{"title":"在三维方案中,谐波运动微波多普勒成像接收信号作为肿瘤位置的函数","authors":"U. Irgin, C. B. Top, A. Tafreshi, N. G. Gencer","doi":"10.1109/ISMICT.2017.7891774","DOIUrl":null,"url":null,"abstract":"Harmonic Motion Microwave Doppler Imaging method, which was proposed as an alternative method for breast tumor detection, is a combination of microwave radar and focused ultrasound techniques yielding data depending on electrical and mechanical properties of the tissue. In this study, Harmonic Motion Microwave Doppler Imaging data from a small tumor inside homogeneous fat is analyzed as a function of tumor location on three orthogonal planes using Finite Difference Time Domain simulations. The results show that the resolution on the order of millimeters is achievable with this method.","PeriodicalId":333786,"journal":{"name":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Received signal in harmonic motion microwave doppler imaging as a function of tumor position in a 3D scheme\",\"authors\":\"U. Irgin, C. B. Top, A. Tafreshi, N. G. Gencer\",\"doi\":\"10.1109/ISMICT.2017.7891774\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Harmonic Motion Microwave Doppler Imaging method, which was proposed as an alternative method for breast tumor detection, is a combination of microwave radar and focused ultrasound techniques yielding data depending on electrical and mechanical properties of the tissue. In this study, Harmonic Motion Microwave Doppler Imaging data from a small tumor inside homogeneous fat is analyzed as a function of tumor location on three orthogonal planes using Finite Difference Time Domain simulations. The results show that the resolution on the order of millimeters is achievable with this method.\",\"PeriodicalId\":333786,\"journal\":{\"name\":\"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)\",\"volume\":\"71 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISMICT.2017.7891774\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 11th International Symposium on Medical Information and Communication Technology (ISMICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISMICT.2017.7891774","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Received signal in harmonic motion microwave doppler imaging as a function of tumor position in a 3D scheme
Harmonic Motion Microwave Doppler Imaging method, which was proposed as an alternative method for breast tumor detection, is a combination of microwave radar and focused ultrasound techniques yielding data depending on electrical and mechanical properties of the tissue. In this study, Harmonic Motion Microwave Doppler Imaging data from a small tumor inside homogeneous fat is analyzed as a function of tumor location on three orthogonal planes using Finite Difference Time Domain simulations. The results show that the resolution on the order of millimeters is achievable with this method.