration of sugar and salt at 2.4 GHz, the frequency around which an Industrial, Scientific and Medical (ISM) band is placed. Thus, it becomes possible to create custom-made phantoms with simple and accessible ingredients that are easy to prepare in any laboratory.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"121 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127156633","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Received signal in harmonic motion microwave doppler imaging as a function of tumor position in a 3D scheme 在三维方案中,谐波运动微波多普勒成像接收信号作为肿瘤位置的函数
U. Irgin, C. B. Top, A. Tafreshi, N. G. Gencer
{"title":"Received signal in harmonic motion microwave doppler imaging as a function of tumor position in a 3D scheme","authors":"U. Irgin, C. B. Top, A. Tafreshi, N. G. Gencer","doi":"10.1109/ISMICT.2017.7891774","DOIUrl":"https://doi.org/10.1109/ISMICT.2017.7891774","url":null,"abstract":"Harmonic Motion Microwave Doppler Imaging method, which was proposed as an alternative method for breast tumor detection, is a combination of microwave radar and focused ultrasound techniques yielding data depending on electrical and mechanical properties of the tissue. In this study, Harmonic Motion Microwave Doppler Imaging data from a small tumor inside homogeneous fat is analyzed as a function of tumor location on three orthogonal planes using Finite Difference Time Domain simulations. The results show that the resolution on the order of millimeters is achievable with this method.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133359609","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信