逆变电源交流驱动的过调制策略

S. Halász, I. Varjasi, A. Zacharov
{"title":"逆变电源交流驱动的过调制策略","authors":"S. Halász, I. Varjasi, A. Zacharov","doi":"10.1109/PCC.2002.998169","DOIUrl":null,"url":null,"abstract":"The three optimized and two carrier-based PWM strategies of the overmodulation region of inverter-fed AC drives are suggested and investigated from the point of view of motor harmonic losses, torque ripples and voltage gain of the control system. The 1/sup st/ optimized solution produces the lowest value of motor harmonic losses if the skin effect in the rotor bar is not significant while the 2/sup nd/ one gives the lowest value of these losses for the strong skin effect. It is shown that the harmonic losses of the optimized and the commonly used carrier based three-phase and two-phase overmodulation strategies ensure acceptable values of harmonic losses even if the skin effect is taken into account but only up to 96% of the maximal possible voltage region. In this case for the presently used switching frequencies the motor harmonic losses rarely exceed the maximal losses of the normal voltage region. The near constant voltage gain can be ensured for the overmodulation region too. The torque ripples of different overmodulation strategies have about the same values.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Overmodulation strategies of inverter-fed AC drives\",\"authors\":\"S. Halász, I. Varjasi, A. Zacharov\",\"doi\":\"10.1109/PCC.2002.998169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The three optimized and two carrier-based PWM strategies of the overmodulation region of inverter-fed AC drives are suggested and investigated from the point of view of motor harmonic losses, torque ripples and voltage gain of the control system. The 1/sup st/ optimized solution produces the lowest value of motor harmonic losses if the skin effect in the rotor bar is not significant while the 2/sup nd/ one gives the lowest value of these losses for the strong skin effect. It is shown that the harmonic losses of the optimized and the commonly used carrier based three-phase and two-phase overmodulation strategies ensure acceptable values of harmonic losses even if the skin effect is taken into account but only up to 96% of the maximal possible voltage region. In this case for the presently used switching frequencies the motor harmonic losses rarely exceed the maximal losses of the normal voltage region. The near constant voltage gain can be ensured for the overmodulation region too. The torque ripples of different overmodulation strategies have about the same values.\",\"PeriodicalId\":320424,\"journal\":{\"name\":\"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCC.2002.998169\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCC.2002.998169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

从电机谐波损耗、转矩脉动和控制系统电压增益的角度出发,提出了三种优化的、两种基于载波的逆变电源交流驱动过调制区PWM策略。当转子条中的趋肤效应不显著时,1/sup /优化方案产生电机谐波损耗的最小值,而当趋肤效应较强时,2/sup /优化方案给出这些损耗的最小值。结果表明,优化后的和常用的基于载波的三相和两相过调制策略的谐波损耗即使考虑趋肤效应,也能保证谐波损耗的可接受值,但只能达到最大可能电压区域的96%。在这种情况下,对于目前使用的开关频率,电机谐波损耗很少超过正常电压区域的最大损耗。在过调制区域也可以保证近恒定的电压增益。不同过调制策略的转矩波纹值基本相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Overmodulation strategies of inverter-fed AC drives
The three optimized and two carrier-based PWM strategies of the overmodulation region of inverter-fed AC drives are suggested and investigated from the point of view of motor harmonic losses, torque ripples and voltage gain of the control system. The 1/sup st/ optimized solution produces the lowest value of motor harmonic losses if the skin effect in the rotor bar is not significant while the 2/sup nd/ one gives the lowest value of these losses for the strong skin effect. It is shown that the harmonic losses of the optimized and the commonly used carrier based three-phase and two-phase overmodulation strategies ensure acceptable values of harmonic losses even if the skin effect is taken into account but only up to 96% of the maximal possible voltage region. In this case for the presently used switching frequencies the motor harmonic losses rarely exceed the maximal losses of the normal voltage region. The near constant voltage gain can be ensured for the overmodulation region too. The torque ripples of different overmodulation strategies have about the same values.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信