The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.最新文献

筛选
英文 中文
Nanomechanical detection of phospholiposome using piezoresistive cantilever sensor 压阻悬臂式传感器对磷脂体的纳米力学检测
S. Hyun, H.S. Kim, Y. Kim, H.I. Jung
{"title":"Nanomechanical detection of phospholiposome using piezoresistive cantilever sensor","authors":"S. Hyun, H.S. Kim, Y. Kim, H.I. Jung","doi":"10.1109/SENSOR.2005.1497441","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1497441","url":null,"abstract":"Here, we firstly report the detection of phospholiposomes by the highly sensitive microfabricated piezoresistive cantilever sensor chip and the phosphatidylserine (PS) recognition protein C2A which is chemically immobilized on the sensor surface. The signal created from the bending motion of the piezoresistive cantilever after the phospholiposome attachment has been monitored in real time. And the sensitivity of the sensor was determined judging from the co-relationship between electrical signal and the number of liposome particles.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"4 1","pages":"1792-1795 Vol. 2"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76380432","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Micromachined mid-infrared tunable Fabry-Perot filter 微机械中红外可调谐法布里-珀罗滤波器
N. Neumann, K. Hiller, S. Kurth
{"title":"Micromachined mid-infrared tunable Fabry-Perot filter","authors":"N. Neumann, K. Hiller, S. Kurth","doi":"10.1109/SENSOR.2005.1496626","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1496626","url":null,"abstract":"This contribution deals with the design, fabrication and test of a micromachined first order Fabry-Perot (FP) filter that is intended for use in advanced infrared gas analysis. To achieve optimal interference conditions within an FP filter, the roughness and the curvature of its reflectors must be minimized, while the parallelism between reflectors is maintained. The approach here minimizes mirror curvature by using 300 /spl mu/m thick mirror carriers for the coplanar fixed and movable reflectors of the FP filter. Dielectric reflectance stacks consisting of deposited alternating layers of silicon dioxide (SiO/sub 2/) and polycrystalline silicon (Si) are used as the mirror reflectors and single and a multilayer antireflection coating is used at the silicon/air interface. The cavity spacing is electrostatically driven.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"276 1","pages":"1010-1013 Vol. 1"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82252404","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Wafer-level integration technology of surface mount devices using automatic parts alignment technology with vibration 表面贴装器件的晶圆级集成技术采用带有振动的自动零件对准技术
M. Sudou, H. Takao, K. Sawada, M. Ishida
{"title":"Wafer-level integration technology of surface mount devices using automatic parts alignment technology with vibration","authors":"M. Sudou, H. Takao, K. Sawada, M. Ishida","doi":"10.1109/SENSOR.2005.1497324","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1497324","url":null,"abstract":"This paper presents a new wafer-level integration technology of discrete surface mount devices (SMDs) on silicon-wafers. It is automatic parts alignment on silicon-wafer by means of gravity force and vibration. After silicon IC process, deep holes were formed by deep reactive ion etching (DRIE) process to arrange SMDs. Then a non-conductivity adhesive was spin coated and removed it on the silicon-wafer surface leaving the adhesive at the bottom of the holes. We fixed the silicon-wafer diagonally to a vibration generator and distribute SMDs on it. By vibrating the silicon-wafer, SMDs go down to the lower side occupying the holes automatically. As a result, two different sizes of SMDs were successfully mounted into every hole on silicon wafer. This technology is promising to integrate various discrete devices on integrated devices with batch process-like productivity.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"37 1","pages":"1322-1325 Vol. 2"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81475418","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Step-wise tunable microbolometer long-wavelength infrared filter 步进可调微测热计长波红外滤光片
Y. Wang, B. Potter, M. Sutton, R. Supino, J. Talghader
{"title":"Step-wise tunable microbolometer long-wavelength infrared filter","authors":"Y. Wang, B. Potter, M. Sutton, R. Supino, J. Talghader","doi":"10.1109/SENSOR.2005.1496625","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1496625","url":null,"abstract":"This paper covers the design, fabrication, and testing of a step-wise tunable long-wavelength infrared filter. The design uses a modified type of microbolometer to filter infrared light in the 7-10 micrometer wavelength range. Fabrication of the device is accomplished using standard microelectronic and microelectromechanical systems (MEMS) fabrication techniques. Germanium and zinc sulfide are used as optical layers for good reflectivity in the desired infrared range. Testing of the device shows that it filters light in three absorption bands in the specified wavelength range. The tuning of the device is found to be step-wise in response to electrostatic actuation using voltages up to 100 volts.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"446 1","pages":"1006-1009 Vol. 1"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82899906","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Fabrication of a novel 3D 8/spl times/8 electrode array for artificial retina 一种新型3D 8/spl次/8人工视网膜电极阵列的制备
K. Koo, Hum Chung, Youngsuk Yu, Jong-mo Seo, Jaehong Park, Jung-Min Lim, S. Paik, A. Lee, Sungil Park, H. Choi, Myoung-Jun Jeong, D. Cho
{"title":"Fabrication of a novel 3D 8/spl times/8 electrode array for artificial retina","authors":"K. Koo, Hum Chung, Youngsuk Yu, Jong-mo Seo, Jaehong Park, Jung-Min Lim, S. Paik, A. Lee, Sungil Park, H. Choi, Myoung-Jun Jeong, D. Cho","doi":"10.1109/SENSOR.2005.1497403","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1497403","url":null,"abstract":"This paper presents a novel 3D 8/spl times/8 multi-electrode array for artificial retina application. Each electrode features a triangular pyramidal structure that composed of one (111) plane and two vertical planes. The coneangle between the (111) plane and the vertical plane is 19.5/spl deg/. The sharp triangular pyramidal structure makes the minimal invasive penetration for the inner limiting membrane. The characteristic measurement of impedance magnitude and the phase shift of a single electrode are 1.19 M/spl Omega/ and 80.8/spl deg/ at 1 kHz, respectively.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"32 1","pages":"1640-1643 Vol. 2"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89608508","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Bulk-micromachined lithium niobate sensor and actuator for harsh environments 用于恶劣环境的大块微机械铌酸锂传感器和执行器
A. Randles, S. Tanaka, B. Pokines, M. Esashi
{"title":"Bulk-micromachined lithium niobate sensor and actuator for harsh environments","authors":"A. Randles, S. Tanaka, B. Pokines, M. Esashi","doi":"10.1109/SENSOR.2005.1497338","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1497338","url":null,"abstract":"A lithium niobate actuator has been successfully fabricated using bulk-micromachining with a metal mask. The method reported here uses a chrome/gold mask and then etching on the lithium niobate is carried out in hydrofluoric acid at 80 /spl deg/C. This results in an etch rate of 50 /spl mu/m/h and an undercut of the 5.5 /spl mu/m/h. The fabricated actuator used the deep trenches etched into the lithium niobate, and nickel electrodes were electroplated into these trenches. The actuator was tested but the deflection was as small as 4.9 /spl times/ 10/sup -4/ /spl mu/m/V. This is because lithium niobate was not properly re-poled, so that piezoelectric deformation in the lithium niobate canceled out.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"53 1","pages":"1380-1383 Vol. 2"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89744738","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Comparison of two seal technologies for hydraulic microactuators 液压微执行器两种密封技术的比较
M. D. De Volder, J. Peirs, D. Reynaerts, J. Coosemans, R. Puers, O. Smal, B. Raucent
{"title":"Comparison of two seal technologies for hydraulic microactuators","authors":"M. D. De Volder, J. Peirs, D. Reynaerts, J. Coosemans, R. Puers, O. Smal, B. Raucent","doi":"10.1109/SENSOR.2005.1496424","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1496424","url":null,"abstract":"In order to improve the power density of microactuators, recent research focuses on the applicability of fluidic power at microscale. One of the reasons that hydraulic actuators are still uncommon in micro system technology is due to the difficulty of fabricating powerful microseals. This paper presents two seal technologies that are suitable for sealing small-scale hydraulic actuators. Measurements on prototype actuators show that force densities up to 0.45 N/mm/sup 2/ (0.025 N/mm/sup 3/) and work densities up to 0.2 mJ/mm/sup 3/ can easily be achieved with the developed seal technology. These characteristics can still be improved as the maximum driving pressures of the actuators have not yet been determined.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"41 1","pages":"333-336 Vol. 1"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89419688","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Electrical critical dimension measurement method by integration of test structure into MEMS devices 将测试结构集成到MEMS器件中的电气临界尺寸测量方法
K. Ito, Y. Mita, M. Kubota, F. Marty, T. Bourouina, T. Shibata
{"title":"Electrical critical dimension measurement method by integration of test structure into MEMS devices","authors":"K. Ito, Y. Mita, M. Kubota, F. Marty, T. Bourouina, T. Shibata","doi":"10.1109/SENSOR.2005.1497501","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1497501","url":null,"abstract":"An in-device electrical measurement method of critical dimensions (CD) width in MEMS devices is proposed. It alternates conventional critical dimension measurements by image taking apparatus, such as CD-SEMs. Integration of electrical critical dimension measurement test structures into MEMS devices enables us to measure critical dimension width of the working device. A method to remove the disturbance of the repeatability by joule heating, which is inevitable in electrical measurements, is proposed. By grace of the joule-heating disturbance elimination method, an extremely high repeatability (50nm for 5/spl mu/m silicon structure, 1nm for 1.5/spl mu/m aluminum structure) was obtained by a simple measurement using only multimeters.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"284 1","pages":"2031-2034 Vol. 2"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86742179","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Reliability of non-released microstructures: failure analysis and innovative solution process 非释放微结构的可靠性:失效分析和创新解决过程
O. Millet, P. Muller, O. Blanrue, B. Legrand, D. Collard, L. Buchaillot
{"title":"Reliability of non-released microstructures: failure analysis and innovative solution process","authors":"O. Millet, P. Muller, O. Blanrue, B. Legrand, D. Collard, L. Buchaillot","doi":"10.1109/SENSOR.2005.1496548","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1496548","url":null,"abstract":"The paper deals with the investigation of microstructure failures due to storage between two steps of the fabrication process, and with the presentation of an innovative process avoiding these failures. Applications in fabrication process, corrective processes on released structures and reverse engineering are thanks to nanoindentation on mobile parts.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"8 1","pages":"840-842 Vol. 1"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87609541","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A micromachined biopsy tool for a capsule type endoscope 一种用于胶囊型内窥镜的微机械活检工具
S. Moon, Y. Choi, S.S. Lee
{"title":"A micromachined biopsy tool for a capsule type endoscope","authors":"S. Moon, Y. Choi, S.S. Lee","doi":"10.1109/SENSOR.2005.1497336","DOIUrl":"https://doi.org/10.1109/SENSOR.2005.1497336","url":null,"abstract":"In this paper, a nickel electroplating process has been developed for the micromachined biopsy tool useful for the capsule type endoscope. Long shaft and sharp tip biopsy tool is easily fabricated using thick PR (SU8) mold by one mask lithography process. These micro scale biopsy tools are readily integrated with conventional forceps system or capsule type endoscope. The characteristics of various biopsy tool design features including tip taper angle, tool geometries, and cutting knife number were studied for the tissue extraction from an mice intestine. The fabricated biopsy tools had proper strength and sharpness for tissue extraction and the tools extracted sufficient amount of tissues for a clinical test.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"48 1","pages":"1371-1374 Vol. 2"},"PeriodicalIF":0.0,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87897983","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信