Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.最新文献

筛选
英文 中文
Field analysis and balancing tools 现场分析和平衡工具
D. H. Shreve
{"title":"Field analysis and balancing tools","authors":"D. H. Shreve","doi":"10.1109/EEIC.2005.1566327","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566327","url":null,"abstract":"This paper first examines the needs for the basic set of tools for machine condition monitoring applications, including a look at the key elements of detection, analysis, and correction. It then examines the requirements for tools in each area, and proposes a solution on how they can be combined in one palm-sized instrument and portable toolkit for maintenance personnel","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"158 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116082979","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Revitalizing and refurbishment of motor control centers AT NJI & BMC NJI和BMC电机控制中心的改造和翻新
J.C. Pearson, D. Pandya
{"title":"Revitalizing and refurbishment of motor control centers AT NJI & BMC","authors":"J.C. Pearson, D. Pandya","doi":"10.1109/EEIC.2005.1566292","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566292","url":null,"abstract":"This paper provides a case study of considering an economical evaluation comparing a traditional approach of completely demolishing old electrical MCCs equipment versus investigating and replacing only the malfunctioning components in the MCC. The example below illustrates how a thorough investigation of existing electrical equipment can entirely alter previous planning decisions and have a drastic impact on cost estimates. A case study detailing the revitalization of 276, thirty three year old Motor Control Center (MCC) buckets, improved safety and security for our employees and facility equipment, extended overall life of the motor control center (MCCs), enhanced skills of our employees, and saved more than one million dollars for the US Postal facility-at Jersey City, NJ","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"282 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116085165","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Considerations of AC and DC testing of large electrical stator windings and components 大型电气定子绕组和元件交流和直流测试的考虑
F. Emery
{"title":"Considerations of AC and DC testing of large electrical stator windings and components","authors":"F. Emery","doi":"10.1109/EEIC.2005.1566255","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566255","url":null,"abstract":"This paper is written on the basis of recommendations in IEEE Std 95-2002. It is common practice to use both AC and DC power supplies for the high potential testing of large electrical generator stator windings. A much higher voltage, well above the machine operating voltage; is almost always used. This paper reviews the procedures, results and test aspects of both the AC and DC testing of stator coils and the completed stator winding. The major issues addressed are the voltage levels used; where and when they are applied; the relationship between the AC and DC test voltage levels; what components of the winding are actually being tested; and are the presently used multiplication factors between DC and AC really being used correctly? A significant issue to address is that the stator coils and the stator winding layout, is designed to primarily get through the final AC or DC hi-pot test Should this present way of thinking still be followed in going forward in the future?","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133682484","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Experimental study on the ion migration of DC support ceramic insulators 直流支撑陶瓷绝缘子离子迁移的实验研究
Chengrong Li, B. Qi, Z. Shu
{"title":"Experimental study on the ion migration of DC support ceramic insulators","authors":"Chengrong Li, B. Qi, Z. Shu","doi":"10.1109/EEIC.2005.1566294","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566294","url":null,"abstract":"A ion migration testing for DC ceramic support insulators was designed and conducted in this paper. After the long-term ion migration testing, the change of Na+ distribution in the tested samples was analyzed, and the mechanical performance of the tested samples was verified. It is indicated from our results that the ion migration testing in our laboratory doesn't influence the mechanical performance for the ceramic support insulators","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115635091","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Revisions of the periodic conformance testing procedures in the NEMA MW 1000 magnet wire standard 修订了NEMA MW 1000磁性线标准中的定期一致性测试程序
D. Barta
{"title":"Revisions of the periodic conformance testing procedures in the NEMA MW 1000 magnet wire standard","authors":"D. Barta","doi":"10.1109/EEIC.2005.1566246","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566246","url":null,"abstract":"In the last few years, there has been a considerable amount of activity generated in the NEMA 6-MW Technical Committee due to a change in philosophy regarding the periodic conformance testing of magnet wire products. In the past, the periodic conformance tests have been designed around the special testing of a few standard AWG sizes, to define the unique properties of a particular magnet wire product type. These periodic conformance tests have been used to describe the uniqueness of the particular insulation system of the MW type, rather than to describe the expected performance of different wire sizes in these periodic conformance tests. The need to perform these periodic conformance tests on other wire sizes has created the demand for a new approach","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115142125","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Evaluation of medium voltage groundwall insulation exposed to high frequency pulse voltages 高频脉冲电压下中压接地墙绝缘的评价
S. Haq, S. Jayaram, E. Cherney
{"title":"Evaluation of medium voltage groundwall insulation exposed to high frequency pulse voltages","authors":"S. Haq, S. Jayaram, E. Cherney","doi":"10.1109/EEIC.2005.1566289","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566289","url":null,"abstract":"Class-F 4.0 kV coils designed for medium voltage induction motors are aged under combined thermal and electrical stresses of 500 h at a constant temperature of 120degC and 200 h at a constant temperature of 150degC and stressed electrically at 60 Hz and with steep-front unipolar pulses of 40 ns rise time. The changes in the partial discharge activity and the dissipation factor as a function of time are reported. During ageing, the temperature profiles are recorded with an infrared camera as a means for determining the highest stressed regions. The experimental results show that pulse ageing is very severe when compared to 60 Hz ageing, despite using a lower pulse voltage, although the location where damage occurs on the groundwall insulation is different","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123384000","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Exporting solid models into finite element analysis (FEA) for reverse engineering of electrical components 将实体模型导出到有限元分析(FEA)中,用于电气元件的逆向工程
T. Waggoner
{"title":"Exporting solid models into finite element analysis (FEA) for reverse engineering of electrical components","authors":"T. Waggoner","doi":"10.1109/EEIC.2005.1566297","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566297","url":null,"abstract":"Some products are reverse engineered RE as an origin in the design process while others are based on a new inception. In a globally competitive market it is important to reverse engineer electrical products and components for manufacture. Competitor's products are reverse engineered to generate a cost basis to keep a manufacturer's pricing in line with markets. The process of reverse engineering can also be used to regenerate obsolete parts or ones that are out of production and needed for service needs. The reverse engineered part or one designed completely in a solid modeling (SM) package parallels the future manufacture of the part and corresponding assembly. Animation and analysis are integrated into the SM and FEA modeling of the part","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"81 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122080365","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Diagnosis of electrical treeing phenomenon in XLPE insulation 交联聚乙烯绝缘电气树状现象的诊断
Y. Juan, S. Birlasekaran
{"title":"Diagnosis of electrical treeing phenomenon in XLPE insulation","authors":"Y. Juan, S. Birlasekaran","doi":"10.1109/EEIC.2005.1566250","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566250","url":null,"abstract":"Electrical tree formed in XLPE insulation sliced from 220 kV rated cable was diagnosed by partial discharge and dielectrometry measurements and optical observation. The effects of aging by rate of rise in electrical stress and time are reported. Observed intermittent light emission and tree paths supported the theory of emission of protons due to high energy electrons","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129625713","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Material properties of conductive laminates used in turbine generator stator slots 涡轮发电机定子槽用导电层压板材料性能研究
M. Miller, F. Emery
{"title":"Material properties of conductive laminates used in turbine generator stator slots","authors":"M. Miller, F. Emery","doi":"10.1109/EEIC.2005.1566266","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566266","url":null,"abstract":"Siemens power generation uses flat conductive laminate to aid in the wedging of stator coils for specific turbine generator stator winding designs. The laminate material must provide critical electrical, mechanical and thermal properties to properly function. This paper describes testing and interpretation of material test results for conductive laminate materials used as stator slot filler. The stator coil designs are gas-cooled using either hydrogen or air depending on the generator design","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"28 9","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120862381","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A unique system for reducing high frequency stray noise and transient common mode ground currents to zero, while enhancing other ground issues 一个独特的系统,减少高频杂散噪声和瞬态共模接地电流为零,同时加强其他接地问题
R. Jacky, R.W. Hopkins, M. Panko
{"title":"A unique system for reducing high frequency stray noise and transient common mode ground currents to zero, while enhancing other ground issues","authors":"R. Jacky, R.W. Hopkins, M. Panko","doi":"10.1109/EEIC.2005.1566288","DOIUrl":"https://doi.org/10.1109/EEIC.2005.1566288","url":null,"abstract":"Variable frequency drives generate high frequency switching electrical noise. The components of a typical variable frequency drive are commonly capacitively coupled to an earth ground. The power devices used today allow high frequency currents and common mode currents to circulate within earth ground. These circulating currents initiate the degradation process to insulation systems of motors, their bearings, and also interference to other systems (ie: sensors, PLC's, industrial computers etc.). This new wiring design and method meet safety ground code requirements while reducing significantly high frequency and common mode ground currents. In this paper we will discuss the key components and operation of such a system and its application","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"484 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127568207","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信