{"title":"Energy efficiency analysis of energy facilities using ranking methods","authors":"V. Less, V. Lyubchenko, D. Pavlyuchenko","doi":"10.30724/1998-9903-2023-25-5-42-58","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-5-42-58","url":null,"abstract":"RELEVANCE. Increasing energy efficiency is one of the necessary conditions for modernizing the Russian economy. High energy intensity and energy efficiency analysis are due to the combined influence of a number of factors, both global and private. Thus, for electric grid organizations the problem of energy efficiency is a priority. Having at their disposal electrical grid facilities, including points of reception and transmission of electrical energy, electrical equipment and power transmission lines, electrical grid organizations incur huge losses caused by losses during the transmission of electrical energy, losses associated with the unaccounted share of electricity, as well as third-party factors. OBJECT. Conduct an analysis of the energy efficiency of an electric grid organization that has 10 branches. Form a hierarchy of energy efficiency indicators, determine the impact of each indicator on the integral indicator that reflects the energy efficiency of the facility. Conduct benchmarking, identify leaders and outsiders among power grid organizations. METHODS. To calculate the weight coefficients, the method of analysis of hierarchies in the classical and fuzzy formulations was used. Energy efficiency benchmarking was carried out by ranking power grid organizations according to the integral indicator of energy efficiency. RESULTS. A three-level hierarchy of energy efficiency indicators has been formed. A decision-making algorithm is presented when analyzing the energy efficiency of energy industry facilities. The weight coefficients of indicators and integral values of energy efficiency of organizations are calculated. The indicators that have the greatest impact on the overall efficiency of the facility were identified. A summary diagram of comparison of all branches has been formed, the most and least successful organizations have been identified. CONCLUSIONS. The analysis of energy efficiency, carried out using two methods of analysis of hierarchies, made it possible to identify the advantages and disadvantages of the classical representation of the method. Determination of leaders within the branch structure of the electric grid organization allows us to analyze the methods used to improve energy efficiency, as well as to introduce them in the future to less successful branches.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":"33 13","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139532110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Soluyanov, Yu. I. Soluyanov, A. I. Fedotov, A. Akhmetshin
{"title":"Development of changes to the construction code of rules in part of updated specific electrical loads","authors":"V. Soluyanov, Yu. I. Soluyanov, A. I. Fedotov, A. Akhmetshin","doi":"10.30724/1998-9903-2023-25-6-89-100","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-6-89-100","url":null,"abstract":"THE PURPOSE. Develop changes to the building code of rules regarding updating the specific calculated electrical loads of multi-apartment residential buildings. Perform a comparative analysis of the power of technological connection of multi-apartment residential buildings, calculated according to regulatory and technical documents and according to those developed on the basis of actual measured data with an assessment of the effect of updating specific design electrical loads.METHODS. To achieve this goal, mathematical and statistical methods of analysis were used.RESULTS. Statistical processing of the specific electrical load of apartments in multi-apartment residential buildings in the Moscow region of a cluster of 11–18 floors for twenty-three months of 2021–2023 was carried out, which made it possible to form statistically significant samples by excluding outliers from them and obtaining their basic descriptive statistics. Based on the results obtained, changes were developed to the regulatory and technical document in terms of updating the specific calculated electrical loads of apartments in multi-apartment residential buildings in the Moscow region of the cluster 11 - 18 floors.CONCLUSION. The introduction of updated values of the specific calculated electrical load will lead to the selection of power transformers with optimal loading, which, on the one hand, will reduce the “locked electrical power”, resulting in reduced electricity losses, and on the other hand, will reduce the cost of technological connection.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":"9 10","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139532406","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study of the features of hydrochemical characteristics and development of zooplankton in the area of water-air curtain type fish protection structure in the cooling reservoir of the SDPP","authors":"M. Kalaida, A. R. Saetov, M. Khamitova","doi":"10.30724/1998-9903-2023-25-6-101-118","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-6-101-118","url":null,"abstract":"PURPOSE. Study of the features of hydrobiological characteristics of zooplankton development under operating conditions of a fish protection structure similar to a water-air curtain (WAC) at an energy facility.METHODS. Hydrobiological material was collected, processed and analyzed on the physical and chemical characteristics of water and on the qualitative and quantitative composition of zooplankton in the water intake area of the Zainskaya State District Power Plant. A comparative analysis of our own research and literature data on the characteristics of water in the area of a water-air curtain fish protection structure was carried out. The material was processed using generally accepted hydrobiological methods in the laboratory of the Department of Aquatic Bioresources and Aquaculture of Kazan State Energy University.RESULTS. It is shown that a fish protection device of the water-air curtain type is a multifunctional technical solution, which during operation changes the physical and chemical characteristics of the state of the ecosystem, especially in the bottom layer. It was revealed that a fish protection structure (FPS) like a water-air curtain does not reduce the species diversity of zooplankton. In the area where the WAC operates, the maximum abundance and biomass of zooplankton were noted compared to control stations. The basis of the number and biomass of zooplankton were crustaceans: cladocerans accounted for 50.2% of the total biomass, copepods accounted for 46.1%.CONCLUSION. Observations of the state of the ecosystem in the area of operation of the water-air curtain and assessment of water quality based on hydrobiological indicators revealed high water quality in the area where the WAC operates, and an improvement in the environmental situation.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":" 10","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139624291","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Risk-based approach to choosing the production asset management strategy for energy company","authors":"V. Levin, N. Guzhov, D. A. Boyarova","doi":"10.30724/1998-9903-2023-25-6-29-42","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-6-29-42","url":null,"abstract":"RELEVANCE: The possibility of a reasonable choice of an alternative strategy for the organization of maintenance and repair (M&R) of the power company's equipment is a guarantee of the successful implementation of its strategic priorities. The tasks in this direction are quite relevant.PURPOSE: To develop a unified methodology that, from the general standpoint of a risk-based approach, would allow comparing two alternative strategies for managing the assets of an energy company \"by periodicity, operating time\" and \"by technical condition\", according to a set of key criteria for the effectiveness of M&R.METHODS: When solving problems, methods of forming and adjusting schedules for repairs of electrical equipment, calculating reliability and probabilities of failure in the power supply system of consumers, taking into account its circuit features, assessing the technical condition of equipment according to non-destructive testing and diagnostics, comparing the costs of maintaining and restoring reliability and damages from its violations were used.RESULTS: A risk-oriented methodology has been developed and verified, which makes it possible to evaluate and select the optimal equipment maintenance strategy for the energy company according to uniform efficiency criteria. An algorithmic implementation of the developed methodology is obtained, which is the basis of a computing complex for choosing and making decisions. The verification of the methodology and algorithm is carried out on the example of a real object – a power supply system for oil production consumers using reliable operational and diagnostic information.CONCLUSION: The results obtained fully compensate for the lack of methodological possibilities in comparing two basic alternative strategies for electrical equipment maintenance based on a single risk-based approach. The developed methodology is a unified decision-making tool at the stage of alternative analysis. The illustration of the methodology by a real numerical example demonstrates the consistency of the solutions obtained with the results of expert assessments and operational experience.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":"24 11","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139534382","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Garifullin, Y. N. Slobodina, A. R. Bikzinurov, R. A. Giniatullin, V. A. Chernyshov
{"title":"Investigation of the content of unsaturated hydrocarbons in transformer oils using IR spectroscopy","authors":"M. Garifullin, Y. N. Slobodina, A. R. Bikzinurov, R. A. Giniatullin, V. A. Chernyshov","doi":"10.30724/1998-9903-2023-25-5-3-19","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-5-3-19","url":null,"abstract":"THE PURPOSE. To analyze the current understanding of unsaturated hydrocarbons with double C=C bonds in mineral transformer oils and evaluate the effectiveness of modern methods of controlling the content of these compounds in oils. Develop an instrumental way to control unsaturated compounds in mineral oils by means of IR spectroscopy. Study the change in the content of unsaturated hydrocarbons in oils during thermal degradation. Study the effectiveness of the adsorption purification of oils to remove unsaturated compounds from oils. METHODS. To determine the content in mineral oils of unsaturated hydrocarbons used IR spectroscopy in the near infrared spectral region. Artificial thermal degradation of oils was carried out at temperatures of 100 and 150 ºC. For adsorption purification of oils silica gels brands KSKG, AS230SH, as well as Fuller's Earth adsorbent were used. RESULTS. Spectral range 4750÷4500 cm-1 and method of IR spectra transformation were chosen to control the content of unsaturated compounds with double C=C bonds in the oil. As a result of model experiments, it is clearly demonstrated that the content of unsaturated hydrocarbons increases with increasing degree of thermal degradation of oils. It is shown that adsorption purification has a low efficiency with respect to unsaturated compounds. An algorithm for differentiation of fresh mineral transformer oils produced by hydrocracking technology from the regenerated oils is proposed. CONCLUSION. The highest content of unsaturated compounds is contained in mineral oils produced by technologies other than hydrocracking. Thermo-oxidative impact on oil during its operation leads to an increase in the content of unsaturated hydrocarbons in the oil. The content of unsaturated hydrocarbons in the mineral transformer oil characterizes the degree of degradation of its hydrocarbon base that cannot be recovered during regeneration.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":"47 19","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139534079","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modernization of local heat distribution stations of city heat supply system","authors":"Yu. A. Gorinov, P. N. Anisimov, E. V. Egoshin","doi":"10.30724/1998-9903-2023-25-6-43-53","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-6-43-53","url":null,"abstract":"The PURPOSE of this work is to develop technical solutions to increase the efficiency of functioning of centralized urban heating systems by modernizing local heat distribution stations. The article considers the issues of functioning of district heating systems with open water intake. The work presents technical solutions that increase the efficiency of the local heat distribution station with a hot water supply unit. A technological scheme has been developed, the selection of equipment has been made. The feasibility of using the developed technical solutions is confirmed by technical, economic and investment indicators. The objectivity of determining the technical and economic effect of the modernization of the local heat distribution station is ensured by comparing the obtained indicators of the modernized and similar facilities.METHODS. To fulfill the objectives of the study, the following methods were applied: full-scale tests on a real object; processing of experimental data using application programs; feasibility study in the municipal heat power industry.THE RESULTS show an improvement in the technical and economic performance of the heating and hot water supply system of an apartment building in Yoshkar-Ola city: reduced network water consumption by 36–39%; temperature drop in the return pipeline was 13.5%; the heat content of hot water has been reduced to 0.168 Gcal/m3 (normative heat content is 0.145 Gcal/m3), the required circulation was ensured in all risers of the hot water supply system. The total losses from October 2021 to September 2022 are 3486,4 Gcal or 11.4% of heat supplied to consumers, which is less than 13% set by the tariff. Compared to a similar house without a regulation depending on the outside air temperature, the consumption of thermal energy during the heating season is reduced by 80 Gcal (10.9%).CONCLUSION. The new scheme of a local heat distribution station has been proposed, including the regulation of domestic hot water (DHW) recirculation, as well as the installation of a hydroelevator with weather regulation. The developed technical solution is relevant for district heating systems with open water intake. For the first time, an experimental study of the effect of the joint installation of the following equipment was carried out: a pump and a control valve on the DHW recirculation line before the recirculation mixing unit with the return pipeline of the heating system; hydraulic elevator with weather regulation. The results of the study can be used in the feasibility study of similar circuit solutions for the modernization of DHW systems. Operating experience has shown that the application of the developed technological scheme of local heat distribution station has positive effects: reduction of network water consumption, temperature in the return pipeline and heat losses; improvement of circulation in all risers of the DHW system; reduction of thermal energy consumption during the period of the “lower” cutoff","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":" 39","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139627199","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yura Bulatov, A. N. Kryukov, K. V. Suslov, V. V. Kizhin
{"title":"Coordinated management of electricity storages and distributed generation plant with predictive controllers in a power supply system with reduced electricity quality","authors":"Yura Bulatov, A. N. Kryukov, K. V. Suslov, V. V. Kizhin","doi":"10.30724/1998-9903-2023-25-6-3-13","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-6-3-13","url":null,"abstract":"THE PURPOSE. A study of the influence of coordinated control of electricity storage devices and distributed generation installations on the operating modes of a network cluster, which is an electrical distribution network connected to the AC railway power supply system through a direct current insert (DCI).METHODS. The studies were carried out using a simulation model implemented in the MATLAB system.RESULTS. The following disturbing influences were considered: turning off the main power supply of the network cluster from the DCI side for 0.5 seconds; three-phase short circuit with a duration of 0.5 s at the end of a 6 kV cable line with a length of two kilometers. The simulation results showed the effectiveness of coordinated control of electricity storage devices and a turbogenerator with self-adjusting predictive controllers. On this basis, the values of overshoot of the rotor speed are reduced and the transient process time is reduced for all parameters in various modes. For example, the transient time for the generator rotor speed in the mode of connecting an additional load is reduced by three times, and for voltage - by two times.CONCLUSION. Based on computer modeling, it is shown that coordinated control of electricity storage devices and a turbogenerator with predictive regulators reduces the amount of rotor speed overshoot to almost zero and reduces the transient process time by almost 90%. It is advisable to conduct further research on the application of the method of coordinated control of active elements used in the power supply system to regulate the mode parameters.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":" 6","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139625521","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
N. D. Yakimov, A. F. Shageev, A. V. Dmitriev, G. R. Badretdinova
{"title":"Features of calculating the temperature field in an annular porous layer under infinite heating","authors":"N. D. Yakimov, A. F. Shageev, A. V. Dmitriev, G. R. Badretdinova","doi":"10.30724/1998-9903-2023-25-6-54-66","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-6-54-66","url":null,"abstract":"To date, easily recoverable oil reserves have already been extracted, so deposits with residual oil reserves or places with weak permeability are of great interest. It is known that oil becomes more viscous when the temperature decreases, which creates difficulties in its production. Therefore, to reduce the viscosity, it is necessary to heat the oil to the temperature at which it is possible to realize its production. The study proposes a mathematical model for calculating the temperature field in an annular porous layer under infinite heating in a downhole reactor for continuous heating of the bottom-hole zone of a formation containing high-viscosity oil and natural bitumen (HVO and NB).PURPOSE. To construct a heating solution for an infinitely long annular layer in a downhole reactor. To obtain a temperature profile in the cross section of the annular layer and a picture of the temperature field.METHODS. The equations of the mathematical model are based on the laws of conservation of energy and mass, their study and evaluation are carried out using analytical methods of the theory of differential equations, methods of similarity theory and dimensions, as well as numerical methods for solving boundary value problems. results. In the course of the study, the dependences of the distance at which the set air temperature in the reactor is reached at different values of mass air flow, linear heat flux density and the heat capacity of the mixture were obtained. conclusion. The conducted studies have allowed us to obtain a mathematical model for calculating the temperature field in an annular porous layer under infinite heating in an downhole reactor. The results obtained showed that with an increase in the mass flow rate and the heat capacity of the medium, the distance at which the set air temperature in the reactor is reached increases by 1.6 and 1.5 times, respectively, over the entire temperature range, and with an increase in the linear density of the heat flux, this distance decreases by 0.6 times.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":"34 25","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139533880","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Assessment of the reliability of the mathematical model of the 0.4 kV rural electric network in Matlab Simulink on the example of a study of the steady-state mode of a single-phase short circuit","authors":"A. Lansberg, A. Vinogradov, A. A. Panfilov","doi":"10.30724/1998-9903-2023-25-6-14-28","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-6-14-28","url":null,"abstract":"PURPOSE. Currently, modeling is one of the most reliable ways to study normal and emergency modes of operation of electrical networks. In this regard, a mathematical model of the 0.4 kV rural electric network was developed in the MATLAB Simulink program.PURPOSE. Evaluation of the accuracy of the parameters of the operating modes of the 0.4 kV rural electric network obtained by modeling in MATLAB Simulink by estimating the values of the steady-state single-phase short circuit current at different distances from the transformer substation.METHODS. The currents obtained using the 0.4 kV electrical network model developed in MATLAB Simulink were compared with the currents obtained using other calculation methods (according to GOST 28249-93, the simplified phase-zero loop method and the mathematical model «Project RZA»).RESULTS. It was revealed that the discrepancy in the results at individual points was 9-11%. When simulating a steady-state single-phase short circuit in MATLAB Simulink, it was found that the voltage of the damaged phase A decreases to 0 V, while the voltages on the two remaining intact phases increase by 1.4-1.5 times, i.e.E. by a factor of 2 to the values of 335-354 V when short-circuiting at the transformer terminals and to the values of 329-338 V when short-circuiting behind a section of a 0.4 kV power line.CONCLUSIONS. The resulting mathematical model of a 0.4 kV rural electric network in the MATLAB Simulink program can be used to study normal and emergency operating modes, study the modes of joint operation of renewable energy sources with a centralized network, and the processes of switching on backup generation sources.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":"16 6","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139534273","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R. Khusnutdinov, G. V. Mozzhukhin, N. R. Khusnutdinova, B. M. Salakhutdinov
{"title":"High-Q litz wire NQR sensor for medical applications","authors":"R. Khusnutdinov, G. V. Mozzhukhin, N. R. Khusnutdinova, B. M. Salakhutdinov","doi":"10.30724/1998-9903-2023-25-3-3-11","DOIUrl":"https://doi.org/10.30724/1998-9903-2023-25-3-3-11","url":null,"abstract":"RELEVANCE. The design and development of radio frequency (RF) coil sensors is an important engineering and, at the same time, fundamental task for those radio spectroscopic instruments that require an increase in sensitivity, measured as a signal-to-noise ratio (SNR). Radio spectroscopy of nuclear quadrupole resonance (NQR), especially in nitrogen compounds, in which the resonant frequency is very low and ranges from a few megahertz or lower to hundreds of kilohertz, requires the use of special solutions to increase the sensitivity. PURPOSE. Theoretical substantiation and search for a technical solution that allows achieving high sensitivity on standard equipment through the use of a high-quality sensor. METHODS. Methods for optimizing the design of sensors for NQR/NMR spectrometers are considered. The design of the sensor for the NQR spectrometer, which contains an inductance coil wound with a Litz wire, has been calculated and designed. RESULTS. A high-quality coil for the spectrometer sensor was made, which gives an increase in the quality factor by about 1.5 times. The use of a spectrometer with this coil made it possible to confidently record weak noisy signals of paracetamol at a low duty cycle. The sensitivity of the sensor made it possible to distinguish preparations from different manufacturers by their spectral characteristics. CONCLUSIONS. A solenoid sensor has been developed, modeled and manufactured, which has a high quality factor and allows recording quadrupole resonance signals of drugs (paracetamol) by a non-destructive method directly through the package. The possibility of using such a sensor for quality control of medicines, detection of falsified and counterfeit medicines is shown.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123669137","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}