N. Tokuda, M. Furuya, Y. Kikuoko, Y. Tsutui, T. Kumamoto, T. Kanno
{"title":"Development of a redox flow (RF) battery for energy storage","authors":"N. Tokuda, M. Furuya, Y. Kikuoko, Y. Tsutui, T. Kumamoto, T. Kanno","doi":"10.1109/PCC.2002.998133","DOIUrl":"https://doi.org/10.1109/PCC.2002.998133","url":null,"abstract":"The Kansai Electric Power Company has been engaged in the ongoing development of the redox flow battery (RFB) since 1985 in collaboration with Sumitomo Electric Industries, Ltd. The fundamentals and performance of RFB have been verified through field test projects such as the prototype 450 kW 2 h system and the advanced design 168 kW 8 h system installed in Tatsumi substation. Now RFB has total energy efficiency of more than 70% including inverter loss, etc., and RFB has been applied to a number of practical uses. Several RFB systems have been installed in a semiconductor factory (3000 kW for UPS), a university (500 kW for load leveling), and other locations.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124473364","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A method of circuit design based on the experimental analysis of high-intensity ultrasonic transducer and the numerical analysis of zero current soft switching inverter using current overlapping commutation","authors":"H. Kifune, Y. Hatanaka","doi":"10.1109/PCC.2002.998194","DOIUrl":"https://doi.org/10.1109/PCC.2002.998194","url":null,"abstract":"This paper describes the electrical characteristics of an ultrasonic transducer through the results of experiments from the point of view of driving by inverter. In order to realize ZCS operation of the inverter, the characteristics of inverter are calculated using normalized numerical analysis. Optimized circuit design based on the experimental and numerical analyses is presented with consideration of switching stresses.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126354545","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A new clew for research on PWM methods of multilevel inverters: principle and applications","authors":"Hongyang Wu, Yan Deng, Y. Liu, Xiangning He","doi":"10.1109/PCC.2002.998152","DOIUrl":"https://doi.org/10.1109/PCC.2002.998152","url":null,"abstract":"A novel clew for the research on carrier-based PWM methods of multilevel inverters is proposed in the paper, which is based on the concept Of combination of the control freedom degrees (CFD). As a typical application of the clew, a novel phase shift switching frequency optimum PWM (PS-SFO PWM) method is presented. Furthermore, the correlation between multilevel carrier-based PWM methods and space vector PWM (SVPWM) methods is established by theoretical analysis, by which the research on multilevel PWM methods can be included in the clew of the combination of CFD. From the clew, a simplified algorithm of SKPWM method for five-level cascade multilevel inverters is presented, which is equivalent to PS-SFO-PWM method. The correctness and the guiding significance of the proposed research clew for the research on multilevel PWM techniques is verified by the corresponding simulation results.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128125073","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Experimental verification of line current detection type active filter combined with disturbance-observer","authors":"S. Hamasaki, A. Kawamura","doi":"10.1109/PCC.2002.998543","DOIUrl":"https://doi.org/10.1109/PCC.2002.998543","url":null,"abstract":"In this paper, we proposed a new control method for the AF to improve the harmonics compensation performance, in which the proposed control law is realized by the deadbeat control The disturbance observer is introduced to improve the harmonics compensation performance. By the estimation of the harmonics using the proposed disturbance observer, the compensation characteristics of the AF is very much improved. The deadbeat control can provide good current regulation without the calculation time delay. The current control is achieved by controlling the intermediate voltage of the inverter output filter so that the AF output current is regulated and the pulse width of the PWM inverter is determined by the deadbeat control law. The disturbance observer is effectively and stably realized by the proposed current regulation. As a result, the total harmonics compensation characteristics is much improved. The control method, mathematical analysis and the experimental results are presented in this paper.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128131428","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Novel control for redundant parallel UPSs with instantaneous current sharing","authors":"Y. Xing, Lipei Huang, S. Sun, Yangguang Yan","doi":"10.1109/PCC.2002.998098","DOIUrl":"https://doi.org/10.1109/PCC.2002.998098","url":null,"abstract":"A novel distributed control scheme for redundant parallel UPS with instantaneous current sharing is proposed. Current sharing based upon average current method is realized through the share bus interconnecting all the paralleled modules without extra control modules. The share bus consists of only three automatically averaged signals (no matter how many modules in parallel): inverter reference, sensed load current and feedback voltage. Current sharing control is decoupled from reference synchronization control through local feedback of the averaged reference so that inertia of the system reduced greatly. As a result a fast dynamic response and an equal load current sharing capability is ensured, under linear or nonlinear load. System configuration and operation principle are presented while simulation and experiment results are given in detail.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132351030","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Toyokazu Hamajima, Masaru Hasegawa, S. Doki, Shigeru Okuma
{"title":"Sensorless vector control of induction motor with stator resistance identification based on augmented error","authors":"Toyokazu Hamajima, Masaru Hasegawa, S. Doki, Shigeru Okuma","doi":"10.1109/PCC.2002.997569","DOIUrl":"https://doi.org/10.1109/PCC.2002.997569","url":null,"abstract":"This paper proposes a speed sensorless vector control system of induction motors which is stable in regenerating region as well as motoring one. In speed sensorless vector controls of induction motors with adaptive observers, the speed identification system becomes unstable for the major part of the regenerating region. Moreover, it is pointed out that the stator resistance variation influences the speed identification. Thus, it is necessary to find an adaptive scheme which can stabilize the identification system in whole region. Although several methods have been proposed to stabilize the identification system, they discuss only on the design of the observer gain. In these cases, the following problems exist.. The design parameter is determined by trial and error. Resulting observer gain tends to violate stability of the observer. The induction motor is assumed to be at steady state. Therefore, the stabilization of the parameter identification should be improved by designs of identification laws. In this paper, to stabilize the identification system of the speed and the stator resistance, the augmented error is introduced, yielding the transfer function of an error system becomes \"I\". Next, an adaptive scheme for the speed and the stator resistance is proposed which stabilizes the identification system. Furthermore, the proposed adaptive scheme is simplified to reduce the amount of calculation. Finally, effectiveness of the proposed method is shown by experiments.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130245235","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Koh, Hyun-Woo Lee, K. Suh, K. Takashi, K. Taniguchi
{"title":"The power factor control system of photovoltaic power generation system","authors":"K. Koh, Hyun-Woo Lee, K. Suh, K. Takashi, K. Taniguchi","doi":"10.1109/PCC.2002.997594","DOIUrl":"https://doi.org/10.1109/PCC.2002.997594","url":null,"abstract":"The photovoltaic power generation system has a great future as clean energy instead of fossil fuel, which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using dq transformation. The proposed inverter system provides a sinusoidal AC current for domestic loads and the utility line with unity power factor.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133356215","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Advanced static power converter and control components for TRANSRAPID maglev system","authors":"U. Henning, R. Hoffmann, J. Hochleitner","doi":"10.1109/PCC.2002.998116","DOIUrl":"https://doi.org/10.1109/PCC.2002.998116","url":null,"abstract":"New high power static frequency converter and control system components for the TRANSRAPID propulsion system were developed and successfully tested under realistic operating conditions in the course of modernization of the TRANSRAPID test facility Emsland.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132270313","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Phase synchronization using zero crossing sampling digital phase-locked loop","authors":"S. Pavljasevic, F. Dawson","doi":"10.1109/PCC.2002.997598","DOIUrl":"https://doi.org/10.1109/PCC.2002.997598","url":null,"abstract":"The main objective of this paper is to analyze a zero crossing sampling digital phase-locked loop (PLL) as a building block for a phase synchronization system. To that purpose, the paper deals with modeling, analysis and implementation issues of the PLL. Derived are nonlinear and linear state-space models and a transfer function model. Operation of the PLL is also analyzed using frequency domain methods. An implementation of the PLL using a digital signal processor is described. On the basis of the derived models, two different system controllers are designed and the system transient response for the two cases is compared. The first controller is of a proportional-integral (PI) type and the second controller is minimum response time controller. It is shown how the input signal amplitude variations affect the system transient response. A solution for solving this problem is presented.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134646329","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of the 2/sup nd/ generation SVCS using IEGT","authors":"Masayuki Tobita, Takeo Kanai, Teruo Yoshino","doi":"10.1109/PCC.2002.998128","DOIUrl":"https://doi.org/10.1109/PCC.2002.998128","url":null,"abstract":"A new semiconductor power device, IEGT (injection enhanced gate transistor) has been developed by TOSHIBA Semiconductor Company. It is a metal oxide gate semiconductor device and offers advantages compared with the conventional GTO device, the smaller gate power and the higher turn-on and turn-off capability. A converter using the IEGT has been successfully developed. It will be used in static VAr compensators etc. This paper describes the design, test results and advantages of the developed 21 MVA static VAr compensator using IEGT compared with the GTO converter.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123908501","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}