Volume 5: Biomedical and Biotechnology最新文献

筛选
英文 中文
A Data-Driven Approach for Estimating Postural Control Using an Inertial Measurement Unit 利用惯性测量单元估计姿态控制的数据驱动方法
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-70518
Anthony Giachin, J. J. Steckenrider, Gregory M Freisinger
{"title":"A Data-Driven Approach for Estimating Postural Control Using an Inertial Measurement Unit","authors":"Anthony Giachin, J. J. Steckenrider, Gregory M Freisinger","doi":"10.1115/imece2021-70518","DOIUrl":"https://doi.org/10.1115/imece2021-70518","url":null,"abstract":"\u0000 In this paper, we propose a probabilistic multi-Gaussian parameter estimation technique which addresses the complex relationship between acceleration and ground force signals used to derive a human’s static center of pressure. The intent of this work is to develop an accurate accelerometer-based method for determining postural control and neuromuscular status which is more portable and cost-effective than force plate-based techniques. Acceleration data was collected using an inertial measurement unit while ground reaction forces were simultaneously measured using a force plate. Various metrics were calculated from both sensors and probabilistic data models were built to characterize the relationships between the two sensors. These models were used to predict force-based postural control metrics corresponding to observed acceleration metrics. Data collected from one participant was used as a training set to which the test data of two individuals were then applied. We conclude that converted acceleration-based metrics on average can accurately predict all the corresponding force-based metrics we studied here. Furthermore, the proposed multi-Gaussian parameter estimation approach outperforms a more basic linear transformation technique for 75% of the metrics studied, as evidenced by an increase in correlation coefficients between true and estimated force plate metrics.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122840408","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Advances in Noninvasive Diagnosis Based on Body Sounds and Vibrations – A Review 基于身体声音和振动的无创诊断研究进展
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-73815
Amirtahà Taebi, F. Khalili
{"title":"Advances in Noninvasive Diagnosis Based on Body Sounds and Vibrations – A Review","authors":"Amirtahà Taebi, F. Khalili","doi":"10.1115/imece2021-73815","DOIUrl":"https://doi.org/10.1115/imece2021-73815","url":null,"abstract":"\u0000 This paper provides a brief overview of the advances in the area of early identification of different types of abnormalities and diseases, including respiratory illnesses and cardiovascular diseases, using noninvasive screening of biomedical acoustic signals. These signals include sounds and vibrations generated by different human body organs and systems that can be measured on the body surface using sensors such as stethoscopes and accelerometers. In this study, the measurement methods and signal processing algorithms for customized feature extraction and classification as well as clinical potentials, current limitations, and future directions are briefly reviewed and discussed.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121347342","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Reliability Check of an Assessment System for Parkinson’s Disease Tremor Monitoring With Portable Devices 便携式帕金森病震颤监测评估系统的可靠性检验
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-71144
Linda Zhu, Nathaniel S. Miller, Charlotte Tang, Sriram Pendyala, Quinn Hanses, Lacie Gladding
{"title":"Reliability Check of an Assessment System for Parkinson’s Disease Tremor Monitoring With Portable Devices","authors":"Linda Zhu, Nathaniel S. Miller, Charlotte Tang, Sriram Pendyala, Quinn Hanses, Lacie Gladding","doi":"10.1115/imece2021-71144","DOIUrl":"https://doi.org/10.1115/imece2021-71144","url":null,"abstract":"\u0000 Tremor, or an involuntary and oscillatory movement of a body part, is a cardinal symptom of Parkinson’s disease (PD) that can significantly impact activities of daily living in people with PD (PwPD). Although tremor can be mitigated with anti-PD medications, medication effectiveness is mixed for PwPD. Therefore, daily monitoring and assessment of tremor are of interest to PwPD, clinicians, and researchers. While several sensors and wearable devices have been developed and introduced to the consumer market, high costs limit their accessibility. The current research is two-fold. First, an assessment system based on multiple algorithms is developed for evaluating the reliability of measurements of PD symptoms: hand tremor and finger/hand movement speed. Second, an Android mobile application was designed and developed to capture finger-tapping frequencies and measurements of several PD symptoms like hand tremor.\u0000 A healthy young adult participant produced a self-generated tremor for this study. The participant held the portable device and conducted self-measurements by following in-app instructions. Resting tremor was measured while the participant rested his upper extremity on the arm of a chair, postural tremor was measured while he maintained a position against gravity, and kinetic tremor was measured during a movement task. Data collection took approximately fifteen minutes. The linear and rotational motions, respectively, were collected by accelerometers and gyroscopes embedded within the mobile device. The results were captured and delivered to a cloud database. An assessment system with multiple algorithms provided a final evaluation of the participant’s tremor. The process included three parts. First, calculation of root-mean-square (RMS) values at all linear and rotational directions was conducted to provide tremor strength. Second, fast Fourier transform (FFT) extracted the peak frequency at each direction. The powers of peaks were compared and the highest peak was defined as the dominant frequency and that frequency’s corresponding direction of motion. Third, hand and motion correlation analysis was used to find any coherence of tremor on 3-D motions. To test the reliability of motion measurement, the same motion input was applied to multiple devices simultaneously. The outputs of different types of mobile devices were evaluated, while considering various factors and models of mobile devices in the market (i.e., device size, weight, operating system, sampling frequency, and accuracy during the measurement). Multiple trials were conducted to test the reliability of the assessment system and the performance of the mobile app. Additionally, the mobile application supports finger tapping tests that measure hand movement speed, which is commonly impaired in PwPD. Both tremor and movement speed measurements can be used to evaluate disease progression over time and could support focused medication adjustments based on symptom data.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131107808","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of an Organisational Framework for the Optimal and Efficient Selection of Actuators 一个组织框架的发展,为最优和有效的选择执行器
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-67744
P. Hanna, Marc G. Carmichael, L. Clemon
{"title":"Development of an Organisational Framework for the Optimal and Efficient Selection of Actuators","authors":"P. Hanna, Marc G. Carmichael, L. Clemon","doi":"10.1115/imece2021-67744","DOIUrl":"https://doi.org/10.1115/imece2021-67744","url":null,"abstract":"\u0000 Actuators are a vital component, and more often than not one of the limiting factors in robotics and robotics related applications. For the use of actuators in robotics related to humanoids, exoskeletons, prosthetics and orthoses, there are more factors that influence the selected actuator than the basic mechanical outputs, size, backlash, material and power consumption. The main interest within these applications is that because the device is being carried by the human user, thus weight, power consumption and form factor are important selection parameters. The correct selection of an actuator for these applications is a difficult and lengthy process to perform. This paper creates an organizational framework and database for searching the wide range of actuators. This dataset is organized into a design tool that plots the properties of each actuator on varying graphs creating trade-off Ashby charts to rapidly narrow the selection space for designers. A case study is performed to demonstrate the use of this design tool in human-centric actuation applications. The database is utilized in the selection of the ideal actuator based on lines of best fit and a multivariate regression analysis for the optimization of parameters about the required specifications. In addition, a meta-analysis identifies clusters of current actuators, gaps for new developments, and trends. This work provides research direction into developing specific actuators to fit into these trend gaps which offers substantial benefits to humanoids, exoskeletons, prosthetics and orthosis.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133648921","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Morphological Markers and Determinants of Left Ventricular Systolic Dysfunction in Repaired Tetralogy of Fallot 修复后法洛四联症左心室收缩功能障碍的形态学标记和决定因素
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-70591
Sachin Govil, Nickolas Forsch, Sara Salehyar, K. Gilbert, Avan Suinesiaputra, S. Hegde, J. Perry, A. Young, J. Omens, A. McCulloch
{"title":"Morphological Markers and Determinants of Left Ventricular Systolic Dysfunction in Repaired Tetralogy of Fallot","authors":"Sachin Govil, Nickolas Forsch, Sara Salehyar, K. Gilbert, Avan Suinesiaputra, S. Hegde, J. Perry, A. Young, J. Omens, A. McCulloch","doi":"10.1115/imece2021-70591","DOIUrl":"https://doi.org/10.1115/imece2021-70591","url":null,"abstract":"\u0000 Patients with repaired tetralogy of Fallot (rTOF) are at risk of long-term left ventricular (LV) dysfunction associated with poor outcomes. In this study, we examined the association of LV end-diastolic (ED) shape with components of systolic wall motion (SWM) that contribute to global systolic dysfunction in an rTOF patient cohort. Features of LV shape associated with conicity and septal wall curvature correlated with components of SWM. The effect of ED shape perturbations on SWM were examined in a finite element analysis of systolic ventricular mechanics. Variations in the combination of ED shape and myocardial contractility were able to match predicted measures of SWM. From these results, we hypothesize that greater LV conicity and a flatter septal wall are markers of reduced global myocardial contractility and should be examined further for clinical prognostic utility to improve patient outcomes.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123277273","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A Comparison of Visco-Hypoelastic and Visco-Hyperelastic Model to Predict the Elastic Strain Energy for Articular Cartilage of Knee Joint 预测膝关节关节软骨弹性应变能的粘-低弹性与粘-超弹性模型比较
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-69494
R. González-Navarrete, A. Vidal-Lesso, Hector PLASCENCIA MORA, Xavier Ulises Huerta-Jacobo
{"title":"A Comparison of Visco-Hypoelastic and Visco-Hyperelastic Model to Predict the Elastic Strain Energy for Articular Cartilage of Knee Joint","authors":"R. González-Navarrete, A. Vidal-Lesso, Hector PLASCENCIA MORA, Xavier Ulises Huerta-Jacobo","doi":"10.1115/imece2021-69494","DOIUrl":"https://doi.org/10.1115/imece2021-69494","url":null,"abstract":"\u0000 The aim of this work is to propose a viscoelastic material model for human cartilage tissue that allows simulating its structural stiffness and elastic strain energy that absorbs per unit volume.\u0000 For this, experimental data reported from flat cylindrical indentation test on human samples of seven patients with unicompartmental osteoarthritis (N = 7) were used. These data allowed the use of one linear model and the adjustment of two non-linear material models, a visco-hypoelastic (VE) and a visco-hyperelastic (VHE) model. The finite element models for the indentation test considered the indenter as a rigid body, the cartilage and subchondral bone as deformable bodies. The indentation force (F, material model structural reaction) and resilience modulus (Er, elastic strain energy per unit volume) were considered as validation parameters.\u0000 The results suggest that largest differences respect to experimental data were found with the linear model (up to 44.33% for Er and 21.75% for F). The best model to reproduce the indentation force was the VHE (mean difference of 3.37±1.03%), while for the elastic strain energy per unit volume, the best model was the VE (mean difference of 16.65±12.74%).","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121715670","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Gait Stability Using Lyapunov Exponents 基于Lyapunov指数的步态稳定性研究
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-73242
J. Galarza, D. Caruntu, S. Vásquez, R. Freeman
{"title":"Gait Stability Using Lyapunov Exponents","authors":"J. Galarza, D. Caruntu, S. Vásquez, R. Freeman","doi":"10.1115/imece2021-73242","DOIUrl":"https://doi.org/10.1115/imece2021-73242","url":null,"abstract":"\u0000 This work deals with the stability of the dynamics of human gait. This is a common exercise. The focus of this investigation is to analyze the knee angle time series and calculate the divergence for over-ground and treadmill walking. Experiments using motion capture technology are used to capture the movement. MATLAB software package is used to calculate the Lyapunov Exponents from the time series. Results are compared with similar studies in the literature. This work provides an insight on the level of stability for treadmill walking. A comparison with stability of normal gait might give an insight on how the treadmill can facilitate rehabilitation using gait.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127448652","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Modeling the Biomechanics Parameters on Achilles Tendon Using OpenSim Simulations and Validating the Sensor Accuracy 基于OpenSim模拟跟腱生物力学参数并验证传感器精度
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-72108
Muhammad Salman, Zachary Contois, M. H. Tanveer
{"title":"Modeling the Biomechanics Parameters on Achilles Tendon Using OpenSim Simulations and Validating the Sensor Accuracy","authors":"Muhammad Salman, Zachary Contois, M. H. Tanveer","doi":"10.1115/imece2021-72108","DOIUrl":"https://doi.org/10.1115/imece2021-72108","url":null,"abstract":"\u0000 OpenSim is a free software platform that enables the user to preform interaction and movement simulations with human, animal, and robotic models. The software is accompanied by a vast user database of simulations and models which is available on the online community. By utilizing the resources available an accurate model can be created to represent any musculoskeletal configuration that happens in day-to-day activities. Forces and moments are calculated experimentally and verified by the OpenSim models for the Achilles Tendon. In this study, the muscle actuation of the Achilles Tendon is collected from multiple subjects and analyzed. Five subjects were tested for the data collection. Data was collected while the participant completed a concentric motion to ensure Achilles Tendon activation. The testing setup utilizes 3 miniature PCB accelerometers, a PCB 4-channel signal conditioner, a DAQ chassis, and a Modally Hand Impact Hammer in tandem with NI signal view express and MATLAB. Once the results from the study were analyzed, a virtual model was setup in the same configuration in OpenSim and the results from the simulation were compared to the results from the testing. The mechanical forces on the Achilles Tendon will be analyzed using the OpenSim software in order to better understand the muscle actuation at various loading levels. The proposed methods offer a non-invasive approach for studying in vivo muscle-tendon mechanics.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126087257","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Neck Motions and Loads With Head Supported Mass Under Sagittal Accelerative Loading 矢状加速载荷下头部支撑质量的颈部运动和负荷
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-72109
Yuvaraj Purushothaman, N. Yoganandan
{"title":"Neck Motions and Loads With Head Supported Mass Under Sagittal Accelerative Loading","authors":"Yuvaraj Purushothaman, N. Yoganandan","doi":"10.1115/imece2021-72109","DOIUrl":"https://doi.org/10.1115/imece2021-72109","url":null,"abstract":"\u0000 Studies have reported the susceptibility of females to cervical spine disorders under impact loading in the military and civilian populations. Inertial loading applied to the head-neck complex at its base is an example. Morphological differences exist between female and male cervical necks. The incidence of neck pain is more in the military than in the civilian populations. While use of the head supported mass is less common in the civilian populations, military personnel use head mounted devices: helmet, night vision goggles, etc. Any added head supported mass from the helmet and its attached devices adds to the in vivo head mass. This additional weight on the human head-neck system alters the load path, affects load-sharing, changes the internal forces and moments and kinematics on the osteoligamentous cervical spine column under accelerative and chronic loads. While many studies have been conducted to delineate the role of gender associated with postero-anterior Gx loading injury via experiments, clinical investigations, modeling and epidemiological research, the effect of the added head mass on segmental motions has received less attention. The objective of the study is to determine the role of the head supported mass on the segmental motions and loads on the female cervical spinal column from Gx loading applied to the base of the spine.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130389109","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Algorithm to Avoid Normal Tissue Sacrifice and Thermal Injury of Neighbouring Organs During Radiofrequency Ablation of HCC Tumours Treated Using a Multi-Tine Electrode With Separately Controlled Tines 不同控制时间的多时间电极射频消融治疗HCC肿瘤时避免正常组织牺牲和邻近器官热损伤的算法
Volume 5: Biomedical and Biotechnology Pub Date : 2021-11-01 DOI: 10.1115/imece2021-69744
M. Dhiman, R. Repaka
{"title":"Algorithm to Avoid Normal Tissue Sacrifice and Thermal Injury of Neighbouring Organs During Radiofrequency Ablation of HCC Tumours Treated Using a Multi-Tine Electrode With Separately Controlled Tines","authors":"M. Dhiman, R. Repaka","doi":"10.1115/imece2021-69744","DOIUrl":"https://doi.org/10.1115/imece2021-69744","url":null,"abstract":"\u0000 Radiofrequency ablation of Hepatocellular Carcinomas lacks electrode level feature to (a) avoid the risk of thermal injury to the neighbouring organs and (b) avoid the sacrifice of normal hepatic tissue. The absence of such a feature causes additional intrusion of the human body to overcome the first problem, while there is no solution for the latter problem. An algorithm has been developed and implemented using an unconventional multi-tine RFA electrode to incur ablations specific to the shape and position of target tumours to solve these problems. Further, this algorithm can suggest the best insertion angle for the trocar, such that minimum normal tissue is sacrificed. This suggestion is made quickly with the help of a pre-simulated database. For verification of the algorithm, pre-segmented tumours have been used as inputs and damages incurred with and without algorithm have been compared.","PeriodicalId":314012,"journal":{"name":"Volume 5: Biomedical and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122141781","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信